• 제목/요약/키워드: Recloser-recloser coordination

검색결과 32건 처리시간 0.028초

분산전원이 연계된 배전계통의 사고지점 확인 및 보호협조 방안 제시 (Fault location identification and protective coordination schemes presentation of distribution system interconnected Distributed Generation)

  • 최동만;최준호;노경수;문승일;김재철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.313-315
    • /
    • 2005
  • Recently There has been growing interest in new renewable energy systems with high-energy efficiency due to the increasing energy consumption and environmental pollution problems. But an insertion of new distributed generation to existng power distribution systems can cause several problems such as voltage variations, harmonics, protective coordination, increasing fault current etc, because of reverse power. This paper was applied to fault location defecting a method as each Relay sensing fault current value and carried out short-circuit analysis by MATLAB and PSCAD/EMTDC programs and identity the faulted section o f22.9[kV] distribution system interconnected a large number of distributed generation. The existing protection system of 22.9[kV] power distribution system analyzed and the study on protective coordination recloser and Sectionalzer accomplished

  • PDF

배전계통에 분산전원 연계시 기존 배전 계통측의 효과적인 리클로저 보호협조 연구 (A Study on the Effective Coordination Scheme of Recloser for the Conventional Distribution System Interconnected Dispersed Generation)

  • 정승복;김재철;문종필;윤상윤;최준호;배주천
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2002년도 하계학술대회 논문집 A
    • /
    • pp.533-535
    • /
    • 2002
  • In Korea, power requirement has been increasing. But the large generation unit is hardly installed because of economic and environment problem. Therefore, the concern of dispersed generation system(DGS) is growing. The power distribution system is generally operated with radial type. The protection system is composed of one directive source. But power distribution system inserted DGS changes it to two directive source system. Therefore, the insertion of DGS has the problem of protection coordination. In this paper, we argue fault current affected by interconnected DGS. We analyze fault current flow affected by DGS placement. Then, we find protective coordination problem. Consequently, we study advance point for protection scheme of power system interconnected DGS.

  • PDF

배전계통에 연계된 열병합발전 시스템의 개선된 보호협조 방안에 관한 연구 (Advanced Protective Coordination Schemes of Utility Interconnected Cogeneration Systems)

  • 최준호;정성교;추동욱;김낙경;손학식;김재철
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권6호
    • /
    • pp.280-288
    • /
    • 2000
  • Recently, there has been growing interest in utilizing cogeneration(COGN) systems with a high-energy efficiency due to the increasing energy consumption and the lacking of energy resource. But an insertion of COGN system to existing power distribution system can cause several problems such as voltage variations, harmonics, protective coordination, increasing fault current etc, because of reverse power of COGN, especially in protective coordination. A study on a proper coordination with existing one is being required. The existing power distribution system is operated with radial type by one source and protection system is composed based on unidirectional power source. But an Insertion of COGN system to power distribution system change existing unidirectional power source system to bidirectional power source. Therefore, investigation to cover whole field of power distribution system must be accomplished such as changing of protection devices rating by increasing fault current, reevaluation of protective coordination. In this paper, simulation using PSCAD/EMTDC was accomplished to analyze effect of COGIN on distribution fault current. Also, the existing protection system of 22.9[kV] power distribution system and customers protection system to protect of COGIN was analyzed and the study on protective coordination between of two protection system accomplished.

  • PDF

지중배전선로의 다회로차단기 운영방안 연구 (The Study of Multi-Circuit Breaker Coordination in the Underground Distribution Line)

  • 조남훈;하복남;이흥호
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제49권4호
    • /
    • pp.143-151
    • /
    • 2000
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the distribution line, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. On underground distribution line, the serving of cables by earth-moving equipment is a prevalent cause of faults and the most cable faults quickly develop into bolted current. we introduce th multi-circuit breaker coordination methods in the Underground Distribution Line.

  • PDF

지중배전선로의 고장전류 크기 및 보호협조분석 (Ananalzing fault current and Protective coordination in the underground line)

  • 조남훈;하복남;이중호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 C
    • /
    • pp.932-934
    • /
    • 1998
  • Electric power distribution feeders are susceptible to faults caused by a variety of situations such as adverse weather conditions, tree contacts, equipment failure, accidents, etc. Distribution circuit faults result in a number of problems related to the reliability of service and customer power quality. In the past, the permanent interruption of customer service resulting from a blown fuse or a recloser lockout was the only factor which was used to determine service reliability. So we developed KODAS(Korea Distribution Automation System) with successful and had fieid-testing of Distribution Automation System in last three years at Kang-dong Branch Office. In performing the project, KEPRI has gained valuable experience, through dealing with many difficult problem. This paper is depicted about the circuit breaker coordination problems in the Underground for the Distribution Automation Feeder.

  • PDF

분산전원이 연계된 배전계통에서 리크로저와 섹셔널라이저의 개선된 보호협조 방안 (The Advanced Recloser and Sectionalizer Coordination and Protection Scheme in Distribution System Interconnected Distributed Resources)

  • 정현준;최준호;남해곤;문채주
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.319-321
    • /
    • 2005
  • According to the second plan of the Korean Government about technology development, utilization and population of new renewable energy, the continuous growth of distributed resources are expected. But if those are interconnected with distribution system, there are many problem. In this paper, it is searched the biggest capacity of distributed resources under limit of actuating current o# protection devices and scheme.

  • PDF

분산전원수용가와 리클로즈의 보호협조 평가알고리즘 (Evaluation Algorithm for Coordination Protection Between Recloser and Distributed Generation Relay)

  • 김소희;허상운;노대석;서인용
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2011년도 춘계학술논문집 1부
    • /
    • pp.69-72
    • /
    • 2011
  • 정부의 녹생성장 정책에 의해서 신재생에너지들의 보급률이 지속적으로 증가되고 있는 실정이다. 특히 배전계통에 태양광/풍력발전 등 분산전원의 설치가 급증함에 따라 기존 배전계통의 조류흐름이 단방향(One direction)에서 양방향(Bi-direction)으로 변화 되어 배전계통의 운용상에 여러 가지 문제점들이 발생할 가능성이 커지고 있다. 따라서 본 논문에서는 분산전원의 배전계통 연계에 따른 보호기기의 정정 및 보호협조검토가 가능한 보호협조 평가알고리즘을 개발하고, 그 알고리즘을 바탕으로 보호협조 평가시스템을 제작하였다. 이 평가시스템에 분산전원 연계 시, 배전계통의 보호기기들 사이의 보호협조를 검토하여 제안한 알고리즘의 유효성을 확인하였다.

  • PDF

변전소릴레이와 리클로즈의 보호협조 평가알고리즘 (Evaluation Algorithm for Coordination Protection Between Substation Relay and Recloser)

  • 지성호;김소희;허상운;노대석
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2011년도 춘계학술논문집 1부
    • /
    • pp.17-20
    • /
    • 2011
  • 배전계통의 고장발생 시 광범위한 수용가에 정전파급을 일으킬 수 있으므로 신뢰성이 있는 보호협조의 설계가 매우 중요하다. 따라서 본 논문에서는 국내 22.9kV-y 배전계통에 연계된 보호기기들의 정정치와 보호협조 이상 유무를 확인할 수 있는 보호협조 평가알고리즘을 제시하고, 이 알고리즘을 이용하여 양방향 보호협조 평가시스템을 제작하였다. 본 연구에서 제작한 보호협조 평가시스템을 이용하여 배전용변전소의 보호기기(OCR, OCGR)와 배전선로에 설치되어 있는 보호기기(리클로즈)에 대하여 시뮬레이션을 수행하여, 제안한 알고리즘이 배전선로의 보호협조 및 안정화에 크게 기여할 수 있음을 확인하였다.

  • PDF

배전선로보호기기(리클로즈)와 고객계전기의 보호협조 평가알고리즘 (Evaluation Algorithm for Coordination Protection Between Recloser and Customer Relay)

  • 허상운;김소희;지성호;노대석
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2011년도 춘계학술논문집 1부
    • /
    • pp.21-24
    • /
    • 2011
  • 배전계통의 고장 발생 시 광범위한 수용가에 정전파급을 일으킬 수 있으므로 신뢰성이 있는 보호협조의 설계가 매우 중요하다. 따라서 배전계통의 보호협조는 선로고장으로 인한 정전범위를 최소화할 수 있는 시스템으로 설계되어야 한다. 본 논문에서는 국내 22.9kV-y 배전계통에 연계된 보호기기들의 정정치와 보호협조 이상 유무를 확인할 수 있는 보호협조 평가알고리즘을 제시하고, 이 알고리즘을 이용하여 양방향 보호협조 평가시스템을 제작하였다. 그리고 이 평가시스템을 이용하여 배전계통을 모델링하고 보호협조를 검토하여, 제안한 알고리즘이 배전선로의 보호협조 및 안정화에 크게 기여할 수 있음을 확인하였다.

  • PDF

The Inter-tie Protection Schemes of the Utility Interactive Dispersed Generation Units for Distribution Automatic Reclosing

  • Park, Joon-Ho;Kim, Jae-Chul;Moon, Seung-Il
    • KIEE International Transactions on Power Engineering
    • /
    • 제2A권4호
    • /
    • pp.166-173
    • /
    • 2002
  • Dispersed Generation (DG) units significantly effect the existing distribution protection practices. Therefore, new protection practices of the distribution system interconnected with DG units should be reevaluated and developed. In this paper, a new inter-tie protection scheme of DG units for distribution automatic reclosing is proposed. The impact of DG units on existing radial-sectionaliser coordination is analyzed. And the effects of the distribution reclosing type (radial and passive reclosing) on DG dynamics are analyzed and classified. From the results of the DG dynamic responses by the reclosing type, i.e. radial and passive reclosing, the inter-tie protection schemes of DG are introduced to improve the reliability and availability of utility interactive DG. The proposed schemes are proved and evaluated by a case study using PSCAD/EMTDC simulation.