Power Density Distribution Calculation of a Pressurized Water Reactor with Fullscope Explicit Modeling by MCNP Code

  • Published : 1996.05.01

Abstract

Power density distribution and criticality of a pressurized water reactor are calculated with a Monte Carlo calculation using the MCNP code. The MCNP model is based on one-eighth core symmetry. Individual fuel assemblies are modeled with fullscope three dimensional description except grid spacer. The fuel rod is divided into eight axial segments. Core internals above and below the active fuel region is represented as coolant. After 400 cycle calculations, the system converges to a k value of 1.09151$\pm$0.00066. Fission reaction rate in each rod is also calculated to use as the source term in pressure vessel fluence calculation.

Keywords