Effect and Control of the Sediment in the Combined Sewer on CSOs (합류식 하수관거내 퇴적물이 CSOs에 미치는 영향 및 제어방안)

  • Lim, Bongsu;Kim, Doyoung;Lee, Kuangchun
    • Journal of Korean Society on Water Environment
    • /
    • v.27 no.1
    • /
    • pp.36-43
    • /
    • 2011
  • This study is selected two points of combined sewer that occurred Fish Kill after first flush, that analyzed generation of pollutants and stream runoff generation of combined sewer overflows (CSOs) as fine weather and rainfall. In addition, this study was to analyze the relationship between CSOs and sediments, to propose measures to reduce the sediment relevant with CSOs and rainfall runoff from entering sewage treatment plants and measures for discharged directly into streams when indicate relatively good water quality after overflow. Sediments in combined sewer system was discharged about 50~80% as overflows during rainfall and we can reduce the amount of the CSOs at least 50% or more if the sewer does not exist in the sediments because of the amount of discharge about the amount of intercept has been investigated by 3~5 times. Because of velocity at sediment interval in sewer is very low, sewage velocity of about 3~5 times as much as it can increase the amount of sediment can be reduced if the separation wall is installed. Effective control of BOD overflow load is respectively 77.5%, 75.8% at first point, second point by the separation wall is installed. Drainage area greater than area in this study or many combined sewer overflows region is increased the more effective control of separation wall. Turbidity to measure changes in water quality of overflows can be used as an factor to control the intercept flows because the intercept flows(3Q) after the first flush has lowered removal efficiency and increases the operational load of sewage treatment plants. Sewage water quality after a overflow when the reasonable turbidity was measured at this point flows to excluded intercept flow(1Q) can be discharged to stream.

Applicability Test of STPS for HEC-RAS-based Turbidity Prediction Model in the Nagdonggang (HEC-RAS에 기반한 탁도예측모형 STPS의 낙동강에 대한 적용성 검토)

  • Lee, Namjoo;Choi, Seohye;Kim, Chang-Sung
    • Ecology and Resilient Infrastructure
    • /
    • v.8 no.4
    • /
    • pp.245-252
    • /
    • 2021
  • A turbidity current in a river and a lake occurs due to diverse nutrient loading including suspended sediment in sediment runoff, which affects water withdrawal and river environments. We developed one dimensional time-variant numerical model based on Python for the Nagdonggang mainstream. We examined the numerical stability and the applicability of the model by performing the simulation of quasi-steady flow in non-flooding for three cases, which are different according to the point and the amount of turbidity inflows in the Nagdonggang upstream and a tributary. The result was reasonable in the respect of the conservation of matter. The model will facilitate to simulate a large river if we can secure the data of turbidity variations in a target river reach or measured points in a field.

A Study on the Turbidity Estimation Model Using Data Mining Techniques in the Water Supply System (데이터마이닝 기법을 이용한 상수도 시스템 내의 탁도 예측모형 개발에 관한 연구)

  • Park, No-Suk;Kim, Soonho;Lee, Young Joo;Yoon, Sukmin
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.2
    • /
    • pp.87-95
    • /
    • 2016
  • Turbidity is a key indicator to the user that the 'Discolored Water' phenomenon known to be caused by corrosion of the pipeline in the water supply system. 'Discolored Water' is defined as a state with a turbidity of the degree to which the user visually be able to recognize water. Therefore, this study used data mining techniques in order to estimate turbidity changes in water supply system. Decision tree analysis was applied in data mining techniques to develop estimation models for turbidity changes in the water supply system. The pH and residual chlorine dataset was used as variables of the turbidity estimation model. As a result, the case of applying both variables(pH and residual chlorine) were shown more reasonable estimation results than models only using each variable. However, the estimation model developed in this study were shown to have underestimated predictions for the peak observed values. To overcome this disadvantage, a high-pass filter method was introduced as a pretreatment of estimation model. Modified model using high-pass filter method showed more exactly predictions for the peak observed values as well as improved prediction performance than the conventional model.

Study on Salinity Distribution Change by the Fresh Water at the Bay in Flood (홍수기 하구로 유입된 담수로 인한 만에서의 염분분포 변화에 관한 연구)

  • Lee, Hyun-Seok;Ishikawa, Tadaharu;Kim, Young-Sung;Chae, Hyo-Sok
    • Journal of Korea Water Resources Association
    • /
    • v.44 no.1
    • /
    • pp.23-30
    • /
    • 2011
  • Any significant inflow of fresh water due to flood or snow melting can rapidly reduce salinity at the bay. In such a case, the habitat environment in the sea near river mouth can be partly destroyed. Therefore, research to understand the salinity distribution quantitatively at the bay for the utilization of natural environment and for the inhabitant conservation must be very important. In this study, the investigation on the relationship between satellite image and turbidity is carried out first, and then the salinity distribution at the bay using the relationship between turbidity and salinity is derived. The main results are as follows. First the reappearance ability of RGB bands respectively of the satellite image is investigated, and then it was confirmed that the combination of band2 and band3 expressed best the movement characteristics of turbid water at the bay is chopped up into 4 small areas. Second the turbidity of river mouth is estimated using the travel time from the upward monitoring station to the river mouth. Finally the satellite image is converted into the salinity distribution by the correlation of salinity and turbidity. It is confirmed that the salinity distributions obtained from above three investigation methods are quite reasonable and clear.

Verification of Silt Density Index (SDI) as a fouling index for reverse osmosis (RO) feed water (역삼투 공정 파울링 지표로서 SDI(Silt Density Index)의 적합성 검증)

  • Kim, Su-Han;Kim, Chung-H.;Kang, Suk-H.;Lee, Won-T.;Lim, Jae-L.
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.4
    • /
    • pp.489-495
    • /
    • 2011
  • Silt Density Index (SDI) has been used as a fouling index for reverse osmosis (RO) processes for decades. In order to decrease RO fouling, feed water should meet SDI standard, which was used to select a proper pretreatment system for RO processes. However, SDI is supposed to be sensitive only to particles larger than 0.45 ${\mu}m$ in terms of diameters while nanoparticles and dissolved organic matter can be potent foulants for RO processes. Our study started from the suspected performance of SDI as a RO fouling index. SDI data from pilot plants located world wide including South Korea were collected and analyzed. Suspended partcle concentration (i.e., turbidity and particle counts), and dissolved organic matter concentration (i.e., dissolved orgnaic carbon (DOC) concentration) data were also collected and compared to SDI values of same water samples. We found that SDI values were not only affected by suspended particle concentration but also by dissolved organic matter concentration. Therefore SDI can be used as a reasonable fouling index for RO feed water because the main foulants for RO processes are suspended particle and dissolved organic matter.

Influence of Different Mixing Types on the Removal of Natural Organic Matter in Water Treatment (정수처리시 천연유기물질의 제거에 대한 급속혼화유형의 영향)

  • Kim, Hyun-Chul;Yu, Myong-Jin;Lee, Seock-Heon
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.19 no.3
    • /
    • pp.370-377
    • /
    • 2005
  • Dispersion of coagulant should be completed in a fraction of a second before the metal hydroxide precipitate has form. For the reason so-called pump diffusion flash mixing (PDFM) have been proposed, and PDFM is one of reasonable methods to quickly disperse the hydrolyzing metal salts. In this study, therefore, we attempt to understand the difference of removal characteristics of natural organic matter (NOM) between pump diffusion flash mixing (PDFM) and conventional rapid mixing (CRM) for coagulation in a water treatment system, and to enhance the removal of NOM through the improved mixing process. DOC and turbidity removal by PDFM higher than those by CRM, while SUVA value of water treated by PDFM was high as compared with that by CRM. Hydrophilic NOM was more effectively removed by PDFM than CRM, since charge neutralization effect increased by quick dispersion of coagulant. The DBP formation potentials due to NOM was effectively reduced by the improved mixing (i.e., PDFM) for coagulation and could be controlled through decrease in concentration of precursor rather than reduction of activity with disinfectant.

Effects of flushing techniques on water quality at extremity with low chlorine residuals in drinking water distribution systems (수질 취약지역 및 관말에서 플러싱 적용 먹는물 수질 개선 효과)

  • Ko, Kyung-Hoon;Kweon, Ji-Hyang;Kim, In-Ja;Lim, Woo-Hyuk
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.25 no.3
    • /
    • pp.313-324
    • /
    • 2011
  • Several complaints from consumers on red or turbid waters were often filed at the same places although various efforts were made to improve water quality in the drinking water plant. The red water problems were occurred due to corrosion of main water pipe, especially at extremity. The low concentrations of chlorine indicating poor water quality were detected at the problematic location. To solve the poor water quality at the extremity, flushing techniques, i.e., conventional flushing, unidirectional flushing, and continuous flushing, were recently practiced. In this study, effects of conventional flushing on water qualities were examined by comparing turbidity and residual chlorine before and after flushing. In addition, more detailed analyses on water qualities at the tap water were conducted to learn a reduction pattern during flushing. Five items from geographic information system of water distribution were used to obtain a relationship with water quality, washing duration or amounts of washing water. The flushing was effective to meet the National Drinking Water Quality Standard with simple and relatively short time operation. The key operational parameter in flushing was amounts of washing water which should be estimated based on water quality of the consumer's tap water. The positive relationship between the residual chlorine and pipe length implied that detention time in the pipeline was the main cause of the complaints. More experiments on effectiveness of flushing are needed to determine reasonable strategies of flushing.

Evaluation of Coagulation Characteristics of Fe(III) and Al(III) Coagulant using On-line Monitoring Technique (On-line 모니터링 기법을 이용한 Al염계와 Fe염계 응집제의 응집특성 평가)

  • Son, Hee-Jong;Yoom, Hoon-Sik;Kim, Sang-Goo;Seo, Chang-Dong;Hwang, Young-Do
    • Journal of Environmental Science International
    • /
    • v.23 no.4
    • /
    • pp.715-722
    • /
    • 2014
  • Effects of coagulation types on flocculation were investigated by using a photometric dispersion analyzer (PDA) as an on-line monitoring technique in this study. Nakdong River water were used and alum and ferric chloride were used as coagulants. The aim of this study is to compare the coagulation characteristics of alum and ferric chloride by a photometric dispersion analyzer (PDA). Floc growing rates ($R_v$) in three different water temperatures ($4^{\circ}C$, $16^{\circ}C$ and $30^{\circ}C$) and coagulants doses (0.15 mM, 0.20 mM and 0.25 mM as Al, Fe) were measured. The floc growing rate ($R_v$) by alum was 1.8~2.8 times higher than that of ferric chloride during rapid mixing period, however, for 0.15 mM~0.25 mM coagulant doses the floc growing rate ($R_v$) by ferric chloride was 1.1~2.3 times higher than that of alum in the slow mixing period at $16^{\circ}C$ water temperature. Reasonable coagulant doses of alum and ferric chloride for turbidity removal were 0.1 mM (as Al) and 0.2 mM (as Fe), respectively, and the removal efficiency of those coagulant doses showed 94% for alum and 97% for ferric chloride. The appropriate coagulant dose of alum and ferric chloride for removing dissolved organic carbon (DOC) showed about 0.3 mM (as Al, Fe) and at this dosage, DOC removal efficiencies were 36% and 44%, and ferric chloride was superior to the alum for removal of the DOC in water.

Design and Operation of the Rainwater-Greywater Hybrid System : SNU No. 39 Building (빗물-저농도 오수 하이브리드 시스템의 설계 및 운전 평가 : 서울대 39동)

  • Shim, In-tae;Park, Hyun-ju;Kim, Tschung-il;Jung, Sung-un;Han, Moo-young;Namkung, Eun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.38 no.12
    • /
    • pp.676-682
    • /
    • 2016
  • In this study, rainwater-greywater hybrid system was installed and operated for 1 year in order to evaluate its water quantity, water quality, and economic efficiency in building no. 39. This system was expected to overcome each disadvantages of and maximize each advantages. Low-greywater that was washed up from shower room was treated by MBR (Membrane Bioreactor) and ozone oxidation. Rainwater that was collected from the rooftop was stored in a reservoir, and then transferred to the storage tank that was mixed with treated greywater. After 1 year operating in building no. 39, rainwater and greywater was used to supply $2,599m^3$ of toilet flushing water. In terms of water quality, rainwater was satisfied far the greywater reuse standards except for E.coli. Moreover, low greywater quality was acceptable except for E. coli, BOD, SS, and turbidity. In addition, economic analysis was obtained from benefit-cost ratio (B/C) with 1.11. It implies that the feasibility of the project was reasonable. Furthermore, various research and policy to improve the economic efficiency of water recycling facilities is required to expand the use of water recycling facilities.