• Title/Summary/Keyword: Recirculation system

Search Result 419, Processing Time 0.034 seconds

Intelligent Tuning of the Two Degrees-of-Freedom Proportional-Integral-Derivative Controller On the Distributed Control System for Steam Temperature Control of Thermal Power Plant

  • Dong Hwa Kim;Won Pyo Hong;Seung Hack Lee
    • KIEE International Transaction on Systems and Control
    • /
    • v.2D no.2
    • /
    • pp.78-91
    • /
    • 2002
  • In the thermal power plant, there are six manipulated variables: main steam flow, feedwater flow, fuel flow, air flow, spray flow, and gas recirculation flow. There are five controlled variables: generator output, main steam pressure, main steam temperature, exhaust gas density, and reheater steam temperature. Therefore, the thermal power plant control system is a multinput and output system. In the control system, the main steam temperature is typically regulated by the fuel flow rate and the spray flow rate, and the reheater steam temperature is regulated by the gas recirculation flow rate. However, strict control of the steam temperature must be maintained to avoid thermal stress. Maintaining the steam temperature can be difficult due to heating value variation to the fuel source, time delay changes in the main steam temperature versus changes in fuel flow rate, difficulty of control of the main steam temperature control and the reheater steam temperature control system owing to the dynamic response characteristics of changes in steam temperature and the reheater steam temperature, and the fluctuation of inner fluid water and steam flow rates during the load-following operation. Up to the present time, the Proportional-Integral-Derivative Controller has been used to operate this system. However, it is very difficult to achieve an optimal PID gain with no experience, since the gain of the PID controller has to be manually tuned by trial and error. This paper focuses on the characteristic comparison of the PID controller and the modified 2-DOF PID Controller (Two-Degrees-Freedom Proportional-Integral-Derivative) on the DCS (Distributed Control System). The method is to design an optimal controller that can be operated on the thermal generating plant in Seoul, Korea. The modified 2-DOF PID controller is designed to enable parameters to fit into the thermal plant during disturbances. To attain an optimal control method, transfer function and operating data from start-up, running, and stop procedures of the thermal plant have been acquired. Through this research, the stable range of a 2-DOF parameter for only this system could be found for the start-up procedure and this parameter could be used for the tuning problem. Also, this paper addressed whether an intelligent tuning method based on immune network algorithms can be used effectively in tuning these controllers.

  • PDF

Feasibility Study of Applying EMMC Process to Recirculation Water Treatment System in High Density Seawater Aquaculture Farm through Laboratory Scale Reactor Operation (실험실규모 반응조 운전을 통한 고밀도 해산어 양식장 순환수 처리공정으로서 EMMC공정의 적용 가능성 연구)

  • Jeong Byung Gon;Kim Byung Hyo
    • Journal of the Korean Society for Marine Environment & Energy
    • /
    • v.7 no.3
    • /
    • pp.116-121
    • /
    • 2004
  • Treatability tests were conducted to study the feasibility of EMMC process as a recycling-water treatment system in high density seawater aquaculture farm. To study the effect of organic and ammonia nitrogen loading rate on system performance, hydraulic retention time was reduced gradually from 12hr to 10min. The conclusions are can be summarized as follows. When the system HRT was reduced from 12hr to 2hr gradually, there was little noticeable change(reduction) in ammonia nitrogen removal efficiencies. However, removal efficiencies were decreased dramatically when the system was operated under the HRT of less than 2hr. In case of organics(COD), there was no dramatic change in removal efficiencies depending on HRT reduction. COD removal efficiencies were maintained successfully higher than 9% when the system was operated at tile HRT of 10 min. System performances depending on media packing ratio in the reactors were also evaluated. There were little differences in each reactor performances depending on media packing ratio in reactor when the reactors were operated under the HRT of longer than 1hr. However, differences in reactor performances were considerably evident when the reactors were operated under the HRT of shorter than 1hr. When comparing reactor performance among 25%, 50%,7 5% packed reactor, it can be judged that media packing ratio more than 50% plays no significant role in increasing reactor performance. For this reason, packing the media less than 50% is more reasonable way in view of economic. Such a tendency shown in COD removal efficiencies well agreed with the variation of ammonia-nitrogen removal efficiencies according to the media packing ratio in reactors at each HRT. Difference in effluent ammonia-nitrogen concentration between 50% media packing reactor and 75% media packing reactor was negligible. When comparing with the results of 25% packing reactor, difference was not so great.

  • PDF

Operating Characteristics of 1 $Nm^3/h$ Scale Synthetic Natural Gas(SNG) Synthetic Systems (1 $Nm^3/h$ 규모 합성천연가스(SNG) 합성 시스템의 운전 특성)

  • Kim, Jin-Ho;Kang, Suk-Hwan;Ryu, Jae-Hong;Lee, Sun-Ki;Kim, Su-Hyun;Kim, Mun-Hyun;Lee, Do-Yeon;Yoo, Yong-Don;Byun, Chang-Dae;Lim, Hyo-Jun
    • Korean Chemical Engineering Research
    • /
    • v.49 no.4
    • /
    • pp.491-497
    • /
    • 2011
  • In this work, we proposed the three different reactor systems for evaluating of synthetic natural gas(SNG) processes using the synthesis gas consisting of CO and $H_2$ and reactor systems to be considered are series adiabatic reaction system, series adiabatic reaction system with the recirculation and cooling wall type reaction system. The maximum temperature of the first adiabatic reactor in series adiabatic reaction system raised to 800. From the these results, carbon dioxide in product gas as compared to other systems was increased more than that expected due to water gas shift reaction(WGSR) and the maximum $CH_4$ concentration in SNG was 90.1%. In series adiabatic reaction system with the recirculation as a way to decrease the temperature in catalyst bed, the maximum $CH_4$ concentration in SNG was 96.3%. In cooling wall type reaction system, the reaction heat is absorbed by boiling water in the shell and the reaction temperature is controlled by controlling the amount of flow rate and pressure of feed water. The maximum $CH_4$ concentration in SNG for cooling wall type reaction system was 97.9%. The main advantage of the cooling wall type reaction system over adiabatic systems is that potentially it can be achieve almost complete methanation in one reactor.

Study on Numerical Simulation Using Body-fitted Corrdinate System for Complex Terrain (복잡 지표경계 영역에서 경계 일치 좌표계를 이용한 수치 시뮬레이션에 관한 연구)

  • 홍정혜
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.16 no.4
    • /
    • pp.339-350
    • /
    • 2000
  • The three-dimensional new corrdinate system over a single hill double hills and complex terrain with a single hill and a rectangular obstacle was generated using a body-fitted coordinate system. Control of the coordinate line distribution in the field was executed by generalizing the elliptic generating system to Poisson equation. ▽2ξ=P. The new coordinate system was well fitted to the surface boundary of single hill and double hills. But in the case of complex terrain with hill and rectangular obstacle there was smoothing tendency around the rectangular obstacle. In order to show the validity of the body-fitted coordinate system the heat diffusion equation was transformed and the temperature distribution was calculated over the various terrain. The results showed the temperature distribution was very symmetrical and stable around hills and obstacle. As a result the couple of a body-fitted coordinate system and the heat diffusion equation were executed successfully. Wind field over complex terrain with hill and rectangular obstacle which represent urban area was simulated stably in body-fitted coordinate system. The qualitative result show the enhancement of wind speed at the upwind direction of a hill and a rectangular obstacle and the recirculation zone at the downwind direction.

  • PDF

Flow Visualization in the Branching Duct by Using Particle Imaging Velocimetry (입자영상유속계를 이용한 분기관내 유동가시화)

  • No, Hyeong-Un;Seo, Sang-Ho;Yu, Sang-Sin
    • Journal of Biomedical Engineering Research
    • /
    • v.20 no.1
    • /
    • pp.29-36
    • /
    • 1999
  • The objective of this study is to analyse the flow field in the branching duct by visualizing the flow phenomena using the PIV system. A bifurcation model is fabricated with transparent acrylic resin to visualize the whole flow field with the PIV system. Water was used as the working fluid and the conifer powder as the tracer particles. The single-frame and two-frame methods of the PIV system and 2-frame of the grey level correlation method are applied to obtain the velocity vectors from the images captured in the flow filed. The velocity distributions in a lid-driven cavity flow are compared with the so-called standard experimental data, which was obtained from by 4-frame method in order to validate experimental results of the PIV measurements. The flow patterns of a Newtonian fluid in a branching duct were successfully visualized by using the PIV system and the sub-pixel and the area interpolation method were used to obtain the final velocity vectors. The velocity vectors obtained from the PIV system are in good agreement with the numerical results of the 3-dimensional branch flow. The results of numerical analyses and the PIV experiments for the three-dimensional flows in the branch ing duct show the recirculation zone distal to the branching point and the sizes of the recirculation length and height of the tow different methods are in good agreement.

  • PDF

Intelligent 2-DOF PID Control For Thermal Power Plant Using Immune Based Multiobjective

  • Kim, Dong-Hwa
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2003.10a
    • /
    • pp.1371-1376
    • /
    • 2003
  • In the thermal power plant, the main steam temperature is typically regulated by the fuel flow rate and the spray flow rate, and the reheater steam temperature is regulated by the gas recirculation flow rate. However, Strictly maintaining the steam temperature can be difficult due to heating value variation to the fuel source, time delay changes in the main steam temperature, the change of the dynamic characteristics in the reheater. Up to the present time, PID Controller has been used to operate this system. However, it is very difficult to achieve an optimal PID gain with no experience, since the gain of the PID controller has to be manually tuned by trial and error. This paper focuses on tuning of the 2-DOF PID Controller on the DCS for steam temperature control using immune based multiobjective approach. The stable range of a 2-DOF parameter for only this system could be found for the start-up procedure and this parameter could be used for the tuning problem. Therefore tuning technique of multiobjective based on immune network algorithms in this paper can be used effectively in tuning 2-DOF PID controllers.

  • PDF

Intelligent Control of Power Plant Using Immune Algorithm Based Multiobjective Fuzzy Optimization

  • Kim, Dong-Hwa
    • Proceedings of the Korean Institute of Intelligent Systems Conference
    • /
    • 2003.09a
    • /
    • pp.525-530
    • /
    • 2003
  • This paper focuses on design of nonlinear power plant controller using immune based multiobjective fuzzy approach. The thermal power plant is typically regulated by the fuel flow rate, the spray flow rate, and the gas recirculation flow rate. However, Strictly maintaining the steam temperature can be difficult due to heating value variation to the fuel source, time delay changes in the main steam temperature. the change of the dynamic characteristics in the steam-turbine system. Up to the present time, PID Controller has been used to operate this system. However, it is very difficult to achieve an optimal PID gain with no experience, since the gain of the PID controller has to be manually tuned by trial and error. These parameters tuned by multiobjective based on immune network algorithms could be used for the tuning of nonlinear power plant.

  • PDF

Numerical Analysis on Flow Field Around a Bluff Body by LES(I) (LES에 의한 사각형 Bluff Body 주위 유동장 수치해석(I))

  • Jang, D.S.;Lee, Y.W.;Doh, D.H.;Bae, D.S.;Kim, N.S.
    • Journal of Power System Engineering
    • /
    • v.4 no.3
    • /
    • pp.40-47
    • /
    • 2000
  • The turbulent flow with wake, reattachment and recirculation flow is very important from the viewpoint of engineering. But that is still difficult because of especially the unsteady problems which are related with the vehicle dynamics and the aerodynamics noise. This paper evaluate LES that can analyze about all fluid flow region including the laminar, transition and turbulent. So we compare the results of LES with those of PIV measurement and Reynolds averaging models. In conclusion, LES predicts flow behavior better than Reynolds averaging models.

  • PDF

Sand Culture Using Recirculated Aquaculture Water (양어사육수를 이용한 사경재배)

  • 김기덕;이병일;강용구;문보흠;홍상근;홍석우;배용수
    • Korean Journal of Organic Agriculture
    • /
    • v.8 no.1
    • /
    • pp.79-88
    • /
    • 1999
  • In order top investigate the growth of water dropwort grown by sandculture irrigated with recirculated tilapia aquaculture water, these experiments were carried out. Fish(tilapia) production and biofiltration provided by sand cultured water dropwort(Oenanthe stolonifera DC.) were linked in a closed system of recirculation water. Water dropwort was irrigated with water drawn from the tilapia tank and drainage from sand beds was returned to the fish tank. The temperature, pH and EC of tilapia culture water were stable. The growth of water dropwort grown by sandculture with aquaculture water was normal. Microbial activity of the biofilterbed irrigated by tilapia rearing water was higher than that of biofilterbed irrigated by tapwater. The feasibility of an integrated, recirculatory system for concurrent production of water dropwort and fish with no additional fertilization application was demonstrated.

  • PDF

An Experimental Study on the Development of E-EGR Valve for Light Duty Diesel Engine (소형 디젤엔진용 E-EGR밸브 개발에 관한 실험적 연구)

  • Song, Chang-Hoon;Woo, Se-Jong;Lee, Jin-Wook;Jeong, Young-Il;Cha, Kyung-Ok
    • Proceedings of the KSME Conference
    • /
    • 2001.11b
    • /
    • pp.928-933
    • /
    • 2001
  • EGR(Exhaust Gas Recirculation) is an effective strategy to control nitrogen oxides emissions from diesel engine. The EGR reduces $NO_x$ through lowering the oxygen concentration in the combustion chamber as well as through heat absorption. However, application of EGR system is difficult because of the penalty in fuel consumption and the increase in particulate matter. The engine used for the experimental was a 3-cylinder 0.8-liter turbo-charged light duty diesel engine with an electronic EGR valve. In this study, experiments were performed at variable vehicle speeds and loads on the chassis dynamometer. To evaluate the exhaust emissions with the EGR system testing was performed using cvs-75 mode test procedure. Results of the cvs-75 mode test achieve sufficiently to meet EURO3 standards.

  • PDF