• Title/Summary/Keyword: Realtime Detection

Search Result 177, Processing Time 0.027 seconds

Fundamental Study on the Weld Defects and Its Real-time Monitoring Method (레이저 용접시 용접결함의 실시간 모니터링법 개발에 관한 연구)

  • 김종도
    • Journal of Welding and Joining
    • /
    • v.20 no.1
    • /
    • pp.26-33
    • /
    • 2002
  • This study was undertaken to obtain the fundamental knowledges on the weld deflects and it's realtime monitoring method. The paper describes the results of high speed photography, acoustic emission (AE) detection and plasma light emission (LE) measurements during $CO_2$ laser welding of STS 304 stainless steel and A5083 aluminum alloy in different welding condition. The characteristic frequencies of plasma and keyhole fluctuations at different welding speed and shield gases were measured and compared with the results of Fourier analyses of temporal AE and LE spectra, and they had considerably good agreement with keyhole and plasma fluctuation. Namely, the low frequency peaks of AE and LE shifted to higher frequency range with the welding speed increase, and leer the argon shield gas it was higher than that in helium and nitrogen gases. The low frequencies dominating in fluctuation spectra of LE probably reflect keyhole opening instability. It is possible to monitor the weld bead deflects by analyzing the acoustic and/or plasma light emission signals.

Realtime Apple Quality Monitoring System Based on Deep Learning (딥러닝 기반의 사과 품질 실시간 모니터링 시스템)

  • Chan-seok Bae;Woo-hyuk Jung;Geun-jae Lee;Gyu-ryang Hong;Ji-hyun Kwon;Hongseok Yoo
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2024.01a
    • /
    • pp.297-298
    • /
    • 2024
  • 펜데믹, 전쟁 등을 포함한 국제 정세 변화에 따른 물류대란, 원자재가격 상승 및 환율 급등으로 인해 2023년 기준 대한민국의 물가는 크게 오르고 있는 추세이다. 물가 상승은 사업장의 인건비 부담 증가로 이어지고 있고 특히 노동 집약 산업인 농업 분야에서의 인건비 부담 문제는 더욱 심각한 실정이다. 외국인 근로자 고용이 대안이 될 수 있지만 인건비 절감 효과는 미미하기에 농업계 관계자들은 자동화 시스템 도입에 관심이 집중되고 있다. 따라서, 본 논문에서는 사과 분류 작업 자동화 체계의 핵심 요소에 해당하는 사과 품질 실시간 모니터링 시스템을 제안한다. 제안한 방식에서는 딥러닝 기반의 영상 분석 기법 및 무게 센서 데이터 분석을 통해 사과의 품질에 따른 등급 책정을 자동화 한다.

  • PDF

Comparison of Standard Culture Method and Real-time PCR Assay for Detection of Staphylococcus aureus in Processed and Unprocessed Foods (가공식품과 비가공식품에서의 황색포도상구균 검출을 위한 배지법과 Real-time PCR법의 비교)

  • Lee, Jae-Hoon;Song, Kwang-Young;Hyeon, Ji-Yeon;Hwang, In-Gyun;Kwak, Hyo-Sun;Han, Jeong-A;Chung, Yun-Hee;Seo, Kun-Ho
    • Food Science of Animal Resources
    • /
    • v.30 no.3
    • /
    • pp.410-418
    • /
    • 2010
  • Staphylococcus aureus is one of the major pathogens that can cause staphylococcal infection and food poisoning. In this study, we compared conventional culture methods and real-time PCR for detection of S. aureus in artificially inoculated milk, sausage, raw pork, and vegetable salad. The performance of a coagulase test for confirming S. aureus was also compared with a colony PCR test. Bulk food samples (500 g each) were artificially inoculated with S. aureus and divided into 20 samples (25 g or mL each). All samples were added to tryptic soy broth (225 mL/sample) with 10% NaCl and incubated at $37^{\circ}C$ for 24 h. After the enrichment, broth cultures were streaked onto Baird-Parker (BP) agar with egg yolk tellulite, and incubated at $37^{\circ}C$ for 24 h. In addition, 1 mL of broth cultures was collected to perform real-time PCR. Two suspicious colonies from the BP agar were picked up and plated on nutrient agar and incubated at $37^{\circ}C$ for 24 h followed, by a coagulase confirmation test and a colony PCR analysis. There were no statistical differences between culture methods and realtime PCR in food samples with low background microflora, such as milk and sausage. However, a significant statistical difference was found between the culture methods and real-time PCR for raw pork and vegetable salad. Furthermore, the colony PCR test of the presumptive colonies on BP agar for confirming S. aureus is more accurate and efficient than the coagulase test for unprocessed foods.

Analysis of HBeAg and HBV DNA Detection in Hepatitis B Patients Treated with Antiviral Therapy (항 바이러스 치료중인 B형 간염환자에서 HBeAg 및 HBV DNA 검출에 관한 분석)

  • Cheon, Jun Hong;Chae, Hong Ju;Park, Mi Sun;Lim, Soo Yeon;Yoo, Seon Hee;Lee, Sun Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.23 no.1
    • /
    • pp.35-39
    • /
    • 2019
  • Purpose Hepatitis B virus (hepatitis B virus, HBV) infection is a worldwide major public health problem and it is known as a major cause of chronic hepatitis, liver cirrhosis and liver cancer. And serologic tests of hepatitis B virus is essential for diagnosing and treating these diseases. In addition, with the development of molecular diagnostics, the detection of HBV DNA in serum diagnoses HBV infection and is recognized as an important indicator for the antiviral agent treatment response assessment. We performed HBeAg assay using Immunoradiometric assay (IRMA) and Chemiluminescent Microparticle Immunoassay (CMIA) in hepatitis B patients treated with antiviral agents. The detection rate of HBV DNA in serum was measured and compared by RT-PCR (Real Time - Polymerase Chain Reaction) method Materials and Methods HBeAg serum examination and HBV DNA quantification test were conducted on 270 hepatitis B patients undergoing anti-virus treatment after diagnosis of hepatitis B virus infection. Two serologic tests (IRMA, CMIA) with different detection principles were applied for the HBeAg serum test. Serum HBV DNA was quantitatively measured by real-time polymerase chain reaction (RT-PCR) using the Abbott m2000 System. Results The detection rate of HBeAg was 24.1% (65/270) for IRMA and 82.2% (222/270) for CMIA. Detection rate of serum HBV DNA by real-time RT-PCR is 29.3% (79/270). The measured amount of serum HBV DNA concentration is $4.8{\times}10^7{\pm}1.9{\times}10^8IU/mL$($mean{\pm}SD$). The minimum value is 16IU/mL, the maximum value is $1.0{\times}10^9IU/mL$, and the reference value for quantitative detection limit is 15IU/mL. The detection rates and concentrations of HBV DNA by group according to the results of HBeAg serological (IRMA, CMIA)tests were as follows. 1) Group I (IRMA negative, CMIA positive, N = 169), HBV DNA detection rate of 17.7% (30/169), $6.8{\times}10^5{\pm}1.9{\times}10^6IU/mL$ 2) Group II (IRMA positive, CMIA positive, N = 53), HBV DNA detection rate 62.3% (33/53), $1.1{\times}10^8{\pm}2.8{\times}10^8IU/mL$ 3) Group III (IRMA negative, CMIA negative, N = 36), HBV DNA detection rate 36.1% (13/36), $3.0{\times}10^5{\pm}1.1{\times}10^6IU/mL$ 4) Group IV(IRMA positive, CMIA negative, N = 12), HBV DNA detection rate 25% (3/12), $1.3{\times}10^3{\pm}1.1{\times}10^3IU/mL$ Conclusion HBeAg detection rate according to the serological test showed a large difference. This difference is considered for a number of reasons such as characteristics of the Ab used for assay kit and epitope, HBV of genotype. Detection rate and the concentration of the group-specific HBV DNA classified serologic results confirmed the high detection rate and the concentration in Group II (IRMA-positive, CMIA positive, N = 53).

A design and implementation of Face Detection hardware (얼굴 검출을 위한 SoC 하드웨어 구현 및 검증)

  • Lee, Su-Hyun;Jeong, Yong-Jin
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.44 no.4
    • /
    • pp.43-54
    • /
    • 2007
  • This paper presents design and verification of a face detection hardware for real time application. Face detection algorithm detects rough face position based on already acquired feature parameter data. The hardware is composed of five main modules: Integral Image Calculator, Feature Coordinate Calculator, Feature Difference Calculator, Cascade Calculator, and Window Detection. It also includes on-chip Integral Image memory and Feature Parameter memory. The face detection hardware was verified by using S3C2440A CPU of Samsung Electronics, Virtex4LX100 FPGA of Xilinx, and a CCD Camera module. Our design uses 3,251 LUTs of Xilinx FPGA and takes about 1.96${\sim}$0.13 sec for face detection depending on sliding-window step size, when synthesized for Virtex4LX100 FPGA. When synthesized on Magnachip 0.25um ASIC library, it uses about 410,000 gates (Combinational area about 345,000 gates, Noncombinational area about 65,000 gates) and takes less than 0.5 sec for face realtime detection. This size and performance shows that it is adequate to use for embedded system applications. It has been fabricated as a real chip as a part of XF1201 chip and proven to work.

Premature Ventricular Contraction Classification through R Peak Pattern and RR Interval based on Optimal R Wave Detection (최적 R파 검출 기반의 R피크 패턴과 RR간격을 통한 조기심실수축 분류)

  • Cho, Ik-sung;Kwon, Hyeog-soong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.22 no.2
    • /
    • pp.233-242
    • /
    • 2018
  • Previous works for detecting arrhythmia have mostly used nonlinear method such as artificial neural network, fuzzy theory, support vector machine to increase classification accuracy. Most methods require higher computational cost and larger processing time. Therefore it is necessary to design efficient algorithm that classifies PVC(premature ventricular contraction) and decreases computational cost by accurately detecting feature point based on only R peak through optimal R wave. For this purpose, we detected R wave through optimal threshold value and extracted RR interval and R peak pattern from noise-free ECG signal through the preprocessing method. Also, we classified PVC in realtime through RR interval and R peak pattern. The performance of R wave detection and PVC classification is evaluated by using 9 record of MIT-BIH arrhythmia database that included over 30. The achieved scores indicate the average of 99.02% in R wave detection and the rate of 94.85% in PVC classification.

Species-specific Marker of Phytophthora pinifolia for Plant Quarantine in Korea (국내 식물검역대상 Phytophthora pinifolia의 PCR 검출을 위한 종 특이적 마커 개발)

  • Kim, Narae;Choi, You Ri;Seo, Mun Won;Song, Jeong Young;Kim, Hong Gi
    • The Korean Journal of Mycology
    • /
    • v.44 no.2
    • /
    • pp.103-107
    • /
    • 2016
  • To establish a rapid and accurate detection of Phytophthora pinifolia, which is a quarantine pathogenic fungus in Korea, a species-specific primer was developed based on the ras-related protein (Ypt1) gene. Species-specific primer based on the DNA sequences of Ypt1 gene amplified 193 bp polymerase chain reaction (PCR) product for P. pinifolia. The primer pair yielded the predicted PCR product size exactly in testing with target pathogen DNAs, but not from the other 10 species of Phytophthora and 14 species of other phytopathogenic fungi. The primer pair also showed only the species-specific amplification curve on realtime PCR on target pathogen DNA. The detection sensitivity of real time PCR using species-specific primer pair was 10 to 100 times higher than conventional PCR, with 1 to $10pg/{\mu}L$.

A Technique of Feature Vector Generation for Eye Region Using Embedded Information of Various Color Spaces (다양한 색공간 정보를 이용한 눈 영역의 특징벡터 생성 기법)

  • Park, Jung-Hwan;Shin, Pan-Seop;Kim, Guk-Boh;Jung, Jong-Jin
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.64 no.1
    • /
    • pp.82-89
    • /
    • 2015
  • The researches of image recognition have been processed traditionally. Especially, face recognition technology has been received attractions with advance and applied to various areas according as camera sensor embedded into many devices such as smart phone. In this study, we design and develop a feature vector generation technique of face for making animation caricatures using methods for face detection which are previous stage of face recognition. At first, we detect both face region and detailed eye region of component element by Viola&Johns's realtime detection method which are called as ROI(Region Of Interest). And then, we generate feature vectors of eye region by utilizing factors as opposed to the periphery and by using appearance information of eye. At this point, we focus on the embedded information in many color spaces to overcome the problems which can be occurred by using one color space. We propose a feature vector generation method using information from many color spaces. Finally, we experiment the test of feature vector generation by the proposed method with enough quantity of sample picture data and evaluate the proposed method for factors of estimating performance such as error rate, accuracy and generation time.

Study of Optical Fiber Sensor Systems for the Simultaneous Monitoring of Fracture and Strain in Composite Laminates (복합적층판의 변형파손 동시감지를 위한 광섬유 센서 시스템에 관한 연구)

  • 방형준;강현규;홍창선;김천곤
    • Composites Research
    • /
    • v.16 no.3
    • /
    • pp.58-67
    • /
    • 2003
  • To perform the realtime strain and fracture monitoring of the smart composite structures, two optical fiber sensor systems are proposed. The two types of the coherent sources were used for fracture signal detection - EDFA with FBG and EDFA with Fabry-Perot filter. These sources were coupled to EFPI sensors imbedded in composite specimens. To understand the characteristics of matrix crack signals, at first, we performed tensile tests using surface attached PZT sensors by changing the thickness and width of the specimens. This paper describes the implementation of time-frequency analysis such as short time Fourier transform (STFT) and wavelet transform (WT) for the quantitative evaluation of fracture signals. The experimental result shows the distinctive signal features in frequency domain due to the different specimen shapes. And, from the test of tensile load monitoring using optical fiber sensor systems, measured strain agreed with the value of electric strain gage and the fracture detection system could detect the moment of damage with high sensitivity to recognize the onset of micro-crack fracture signal.

A Study on Motion Detection of Object Using Active Block Matching Algorithm (능동적 블록정합기법을 이용한 객체의 움직임 검출에 관한 연구)

  • Lee Chang-Soo;Park Mi-Og;Lee Kyung-Seok
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.4C
    • /
    • pp.407-416
    • /
    • 2006
  • It is difficult for the movement detection of an object through a camera to detect exact movement because of unnecessary noises and changes of the light. It can be recognized as a background, when there is no movement after the inflow of an object. Therefore, It is necessary to fast search algorithm for tracking and extract of object that is realtime image. In this thesis, we evaluate the difference of the input vision based on initial image and replace some pixels in process of time. When there is a big difference between background image and input image, we decide it is the point of the time of the object input and then extract boundary point of it. The extracted boundary point detects precise movement of the object by creating minimum block of it and searching block that maintaining distance. The designed and embodied system shows more than 95% accuracy in the performance test.