• 제목/요약/키워드: Reclaimed water

검색결과 395건 처리시간 0.03초

인공 매립 지반에서의 지진파 증폭 특성 (Seismic Motion Amplification Characteristics at Artificial Reclaimed Land)

  • 김용성;문용
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1134-1139
    • /
    • 2005
  • Seismic motion amplification owing to the input motion level at bedrock is one of the important topics to understand various geomaterials behavior. The extremely valuable borehole records at Port Island were obtained during the 1995 Hyogoken Nanbu Earthquake and also before and after the main event. In this study, the seismic motion amplification at the soft reclaimed ground was discussed. Comparison of measured records with numerical simulation results were made with focus on seismic motion amplification characteristics at the soft reclaimed ground.

  • PDF

간척지대에 매설된 대구경 금속관의 외면 부식손상 평가 (Assessment of external corrosion deterioration of large diameter metallic water pipes buried in reclaimed land)

  • 이호민;최태호;김정현;배철호
    • 상하수도학회지
    • /
    • 제34권5호
    • /
    • pp.373-383
    • /
    • 2020
  • The purpose of this study was to evaluate the corrosion damage of large diameter metallic pipes buried in reclaimed land due to the corrosion effect by soil, and to propose a method of installing metal pipes in the reclaimed land. The results are as follow. First, the soil of the reclaimed land was gray clay, the soil specific resistance indicating soil corrosiveness was at least 120 Ω-cm, the pH was weakly acidic(5.04 to 5.60), the redox potential was at least 62 mV, the moisture content was at most 48.8%, and chlorine ions and sulfate ions were up to 4,706.1 mg/kg and 420 mg/kg. Therefore, the overall soil corrosivity score was up to 19, and the external corrosion effect seems to be very large. Second, the condition of straight part of pipes was in good condition, but most of KP joints were affected by corrosion at a severe level. The reason for this seems to be that KP joints accelerated corrosion due to stress and crevice corrosion in addition to galvanic corrosion in the same environment. Third, as a result of evaluating correlations of each item that affects the corrosion on the external part, the lower the soil resistivity and redox potential, the greater the effect on the KP joints corrosion, and the moisture content, chloride ion, and sulfate ion, the higher the value, the greater the effect on the corrosion of KP joints. In addition, among soil corrosion items, the coefficient of determination of soil resistivity with corrosion of KP joints was the highest with 0.6439~0.7672. Fourth, when installing metal pipes or other accessories because the soil of the reclaimed land is highly corrosive, it is necessary to apply a corrosion preventive method to extend the life of pipes and prevent leakage accidents caused by corrosion damage to the joint.

간척지 토양의 제염과정 중 전기전도도 분석 (Analysis of Electrical Conductivity during Desalinization of Reclaimed Tidal Lands)

  • 구자웅;최진규;손재권;윤광식;이동욱;조경훈
    • 한국농공학회지
    • /
    • 제43권4호
    • /
    • pp.37-49
    • /
    • 2001
  • This study was performed in order to produce the basic data for developing prediction techniques of desalinization to be applicable to reclaimed tidal lands at the beginning stage. the desalinization experiments were carried out by two water management practices, namely, the leaching method by subsurface drainage and the rinsing method by surface drainage. The 5 soil samples used in this study were collected in 4 tidal land reclamation projects. Regression equations were obtained in order to investigate the changes of electrical conductivity during the desalinization of reclaimed tidal lands and to estimate water requirements for desalinization. The results obtained from this study were summarized as follows: 1. According to USDA Salinity Laboratory classification system of salt affected soils the reclaimed tidal land soils used in this study were saline-sodic soils with the high electrical conductivity and the high exchangeable sodium percentage. 2. With the increase of the water requirements for desalinization the electrical conductivity was decreased with high degree of correlationships and the desalinization effects were remakable in both the leaching method and the rinsing method. 3. In case of the leaching method the electrical conductivity had been reduced below the classification value of salt affected soils when the depth o water leached per unit depth of soil (Dwl/Ds) was 0.3 and the desalinization effects showed a tendency to be much the same in each treatment.

  • PDF

건축물의 중수도 설치기준에 대한 제도적 개선방안 (An Institutional Improving Standards for Water Reclamation/Reuse(WRR) System Establishment to Buildings)

  • 공영효
    • KIEAE Journal
    • /
    • 제6권3호
    • /
    • pp.43-48
    • /
    • 2006
  • This paper aims to suggest ways of institutionally improving standards that must be applied when installing Water Reclamation/Reuse (WRR) system based on efficiency analysis. Currently, the standard for WRR system establishment requires that the system should treat more than 10% of used water in the building of over $60,000m^2$ in total area of all floors, but our research has found that it would be more effective to change the standard to $150-m^3-per-day$ reclaimed water or the total area of all floors of $30,000m^2$ ($50,000m^2$ in the case of an office building). In other words, what this paper suggests is not a one-size-fits-all standard based on the total area of all floors, but a reasonable and flexible standard that takes into account efficiency and a unit water usage according to a building's purpose. Furthermore, this paper recommends a new WRR standard that can be applied to large-scale land development for housinglots, like the New Town. The recommendation is based on the economic analysis that the WRR system will ensure efficiency only if the amount of reclaimed water is over 4,000 tons per day, which corresponds to 4 millions square meters of housinglots. Regarding the size of the established facility, this paper suggests changing the standard, which is now set at over 10% of water usage, to what is relative to the total amount of use of reclaimed water in order to ensure efficiency and promote use of reclaimed water. In addition, this paper proposes that governmental support should be offered not only to facility owners, who are recipients at present, but also to facility builders. By doing so, those who donate a facility to the government, central or local, after building it, can be provided with substantial aid. Therefore, the application of the institutional improvement suggested in this paper is expected to create environment-friendly living conditions and boost the quality of life by encouraging people to secure water resources efficiently in buildings, and in a wider range, in cities.

서산 간척지의 염도와 벼의 생육에 관한 연구 (Studies on Salinity and Growth of Rice at Seosan Reclaimed Land)

  • 이희선;김옥봉
    • The Korean Journal of Ecology
    • /
    • 제20권5호
    • /
    • pp.367-373
    • /
    • 1997
  • The effects of salinity on the growth and production of rice were studied at Seosan reclaimed land from July to October, 1995. The plant height, the number of living aleaves, dead leaves and total leaves, the number of the grains and the dry weight of the grains per individual, and the dry weight of above the ground in $25cm{\times}25cm$ quadrat were investigated on 5 plots whers were different salinity. The plant height, the number of living leaves and total leaves and the number of grains and the dry weight of grains per individual, and the dry weight of above the ground decreased as the salinity of water increase and the number of dead leaves of rice increased as the salinity of water decrease. The effect of salinity on the reproductive production is severer than the vegetative production. Because of the salinity, the growth and the production of the rice at Seosan reclaimed land are worse than the normal rice field.

  • PDF

하수처리수의 농업용수 재이용이 토양 및 작물의 중금속 함량에 미치는 영향 분석 (Impact of Reclaimed Wastewater Irrigation on Heavy Metal Contamination in Soil and Vegetables)

  • 김학관;장태일;이은정;박승우
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2008년도 학술발표회 논문집
    • /
    • pp.827-831
    • /
    • 2008
  • In this study, the effects of reclaimed wastewater irrigation on the concentration of heavy metals such as lead, zinc, cadmium, and copper in soil and vegetables were investigated by monitoring an experimental area irrigated with reclaimed wastewater. Three treatments and three replications on $10{\times}2$-m plots were installed and heavy metal concentrations in soil and vegetables were monitored from 2005 to 2007. The treatments applied in this study were groundwater irrigation (control treatment), wastewater irrigation, and irrigation with filtered reclaimed wastewater treated with ultraviolet light. The monitored results showed that the concentrations of Cu, Cd, and Pb in soil during the experimental period were lower than initial soil levels before irrigation, whereas Zn increased in all treatment plots. However, the ranges of Zn, Cu, Cd and Pb in soil were below the soil pollution standards in the Republic of Korea. Heavy metal concentrations in vegetables showed insignificant variations for all treatments.

  • PDF

오수처리수의 관개가 벼의 생육 및 수확량에 미치는 효과(지역환경 \circled3) (Effect of Reclaimed Sewage Irrigation on Paddy Rice Culture and Yields)

  • 우선호;윤춘경
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 2000년도 학술발표회 발표논문집
    • /
    • pp.611-616
    • /
    • 2000
  • Effect of reclaimed sewage on the paddy rice culture was examined by field experiment for two consecutive years. The domestic sewage was treated by the comstructed wetland, and the effluent of the treatment wetland was used for irrigation water. Growth components and yields were compared against the CONTROL plot where conventional fertilization was applied. In general, addition of the reclaimed sewage irrigation which contained high nutrient concentration didn't affect paddy rice culture adversely, and even better growth and more yields were observed. Overall, reclaimed sewage irrigation was thought to be one of practical alternatives for irrigation water.

  • PDF

도시 단지내 환경 인프라 재생 효과 고찰 - 대전시 M 아파트 단지 사례연구 (Effects of Environmental Infrastructure Regeneration in Urban Region - A Case Study of M Apartment Complex in Daejeon)

  • 박기용;최창규;신종석;박희경
    • 대한토목학회논문집
    • /
    • 제35권2호
    • /
    • pp.353-359
    • /
    • 2015
  • 본 연구는 실제 아파트 단지의 재생이 필요한 환경 인프라를 경제적이고 효율적인 녹색 인프라 기술로 재생하기 위한 계획을 수립하였으며, 단지내 물과 폐기물의 자원 순환 및 재이용을 위해 단지형 도시 중수 생산 기술과 단지형 유기성 폐기물 에너지화 기술, 무막힘 탄성포장 우수 재이용 기술, 도시농장 기술을 현장에 적용한 결과를 보여주고 있다. 도심 중수 생산 기술은 하수, 우수, 지하수를 대상으로 중수를 생산하여 단지내 공공용수로 이용하기 위한 기반 기술이며, 무막힘 탄성포장 우수배수구 기술은 단지 내에서 우수의 재이용율 극대화시키기 위한 기반 기술이다. 유기성 폐기물 에너지화 기술은 단지에서 발생하는 음식폐기물 및 분뇨 등의 유기성 폐기물을 처리하는 과정에서 바이오가스와 비료를 만들어 에너지원으로 활용할 수 있으며, 도시농장은 재생용수, 재생에너지, 재생비료를 활용하여 주거민들의 건강 및 여가공간으로 활용할 수 있는 기반기술이다. 이를 통해 단지 내에서 자원 순환 및 재이용이 가능한 하나의 에코시스템을 구축하였으며, 재생 후 녹색지표결과에서 에너지 부문은 4.23, 물부문은 0.32, 폐기물 부문은 0, 토지이용 부문은 0, 환경부문은 2.12가 상승하는 결과를 가져올 수 있었다.

간척지 밭작물의 관개용수량 추정을 위한 토양염분예측모형 개발 (Soil Salt Prediction Modeling for the Estimation of Irrigation Water Requirements for Dry Field Crops in Reclaimed Tidelands)

  • 손재권;구자웅;최진규
    • 한국농공학회지
    • /
    • 제36권2호
    • /
    • pp.96-110
    • /
    • 1994
  • The purpose of this study is to develop soil salt prediction model for the estimation of irrigation water requirements for dry field crops in reclaimed tidelands. The simulation model based on water balance equation, salt balance equation, and salt storage equation was developed for daily prediction of sa]t concentration in root zone. The data obtained from field measurement during the growing period of tomato were used to evaluate the applicability of this model. The results of this study are summarized as follows: 1.The optimum irrigation point which maximizes the crop yield in reclaimed tidelands of silt loam soil while maintaining the salt concentration within the tolerance level, ws found to be pF 1.6, and total irrigation requirement after transplanting was 602mm(6.7 mm/day)for tomato. 2.When the irrigation point was pF 1.6, the deviation between predicted and measured salt concentration was less than 4 % at the significance level of 1 7% 3.Since the deviations between predicted and measured values data decrease as the amount of irrigation water increases, the proposed model appear to be more suitable for use in reclaimed tidelands. 4.The amount of irrigation water estimated by the simulation model was 7.2mm/day in the average for cultivating tomato at the optimum irrigation point of pF 1.6.The simulation model proposed in this study can be generalized by applying it to other crops. This, model, also, could be further improved and extended to estimate desalinization effects in reclaimed tidelands by including meteorological effect, capillary phenomenon, and infiltration.

  • PDF

재처리수 관개후 지표미생물의 농도변화 조사 (Investigation of Indicator Microorganism Concentrations after Reclaimed Water Irrigation in Paddy Rice Pots)

  • 정광욱;윤춘경;장재호;김형철;전지홍
    • 한국농공학회논문집
    • /
    • 제47권4호
    • /
    • pp.75-85
    • /
    • 2005
  • A study was performed to examine the effects of reclaimed-water irrigation on microorganism con-centration in ponded-water of paddy rice plots. Several treatments were used and each one was triplicated to evaluate the change of indicator microorganisms (total coliforms (TC), fecal coliforms FC), and E. coli) concentrations in 2003 and 2004 growing seasons. Their concentrations increased significantly right after irrigation, but decreased about $45\%$ in 24 hours. It implies that agricultural activities such as plowing and fertilizing should be practiced one or two days after irrigation considering health-risks. Treatments with UV-disinfected water irrigation demonstrated significantly lower concentrations than others including control plots where natural surface water was irrigated. The monitoring results from actual paddy rice fields and experimental paddy plots showed that concentrations of indicator microorganisms ranged from $10^2\;to\;10^5$ MPN/100mL. A comprehensive assessment of existing agricultural practices and a thorough monitoring in the field as well as treatment-plots are recommended to make more realistic national guidelines more applicable. UV-disinfected water irrigation reduced microorganism concentrations in paddy fields down to below the concentration of conventional paddy rice culture, and is thought to be an effective and feasible measure fur agricultural reuse of secondary effluent.