• Title/Summary/Keyword: Recorder

Search Result 517, Processing Time 0.03 seconds

Optical Property of Super-RENS Optical Recording Ge2Sb2Te5 Thin Films at High Temperature (초해상 광기록 Ge2Sb2Te5 박막의 고온광물성 연구)

  • Li, Xue-Zhe;Choi, Joong-Kyu;Lee, Jae-Heun;Byun, Young-Sup;Ryu, Jang-Wi;Kim, Sang-Youl;Kim, Soo-Kyung
    • Korean Journal of Optics and Photonics
    • /
    • v.18 no.5
    • /
    • pp.351-361
    • /
    • 2007
  • The samples composed of a GST thin film and the protective layers of $ZnS-SiO_2$ or $Al_2O_3$ coated on c-Si substrate were prepared by using the magnetron sputtering method. Samples of three different structures were prepared, that is, i) the GST single film on c-Si substrate, ii) the GST film sandwiched by the protective $ZnS-SiO_2$ layers on c-Si substrate, and iii) the GST film sandwiched by $Al_2O_3$ protective layers on c-Si substrate. The ellipsometric constants in the temperature range from room temperature to $700^{\circ}C$ were obtained by using the in-situ ellipsometer equipped with a conventional heating chamber. The measured ellipsometric constants show strong variations versus temperature. The variation of ellipsometric constants at the temperature region higher than $300^{\circ}C$ shows different behaviors as the ambient medium is changed from in air to in vacuum or the protective layers are changed from $ZnS-SiO_2$ to $Al_2O_3$. Since the long heating time of 1-2 hours is believed to be the origin of the high temperature variation of ellipsometric constants upon the heating environment and the protective layers, a PRAM (Phase-Change Random Access Memory) recorder is introduced to reduce the heating time drastically. By using the PRAM recorder, the GST samples are heated up to $700^{\circ}C$ decomposed preventing its partial evaporation or chemical reactions with adjacent protective layers. The surface image obtained by SEM and the surface micro-roughness verified by AFM also confirmed that samples prepared by the PRAM recorder have smoother surface than the samples prepared by using the conventional heater.

Study on Strain Measurement of Agricultural Machine Elements Using Microcomputer (Microcomputer를 이용(利用)한 농업기계요소(農業機械要素)의 Strain 측정(測定)에 관(關)한 연구(硏究))

  • Kim, Kee Dae;Kim, Tae Kyun;Kim, Soung Rai
    • Korean Journal of Agricultural Science
    • /
    • v.8 no.1
    • /
    • pp.90-96
    • /
    • 1981
  • To design more efficient agricultural machinery, the accurately measuring system among many other factors is essential. A light-beam oscillographic recorder is generally used in measuring dynamic strain but it is not compatible with the extremely high speed measuring system such as 1,000 m/s, also is susceptable to damage due to vibration while using the system in field. The recorder used light sensitive paper for strip chart recording. The reading and analysis of data from the strip charts is very cumbersome, errorneous and time consuming. A microcomputer was interfaced with A/D converter, microcomputer program was developed for measuring, system calibration was done and the strain generated from a cantilever beam vibrator was measured. The results are summarized as follows. 1. Microcomputer program was developed to perform strain measuring of agricultural machine elements and could be controled freely the measuring intervals, no. of channels and no. of data. The maximum measuring speed was $62{\mu}s$. 2. Calibration the system was performed with triangle wave generated from a function generator and checked by an oscilloscope. The sampled data were processed using HP 3000 minicomputer of Chungnam National University computer center the graphical results were triangle same as input wave and so the system have been out of phase distorsion and amplitude distorsion. 3. The strain generated from a cantilever beam vibrator which has free vibration period of 0.019 second were measured by the system controlled to have l.0 ms of time interval and its computer output showing vibration curve which is well filted to theoretical value. 4. Using microcomputer on measuring the strain of agricultural machine elements could not only save analyzing time and recording papers but also get excellent adaptation to field experiment, especially in measurement requiring high speed and good precision.

  • PDF

A Study on the Effects of the Breath Efficiency & Lung Capacity Improvement Using Recorder Playing Focused on Breath Training (리코더 연주를 통한 뇌졸중 노력성 폐활량과 호흡 효율성 향상 연구)

  • Choi, Sung Joo
    • Journal of Music and Human Behavior
    • /
    • v.4 no.1
    • /
    • pp.31-46
    • /
    • 2007
  • The purpose of the study was to improve the efficiency of Breath & Forced Vital Capacity(FVC) of Stroke Patients Using Record Playing Focused on Breath Training. The Training of Forced Vital Capacity(FVC) is focused on trunk muscles reinforce for Breathing. So the study tried to play Recorder for reinforcing FVC. The play included the two parts. One was for solo play, the other was play in concert base on solo play using Korea country song, Arirang. The Recorder play used abdominal breath, Pursed-lip & Paced methods. The course of play included Long Tone, Staccato, Crescendo, Decrescendo and throughout the course we tried to improve the efficiency & Quantity of breathe. Experiment performed at Social welfare institute for the old. They played & checked FVC, $FEV_1$, $FEV_1/FVC$ before & after breathe 19 times for 6 weeks using Spirovit SP-1, Schiller. After experiment we performed statical process(p<0.05) using statical Package software. The findings were as follows: Analysis for Experiment showed the numerical Value of increasing Of FVC, $FEV_1$, $FEV_1/FVC$. Increasing Percentage of Measured/Predicted FVC, $FEV_1$ (or calculated based on theory) ration was 25%, 13% and Quantity of FVC, $FEV_1$ 35%, 40%. Also $FEV_1/FVC$ Ratio(showed efficiency of breathe) raised 13%. And experiment data was confirmed by statical process. The experiment data was valuable under p<0.05. In Conclusion we think the results of experiment showed the efficiency of Music therapy for Breathe(FVC, $FEV_1$, $FEV_1/FVC$) reinforce.

  • PDF

Regional Distribution of Duration of Sunshine and Percentage of Sunshine by Jordan Type Sunshine Recorder and Bimetal Type Sunshine Recorder (Jordan 일조계(日照計)와 Bimetal 일조계(日照計)로 관측(觀測)된 일조시간(日照時間) 및 일조율(日照率)의 지역분포(地域分布) 비교(比較) 분석(分析))

  • Lee, Jeong-Taek;Yun, Seong-Ho;Park, Moo-Eon;Kim, Byung-Chan
    • Korean Journal of Environmental Agriculture
    • /
    • v.13 no.1
    • /
    • pp.39-46
    • /
    • 1994
  • Two types of sunshine recorders, Jordan and bimetal, were used for measuring the duration of sunshine and percentage of sunshine in Weather Forecast Offices(WFO) and Weather Observation Stations(WOS) in Korea, respectively.These two gauges showed different values in each element observation. To evaluate the solar energy resources by duration and percentage of sunshine, relevant parameter should be adapted to use the two kinds of data for zoning of agricultural climatic area and comparison of regional solar energy distributions. In this respect, the correlation and distribution pattern were found by analyzing data from the two types of sunshine recorders. The results were as follows. The monthly duration of sunshine by the Jordan type was $50{\sim}60$ hours lower than the bimetal type and its value in May was the highest in a year. The percentage of sunshine by the Jordan type was $5{\sim}10%$ lower than the bimetal type. The seasonal difference of sunshine hour data by two types of sunshine recorder became small in winter but large in summer. Standard deviation of monthly duration of sunshine of WFO and WOS was $11{\sim}32$ and $17{\sim}25$ hours and percentage of sunshine was $3{\sim}11$ and $4{\sim}9$ % respectively. The range of deviation in WOS data was smaller than WFO. The highest distribution of duration and percentage of sunshine was in the Southern Coastal Area, whereas the lowest in the Central North Western Area.

  • PDF

A Study on the Level of Medical Record Documentation and Agreement in the Information on the Patient's Past History (과거력 의무기록 정보의 기재정도 및 일치도 분석)

  • Seo, Jung-Sook;Yu, Seung-Hum;Oh, Hyohn-Joo;Kim, Yong-Oock
    • Korea Journal of Hospital Management
    • /
    • v.13 no.1
    • /
    • pp.42-64
    • /
    • 2008
  • This study was conducted to evaluate the quality in medical records by analyzing its completeness through setting up the level of record on the patient's past history and through examining the actual medial records. Targeting the information on the patient's past history in interns' records, residents' records and nurses' records toward 403 inpatients who were admitted first in 2004 at an university hospital due to stomach cancer. We analyzed whether the charts were recorded or not, recording level, the satisfaction with the expectant level of the records in the hospital targeted for a research and the level of agreement. The results were as follows; first, as for the rate of recording those each items, they were high in the chief complaint & present illness and the past illness history. Depending on the group of recorders, the recording rate showed big difference by items. Second, as a result of measuring the level after dividing the recording level of items for the patient's past history from Level 1 to Level 4 by each item, the admission history, the past illness history, and the family history were about Level 3, and the smoking history, the medication history, the chief complaint & present illness, the drinking history and allergy were about Level 2. In the admission department, it was excellent in the interns' records for the medical department. Third, as a result of its satisfactory level by comparing the expect level of a record and the actual record by item in information on the patient's past history, which was expected by the medical-record committee members of the hospital targeted for a study. And forth, we analyzed the level of agreement with Kappa score in the level of 'Yes' or 'None' related to the corresponding matter in Level 1, in terms of information on the past history in the intern's record, the resident's record, and the nurse's record. The level of agreement in the resident's record & the nurse's record, and in the intern's record & the resident's record was from "excellent" to "a little good". There were differences in the level of completeness and in reliability for the information on the past history by the recorder group or by the admission department. The encounter process that was performed by the admission department or the recorder group, indicated the result that was directly reflected on the quality of medical records, thus it was required further study about the medical record documentation process and quality of care. The items that showed the high recording rate quantitatively were rather low, consequently we'd should develop the tool for the qualitative inspection and evaluate the medical records further. And the items were needed to be detailed in the record level were rather low, and hence there needed to be a documentation guideline and education by the clinical departments.

  • PDF

Underwater Telemetering by Ultrasonic Multi-Beam Transducer (Multi-Beam 초음파진동자의 수중원격제어에 관한 연구)

  • Choe, Han-Gyu;Sin, Hyeong-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.27 no.1
    • /
    • pp.31-40
    • /
    • 1991
  • This paper described on the availability fo the underwater telemetering by the ulterasonic multi-beam system made as a trial to expand detectable range of the fish school. The ultrasonic multi-beam system consisted of four transducers which reconstructed with the existing net recorder. The experiment for the telemetering carried out in the set net fishing ground. The results obtained are summerized as follows: 1. The detectable distance of a target by the linear arrangement of four transducers increased according to the sea depth and the interval between transducers. 2. When the fish school in the entrance of set net was measured by linear arrangement of transducers it was entered in depth of 2.5~3.5m at near position of leader, and in depth of 3.5~4.5m at near position of door net. 3. The deviations of error between the actual position and the position by transducer in case of the target depth 1m, 1.5m, 2m were 5.9~27.1cm, 3.2~28.9cm, 3.5~25.8cm respectively, and 68.3% probability radius of them were 14.6cm, 17.7cm, 17.0cm respectively. 4. When the fish school in the fish court of set net was measured by plane arrangement of transducer it was entered toward the opposite direction of tide current. 5. The available distance of telemetering by the multi-beam transducer was 1.8km and the telemetering was possible to control everywhere in case of sea depth more than three meters.

  • PDF

A Study on Real-time Implementing of Time-Scale Modification (음성 신호 시간축 변환의 실시간 구현에 관한 연구)

  • Han, Dong-Chul;Lee, Ki-Seung;Cha, Il-Hawan;Youn, Dae-Hee
    • The Journal of the Acoustical Society of Korea
    • /
    • v.14 no.2
    • /
    • pp.50-61
    • /
    • 1995
  • A time scale modification method yielding rate-modified speech while conserving the characteristic of speech was implemented in real-time using a goneral purpose digital signal processor. Time scale modification changed pronunciation speed only, producing a time difference between the input signal and the modified signal, making it impossible to implement it in real-time. In this thesis, a system was implemented to remove the time difference between the input and modified signals. Speech signals slowed down or speeded up by a physical time scale modification method, such as adjusting the motor speed of the cassett tape recorder, was used as the input signal. Physical modification that controled only the inter speed of the cassette tape player distorted the pitch period of the original speech. In this study, a real-time system was implemented so that the pitch-distorted speech was reconstructed back to the original by fractional sampling pitch shifting using an FIR filter, and this signal was time scale modified to match the cassette tape recorder motor speed using SOLA time-scale medification. In experiments using speech signals medifiedby the proposed method, results obtained using a 16-bit resolution ADSP2101 processor and using computer simulations employing floating point operations showed about the same average frame signal-to-noise ratio of about 20 dB.

  • PDF

Tele-metering

  • Hearte, L.O.
    • 전기의세계
    • /
    • v.2
    • /
    • pp.6-14
    • /
    • 1949
  • Telemetering may be described as the art of metering at a considerable distance those quantities which are ordinarily encountered in industry, and in the generation of electric power. It is in the production of electric power that telemetering is particularly important, for it permits the system operator, or load dispatcher, to have before him at all times a continuous graphic record of the power output of each individual generating station together with an automatically made continuous graphic record of the total system output. There desired individual graphic records may be obtained showing power flow in or out, on important tie lines, etc. Such arrangements have the very great advantage that loads may be assigned to each generating station so that the best over-all system economy may be obtained and the system operator at all times may see with his own eyes that loads scheduled are actually held at the various stations. Moreover, with such equipment, in the event of system or station trouble the load dispatcher can see exactly what station, or stations, are affected and to what extent, without having to get in touch with anyone by telephone. Decisions can, therefore, be quickly reached for rescheduling the load. One of the most accurate and reliable telemetering systems is based on the use of potentiometric circuits, the fundamentals of which are discussed below. A member of such telemetering systems have been installed for the Boston Edicon Co., Boston, Massachusetts, the Consolidated Edison Co. of New York City. The Public Service Gas & Electric Co. of Newark, new Jersey. The Philadelphia Electric Co. for Philadelphia, Pennsylvania, and the Pennsylvania Railroad Co. for their electrified zone between New York and Washington a distance of over 200 miles. The scale of the totalizing recorder for the New York area is 3,000,00 KW. That of the totalizing recorder for the Philadelphia area is 2,000,000 KW. The initial installation using this type of equipment described was placed in service for the Philadelphia Electric Co. in 1923. All of the original recording instruments are still in service, later instruments have been added to take care of additions to the power system and naturally these later recorders have incorporated in those refinements in design made since the earlier ones were manufactured. Many other installations of similar equipment have been made in the United States in various locations such as at St. Louis, on the West Coast, at Baltimore and in Washington, D.C. While the use of these basic potentiometric circuits involves the use of continuous metallic circuits of good insulation resistance and free of grounds, nevertheless, intermediate transmission links, involving and impulse method suitable for use on telephone Morse carrier channels is available. This same method may be employed on power line carrier systems and is also suitable for use on beam type microwave transmission. Many impulse type units are also used as a link in these potantiometric methods. For the sake of brevity a description is given only of these basic potentiometric circuits. If there is sufficient interest in Korea, a further paper can be given covering those impulse circuits also.

  • PDF

Dynamic Characteristics of Actuator for High Density Optical Recording Pick-up (고밀도 기록용 광픽업의 ACTUATOR 동특성)

  • 임경화;이용훈;김석중;이재원
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1995.04a
    • /
    • pp.258-263
    • /
    • 1995
  • 미래 정보와 시대에서 중추적인 역할을 할 광관련 멀티미디어 장비들은 최근 관련 산업계에서 주목을 받기 시작하고 있고 특히 기존 VTR(Video Tape Recorder) 시장을 대체할 차세대 DVDR(Digital Video Disk Recorder)는 기술전쟁이라고 할 정도로 선진 기업의 연구가 치열해지고 있다. DVDR 시스템에서는 필요한 정보들을 레이저빔을 이용한 광학신호로 바꾸어 광디스크에 기록, 재생하는 광픽업이 절대적으로 필요하게 된다. 그런데 광픽업의 위치추종기구인 Actuator는 정확한 위치추종(.+-.1.$\mu$m 오차이내)을 할 수 있는 성능이 요구되며 서보의 특성상 20KHz 이하에서 불필요한 모우드가 가진되지 않는 정밀부품이어야 하므로 Actuator 각 부품의 동적인 특성을 명확히 규명할 필요가 있다. 따라서 본 연구에서는 우선 Actuator 각 부품과 가동부 전체의 중량 및 진동해석을 통해 동특성을 조사하였다. 그리고 Actuator의 중요한 기본성능중 하나인 구동감도 확보여부를 검토할 필요가 있기 때문에 유한요소법 프로그램인 ANSYS를 이용하여 자기회로 부분에 대한 해석을 구하였다. 또한 가동부와 자기회로 등 하위부품을 조립하는 과정에서 발생하는 조립오차로 인해 불필요한 공진과 회전형상이 야기될 수 있으므로 동특성 및 문제점 파악을 위한 민감도 분석이 필요하다. 따라서 본 연구에서는 가동부의 관성 모멘트 값과 강체에 대한 일반식을 이용한 자체 프로그램을 작성하여 조립공차를 구하였다. 이와같은 과정을 통해 구해진 설계값을 바탕으로 실제 제작된 Actuator에 대해서는 비접촉식 측정방법을 통해 동특성값을 측정하였고 이를 해석값과 상호 비교하였다.동강성행렬법(dynamic stiffness matrix method)을 이용하여 해석하고자 한다. 수준임이 입증되었다. 본 연구의 결과를 토대로우리나라 젊고 건강한 남성에게 적합한 무게상수는 작업자군에 대하여 25.05kg, 학생군에 대하여 20.24kg 으로 나타나 이는 미국 NIOSH 안전기준과 대체로 일치함을 발견하였다.ive structures utilized in Client/server architecture for distribution and cooperative processing of application between server and client this study presents two different data management methods under the Client/server environment; one is "Remote Data Management Method" which uses file server or database server and. the other is "Distributed Data Management Method" using distributed database management system. The result of this study leads to the conclusion that in the client/server environment although distributed application is assumed, the data could become centralized (in the case of file server or database server) or decentralized (in the case of distributed

  • PDF

Response of Anchovy to Artificial Sounds (소리자극에 대한 멸치의 반응)

  • 김상한
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.14 no.2
    • /
    • pp.57-62
    • /
    • 1978
  • When fisherman use the boat seine net to catch anchovy, a large noise (drum can, small drum and small gong) is used to scare the anchovy school along the wing nets, and into the bag net were they are caught. We want to know how much of an effect these s:mnds have on forceing the anchovy school towards the bag net. The underwater sounds of ancho\'y, drum can, small drum and small gong were analyzed in the labroatory. The behavioral responeses to the playback sounds of anchovy feeding and sounds of artificial instruments were also investigated. The feeding and artificial sounds of the samples were recorded by a tape recorder through a hydrophone in an anechoic aquarium. The sound intensity level was measured by means of a sound level meter in an anechoic chamber. The frequency and intensity of various sounds were analyzed with an analyzing system consisting of a ~-octave filter set, a high speed level recorder, an amplifier and an oscilloscope. The most successful recording was edited into a 9 to 10 second sound track and was repeated in a sequence of 9 to 10 second intervals. The sequence was then reproduced into an anechoic aquarium through the underwater speaker. The results of investigation are as follows; 1. The frequency of the feeding sound was 63~80Hz, and the pressure level produced was less than 32db. 2. The frequencies of the artificial sounds were 315~ 1,OOOHz, and the pressure levels were 88~95 db in the air. 3. When a hydrophone was placed 70cm below the surface with artificial sounds (drum can, small drum and small gong) produced 1 meter above the surface, the pressure level decreased about 30db. 4. The feeding sound was ineffective in attracting the anchovy, because of interference from ambient noise. 5. The artificial sounds had such a small effect on the anchovy's that they could not be used in ocean fisheries.

  • PDF