• Title/Summary/Keyword: Reciprocating Hydrogen Compressor

Search Result 17, Processing Time 0.025 seconds

Snubber Analyzation and Vibration Measurement Estimation of Reciprocating Type Hydrogen Compressor (왕복동식 수소압축기의 완충기 해석 및 진동 측정 평가)

  • Jeong, J.H.;Lim, J.I.;Kim, H.J.;Choi, B.K.
    • Proceedings of the KSME Conference
    • /
    • 2008.11a
    • /
    • pp.932-937
    • /
    • 2008
  • The pulsation of a reciprocating type hydrogen compressor is occurred from the mechanism and this pulsation makes much noise and vibration. To reduce this pulsation, snubber is usually installed on that. To maintain the efficiency in the reciprocating type hydrogen compressor, the pulsation and vibration should be reduced. so it is necessary to research about the characteristic of pulsation and vibration. Therefore in this paper, the vibration characteristic of the snubber is analyzed in the base of optimized modeling condition through the flowing analysis of existing snubber. The prototype of reciprocating type hydrogen compressor is analyzed with numerical analysis. And making sure the present condition of hydrogen compressor through measurement of vibration and noise, and then it is established that the vibration characteristic data base on numerical analysis which will be develope.

  • PDF

Vibration Analysis of Reciprocating Hydrogen Compressor (왕복동 수소 압축기의 진동 분석 및 평가)

  • Cho, Sung-Won;Lee, Jung-Hwan;Kim, Hyo-Jung;Choi, Byeong-Keun
    • Proceedings of the KSME Conference
    • /
    • 2007.05a
    • /
    • pp.1020-1025
    • /
    • 2007
  • The reciprocating type hydrogen compressor is for high pressure and volume. However this type compressor makes pulsation caused by mechanical characteristic. This type compressor also makes noise and vibration that cause negative effect to machine and working condition. Therefore, diagnosis and countermeasure are needed to decrease vibration for safety on hydrogen compressor. therefore in this paper, the numerical analysis and vibration measurement is conducted in order to investigate vibration characteristic and to evaluation vibration condition, Respectively

  • PDF

The CFD Analysis Comparison of Several Snubbers with different Buffer Width (버퍼의 넓이가 다른 스너버의 수치해석 비교)

  • Lee, G.H.;Shim, K.J.;Lee, Y.H.;Chung, H.S.;Jeong, H.M.
    • Journal of Power System Engineering
    • /
    • v.11 no.4
    • /
    • pp.38-43
    • /
    • 2007
  • Pulsation is an inherent phenomenon in reciprocating compressors. It interacts with piping to cause vibrations and performance problems. Indiscriminately connecting to a compressor can be dangerous and cost money in the form of broken equipment and piping, poor performance, inaccurate metering, unwanted vibration, and sometimes noise. Piping connected to a compressor can materially affect the performance and response. To minimize these detrimental effects, reciprocating compressor system should be equipped by pulsation suppression system. The system usually comprises bottle volume, called snubber. Snubber is one of the most important parts in hydrogen compressing system. It has installed reciprocating hydrogen compressor. One of these components is snubber which has function to reduce pulsation waveform and to remove the impurities in the hydrogen gas. A snubber has an inclined plate as a buffer, which is installed inside snubber. When the pressure loss and the pulsation of pressure within a snubber is minimized, the snubber could get more applicability. Therefore, a study to find an optimum geometric size on a several snubbers which have different buffer width, has been conducted using a numerical analysis.

  • PDF

Thermal Performance Analysis of Reciprocating Compressors for Refrigerator-freezers (냉장고용 왕복동 압축기의 성능 해석)

  • KIM, MAN-HOE
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.27 no.2
    • /
    • pp.236-243
    • /
    • 2016
  • This paper presents a simple thermo-physical model of reciprocating compressors for household refrigerator-freezers. The compressor model has been developed based on thermodynamic principles and large data sets from the compressor calorimeter tests. The input data are compressor geometry (displacement and clearance volume), compressor speed, suction pressure and temperature, discharge pressure, and ambient temperature. The model can estimate mass flow rate and compressor power consumption within 3.0% accuracy, which is not much larger than measurement errors associated with calorimeter testing under ideal conditions.

Numerical Analysis on the $2^{nd}$ Discharae-passase In Reciprocating Compressor (왕복동식 수소압축기의 2단 토출통로 유동해석)

  • Lee, G.H.;Rahman, M. Sq.;Kim, C.P.;Joung, T.W.;Jeong, H.M.;Chung, H.S.
    • Journal of Power System Engineering
    • /
    • v.13 no.3
    • /
    • pp.27-32
    • /
    • 2009
  • Numerical analysis information of a complex discharge-passage will be very useful to improve hydrogen compression system. General information about an internal gas flow is presented by numerical analysis approach. Relating with hydrogen compressing system, which have an important role in hydrogen energy utilization, this should be a useful tool to observe the flow quickly and clearly. Flow characteristic analysis, including pressure and turbulence kinetic energy distribution of hydrogen gas from cylinder going to the chamber of a reciprocating compressor are presented in this paper. Discharge-passage model is designed based on real model of hydrogen compressor. Pressure boundary conditions are applied considering the real condition of operating system. The result shows pressure and turbulence kinetic energy are not distributed uniformly along the passage of the hydrogen compressing system. Path line or particles tracks help to demonstrate flow characteristics inside the passage. The existence of vortices and flow direction can be precisely predicted. Based on this result, the design improvement should be done. Consequently, development of the better hydrogen compressing system will be achieved.

  • PDF

The Vibration Characteristic of Optimizing Snubber of Reciprocating Type Hydrogen Compressor for Pressure Loss Reduction (압력 손실을 줄이기 위해 최적화된 왕복동식 수소 압축기용 완충기의 진동 특성 분석)

  • Kim, W.C.;Kim, H.J.;Jeong, J.H.;Jang, Y.S.;Choi, B.K.
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1116-1122
    • /
    • 2008
  • The reciprocating type hydrogen compressor has a pulsation due to the reciprocative characteristics which results in noise and vibration. Snubber is installed for the relaxation of pulsation, but it causes reduction of compressor efficiency because of pressure loss. Five types of snubber were modeled for the numerical investigation of the effect of the relative position of inlet and outlet and buffer angle on the pulsation amplitude and pressure loss. MSC/NASTRAN is used as a numerical tool to identify the vibration characteristic of each type. Frequency responses in forced vibration mode are compared for various cases and buffer angles.

Numerical Analysis on the Working Fluid Flow of Suction-passage for Reciprocating Compressor (왕복동식 수소압축기의 흡입통로내 작동유체 유동해석)

  • Lee, Gyeong-Hwan;Rahman, Mohammad Shiddiqur;Shim, Kyu-Jin;Jeong, Hyo-Min;Chung, Han-Shik
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.32 no.8
    • /
    • pp.1201-1207
    • /
    • 2008
  • Numerical analysis information will be very useful to improve fluid system. General information about an internal gas flow is presented by numerical analysis approach. Relating with hydrogen compressing system, which have an important role in hydrogen energy utilization, this should be a useful tool to observe the flow quickly and clearly. Flow characteristic analysis, including pressure and turbulence kinetic energy distribution of hydrogen gas coming to the cylinder of a reciprocating compressor are presented in this paper. Suction-passage model is designed based on real model of hydrogen compressor. Pressure boundary conditions are applied considering the real condition of operating system. The result shows pressure and turbulence kinetic energy are not distributed uniformly along the passage of the Hydrogen system. Path line or particles tracks help to demonstrate flow characteristics inside the passage. The existence of vortices and flow direction can be precisely predicted. Based on this result, the design improvement, such as reducing the varying flow parameters and flow reorientation should be done. Consequently, development of the better hydrogen compressing system will be achieved.

Effect of Snubber-Array on Variation of Pressure Characteristics in Reciprocating Hydrogen Compression

  • Chung, Han-Shik;Rahman, M. Sq.;Lee, Gyeong-Hwan;Jin, Zhenhua;Kim, Jeong-Hyeon;Jeong, Hyo-Min
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.33 no.7
    • /
    • pp.1034-1043
    • /
    • 2009
  • Hydrogen energy is becoming popular day by day due to its renewability and pollutaaant free natures. Hydrogen gas pressure which is after passing through reciprocating compressor part has high pulsation wave form. A unit, snubber is used as compressor components to reduce the harmful pulsation waveform and to remove the impurities in the hydrogen gas. An experiment has been conducted to investigate the pulsation reduction performance of different arrangement of snubber i.e. snubber array used in reciprocating compression system. Analyzing the snubber array experimental data, it is found that the pressure fluctuations are reduced from 90.1977% ~ 92.6336% with pressure loss 1.5013% ~ 4.9034% for compressor operation at different speed which ensure the good performance of snubber-array as pulsation damper in hydrogen compressing system.

The Vibration Analysis of Snubber for Reciprocating Type Hydrogen Compressor (왕복동식 수소 압축기용 완충기 진동 특성 분석)

  • Kim, H.J.;Jang, Y.S.;Cho, S.W.;Choi, B.K.
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2007.11a
    • /
    • pp.53-56
    • /
    • 2007
  • The reciprocating type hydrogen compressor is occurred by the pulsation from the mechanism and this pulsation is make much noise and vibration. Therefor snubber is installed for pulsation decreasing. The five type snubber models were designed for increasing pulsation amplitude reduction and decreasing pressure loss in snubber considering output pipe location as design value. And the pressure flued analysis is carried by CFD. In this paper, each type snubber according CFD result are analyzed by the MSC/NASTRAN to identify the vibration characteristic of each type. The vibration results are compared with CFD results.

  • PDF

CFD and Experimental Study of Gas Flow Inside the Steel Pipe Fitted in Reciprocating Hydrogen Compression System (왕복동식 압축시스템에 연결된 파이프 내부의 유동특성에 관한 CFD와 실험)

  • Rahman, Mohammad-Shiddiqur;Lee, Gyeong-Hwan;Lee, Kwang-Sung;Chung, Han-Shik;Jeong, Hyo-Min
    • Proceedings of the SAREK Conference
    • /
    • 2009.06a
    • /
    • pp.1513-1520
    • /
    • 2009
  • Renewability and pollutant free energy source makes hydrogen energy popular rapidly. Hydrogen gas pressure which is after passing through reciprocating compressor part has high pulsation wave form. A unit, snubber is used as compressor components to reduce the harmful pulsation waveform and to remove the impurities in the hydrogen gas. An experiment has been conducted to investigate the pulsation reduction performance of a steel pipe used in snubber system. The amplitude of pressure reduction were varied from $0.054{\sim}0.321\;kPa$ for 10 hz to 60 hz motor speed. Compressor operation by motor with 10 to 60 hz were resulted in reduction of pressure pulsation from 16.415% to 35.151%. Pressure losses were varied from $0.001%{\sim}0.759%$, and pressure drop per centimeter of the steel pipe were varied from $0.0160{\sim}16.03\;Pa$.

  • PDF