• Title/Summary/Keyword: Recoil length

Search Result 15, Processing Time 0.016 seconds

A Study on Fe ions in the $\textrm{CdFe}_2\textrm{O}_4$ and $\textrm{CdFeAlO}_4$ by Mossbauer Spectroscopy (Mossbauer분광법을 이용한 $\textrm{CdFe}_2\textrm{O}_4$$\textrm{CdFeAlO}_4$의 Fe 이온에 관한 연구)

  • Baek, Seung-Do;Go, Jeong-Dae
    • Korean Journal of Materials Research
    • /
    • v.9 no.4
    • /
    • pp.345-348
    • /
    • 1999
  • The properties of Fe ions in the $ CdFe_2$$O_4$ and $CdFeAlO_4$ were investigated using the Mossbauer spectroscopy, in the temperature range from 300K to 900K. The calculated Debye temperature, recoil free fraction, mean square displacement and velocity are, 476.5K, 0.835, 3.39$\times$10\ulcorner$\textrm{cm}^2$, and 1.11$\times$10\ulcorner$\textrm{cm}^2$sec$^2$for Fe ions in the $CdFe_2$$O_4$ and 369.0K, 0.741, 5.65$\times$10\ulcorner$\textrm{cm}^2$ and 1.33$\times$10\ulcorner$\textrm{cm}^2$/$sec^2$in the $CeFeAlO_4$. The difference of the properties in the two samples were explained by the variation of the Fe\ulcorner-O\ulcorner bonding length with the substituted Al ions.

  • PDF

Operation Characteristic of Filtered Vacuum Arc Source for Amorphous Diamond Coating (비정질 다이아몬드 코팅을 위한 자장여과 아크소스의 동작 특성에 관한 연구)

  • kim, Jong-Guk;Lee, Gu-Hyeon
    • 연구논문집
    • /
    • s.30
    • /
    • pp.147-157
    • /
    • 2000
  • The filtered vacuum arc source (FVAS), which is adopted by magnetic filtering methode to remove the macro-particle in vacuum arc plasma, was composed of a torus structure with bending angle of 60 degree. The radius of torus was 266 mm, the radius of plasma duct was 80 mm and the total length was 600 mm. The magnet parts were consisted of one permanent magnet, one magnetic yoke and five solenoid magnets. The plasma duct was electrically isolated from the ground so that a bias voltage could be applied. The baffles inside plasma duct were installed in order to prevent the recoil effect of macro-particles. Graphite was used as the cathode material to coat the amorphic diamond film and its diameter was 80 mm. The amorphic diamond film attracts much attention due to its excellent mechanical, optical and tribological properties suitable for wide range of applications. The effects of solenoid magnet in plasma extraction were studied by computer simulation and experiment using Taguchi's method. The source and extraction magnet affected the arc stabilization. The extraction beam current was maximized with low value of the source magnet current and high value of the filtering magnet current. Optimum deposition condition was obtained when the currents of arc discharge, source, extraction, bending, deflection and outlet magnet were 30 A, 1 A, 3 A, 5 A, and 5 A, respectively.

  • PDF

Numerical simulation of localization of a sub-assembly with failed fuel pins in the prototype fast breeder reactor

  • Abhitab Bachchan;Puspendu Hazra;Nimala Sundaram;Subhadip Kirtan;Nakul Chaudhary;A. Riyas;K. Devan
    • Nuclear Engineering and Technology
    • /
    • v.55 no.10
    • /
    • pp.3648-3658
    • /
    • 2023
  • The early localization of a fuel subassembly with a failed (wet rupture) fuel pin is very important in reactors to limit the associated radiological and operational consequences. This requires a fast and reliable system for failure detection and their localization in the core. In the Prototype Fast Breeder Reactor, the system specially designed for this purpose is Failed Fuel Location Modules (FFLM) housed in the control plug region. It identifies a failed sub-assembly by detecting the presence of delayed neutrons in the sodium from a failed sub-assembly. During the commissioning phase of PFBR, it is mandatory to demonstrate the FFLM effectiveness. The paper highlights the engineering and physics design aspects of FFLM and the integrated simulation towards its function demonstration with a source assembly containing a perforated metallic fuel pin. This test pin mimics a MOX pin of 1 cm2 of geometrical defect area. At 10% power and 20% sodium flow rate, the counts rate in the BCCs of FFLM system range from 75 cps to 145 cps depending upon the position of DN source assembly. The model developed for the counts simulation is applicable to both metal and MOX pins with proper values of k-factor and escape coefficient.

Determinants of Successful Percutaneous Transluminal Coronary Angioplasty (경피적 관상동맥 성형술의 성공율에 영향을 미치는 인자에 대한 고찰)

  • Choi, Kyo-Won;Kweon, Jun-Young;Kim, Young-Jin;Lee, Tae-Il;Shin, Dong-Gu;Kim, Young-Jo;Shim, Bong-Seup;Lee, Hyun-Woo;Lee, Sam-Beom
    • Journal of Yeungnam Medical Science
    • /
    • v.11 no.2
    • /
    • pp.230-239
    • /
    • 1994
  • In Order to evaluate determinants of successful percutaneous transluminal coronary angioplasty (PTCA), PTCA was performed for 172 coronary arterial lesions in 120 patients (89 male, 31 female) at Yeungnam university hospital from Sep. 1992 to Aug. 1993. The corinary artery luminal diameter at the site of the original stenosis was eveluated from end-diastolic frames of identical projections of the preangioplasty and immediate post angioplasty. The coronary luminal and balloon diameters were measured with using of computer measuring system. Overall success rate of 172 attempted lesions was 87.2%. Success rate of female patients was 93.5% and higher than those of male patients. According to the clinical diagnosis, success rate in stable angina was 93.7% and higher than those of post myocardial infarction angina, unstable angina and acute myocardial infarcrion. Success rate of American Heart Association type C lesion was 65.5% and lower those of type A (95.7%), type B (89.5%). There was signfifcantly difference in preangioplasty luminal stenosis, elastic recoil and length of lesion between successful PTCA group and failed PTCA group. Success rate of lesion location at a bend > $45^{\circ}$ and presence of intracoronary thrombus were lower than than those of other angiographic findings. In coclusion, primary angioplasty success was affected by specific angiographic factors. Stenosis severity, thrombus, lesion location at a bend > $45^{\circ}$, elastic recoil, and length of lesion were the principle of determinants of coronary angioplasty success rate.

  • PDF

The effects of solenoid magnet on plasma extraction in Filtered Vacuum Arc Source (FVAS) (자장여과 아크 소스에서 각 전자석이 플라즈마 인출에 미치는 영향)

  • 김종국;변응선;이구현;조영상
    • Journal of the Korean Vacuum Society
    • /
    • v.10 no.4
    • /
    • pp.431-439
    • /
    • 2001
  • In this paper, the a-Diamond films were synthesized using filtered vacuum arc source (FVAS), FVAS was composed of a torus structure with bending angle of 60 degree. The radius of torus was 266 mm, the radius of plasma duct was 80 mm and the total length was 600 mm. The magnet parts were composed of one permanent magnet and five solenoid magnets. The plasma duct was electrically isolated from the ground so that a bias voltage could be applied. The baffles inside plasma duct were installed in order to prevent the recoil effect of macro-particles. Cathode was made of graphite with 80 mm in diameter. The effects of solenoid magnet on plasma extraction were investigated by computer simulation and experiment using Taguchi's methode. The source and extraction magnet affected the arc stabilization. The extraction beam current was maximized with low value of the source magnet current and high value of the filtering magnet current. The beam current density was 3.2 mA/$\textrm{cm}^2$ and average deposition rate was 5 $\AA$/sec when the currents of arc discharge, source, extraction, bending, deflection and outlet magnet were 30 A, 1 A, 3 A, 5 A, 5 A, and 5 A, respectively. The beam current density and the efficiency of beam transportation were increased with the positive bias voltage of the plasma duct.

  • PDF