• 제목/요약/키워드: Reactive Power Allocation

검색결과 13건 처리시간 0.017초

Optimum Allocation of Reactive Power in Real-Time Operation under Deregulated Electricity Market

  • Rajabzadeh, Mahdi;Golkar, Masoud A.
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권3호
    • /
    • pp.337-345
    • /
    • 2009
  • Deregulation in power industry has made the reactive power ancillary service management a critical task to power system operators from both technical and economic perspectives. Reactive power management in power systems is a complex combinatorial optimization problem involving nonlinear functions with multiple local minima and nonlinear constraints. This paper proposes a practical market-based reactive power ancillary service management scheme to tackle the challenge. In this paper a new model for voltage security and reactive power management is presented. The proposed model minimizes reactive support cost as an economic aspect and insures the voltage security as a technical constraint. For modeling validation study, two optimization algorithm, a genetic algorithm (GA) and particle swarm optimization (PSO) method are used to solve the problem of optimum allocation of reactive power in power systems under open market environment and the results are compared. As a case study, the IEEE-30 bus power system is used. Results show that the algorithm is well competent for optimal allocation of reactive power under practical constraints and price based conditions.

무효전력 비용 산정에 관한 연구 (A Study on Cost Evaluation for Capacitive Reactive Power)

  • 정춘식;박정도;문영현
    • 대한전기학회논문지:전력기술부문A
    • /
    • 제53권3호
    • /
    • pp.182-186
    • /
    • 2004
  • In this paper, the cost for capacitive reactive flower is evaluated considering the deregulation environment. For the cost assessment of reactive power, the duration curve of reactive power demand is introduced and investigated. Also, a guideline is suggested to estimate the Q-cost by using the inverse of the Q-demand duration curve. In order to obtain optimal real reactive power allocation, a new algorithm is proposed by using the piecewise linearization of the inverse of the Q-demand duration curve and the Linear Programming technique. The proposed method is tested with sample systems using MATLAB. The test results show that the algorithm yields reasonable reactive power allocation and Provides fair cost evaluation for reactive power.

Coordinated Control Strategies with and without Circulating Current in Unified Power Quality

  • Feng, Xing-tian;Zhang, Zhi-hua
    • Journal of Power Electronics
    • /
    • 제15권5호
    • /
    • pp.1348-1357
    • /
    • 2015
  • Under traditional unified power quality conditioner (UPQC) control, a UPQC series converter (SC) is mainly used to handle grid-side power quality problems while its parallel converter (PC) is mainly used to handle load-side power quality problems. The SC and PC are relatively independent. The SC is usually in standby mode and it only runs when the grid voltage abruptly changes. In this paper, novel UPQC coordinated control strategies are proposed which use the SC to share the reactive power compensation function of the PC especially without grid-side power quality problems. However, in some cases, there will be a circulating current between the SC and the PC, which will probably influence the compensation fashion, the compensation capacity, or the normal work of the UPQC. Through an active power circulation analysis, strategies with and without a circulating current are presented which fuses the reactive power allocation strategy of the SC and the PC, the composite control strategy of the SC and the compensation strategy of the DC storage unit. Both of the strategies effectively solve the SC long term idle problem, limit the influence of the circulating current, optimize all of the UPQC units and reduce the production cost. An analysis, along with simulation andexperimental results, is presented to verify the feasibility and effectiveness of the proposed control strategies.

전압.무효전력제어에 있어서의 최적운전 목표상태의 간략결정법 (A simplified method for the determination of the optimal operating patterns in system voltage-reactive power control)

  • 송길영
    • 전기의세계
    • /
    • 제15권3호
    • /
    • pp.1-7
    • /
    • 1966
  • The past several years have strongly anticipated the advent of a more integrated system control combining active power and voltage-reactive power controls. This paper presents a new approach to the intergrated system control with primary emphasis on the development of a new control method which combines the conventional economical load dispatching(ELD) and voltage-reactive power controls. The control method, in its fundamental principle, first determines the optimal active power allocation in accordance with the conventional ELD controller. By a proper manipulation of the remaining reactive power sources in the system, the control method then reduces the transmission losses of the system by the adjustment of system voltage distribution and also by the proper allotment of reactive power flows.

  • PDF

전렬계통의 합리적 운용제어에 관한 연구 (A Study on the Optimum Operational Control of Power System)

  • 정재길;박영문
    • 대한전기학회논문지
    • /
    • 제33권10호
    • /
    • pp.410-422
    • /
    • 1984
  • This paper presents a new practical method for optimal active and reactive power control for the economic operation in electrical power system, and the programs are developed for digital computer solution. The major features and techniques of this paper are as follows: 1) The method is presented for finding the equivalent active power balance equation applying the sparse Jacobian matrix of power flow equation instead of using B constant as active power balance equation considering transmission loss, and thus for determining directly optimal active power allocation berween generator unitw satisfying the equality and inequality constraints. 2) The method is proposed for solving directly the optimum economim dispatch problem without using gradient method and penalty function for both active and reactive power control. As a result, the computing time are reduced and convergence characteristic is remarkably improved. 3) Unlike most of conventional methods which adopt the transmission loss as a objective function for reactive power control, the total fuel cost of themal power plant is adopted as objective function for both active and reactive power control. consequently, more reasonable and economic profit can be achieved.

Power Flow Algorithm for Weakly Meshed Distribution Network with Distributed Generation Based on Loop-analysis in Different Load Models

  • Su, Hongsheng;Zhang, Zezhong
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권2호
    • /
    • pp.608-619
    • /
    • 2018
  • As distributed generation (DG) is connected to grid, there is new node-type occurring in distribution network. An efficient algorithm is proposed in this paper to calculate power flow for weakly meshed distribution network with DGs in different load models. The algorithm respectively establishes mathematical models focusing on the wind power, photovoltaic cell, fuel cell, and gas turbine, wherein the different DGs are respectively equivalent to PQ, PI, PQ (V) and PV node-type. When dealing with PV node, the algorithm adopts reactive power compensation device to correct power, and the reactive power allocation principle is proposed to determine reactive power initial value to improve convergence of the algorithm. In addition, when dealing with the weakly meshed network, the proposed algorithm, which builds path matrix based on loop-analysis and establishes incident matrix of node voltage and injection current, possesses good convergence and strong ability to process the loops. The simulation results in IEEE33 and PG&G69 node distribution networks show that with increase of the number of loops, the algorithm's iteration times will decrease, and its convergence performance is stronger. Clearly, it can be effectively used to solve the problem of power flow calculation for weakly meshed distribution network containing different DGs.

Effect of Mutual Interference and Channel Estimation Error on Outage Performance of Reactive Relay Selection in Unlicensed Systems

  • Ho-Van, Khuong
    • Journal of Communications and Networks
    • /
    • 제17권4호
    • /
    • pp.362-369
    • /
    • 2015
  • This study addresses the effects of channel estimation error and mutual interference between licensed and unlicensed systems on outage performance of reactive relay selection in unlicensed systems over independent non-identical (i.n.i) Rayleigh fading channels and under both the maximum transmit power constraint and primary outage constraint. Toward this end, power allocation for unlicensed users is first recommended to satisfy both constraints and account for channel estimation error and mutual interference. Then, we derive an exact closed-form outage probability representation for unlicensed systems to quickly evaluate this effect in key operation parameters. Various results corroborate the derived expressions and provide useful insights into system performance.

Power Tracing Method for Transmission Usage Allocation Considering Reactive Power

  • Han Choong-Kyo;Park Jong-Keun;Jung Hae-Sung
    • KIEE International Transactions on Power Engineering
    • /
    • 제5A권1호
    • /
    • pp.79-84
    • /
    • 2005
  • In many countries, the electric power industry is undergoing significant changes known as deregulation and restructuring. These alterations introduce competition in generation and retail and require open access to the transmission network. The competition of the electric power industry causes many issues to surface. Among them, unbundling of the transmission service is probably the most complicated as it is a single and integrated sector and the transmission revenue requirement must be allocated to market participants in a fair way. In these situations, it is valuable to research the methodologies to allocate transmission usage. The power tracing method offers useful information such as which generators supply a particular load or how much each generator (load) uses a particular transmission line. With this information, we can allocate required transmission revenue to market participants. Recently, several algorithms were proposed for tracing power flow but there is no dominant power tracing method. This paper proposes a power tracing method based on graph theory and complex-current distribution. For practicability, the proposed method for transmission usage allocation is applied to IEEE 30 buses and compared with the method proposed by Felix F.Wu.

퍼지 선형계획법을 적용한 전력계통의 최적운용에 관한 연구 (Optimum Operation of Power System Using Fuzzy Linear Programming)

  • 박성대;정재길;조양행
    • 한국조명전기설비학회지:조명전기설비
    • /
    • 제8권1호
    • /
    • pp.37-45
    • /
    • 1994
  • 본 논문은 전력계통 운용에 관한 합리적인 유효전력 및 무효전력 제어방법을 제시한 논문으로 무효전력 제어에 퍼지 선형계획법을 적용하여 목적함수의 값을 최소화하고 전체 계산시간을 단축시키고 운용의 융통성을 주기 위하여 시도한 논문으로 본 논문의 특징은 다음과 같다. 1) 유효전력 제어는 선로손실을 고려한 전력수급 평형식으로서 B정수를 이용하지 않고 전력 조류 방정식의 쟈코비 행렬의 스파스한 성질을 이용하여 간단히 계산하고 Lagrange함수법을 이용함으로써 계산시간을 단축시키고 기억용량을 대폭 경감시킬 수 있으며 반복계산을 하지 않고 직접 발전기의 최적부하 배분량을 결정할 수 있다. 2) 무효전력 제어시에도 목적함수로서는 총 선로손실을 취하지 않고 발전소의 총 연료비를 취하여 이를 최소화함으로써 보다 합리적인 경제성을 도모하였다. 또 이때 필요한 제어변수에 대한 발전기 출력시 모선전압의 감도행렬의 계산은 조류 방정식의 쟈코비 행렬의 스파스한 성질을 충분히 이용하여 계산시간을 단축시킬 수 있도록 하였다. 3) 특히 무효전력 제어시에는 많은 함수형 부등식 제약조건을 즉 모선전압의 상하한 제약조건을 일정한 값으로 고정하지 않고 어떤 허용 변동폭을 주어 조건을 완화하는 퍼지 선형계획법을 적용하므로써 확정적인 제약을 갖는 일반 선형계획법을 적용할 때보다 유리한 점이 확인되었다.

  • PDF

Optimal Coordination and Penetration of Distributed Generation with Shunt FACTS Using GA/Fuzzy Rules

  • Mahdad, Belkacem;Srairi, Kamel;Bouktir, Tarek
    • Journal of Electrical Engineering and Technology
    • /
    • 제4권1호
    • /
    • pp.1-12
    • /
    • 2009
  • In recent years, integration of new distributed generation (DG) technology in distribution networks has become one of the major management concerns for professional engineers. This paper presents a dynamic methodology of optimal allocation and sizing of DG units for a given practical distribution network, so that the cost of active power can be minimized. The approach proposed is based on a combined Genetic/Fuzzy Rules. The genetic algorithm generates and optimizes combinations of distributed power generation for integration into the network in order to minimize power losses, and in second step simple fuzzy rules designs based upon practical expertise rules to control the reactive power of a multi dynamic shunt FACTS Compensator (SVC, STATCOM) in order to improve the system loadability. This proposed approach is implemented with the Matlab program and is applied to small case studies, IEEE 25-Bus and IEEE 30-Bus. The results obtained confirm the effectiveness in sizing and integration of an assigned number of DG units.