• Title/Summary/Keyword: Reactor core calculation

Search Result 146, Processing Time 0.023 seconds

Computer Based Core Monitoring System for an Operating CANDU Reactor

  • Yoon Moon Young;Kwon Hwan O.;Kim Kyung Hwa;Yeom Choong Sub
    • Nuclear Engineering and Technology
    • /
    • v.36 no.1
    • /
    • pp.53-63
    • /
    • 2004
  • The research was performed to develop a CANDU-6 Core Monitoring System(CCMS) that enables operators to have efficient core management by monitoring core power distribution, burnup distribution, and the other important core variables and managing the past core history for Wolsong nuclear power plant unit 1. The CCMS uses Reactor Fueling Simulation Program(RFSP, developed by AECL) for continuous core calculation by integrating the algorithm and assumptions validated and uses the information taken from Digital Control Computer(DCC) for the purpose of producing basic input data. The CCMS has two modules; CCMS server program and CCMS client program. The CCMS server program performs automatic and continuous core calculation and manages overall output controlled by DataBase Management System. The CCMS client program enables users to monitor current and past core status in the predefined GUI(Graphic-User Interface) environment. For the purpose of verifying the effectiveness of CCMS, we compared field-test data with the data used for Wolsong unit 1 operation. In the verification the mean percent differences of both cases were the same($0.008\%$), which showed that the CCMS could monitor core behaviors well.

Application of TULIP/STREAM code in 2-D fast reactor core high-fidelity neutronic analysis

  • Du, Xianan;Choe, Jiwon;Choi, Sooyoung;Lee, Woonghee;Cherezov, Alexey;Lim, Jaeyong;Lee, Minjae;Lee, Deokjung
    • Nuclear Engineering and Technology
    • /
    • v.51 no.8
    • /
    • pp.1871-1885
    • /
    • 2019
  • The deterministic MOC code STREAM of the Computational Reactor Physics and Experiment (CORE) laboratory of Ulsan National Institute of Science and Technology (UNIST), was initially designed for the calculation of pressurized water reactor two- and three-dimensional assemblies and cores. Since fast reactors play an important role in the generation-IV concept, it was decided that the code should be upgraded for the analysis of fast neutron spectrum reactors. This paper presents a coupled code - TULIP/STREAM, developed for the fast reactor assembly and core calculations. The TULIP code produces self-shielded multi-group cross-sections using a one-dimensional cylindrical model. The generated cross-section library is used in the STREAM code which solves eigenvalue problems for a two-dimensional assembly and a multi-assembly whole reactor core. Multiplication factors and steady-state power distributions were compared with the reference solutions obtained by the continuous energy Monte-Carlo code MCS. With the developed code, a sensitivity study of the number of energy groups, the order of anisotropic PN scattering, and the multi-group cross-section generation model was performed on the keff and power distribution. The 2D core simulation calculations show that the TULIP/STREAM code gives a keff error smaller than 200 pcm and the root mean square errors of the pin-wise power distributions within 2%.

Multi-group Diffusion Analysis on Kori Reactor's Fuel Loading Patterns (고리원자로 핵연료의 장진방법에 대한 다군확산적 효과분석)

  • Chang Kun Lee
    • 전기의세계
    • /
    • v.22 no.1
    • /
    • pp.20-27
    • /
    • 1973
  • The multi-group diffusion theory is applied to the analysis of the currently constructing Kori reactor core which is to be refuelled by 3-region fuel loading pattern and also to the comparative study on a conceptually designed 5-region reactor core, under the condition that, apart from the thermal-hydraulic considerations, all the input data referred to here in are assumed to be identical for both cases. The numerical calculation is carried out for quantitative analysis of the characteristics of the two fuel loading patterns in details, and the calculated results show that, so far as the nuclear aspects are concerned, the characteristics of the 5-region reactor core are proved to be superior to those of Kori's 3-region reactor core in general.

  • PDF

AEGIS: AN ADVANCED LATTICE PHYSICS CODE FOR LIGHT WATER REACTOR ANALYSES

  • Yamamoto, Akio;Endo, Tomohiro;Tabuchi, Masato;Sugimura, Naoki;Ushio, Tadashi;Mori, Masaaki;Tatsumi, Masahiro;Ohoka, Yasunori
    • Nuclear Engineering and Technology
    • /
    • v.42 no.5
    • /
    • pp.500-519
    • /
    • 2010
  • AEGIS is a lattice physics code incorporating the latest advances in lattice physics computation, innovative calculation models and efficient numerical algorithms and is mainly used for light water reactor analyses. Though the primary objective of the AEGIS code is the preparation of a cross section set for SCOPE2 that is a three-dimensional pin-by-pin core analysis code, the AEGIS code can handle not only a fuel assembly but also multi-assemblies and a whole core geometry in two-dimensional geometry. The present paper summarizes the major calculation models and part of the verification/validation efforts related to the AEGIS code.

Development and verification of a Monte Carlo two-step method for lead-based fast reactor neutronics analysis

  • Yiwei Wu;Qufei Song;Ruixiang Wang;Yao Xiao;Hanyang Gu;Hui Guo
    • Nuclear Engineering and Technology
    • /
    • v.55 no.6
    • /
    • pp.2112-2124
    • /
    • 2023
  • With the rise of economic and safety standards for nuclear reactors, new concepts of Gen-IV reactors and modular reactors showed more complex designs that challenge current tools for reactor physics analysis. A Monte Carlo (MC) two-step method was proposed in this work. This calculation scheme uses the continuous-energy MC method to generate multi-group cross-sections from heterogeneous models. The multi-group MC method, which can adapt locally-heterogeneous models, is used in the core calculation step. This calculation scheme is verified using a Gen-IV modular lead-based fast reactor (LFR) benchmark case. The influence of homogenized patterns, scatter approximations, flux separable approximation, and local heterogeneity in core calculation on simulation results are investigated. Results showed that the cross-sections generated using the 3D assembly model with a locally heterogeneous representation of control rods lead to an accurate estimation with less than 270 pcm bias in core reactivity, 0.5% bias in control rod worth, and 1.5% bias on power distribution. The study verified the applicability of multi-group cross-sections generated with the MC method for LFR analysis. The study also proved the feasibility of multi-group MC in core calculation with local heterogeneity, which saves 85% time compared to the continuous-energy MC.

Calculation of Reactor Pressure Vessel Fluence Using TORT Code

  • Shin, Chul-Ho;Kim, Jong kyung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1998.05b
    • /
    • pp.771-776
    • /
    • 1998
  • TORT is employed for fast neutron fluence calculation at the reactor pressure vessel. KORI Unit 1 reactor at cycle 1 is modeled for this calculation. Three-dimensional cycle averaged assembly power distributions for KORI Vnit 1 at cycle 1 are calculated by using the core physics code, NESTLE 5.0. The root mean square error is within 4.3% compared with NDR (Nuclear Design Report) far all burnup steps. The C/E (Calculated/Experimental) values for the in-vessel dosimeters distribute between 0.98 and 1.36. The most updated cross-section library. BUGLE-96 based on ENDF/B-VI is used for the neutron fluence calculation. The makimum fast neutron nun calculated on reactor pressure vessel for KORI Unit 1 operated for 411.41 effgctive full power days is 1.784x10$^{18}$ n/$\textrm{cm}^2$. The position of the maximum neutron fluence in RPV wall 1/4 T is nearby 60cm below the midplane at zero degree.

  • PDF

Sensitivity Studies on Thermal Margin of Reactor Vessel Lower Head During a Core Melt Accident

  • Kim, Chan-Soo;Kune Y. Suh
    • Nuclear Engineering and Technology
    • /
    • v.32 no.4
    • /
    • pp.379-394
    • /
    • 2000
  • As an in-vessel retention (IVR) design concept in coping with a severe accident in the nuclear power plant during which time a considerable amount of core material may melt, external cooling of the reactor vessel has been suggested to protect the lower head from overheating due to relocated material from the core. The efficiency of the ex-vessel management may be estimated by the thermal margin defined as the ratio of the critical heat flux (CHF)to the actual heat flux from the reactor vessel. Principal factors affecting the thermal margin calculation are the amount of heat to be transferred downward from the molten pool, variation of heat flux with the angular position, and the amount of removable heat by external cooling In this paper a thorough literature survey is made and relevant models and correlations are critically reviewed and applied in terms of their capabilities and uncertainties in estimating the thermal margin to potential failure of the vessel on account of the CHF Results of the thermal margin calculation are statistically treated and the associated uncertainties are quantitatively evaluated to shed light on the issues requiring further attention and study in the near term. Our results indicated a higher thermal margin at the bottom than at the top of the vessel accounting for the natural convection within the hemispherical molten debris pool in the lower plenum. The information obtained from this study will serve as the backbone in identifying the maximum heat removal capability and limitations of the IVR technology called the Cerium Attack Syndrome Immunization Structures (COASISO) being developed for next generation reactors.

  • PDF

Power Density Distribution Calculation of a Pressurized Water Reactor with Fullscope Explicit Modeling by MCNP Code

  • Kim, Jong-Oh;Kim, Jong-Kyung
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1996.05a
    • /
    • pp.179-184
    • /
    • 1996
  • Power density distribution and criticality of a pressurized water reactor are calculated with a Monte Carlo calculation using the MCNP code. The MCNP model is based on one-eighth core symmetry. Individual fuel assemblies are modeled with fullscope three dimensional description except grid spacer. The fuel rod is divided into eight axial segments. Core internals above and below the active fuel region is represented as coolant. After 400 cycle calculations, the system converges to a k value of 1.09151$\pm$0.00066. Fission reaction rate in each rod is also calculated to use as the source term in pressure vessel fluence calculation.

  • PDF

Reactor Physics Study Related to Subcriticality of Accelerator Driven System By AESJ/JAERl Working Party

  • Iwasaki, Tomohiko
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2002.05a
    • /
    • pp.66-66
    • /
    • 2002
  • Under Atomic Energy Society of Japan (AESJ) and Japan Atomic Energy Research Institute (JAERO, a Working Party on Reactor Physics of Accelerator-Driven System (ADS-WP) has been set since March 1999 to review and investigate special subjects related to reactor physics research of Accelerator-Driven System (ADS). In the ADSWP, the extensive and aggressive activity is being made by 25 professional members in the field of reactor physics in Japan. The ADS is now studying three subjects related to subcriticality of ADS; (1) calculation accuracy of sub criticality on ADS, (2) critical safety issues of ADS, and (3) theoretical review of subcriticality and its measurement methods. This paper describes two topics related to the subjects (1) and (2); one is an analysis of maximum reactivity potentially inserted to a subcritical core and the other is a benchmark proposal for checking calculation accuracy of sub criticality on ADS. The full specification of the calculation benchmark will be supplied by June 2002. Researchers from overseas, especially from Korea, are welcome to join this benchmark

  • PDF

Development of a 3D thermohydraulic-neutronic coupling model for accident analysis in research miniature neutron source reactor (MNSR)

  • Ahmadi, M.;Rabiee, A.;Pirouzmand, A.
    • Nuclear Engineering and Technology
    • /
    • v.51 no.7
    • /
    • pp.1776-1783
    • /
    • 2019
  • To accurately analyze the accidents in nuclear reactors, a thermohydraulic-neutronic coupling calculation is required to solve fluid dynamics and nuclear reactor kinetics equations in fine cells simultaneously and evaluate the local effects of neutronic and thermohydraulic parameters on each other. In the present study, a 3D thermohydraulic-neutronic coupling model is developed, validated and then applied for Isfahan MNSR (Miniature Neutron Source reactor) safety analysis. The proposed model is developed using FLUENT software and user defined functions (UDF) are applied to simulate the neutronic behavior of MNSR. The validation of the proposed model is first evaluated using 1mk reactivity insertion experiment into Isfahan MNSR core. Then, the developed coupling code is applied for a design basis accident (DBA) scenario analysis with the insertion of maximum allowed cold core reactivity of 4 mk. The results show that the proposed model is able to predict the behavior of the reactor core under normal and accident conditions with a good accuracy.