Abstract

This study deals with the prediction of crack propagation in concrete mortar subjected to static and dynamic load. Total 54 CLWL-DCB(Crack-line-loaded-double-cantilever beam) concrete mortar specimens were tested to measure crack growth using ASTM 561-80. Main variables were sand to cement ratio and water to cement ratio. The resulting load(P)-COD(Crack Opening Displacement; $2V_1$) curves and COD-CTOD (Crack Tip Opening Displacement; $2V_2$) curves were analyzed to calculate effective crack length and physical crack length by way of ASTM 561-80 proposed. Replica crack length were also obtained directly during the test. The differences in crack propagation between under static load and under dynamic load were investigated.

본(本) 연구(硏究)는 재료(材料)의 배합(配合)이 단순한 mortar를 제작 그 균열발생을 관찰, 측정하여 정적하중(靜的荷重)에 의한 균열 및 일정진폭을 갖는 동적하중(動的荷重)에 의한 균열성장영역 예측을 시도한 것이다. 사용시편은 mortar의 배합비(配合比)와 물-시멘트비(比)를 달리하여 ASTM E 561-80에서 제안한 CLWL-DCB(crack-line-loaded-double-cantilever-beam)의 제1방법인 벽개형(劈開型)모드(opening mode)에 의거 균열성장거동을 측정하였다. 본(本) 실험(實驗)에서는 X-Y recorder에 나타난 하중(荷重)(P)-균열개구변위($2V_1$), 균열개구변위($2V_1$)-균열선단개구변위($2V_2$)의 diagram을 해석하여 정적하중(靜的荷重)에 의한 균열선단의 비선형적인 미소균열을 포함하는 유효균열길이(effective crack length; $a_e$)와 균열선단의 미소균열을 제외한 물리적균열길이(physical crack length; $a_m$) 및 replica 필름으로 구한 균열길이(replica crack length; $a_t$)의 상관관계와 일정진폭을 갖는 반복하중에 의한 $a_e$, $a_m$, $a_t$를 구하여 정적하중(靜的荷重)에 의한 균열특성과 동적하중(動的荷重)에 의한 균열특성을 조사한 것이다.

Keywords