• Title/Summary/Keyword: Recognition voltage

Search Result 71, Processing Time 0.025 seconds

A study on implementation digital programmable CNN with variable template memory (가변적 템플릿 메모리를 갖는 디지털 프로그래머블 CNN 구현에 관한 연구)

  • 윤유권;문성룡
    • Journal of the Korean Institute of Telematics and Electronics C
    • /
    • v.34C no.10
    • /
    • pp.59-66
    • /
    • 1997
  • Neural networks has widely been be used for several practical applications such as speech, image processing, and pattern recognition. Thus, a approach to the voltage-controlled current source in areas of neural networks, the key features of CNN in locally connected only to its netighbors. Because the architecture of the interconnection elements between cells in very simple and space invariant, CNNs are suitable for VLSI implementation. In this paper, processing element of digital programmable CNN with variable template memory was implemented using CMOS circuit. CNN PE circuit was designe dto control gain for obtaining the optimal solutions in the CNN output. Performance of operation for 4*4 CNN circuit applied for fixed template and variable template analyzed with the result of simulation using HSPICE tool. As a result of simulations, the proposed variable template method verified to improve performance of operation in comparison with the fixed template method.

  • PDF

A Novel Multi-Quantum Well Injection Mode Diode And Its Application for the Implementation of Pulse-Mode Neural Circuits (다중 양자우물 주사형 다이오드와 펄스-모드 신경회로망 구현을 위한 그 응용)

  • Song Chung Kun
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.31A no.8
    • /
    • pp.62-71
    • /
    • 1994
  • A novel semiconductor device is proposed to be used as a processing element for the implementation of pulse-mode neural networks which consists of alternating n' GaAs quantum wells and undoped AlGaAs barriers sandwitched between n' GaAs cathode and P' GaAs anode and in simple circuit in conjunction with a parallel capacitive and resistive load the trigger circuit generates neuron-like pulse train output mimicking the function of axon hillock of biological neuron. It showed the sigmoidal relationship between the frequency of the pulse-train and the applied input DC voltage. In conjunction with MQWIMD the various neural circuits are proposed especially a neural chip monolithically integrated with photodetectors in order to perfrom the pattern recognition.

  • PDF

A Hysteresis Current Controller for PV-Wind Hybrid Source Fed STATCOM System Using Cascaded Multilevel Inverters

  • Palanisamy, R.;Vijayakumar, K.
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.1
    • /
    • pp.270-279
    • /
    • 2018
  • This paper elucidates a hysteresis current controller for enhancing the performance of static synchronous compensator (STATCOM) using cascaded H-bridge multilevel inverter. Due to the rising power demand and growing conventional generation costs a new alternative in renewable energy source is gaining popularity and recognition. A five level single phase cascaded multilevel inverter with two separated dc sources, which is energized by photovoltaic - wind hybrid energy source. The voltages across the each dc source is balanced and standardized by the proposed hysteresis current controller. The performance of STATCOM is analyzed by connecting with grid connected system, under the steady state & dynamic state. To reduce the Total Harmonic Distortion (THD) and to improve the output voltage, closed loop hysteresis current control is achieved using PLL and PI controller. The performance of the proposed system is scrutinized through various simulation results using matlab/simulink and hardware results are also verified with simulation results.

Discrimination of insulation defects using a neural network (신경회로망을 이용한 절연 결함의 판별)

  • 최재관;김재환;김성홍;윤헌주;박재준
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1997.11a
    • /
    • pp.381-384
    • /
    • 1997
  • This paper describes the method of diagnosing the degradation by void defects of insulator inside in operation. Needle-shape void specimens, made from LDPE, were used to generate an electrical tree under ac voltage. The method uses a neural network system with input signal of AE patterns. AE pattern consists of the pulse count and average amplitude according to the phase angle. After the learning process was over, unknown emission patterns were put into the network. It was shown that the network discriminates the void deflects well. The effectiveness of the neural network system for partial discharge recognition was shown.

  • PDF

An analysis on Flicker Phenomenon of a Fluorescent lights for the commercial operating EMU (영업운행 전동차 객실형광등의 플리커(Flicker) 현상에 관한 분석 연구)

  • Ha, Jong-Eun;Han, Seon-Ho;Park, Jae-Hong;Lee, Dae-Won
    • Proceedings of the KSR Conference
    • /
    • 2006.11b
    • /
    • pp.1240-1246
    • /
    • 2006
  • Generally, there are two types of main factors to affect output power quality of a auxiliary power supply an EMU(electric multiple unit). One is a voltage flicker by amplitude modulation of short time and air compressors. The other is repetitive motion of large capacity motor such as air compressors, HVAC unit etc. in main factors. This paper compared two kinds of fluorescent lamp, 32W (after remodeling interior) and 40W(before remodeling interior) and measured the light output varying input power(AC220V) for a flicker phenomenon related power supply of lamps in EMU. Also, we analyzed a flicker considering EMU operating time and density in order to grasp main factors of a load change to cause a voltage change. As a results of test, a 40W fluorescent lamp was more insensitive with 20.26% degree an eye recognition degree sides about changes of the input power and lower with 19.9% voltage side generating flicker compare with fluorescent lamp 32W. Also, we confirmed the fact which the fluorescent lamp flicker was generated by varying fluorescent lamp output voltage when the commercial EMU was in high driving density and at the busy time. Additionally, we confirmed the frequency band which an EMU passenger could feel sensitively blinking of a fluorescent lamp was visually $8Hz{\sim}15Hz$.

  • PDF

The Study on the Actual Condition about Facility Accident Case and PL Recognition of the Safety Manager in Electric Installation for Private Use (수용가 전기설비 관리자의 PL인식 및 설비사고사례에 관한 실태연구)

  • Kim, Young-Seok;Shong, Kil-Mok;Jung, Jong-Wook;Jung, Jin-Su;Kim, Sun-Gu;Lee, Jun
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.309-312
    • /
    • 2008
  • In this paper, we investigated electric safety manager's PL recognition and accident occurrence of electric power facilities(power cable, transformer, circuit breaker) in electric installation for private use. The target of questionnaire survey is 450 electric installations for private use, 154 responded the questionnaire among these and it occupied 35.8%. Most of receiving voltage were 22.900kV. The questionnaire survey says that 58% of electric safety manager knew well about PL contents and 42% of them did not recognize about PL contents, About the PL application of electrical facility accidents, 82.4% of them must applied PL law, 5.8% of them did not need the PL law. Reason of PL application occupied 64% for stability of electrical facility and product, 19% for prevention of same accident. The accident of transformer occupied most and the power cable accident were much next. The questionnaire survey results, electric safety managers are interested in PL content. thev expected necessity of PL application about electrical accident strongly.

  • PDF

Study on Vehicle Haptic-Seat for the Information Transfer to Driver (운전자 정보전달을 위한 차량용 햅틱시트 연구)

  • Oh, S.Y.;Kim, K.T.;Yu, C.H.;Han, K.S.;Kwon, T.K.
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.8 no.1
    • /
    • pp.1-7
    • /
    • 2014
  • In this study, the effect of the automotive haptic-seat technology which can transmit the driving information by the vibro-stimulus from the seat was investigated to overcome previous system's limitation relied on the visual and audial method and to help handicap driving. A prototype haptic seat covers with 30 coin-type motors and driver module were developed for this sake. A driving simulator on the 6-DOF motion-base was used for driving situation and we executed the seat vibro-stimulus test with 10 young participants who have normal tactile sense. The haptic recognition ratio by 30 locations was measured and analyzed in the result. The intensity of vibro-stimulus was adjusted by input voltage of motors (1.5V,2.5V,3.5V). All vibro-stimulus locations at 2.5V and 3.5V could be recognized by all participants and even in the lowest recognition ratio of 1.5V. The results showed that the seat vibration stimulus could be useful to transfer the drivers' information while driving.

  • PDF

Sensor-based Recognition of Human's Hand Motion for Control of a Robotic Hand (로봇 핸드 제어를 위한 센서 기반 손 동작 인식)

  • Hwang, Myun Joong
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.15 no.9
    • /
    • pp.5440-5445
    • /
    • 2014
  • Many studies have examined robot control using human bio signals but complicated signal processing and expensive hardware are necessary. This study proposes a method to recognize a human's hand motion using a low-cost EMG sensor and Flex sensor. The method to classify movement of the hand and finger is determined from the change in output voltage measured through MCU. The analog reference voltage is determined to be 3.3V to increase the resolution of movement identification through experiment. The robotic hand is designed to realize the identified movement. The hand has four fingers and a wrist that are controlled using pneumatic cylinders and a DC servo motor, respectively. The results show that the proposed simple method can realize human hand motion in a remote environment using the fabricated robotic hand.

Fault Diagnosis of Voltage-Fed Inverters Using Pattern Recognition Techniques for Induction Motor Drive (패턴인식 기법을 이용한 유도전동기 구동용 전압형 인버터의 고장진단)

  • Park, Jang-Hwan;Park, Sung-Moo;Lee, Dae-Jong;Kim, Dong-Hwa;Chun, Myung-Geun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.19 no.3
    • /
    • pp.75-84
    • /
    • 2005
  • Since an unexpected fault of induction motor drive systems can cause serious troubles in many industrial applications, which the technique is required to diagnose faults of a voltage-fed PWM inverter for induction motor drives. The considered fault types are rectifier diodes, switching devices and input terminals with open-circuit faults, and the signal for diagnosis is derived from motor currents. The magnitude of dq-current trajectory is used for the feature extraction of a fault and PCA LDA are applied to diagnose. Also, we show results with respect to the execution time because of the possibility to use that a diagnosis software is embedded in the controllers of medium and small size induction motors drive for real-time diagnosis. After we performed various simulations for the fault diagnosis of the inverter, the usefulness of proposed algerian was verified.

The Crucial Role of the Establishment of Computed Tomography Density Conversion Tables for Treating Brain or Head/Neck Tumors

  • Yang, Shu-Chin;Lo, Su-Hua;Shie, Li-Tsuen;Lee, Sung-Wei;Ho, Sheng-Yow
    • Progress in Medical Physics
    • /
    • v.32 no.3
    • /
    • pp.59-69
    • /
    • 2021
  • Purpose: The relationship between computed tomography (CT) number and electron density (ED) has been investigated in previous studies. However, the role of these measures for guiding cancer treatment remains unclear. Methods: The CT number was plotted against ED for different imaging protocols. The CT number was imported into ED tables for the Pinnacle treatment planning system (TPS) and was used to determine the effect on dose calculations. Conversion tables for radiation dose calculations were generated and subsequently monitored using a dosimeter to determine the effect of different CT scanning protocols and treatment sites. These tables were used to retrospectively recalculate the radiation therapy plans for 41 patients after an incorrect scanning protocol was inadvertently used. The gamma index was further used to assess the dose distribution, percentage dose difference (DD), and distance-to-agreement (DTA). Results: For densities <1.1 g/cm3, the standard deviation of the CT number was ±0.6% and the greatest variation was noted for brain protocol conditions. For densities >1.1 g/cm3, the standard deviation of the CT number was ±21.2% and the greatest variation occurred for the tube voltage and head and neck (H&N) protocol conditions. These findings suggest that the factors most affecting the CT number are the tube voltage and treatment site (brain and H&N). Gamma index analyses for the 41 retrospective clinical cases, as well as brain metastases and H&N tumors, showed gamma passing rates >90% and <90% for the passing criterion of 2%/2 and 1%/1 mm, respectively. Conclusions: The CT protocol should be carefully decided for TPS. The correct protocol should be used for the corresponding TPS based on the treatment site because this especially affects the dose distribution for brain metastases and H&N tumor recognition. Such steps could help reduce systematic errors.