• Title/Summary/Keyword: Rear door

Search Result 23, Processing Time 0.025 seconds

Structural Safety Analysis of Openable Working Table in ACP Hot Cell for Spent Fuel Treatment (사용후핵연료 처리를 위한 ACP 실증시설내 개폐형 작업대의 구조적 안전성 평가)

  • Kwon, Kie-Chan;Ku, Jeong-Hoe;Lee, Eun-Pyo;Choung, Won-Myung;You, Gil-Sung;Lee, Won-Kyung;Cho, Il-Je;Kuk, Dong-Hak
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.4 no.1
    • /
    • pp.17-24
    • /
    • 2006
  • A demonstration facility for advanced spent fuel conditioning process (ACP) is under construction in KAERI. In this hot cell facility, all process equipments and materials are taken in and out only through the rear door. The working table in front of the process rear door is specially designed to be openable for the efficient use of the space. This paper presents the structural safety analysis of the openable working table, for the normal operational load condition and accidential drop condition of heavy object. Both cases are investigated through static and dynamic finite element analyses. The analysis results show that structural safety of the working table is sufficiently assured and the working table is not collapsed even when an object of 500 kg is dropped from the height of 50 cm.

  • PDF

Study on Rear Door Fixed Glass Weather-strip for Automobiles Using EPDM/Polypropylene Blend (I) (자동차용 Rear Door Fixed Glass Weather-strip 성형을 위한 EPDM과 Polypropylene의 Blend에 관한 연구 (I))

  • Park, Jong-Yun;Hwang, Sung-Hyuk;Kim, Jin-Kuk
    • Elastomers and Composites
    • /
    • v.35 no.2
    • /
    • pp.115-121
    • /
    • 2000
  • In comparison with thermosetting rubber, thermoplastic elastomer (TPE) has various advantages such as simple processing, short cycle time and recycling of scrap. These advantages can lead to development of the high value-added rubber products due to reduction of the waste material, manufacturing cost and the defected product. This article involves a dynamic vulcanization method for EPDM/polypropylene blend, and the manufacturing of a fixed glass weather-strip by glass insert molding method using the blend. In order to investigate mechanical properties of the product, tensile strength, elongation, hardness and specific gravity were measured. Also morphological study was carried out using SEM. Developments of an efficient system of production and automatic process by molding of TPE and glass simultaneously are expected.

  • PDF

Effect of Automobile Exterior Panel Stiffness on Customers' Affect : Focused on Hood and Door of Mid-Size Passenger Cars (자동차 외판 강성의 고객 감성 영향 분석 : 승용차의 후드 및 도어를 중심으로)

  • Ryu, Taebeum;Kim, Wonjun;Jin, Byungki;Yun, Myung Hwan
    • Journal of Korean Institute of Industrial Engineers
    • /
    • v.42 no.5
    • /
    • pp.360-369
    • /
    • 2016
  • This study attempted to identify the effect of the panel stiffness on the customers' affect, which was not addressed in the research field of affective engineering. For this, this study derived four affects related to the panel stiffness from literature and pre-experiment : hardness, deform consistency, thickness and satisfaction and prepared a questionnaire to evaluate the affects of the panel. In the experiment, 54 adults in the age of 20~50 participated and evaluated the affects of hood, front and rear door for nine full size and luxury sedans by pressing the panels with their hands. As results, participants' affect for the panels were significantly different depending on the force-deflection curves of them, and the subjects' satisfaction of the panels increased as the slope of the curve (stiffness) increases. In addition, it was found that the subjects evaluated the panel with the pressing force up to 14kgf. The findings of the study can be used to increase and control the affective quality of exterior panels on passenger cars.

A Study on Manufacture of Phosphor Screen for Video Phone Tube (Video Phone Tube用 형광박의 제조에 관한 연구)

  • Woo, Jin-Ho
    • Journal of the Korean Graphic Arts Communication Society
    • /
    • v.22 no.2
    • /
    • pp.123-138
    • /
    • 2004
  • The video phone tube (VPT) of monochrome CRT have utilized home door phone, fish-finder and the rear watch monitors. Phosphor screen formation is made by electrodeposition spin coating and thermal transfer methods etc. Recently, thermal transfer method was developed, as a novel method, to form the phosphor surface for mnonchrom VPT. This method have advantages of simple process, automatization, clean environment, saving raw material and saving running-cost. In this study, it was developed new phosphor of VPT, and tested about phosphor paste properties. An experimental studies of VPT as a new phosphor property and improved VPT's manufacturing process shortening and brightness. As thermal transper method is a paste processing, it is important that rheology of phosphor effects on the formation of phosphor screen. Hence this paper was studied rheology properties of phosphor paste and the formation of phosphor screen had looked most suitable condition. Experimented thermal separation properties of low calcination temperature resin and the result analyzed comparison by TGA. Also, examined calcination properties to reduce remaining binder phosphor.

  • PDF

RADIATION MONITORING SYSTEM FOR ADVANCED SPENT FUEL CONDITIONING PROCESS FACITLITY

  • Kook Dong-Hak;Choung Won-Myung;Lee Eun-Pyo;You Gil-Sung;Cho Il-Je;Kwon Kie-Chan;Lee Won-Kyoung;Ku Jeoung-Hoe
    • Proceedings of the Korean Radioactive Waste Society Conference
    • /
    • 2005.11b
    • /
    • pp.149-155
    • /
    • 2005
  • The $ACP^1$ is under development for effective management of spent fuel by converting $UO_2$ into U-metal. For demonstration of this process, $\alpha-\gamma$ type new hotcell was built in the $IMEF^2$ basement. To secure against radiation hazard, this facility needs radiation monitoring system which will observe the entire operating area before the hotcell and service area at back of it. This system consists of 7 parts; Area Monitor for $\gamma$-ray, Room Air Monitor for particulate and iodine in both area, Hotcell Monitor for hotcell inside high radiation and rear door interlock, Duct Monitor for particulate of outlet ventilation, Iodine Monitor for iodine of outlet duct, CCTV for watching workers and material movement, Server for management of whole monitoring system. After installation and test of this, radiation monitoring system will be expected to assist the successful ACP demonstration.

  • PDF

The Organization of Domestic Space in Belgium - With Special Reference to Flemish Area - (벨지움 주택의 평면구성에 대한 연구)

  • 김미희
    • Journal of the Korean housing association
    • /
    • v.7 no.1
    • /
    • pp.15-24
    • /
    • 1996
  • This study attempts to explore the organization of domestic space in Belgium and then to compare them with those found in Korea. Data were collected by questionnaires mailed to 110 staff members, both academic an dadministrative, working at Vrije Universiteit Brussel in Belgium.The major findings of the study can be summarized as fllows: First, the most common pattern of Belgian LDK(living-room dining-room and kichen) layout is the LD type, which separates K from L and D by wall or door while linking L and D to each other. On the other hand, a large portions of Korean LDK layout is the DK type , which seperates L from D and H, but D and K are interconnected. As expected, the bigger the size of floor space, the more likely L-D-K type is to be, which places L, D, and f, separate each other. And the smaller the sire the more probable the DK type and/or the one room type would be, where L, D and K are merged into one room. Second, the enterance of domestic space in Belgium is normally found adjacent to public space. The Belgian entrance often forms a space independent from other parts of the house, or a space that leads directly to garage. These two patterns are rarely found in Korea. Third, Belgians tend to locate Kichen in the front of the house when they design apartment units, Whereas it is not the case in Korea where it is located in the rear.

  • PDF

Measurement from Moving Vehicle Health Screening Outside of The Leakage Dose (이동건강검진차량에서 외부의 누설선량 측정)

  • Han, Beom-Hee;Han, Sang-Hyun;Mo, Eun-Hee;Kim, Chong-Yeal
    • The Journal of the Korea Contents Association
    • /
    • v.15 no.3
    • /
    • pp.192-198
    • /
    • 2015
  • Checked out by the moving vehicle health checks for patients, practitioners, and the increase in radiation dose outside the vehicle, but an investigation into the leakage of radiation can still be negligible. In this study, through experimental results were as follows: Dose that occurs most often where the leak in the right door $1.14{\pm}1.75mR/h$, X-ray generator in terms of proximity to the top $0.65{\pm}1.25mR/h$, X-ray generator and away to the bottom in terms $0.91{\pm}1.25mR/h$, the adjacent rear detector in the upper part $96.98{\pm}158.88mR/h$ dose of the leak appeared in various locations. By measuring position from the rear of the adjacent detector $67.48{\pm}97.03mR/h$ dose had the highest leakage into. Generating device for diagnosis of radiation safety regulations regarding the maximum leakage dose per week, but all met back when it is displayed in the leakage dose Hourly rates do not ignore the leakage radiation dose were measured. Therefore, a mobile health screening in a vehicle outside of the leakage radiation dose to the liver and move on we are not interested twelve barrier leakage radiation dose of defense has a chance to re-evaluate the standards required, and move the vehicle health check using the X-ray increases as the dose per hour, depending on the criteria for choosing the appropriate measures that will require effort.

Study on Consistency of Novice User and Sensitivity of Industrial Types During MSDs Evaluation Using Major Checklists (근골격계질환관련 주요 평가 도구 사용에 있어서의 초보평가자의 일관성 및 업종별 특성에 대한 연구)

  • Im, Su-Jung;Choi, Soon-Young;Park, Dong-Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.14 no.2
    • /
    • pp.123-136
    • /
    • 2012
  • The validity of the results from observational methods such as RULA, REBA, OWAS has been one of major concerns due to their subjective characteristics in determining the posture of interests. There have been many studies regarding validity of the results from each checklist. However, most studies provided only fragmentary rather than comprehensive results in nature. This study specifically tried to analyze consistency of novice user based on intra-observer consistency and sensitivity of industrial types during MSDs(Musculoskekltal Disorders) evaluation with major checklists. In this study, twenty two novice subjects were participated to conduct MSDs evaluation for the forty five jobs from three types of industries(automobile, electronics, hospital). The main results for this study were summarized as follows; 1) The action level based on RULA was always higher than that from REBA and OWAS for all three types of industries., 2) The order of consistency from novice users was OWAS(72.7%(kappa=0.57)) RULA(54.3%(kappa=0.41)), REBA(41.0%(kappa=0.34))., 3) The percentage of agreement between 2nd and 3rd trials was higher than those between 1st and 2nd trials and between 1st and 3rd trials irrespective of industrial types during using RULA and REBA., 4) The average score of automobile industry was higher than those of hospital and electronics industries., 5) The types of jobs associated with five body parts(A1(Front), A2(Interior), A3(Rear), A4(Lower), A5(Door)) in automobile industry showed statistically significant differences in terms of MSDs scores for the body parts considered in each checklists.

A Study of Airborne Microbes in the NSICU According to Number of Persons Who Pass through Every Hour (일지역 신경외과 중환자실내의 통행량에 따른 낙하균 분석)

  • Park Hyoung-Sook;Kang In-Soon;Kim Jin-Wha;Eo Hyun-Ju
    • Journal of Korean Academy of Fundamentals of Nursing
    • /
    • v.11 no.1
    • /
    • pp.41-48
    • /
    • 2004
  • Purpose: The purpose of this study was to analyze the colony count of airborne microbes contamination every hour in the Neurosurgical Intensive Care Unit (NSICU) in order to identify the relationship of colony count to person-visits. Method: Data were collected during from 11:00 a.m. September 5 to 11:00 a.m. September 6, 2002. This study used blood agar & nutrient agar and handtally counter (USA) for collection of airborne microbes and number of person-visits. Data was analyzed using the SPSSWIN 10.0 with means, Pearson correlation coefficient, and simple regression. Result: The result of this study are as follows. Total colony count of airborne microbes for 24 hours in the NSICU was 4,609. Total number of person-visits to the NSICU was 15,347. The highest scores fur the total colony count in different areas of the NSICU was the rear door, followed by the preparation room, and the front entrance, while the lowest count was in the isolation rooms. There was a statistically significant relationship between colony count and number of person-visits to the NSICU. The most frequently airborne microbes in the NSICU were Micrococcus, CNS, Staphylococcus Micrococcus, Aureus. Conclusion: These findings indicate that the number of person-visits in hospitals influences total colony count of airborne microbes. This study contributes to assessment of biological indoor air quality in hospital and in the development of an NSICU care plan.

  • PDF

The Usability Analysis for Ergonomic Evaluation Methods of Work-related Musculoskeletal Disorders (작업관련성 근골격계질환의 인간공학적 평가 기법들에 대한 사용성 평가)

  • Im, Su-Jung;Choi, Soon-Young;Park, Dong-Hyun
    • Journal of the Korea Safety Management & Science
    • /
    • v.13 no.2
    • /
    • pp.83-90
    • /
    • 2011
  • It has been very important to have an exact evaluation for risk factors in order to prevent WMSDs(Work-related Musculoskeletal Disorders). However, most WMSDs evaluation methods have always been some problems of possibilities associated with subjective evaluation. Therefore, this study tried to conduct a sort of usability analysis on three major evaluation methods(OWAS, RULA, REBA). Specifically, major subjects in the study consisted of three parts as follows; comparison of the results between experienced and inexperienced observers, analysis for the consistency of the results in terms of different evaluation times, and analysis for the consistency of the results in terms of different job characteristics(based on the part of the automobile). The results of the study were summarized as follows; 1) There was statistically significant difference of the results by RULA and by REBA between experienced and inexperienced observers. This might be due to the fact that experienced observers have had better ability to detect the important working posture during evaluation. However, the results by OWAS did not give any significantly different results between experienced and inexperienced observers, 2) All three checklists applied by experienced subjects did not show any single result significantly different in terms of different evaluation times. This might have to do with high intra-observer reliability from some of previous studies, 3) The five parts of an automobile were selected as five major jobs with different job characteristics in the automobile industry. Specifically, they were door part, front part(hood, etc.), inside part(dash board, seats, etc.), rear part(trunk etc.), and bottom part. All three methods did not show any significant differences for the results from each observers. Further study on this subject would eventually provide a sophisticated evaluating guidelines for WMSDs regarding determination of observer-specific evaluation, identification of repetitive number of evaluations for stable results for each checklist, determination of job-specific evaluation methods, and so on.