• 제목/요약/키워드: Re-tension

검색결과 80건 처리시간 0.025초

BDG 농도변화에 따른 용수의 목분 침투특성 연구 (A Study for Characteristics of Water that Penetrates Wood Flour due to Changes of Concentration of BDG)

  • 공일천;박일규;임경범;이동호
    • 한국안전학회지
    • /
    • 제28권3호
    • /
    • pp.74-79
    • /
    • 2013
  • As the feature of fire, it is hard for deep-seated fire to spread to the deeper site, and it also has danger for being re-ignited cause of recontacting with oxygen after being put off. Now it is ruled in the certification criteria of wetting agent used for extinguishing deep-seated fire that the criteria for surface tension is below 33[mN/m] in Korea. For figuring out how much water for fire-fighiting can permeate into combustibles, in this research, the permeating performance is analyzed by measuring the speed of permeating and transmission quantity released after that, by pouring solution whose surface tension is changed by adjusting concentration of surfactant BDG(Butyl Di Glycol) in column From this result, it is can be determined that transmission quantity becomes less and wet area goes wider as surface tension is lower, and it is also able to be analyzed as quantity of absorbed liquid and wet area is increased because fluid permeates into the core.

프리스트레스트 콘크리트 부재용 재긴장 정착구 하중전달시험 (Load Transfer Test for Re-tensioning Post-Tension Kit for Prestressed Concrete)

  • 허재훈;노병철
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제25권5호
    • /
    • pp.8-14
    • /
    • 2021
  • 포스트텐션 프리스트레스트 콘크리트 부재는 즉시 손실 이외에도 크리프, 건조수축 및 릴렉세이션과 같은 시간적 손실이 발생한다. 아울러 상부 슬래브 또는 포장 등의 교체 등에 의한 고정하중 변동으로 인하여 부재 상하부의 응력이 변화하게 된다. 이러한 응력의 변화는 부재의 안전성에 영향을 줄 경우가 있으며, 이 경우 프리스트레스 힘의 조절이 필요하다. 따라서 이 연구에서는 나사를 적용한 새로운 유형의 재긴장 포스트텐션 정착구를 제안하고, EAD160004 및 KCI-PS101에 규정된 하중전달시험을 통하여 하중에 대한 안전성과 변형률에 대한 안정성을 만족함을 구명하였다.

조화집중하중을 받는 무한보에서의 음향방사 (Sound Radiation From Infinite Beams Under the Action of Harmonic Point Forces)

  • 김병삼;홍동표
    • 소음진동
    • /
    • 제2권1호
    • /
    • pp.33-39
    • /
    • 1992
  • The problem of sound radiation from infinite elastic beams under the action of harmonic point forces is studied. The reaction due to fluid loading on the vibratory response of the beam is taken into account. The beam is assumed to occupy the plane z = 0 and to be axially infinite. The beam material and the elastic foundation re assumed to be lossless and Bernoulli-Euler beam theory including a tension force (T), damping coefficient (C) and stiffness of foundation $(\kappa_s)$ will be employed. The non-dimensional sound power is derived through integration of the surface intensity distribution over the entire beam. The expression for sound power is integrated numerically and the results are examined as a function of wavenumber ratio$(\gamma)$ and stiffness factor$(\Psi)$. Here, our purpose is to explain the response of sound power over a number of non-dimensional parameters describing tension, stiffness, damping and foundation stiffness.

  • PDF

굽힌 후 편 철근의 기계적 성질과 응력-변형률 모델 (Mechanical Properties and Stress-Strain Model of Re-Bars Coldly Bent and Straightened)

  • 천성철;탁소영;하태훈
    • 콘크리트학회논문집
    • /
    • 제24권2호
    • /
    • pp.195-204
    • /
    • 2012
  • 신구 콘크리트 접합부에서는 굽힌 후 편 철근을 이용한 이음이 발생한다. 철근의 굽힘과 펴는 과정에는 필연적으로 소성 변형이 발생하며, 이 과정에서 가공 경화, 바우싱거 효과, 시효 경화 현상이 발생된다. 이 연구에서는 강종, 지름, 굽힘 내면 반지름, 굽힌 후 펴기까지의 존치기간을 변수로 굽힌 후 편 철근의 인장에 대한 기계적 성질을 조사하였다. 연구 결과, 굽힌 후 편 철근은 비례한계점이 낮아지는 비선형성이 직선 철근에 비해 일찍 발생되었으며, 항복마루 없이 바로 변형경화가 발생하였다. 이것은 굽힘 가공에서 압축을 받은 부분의 바우싱거 효과에 의해 항복점이 낮아졌고, 굽힘 가공에서 인장을 받은 부분의 가공 경화에 의해 항복마루가 없어졌기 때문이다. 높은 강종일수록 항복강도의 저하가 크게 발생되었으며, SD400 철근의 항복강도는 설계기준강도보다 낮았다. 철근은 표면부의 강도가 내부보다 높기 때문에, 높은 강종일수록 굽힌 후 펴면 바우싱거 효과가 크게 발생된다. 굽힌 후 펴기까지의 존치기간이 길면 시효 경화에 의해 항복강도의 상승과 연성의 저하가 발생되었다. Ramberg-Osgood 모델을 기본 형태로 실험 자료를 회귀분석하여 항복강도와 존치기간을 고려한 굽힌 후 편 철근의 응력-변형률 관계를 구성하였다. 이 모델은 굽힌 후 편 철근이 사용된 접합부의 강성 평가에 활용될 수 있다.

Arthroscopic Partial Repair of Massive Contracted Rotator Cuff Tears

  • Kim, Sung-Jae;Kim, Young-Hwan;Chun, Yong-Min
    • Clinics in Shoulder and Elbow
    • /
    • 제17권1호
    • /
    • pp.44-47
    • /
    • 2014
  • Typically, massive rotator cuff tears have stiff and retracted tendon with poor muscle quality, in such cases orthopaedic surgeons are confronted with big challenging to restore the cuff to its native footprint. Furthermore, even with some restoration of the footprint, it is related with a high re-tear rate due to less tension free repair and less tendon coverage. In this tough circumstance, the partial repair has yielded satisfactory outcomes at relatively short follow-up by re-creating the transverse force couple of the rotator cuff. Through this partial repair, the massive rotator cuff tear can be converted to the "functional rotator cuff tear" and provide improvement in pain and functional outcomes in patient's shoulder.

칼슘, 베라파밀, 란타눔이 흰쥐 자궁근의 자발적 수축과 칼륨 경축에 미치는 효과 (Effects of $Ca^{++}$, Verapamil and $La^{+++}$ on the Spontaneous Contraction and K-contracture in the Isolated Rat Uterine Smooth Muscle)

  • 황상익
    • The Korean Journal of Physiology
    • /
    • 제18권1호
    • /
    • pp.37-50
    • /
    • 1984
  • The effects of $Ca^{++}$ and its antagonists (verapamil and $La^{+++}$) upon the spontaneous contraction and the contracture induced by 60 mM K-Tyrode solution were studied in the isolated uterine muscle. Longitudinal muscle strips were prepared from the rat uteri at estrous stage. All experiments were performed in tris-buffered Tyrode solution which was aerated with 100% $O_2$ and kept at 35^{\circ}$. The results obtained were as follows: 1) In the uterine strips contracting spontaneously, both the amplitude of peak tension and the area of contraction curve increased dose-dependently in the range of $0.5${\sim}8$ mM $Ca^{++}$. The frequency of contraction increased as the concentration of $Ca^{++}$ increased up to 2 mM, but above this concentration the frequency decreased. In $Ca^{++}-free$ media, however, contraction did not develop. In the contracture induced by 60 mM K-Tyrode solution, the developed tension increased dose-dependently as the concentration of external $Ca^{++}$ increased to 8 mM. In the absence of external $Ca^{++}$ K-contracture appeared, but it was not sustained. 2) The spontaneous contraction of rat uterus was suppressed by verapamil in proportion to an increase of its concentration and totally abolished at the concentration of $3{\times}10^{-4}\;g/l$, but the spontaneous contraction re-appeared by addition of $Ca^{++}$. The amplitude of peak tension recovered completely but the recovery of frequency was incomplete. K-contracture decreased in a dose-dependent manner after the treatment with verapamil and totally disappeared at its concentration of $3{\times}10^{-4}\;g/l$. Even in this case contracture developed again by extra $Ca^{++}$. 3) The spontaneous contractile activity was inhibited by $La^{+++}$. At the concentration of $10^{-4}$M $La^{+++}$, fibrillation appeared. In the strip inhibited by $10^{-5}M\;La^{+++}$, contractility recovered completely by extra $Ca^{++}$ while in the $10^{-4}M\;La^{+++}$ treated preparation, the rhythmic spontaneous contraction did not develop even at the concentration of 16 mM $Ca^{++}$. After the initial transient depression of contracture tension by $10^{-3}M$ of $La^{+++}$, the strip stowed considerably large size of contracture, hardly influenced by external $Ca^{++}$ or verapamil. The results obtained in this experiment suggest that in the rat uterine muscle there would be some competitive actions between $Ca^{++}$ and its antagonists. It is speculated that $Ca^{++}$ plays an important role in the conduction of excitation, and $La^{+++}$ influences upon cellular $Ca^{++}$ mobilization and re-uptake process as well as transmembrane $Ca^{++}$ transport in a K-depolarized state.

  • PDF

초고층 건축물의 포스트텐션 슬래브 시스템 적용 (The Application of Post-tensioned Slab System to Tall Buildings)

  • 정광량
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2008년도 추계 학술발표회 제20권2호
    • /
    • pp.879-882
    • /
    • 2008
  • 한국의 포스트텐션 시장은 2000년 이후부터 급성장하고 있으며 많은 엔지니어와 시공사들이 관심을 가지고 있다. 본 논문에서는 최근 한국 포스트텐션 시장의 동향과 초고층 포스트텐션 건물의 구조시스템과 시공에 대해 소개하고자 한다. 그리고 초고층 포스트텐션 건축물 설계시 고려해야할 사항에 대해서도 살펴본다. 울산에 위치한 파크폴리스는 39층 타워 2개동으로 구성되어있으며 건물 높이는 지상144m로 현재 공사가 진행중이다. 이 건물은 비부착방식 포스트텐션 시스템으로 설계되었으며 완공시 한국내 최고층 포스트텐션 건물이 될 것이다. 구조시스템은 플랫 슬랩, 외주 기둥, 코어월로 이루어져있다. 처음에는 테두리보를 가지는 일반 철근 콘크리트 구조로 설계되었지만 시공성 향상을 위해 포스트텐션 플랫슬래브로 재설계되었다.

  • PDF

Reinforced fibrous recycled aggregate concrete element subjected to uniaxial tensile loading

  • Hameed, R.;Hasnain, K.;Riaz, M. Rizwan;Khan, Qasim S.;Siddiqi, Zahid A.
    • Advances in concrete construction
    • /
    • 제9권2호
    • /
    • pp.195-205
    • /
    • 2020
  • In this study, effect of recycled aggregates and polypropylene fibers on the response of conventionally reinforced concrete element subjected to tensile loading in terms of tension stiffening and strain development was experimentally investigated. For this purpose, concrete prisms of 100 × 100 mm cross section and 500 mm length having one central deformed steel re-bar were cast using fibrous and non-fibrous Recycled Aggregate Concrete (RAC) with varying percentages of recycled aggregates (0%, 25%, 50%, 75% and 100%) and tested under uniaxial tensile load. For all fibrous RAC mixes, polypropylene fibers were used at constant dosage of 3.15 kg/㎥. Effect of recycled aggregates and fibers on the compressive strength of concrete was also explored in this study. Through studying tensile load versus global axial deformation of composite and strain development in concrete and steel, it was found that replacement of natural aggregates with recycled aggregates in concrete negatively affected the cracking load, tension stiffening and strain development, and this negative effect was observed to be increased with increasing contents of recycled aggregates in concrete. The results of this study showed that it was possible to minimize the negative effect of recycled aggregates in concrete by the addition of polypropylene fibers. Reinforced concrete element constructed using concrete containing 50% recycled aggregates and polypropylene fibers exhibited cracking behavior, tension stiffening and strain development response almost similar to that of concrete element constructed using natural aggregate concrete without fiber.

국내 현수교량의 케이블 밴드볼트 축력관리 및 검토사례 (A Case Study on Axial Forces of Cable-band Bolts in Domestic Suspension Bridge)

  • 박시현;정우영;김현우;유동우
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제22권2호
    • /
    • pp.1-7
    • /
    • 2018
  • 현수교 주 케이블은 케이블 밴드의 볼트 축력에 대한 정기적인 유지 관리가 매우 중요하다. 현수교 케이블 밴드의 볼트 축력은 시간이 경과함에 따라 케이블 소선의 크리프 현상, 볼트의 릴렉세이션, 하중 변동, 케이블 소선의 재배열 등으로 인해 축력 감소 현상이 발생하게 된다. 본 연구에서는 국내 현수 교량(SR대교)의 케이블 밴드가 시간이 경과하면서 발생하는 축력 감소 현상에 대해 그 원인 및 감소량 등에 대한 현장 측정 및 이론적 검토, 안전율 검토, 장기적인 이력 관리 등을 수행하였다. 그 결과, 케이블 밴드 볼트 축력 감소는 주 케이블 소선에 사용된 아연 도금층의 소성 변형에 크게 영향받는 것을 확인하였으며, 이에 대한 이론적 체계 및 장기 이력 관리에 대한 적용성을 확립하였다.

Aortic Composite Valve Graft의 이식시 인조혈관을 이용한 좌 관상동맥의 문합술 1례 보고 (Use of an Interposition Tube Graft for the Reattachment of Left Coronary Ostium to the Aortic Composite Valve Graft. -One Case-)

  • 김창남;최종범;최형호
    • Journal of Chest Surgery
    • /
    • 제29권6호
    • /
    • pp.646-650
    • /
    • 1996
  • Aortic composite valve graft를 이식하는 술식에서 관상동맥을 문항하는 방법에 따라 그 단점과 합병증을 가지고 있다. 종래에 주로 이용되었던 방법과 달리, composite graf 문합부의 긴장을 줄여 출혈을 최소화하고 만기에 발생할 수 있는 가성 대동맥류를 방지할 수 있는 술식을 서술하고자 한다. 저자들은 심한 대동맥판 폐쇄부전이 합병된 급성 대동맥 박리 (DeBakey Type I)를 가진 40세 남자에서 composite graft의 이식과본변형술식을시행했다 본술식에서 좌관상동맥구에 직경 10mm의 인조혈관을문합하고 그 원위부를 composite gray떼 문합하였으며 우 관상동맥 단추편은 composite graf떼 직접 문합하였다. 이 방법으로 판륜 가까이에 위치한 좌관상동맥구를 과도한 긴장없이 composite gray에 쉽게 부착할 수 있어서 술후 출혈 및 가성동맥류의 발생을 최소화할 수 있을것으로 사료된다.

  • PDF