• Title/Summary/Keyword: Rearguider

Search Result 11, Processing Time 0.028 seconds

Experimental Study on the Performance of a Cross-Flow Fan with Various Diameter Ratios of Impeller and Rearguider Shapes (임펠러 직경비 및 리어가이더 형상변화가 횡류홴 성능에 미치는 실험적 연구)

  • Kim, H.S.;Kim, D.W.;Yoon, T.S.;Park, S.K.;Kim, Youn-J.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2003.12a
    • /
    • pp.391-396
    • /
    • 2003
  • A cross-flow fan relatively produces higher dynamic pressure at low speed because a working fluid passes through an impeller blade twice and blades have a forward curved shape. The performance of a cross-flow fan is influenced 25% by the impeller, 60% by the rearguider and the stabilizer, and 15% by the heat exchanger. At the low flow rate, there exist a rapid pressure head reduction, a noise increase and an unsteady flow against a stabilizer and a rearguider. The purpose of this study is to investigate the reciprocal relation among each parameter Experiments are conducted to study the effects of a rearguider and a diameter ratio of impeller on the performance analysis of a cross-flow fan. Comparing with the rearguider of radial type, the Archimedes type shows excellent results for various diameter ratios.

  • PDF

Effects of Starting Angles of a Rearguider on the Performance of a Cross-Flow Fan (리어가이더 시작각 변화가 횡류홴 성능에 미치는 영향)

  • Kim, Hyung-Sub;Kim, Dong-Won;Yoon, Tae-Seok;Park, Sung-Kwan;Kim, Yun-Je
    • Proceedings of the KSME Conference
    • /
    • 2004.04a
    • /
    • pp.1981-1986
    • /
    • 2004
  • A cross-flow fan relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice and blades have a forward curved shape. Therefore, the performance of a cross-flow fan is influenced 25% by the impeller, 60% by the rearguider and the stabilizer, 15% by the heat exchanger. At the low flow rate, there exists a rapid pressure head reduction, a noise increase and an unsteady flow against a stabilizer and a rearguider. Moreover, it is difficult to analyze the reciprocal relations of the cross-flow fan because each parameter is independent. Numerical analyses are conducted with different starting angles of the rearguider. Two-dimensional, unsteady governing equations are solved, using FVM, PISO algorithm, sliding grid system and ${\kappa}-{\varepsilon}$ standard turbulence model.

  • PDF

Performance Characteristics of a Cross-Flow Fan with Various Impeller Outlet Angles and Rearguiders (임펠러 출구각 및 리어가이더 형상 변화에 따른 횡류홴의 성능 특성)

  • Kim, H.S.;Kim, D.W.;Yoon, T.S.;Park, S.K.;Kim, Youn-J.
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.851-856
    • /
    • 2003
  • A cross-flow fan consists of an impeller, a stabilizer and a rearguider. When it applied for an air conditioner, an evaporator should be added. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice and blades have a forward curved shape. Therefore, the performance of a cross-flow fan is influenced 25% by the impeller, 60% by the rearguider and the stabilizer, 15% by the heat exchanger. At the low flow rate, there are a rapid pressure head reduction, a noise increase and an unsteady flow against a stabilizer and a rearguider. Moreover, the reciprocal relation between the impeller and the flow passage is the important factor for performance improvement of the cross-flow tan because each parameter is independent. The performance characteristics in the cross-flow fan are graphically depicted with various impeller outlet angles and rearguiders.

  • PDF

Performance Estimation of Cross-Flow Fan by Numerical Method (수치해석적 기법을 이용한 횡류홴 성능 평가)

  • Kim, D.-W.;Lee, J.-H.;Park, S.-K.;Kim, Youn-J.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.152-157
    • /
    • 2002
  • A cross-flow fan is widely used on many industrial fields: a blower for the general industry, mining industry, automobile and home appliances. The design point of the cross-flow fan is generally chosen by based on the region within low static pressure and high flow rate. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice. However, it has low static pressure efficiency between $30\%$ and $40\%$ because of relative high impact loss. Recently, in the air-conditioning systems, the operating behaviors at the off-design points are highly regarded to broaden the application area for various air-cooling loads. Especially, at the low flow rate, there exists a rapid pressure head reduction, a noise increase and an irregular flow against a rearguider as a scroll of centrifugal fan. Numerical analyses are carried out for cross-flow fan including the impeller, the rearguider and the stabilizer. Numerical domains are discretized by hexahedral cells. Three-dimensional, unsteady governing equations are solved using FVM, SIMPLE algorithm, sliding grid system and standard k-$\epsilon$ turbulence model.

  • PDF

Analysis of Performance of Cross-Flow Fan with Various Rear Guiders (리어가이더 형상변화에 따른 횡류홴 성능해석)

  • Kim, Dong-Won;Lee, Jun-Hwan;Park, Seong-Gwan;Kim, Yun-Je
    • Proceedings of the KSME Conference
    • /
    • 2003.04a
    • /
    • pp.2076-2082
    • /
    • 2003
  • A cross-flow fan is widely used on many industrial fields: mining industry, automobile and home appliances, etc. The design point of the cross-flow fan is generally based on the region within low static pressure and high flow rate. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice. However, it has low static pressure efficiency between 30% and 40% because of relative high impact loss. Recently, in the air-conditioning systems, the operating behaviors at the off-design points are highly regarded to broaden the application area for various air-cooling loads. Especially, at the lower flow rate, there exists a rapid pressure head reduction, a noise increase and an irregular flow field against a rearguider as a scroll of centrifugal fan. Numerical analyses are carried out for investigating the flow characteristics in a cross-flow fan including the impeller, the rearguider and the stabilizer. Especially, various types of rearguiders are estimated by numerical and experimental methods to insure the stable operation in the region of lower flow rate. Numerical domains are discretized by hexahedral cells. Three-dimensional, unsteady governing equations are solved using FVM, PISO algorithm, sliding grid system and standard ${\kappa}-{\varepsilon}$ turbulence model. ASHRAE standard fan tester is also used to estimate the performance of the modeled crossflow fan.

  • PDF

Performance of a Cross-Flow Fan with Various Stabilizer Positions and Rearguider Shapes (스태빌라이져 위치 및 리어가이더 형상변화에 따른 횡류홴의 성능특성 연구)

  • Kim, D.W.;Kim, H.S.;Yoon, T.S.;Park, S.K.;Kim, Yon J.
    • The KSFM Journal of Fluid Machinery
    • /
    • v.7 no.4 s.25
    • /
    • pp.7-15
    • /
    • 2004
  • The design point of the cross-flow fan is generally based on the region within low static pressure and high flow rate. It relatively makes high dynamic pressure at low speed because a working fluid passes through an impeller blade twice. However, it has low static pressure efficiency between $30\%$ and $40\%$ because of relative high impact loss. The purpose of this study is to research the reciprocal relation among each parameter. Experiments and numerical analyses are conducted on effects of a stabilizer and a rearguider on performance analysis of a cross-flow fan. Two-dimensional, unsteady governing equations are solved using FVM, PISO algorithm, sliding grid system and standard $k-{\epsilon}$ turbulence model. Experiments are also carried out to estimate the performance of the modeled cross-flow fan. It is clarified that the rearguider of Archimedes type has excellent results for the most part.

Transient Flow Characteristics of the Room Air Conditioner (룸에어컨 내부 유동의 과도현상에 대한 수치적 연구)

  • Seo, Hyeon-Seok;Kim, Jin-Baek;Kim, Youn-Jea
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.526-529
    • /
    • 2008
  • Air Conditioner has become a popular comfort providing device since two decades, whether in an office or home especially for warm and wet climate countries. The RAC (Room Air Conditioner) is widely used in various working spaces and residences. It composed of heat exchager, cross-flow fan, stabilizer, rearguider and blade of diffuser region, etc. In this study, numerical analyses based on the prediction of transient phenomena were carried out to investigate the flow characteristics in the RAC, including the impeller, the rearguider, the stabilizer and the blade of the diffuser region. Using a commercial code, FLUENT, the velocity, pressure and streamlines were obtained with unsteady, turbulent flow and no-slip condition. The angular velocities of impeller are located in the 900 rpm. Turbulent closure was achieved using a standard k-${\varepsilon}$ model. A moving reference frame (MRF) approach was adopted to simulate the flow field generated by impeller in the RAC. Results were graphically depicted with various geometrical configurations and operating conditions.

  • PDF

A Study on the Operational Characteristic with the Scale Effect of the Cross-Flow Fan (치수효과를 고려한 횡류홴의 작동특성연구)

  • Kim, H.-S.;Kim, Youn-J.
    • 유체기계공업학회:학술대회논문집
    • /
    • 2004.12a
    • /
    • pp.583-589
    • /
    • 2004
  • One of noticeable features in the cross flow fan is that a working fluid passes through impeller blade twice without distinction between the inlet and exit angles. Also, it does produce higher circumferential velocity than other types of blade at the same flow rate in accordance with the application of the forward curved shape. However, a design theory for the cross-flow fan has not yet been formed owing to an eccentric vortex, which is the remarkable characteristics, occurred in a cross-flow fan. Furthermore, the eccentric vortex, which is difficult to control of the size and position, is the important cause of performance decrease. In this study, experiments are carried out to estimate the similarity of the cross-flow fan with various scales and rotational velocity changes. Pressure coefficients to flow coefficients with various scales of the cross-flow fan are plotted to research the application of the general similarity law of the turbomachinery in the cross-flow fan with Archimedes spital, which is the important factor haying an effect on it.

  • PDF