• Title/Summary/Keyword: Reactive Power Compensation

Search Result 297, Processing Time 0.025 seconds

Power Quality Improvement using DVR (DVR을 이용한 전력품질 개선)

  • Kim, Seong-Hwan
    • Journal of IKEEE
    • /
    • v.25 no.3
    • /
    • pp.462-466
    • /
    • 2021
  • DVR is a device that compensates for voltage fluctuations in distribution lines and is generally used in combination with a device that compensates reactive power and improve power factor. Such a coupling compensator has the disadvantage of being relatively difficult to control and bulky. In this paper, mathematical analysis of the maximum magnitude of the compensation voltage, phase angle, compensable reactive power and active power was performed in order to simultaneously compensate the reactive power and voltage fluctuation of the distribution line by applying the power angle control method of the DVR. A control algorithm for charging active power to the battery and supplying stored energy when the voltage is changed was developed and the results were confirmed through Matlab simulation.

Adaptive Compensation Technique of Parameter Variation for Quick Torque Response of an Induction Motor Drive (유도전동기의 속응 토크제어를 위한 파라미터 변동의 적응보상기법)

  • 손진근;정을기;김준환;전희종
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.3
    • /
    • pp.206-213
    • /
    • 1998
  • In this paper, an adaptive compensation technique for parameter variation is proposed which can perform quick torque response in vector control of an induction motors. To solve the problem of control performance degradation due to parameter variation in an induction motor, a rotor resistance estimation is performed by the model reference adaptive control(MRAC). The algorithm of rotor resistance estimation is composed of the error relationship which is generated between a motor real instantaneous reactive power and an estimated instantaneous reactive power. The advantage of such a real reactive power reference model is independence of the motor parameter variation. The estimation rotor resistance values are applied to the direct vector control system with a flux observer. Finally, the simulations and experiment are presented to validate the rotor resistance estimation algorithm of induction motor.

  • PDF

Improvement of Responsivity of Unified Power Flow Controller in Digital Control System

  • Hamasaki, Shin-ichi;Miyazaki, Shinya;Takaki, Tsuyoshi;Tsuji, Mineo
    • Journal of international Conference on Electrical Machines and Systems
    • /
    • v.3 no.3
    • /
    • pp.354-361
    • /
    • 2014
  • The Unified Power Flow Controller (UPFC) can flexibly manage power flow and maintain line voltage. The UPFC consists of two inverters in parallel side and series side. In parallel side, the reactive power can be compensated to improve the power factor. In series side, the voltage drop can be compensated to maintain proper line voltage. It is necessary for the operation in both sides to output the current and the voltage quickly and accurately. As the method for the UPFC control, the deadbeat control with state observer is applied. The deadbeat control is able to realize a quick response of the current and voltage control for only a sampling period compared with the general PI control. A principle and simulation results are presented in this paper.

Instantaneous Reactive Power Compensator using Current Controlled PWM Converter (전류제어형 PWM 컨버터에 의한 순시 무효전력 보상장치)

  • 최재호;김상훈;박민호
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.38 no.7
    • /
    • pp.539-548
    • /
    • 1989
  • This paper describes an instantaneous reactive power compensator aimed at the compensation of reactive power and current harmonics of a thyristor load. A new definition of the instantaneous reactive power consisting of both displacement of fundamental current and harmonic distortion current is proposed and the physical meaning is investigated from the viewpoint of an instantaneous power flow. The instantaneous reactive power is calculated from the feedback of instantaneous voltage, current and is compensated by the current controlled PWM converter connected in parallel with the load. The PWM converter operates as a high performance current control scheme, because adopts the excellent current controlled PWM technique based on the current deviation vector. Both simulation and experimental results show good compensating performances in steady and transient state.

STATCOM Control for Balancing the Unbalanced Loads (불평형 부하의 평형화를 위한 STATCOM 제어)

  • Im, Su-Saeng;Lee, Eun-Ung;Kim, Hong-Gwon
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.49 no.8
    • /
    • pp.522-528
    • /
    • 2000
  • In this paper, a static synchronous compensator(STATCOM), which in general compensates reactive power, is proposed in order to balance the unbalanced loads. Reference values for the compensation of the unbalanced loads currents are determined by 3-phase circuit analysis result. Also the STATCOM control unit is designed considering the proposed compensation scheme for the unbalanced loads. As a result, the effectiveness of the STATCOM for balancing the load currents is verified by computer simulations.

  • PDF

Electric Arc Furnace Voltage Flicker Mitigation by Applying a Predictive Method with Closed Loop Control of the TCR/FC Compensator

  • Kiyoumarsi, Arash;Ataei, Mohhamad;Hooshmand, Rahmat-Allah;Kolagar, Arash Dehestani
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.116-128
    • /
    • 2010
  • Modeling of the three phase electric arc furnace and its voltage flicker mitigation are the purposes of this paper. For modeling of the electric arc furnace, at first, the arc is modeled by using current-voltage characteristic of a real arc. Then, the arc random characteristic has been taken into account by modulating the ac voltage via a band limited white noise. The electric arc furnace compensation with static VAr compensator, Thyristor Controlled Reactor combined with a Fixed Capacitor bank (TCR/FC), is discussed for closed loop control of the compensator. Instantaneous flicker sensation curves, before and after accomplishing compensation, are measured based on IEC standard. A new method for controlling TCR/FC compensator is proposed. This method is based on applying a predictive approach with closed loop control of the TCR/FC. In this method, by using the previous samples of the load reactive power, the future values of the load reactive power are predicted in order to consider the time delay in the compensator control. Also, in closed loop control, two different approaches are considered. The former is based on voltage regulation at the point of common coupling (PCC) and the later is based on enhancement of power factor at PCC. Finally, in order to show the effectiveness of the proposed methodology, the simulation results are provided.

LCL Resonant Compensation of Movable ICPT Systems with a Multi-load

  • Hua, Jie;Wang, Hui-Zhen;Zhao, Yao;Zou, Ai-Long
    • Journal of Power Electronics
    • /
    • v.15 no.6
    • /
    • pp.1654-1663
    • /
    • 2015
  • Compared to LC resonance, LCL resonance has distinct advantages such as a large resonant capability, low voltage and current stresses of the power device, constant voltage or current output characteristics, and fault-tolerance capability. Thus, LCL resonant compensation is employed for a movable Inductive Contactless Power Transfer (ICPT) system with a multi-load in this paper, which achieves constant current output characteristics. Peculiarly, the primary side adopts a much larger compensation inductor than the primary leakage inductor to lower the reactive power, reduce the input current ripple, generate a large current in the primary side, and realize soft-switching. Furthermore, this paper proposes an approximate resonant point for large inductor-ratio LCL resonant compensation through fundamental wave analysis. In addition, the PWM control strategy is used for this system to achieve constant current output characteristics. Finally, an experimental platform is built, whose secondary E-Type coils can ride and move on a primary rail. Simulations and experiments are conducted to verify the effectiveness and accuracy of both the theory and the design method.

Control Strategy for Selective Compensation of Power Quality Problems through Three-Phase Four-Wire UPQC

  • Pal, Yash;Swarup, A.;Singh, Bhim
    • Journal of Power Electronics
    • /
    • v.11 no.4
    • /
    • pp.576-582
    • /
    • 2011
  • This paper presents a novel control strategy for selective compensation of power quality (PQ) problems, depending upon the limited rating of voltage source inverters (VSIs), through a unified power quality conditioner (UPQC) in a three-phase four-wire distribution system. The UPQC is realized by the integration of series and shunt active power filters (APFs) sharing a common dc bus capacitor. The shunt APF is realized using a three-phase, four-leg voltage source inverter (VSI), while a three-leg VSI is employed for the series APF of the three-phase four-wire UPQC. The proposed control scheme for the shunt APF, decomposes the load current into harmonic components generated by consumer and distorted utility. In addition to this, the positive and negative sequence fundamental frequency active components, the reactive components and harmonic components of load currents are decomposed in synchronous reference frame (SRF). The control scheme of the shunt APF performs with priority based schemes, which respects the limited rating of the VSI. For voltage harmonic mitigation, a control scheme based on SRF theory is employed for the series APF of the UPQC. The performance of the proposed control scheme of the UPQC is validated through simulations using MATLAB software with its Simulink and Power System Block set toolboxes.

A Study on Optimization of Voltage and Reactive Power Planning (전압 및 무효전력 계획의 최적화에 관한 연구)

  • Kim, Joon-Hyun;Kim, Tae-Gyun
    • Proceedings of the KIEE Conference
    • /
    • 1988.07a
    • /
    • pp.859-862
    • /
    • 1988
  • This paper discusses one overall reactive power installation pattern that will satisfy system performance constraints for base case. The cost of installation is minimized, Existing controllers are fully utilized prior to any addition of new installation. Installation pattern for the required new shunt compensation is comprised of discrete, standard size components.

  • PDF

Static Var Compensator Using Current Source PWM Converter (전류형 PWN 콘버어터의 희한 정지형 무효전력 보상장치에 관한연구)

  • 김철우;권순재;김광태
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.39 no.11
    • /
    • pp.1183-1190
    • /
    • 1990
  • In this paper, instantaneous reactive power compensation algorithm is proposed and analyzed. The static Var generator developed in this paper is the current source PWM converter using hysteresis comparator method, which compensates the reactive power by detecting each instantaneous phase voltage and line current, independently. Some aspects on the static Var compensator-such as inductance, capacitance, hysteresis width, and switching frequency, etc.-are discussed. The dynamic performances are examined through digital simulation and experimental test.

  • PDF