• Title/Summary/Keyword: Ray Tube

Search Result 669, Processing Time 0.027 seconds

Effects of Soil Aggregate Stability and Wettability on Infiltration and Evaporation (토양입단(土壤粒團)의 안정성(安定性)과 친수성(親水性)이 수분침투(水分浸透) 및 증발(蒸發)에 미치는 영향(影響))

  • Jo, In-Sang;Cho, Seong-Jin;Verplanke, H.;Hartmann, R.;De Boodt, M.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.18 no.2
    • /
    • pp.121-127
    • /
    • 1985
  • This study was designed to gain practical data on the use of soil conditioners for more efficient water managements and to establish the optimum levels of structural properties for soil conditioning. A sandy loam and a silt loam soil were each treated with two different soil conditioners, hydrophobic Bitumen or hydrophilic Uresol. The perspex tube 34 cm long were packed homogeneously with air dried soil up to 2 cm below the top, then covered over 2 cm of treated or untreated aggregates. The infiltration rate into the soil columns was measured under simulated rainfall condition. The evaporation study was carried out in the wind tunnel, and the changes of soil moisture distribution of the columns following and during the evaporation were determined by a gamma ray scanner. The infiltration rate of water into the soil column was increased to 18.7-50.8% by the Uresol treatment but it was decreased to less than 25% of control by the Bitumen treatment. Evaporation was decreased to 22.0-68.1% by the Bitumen treatment and to 38.7-68.4% by the Uresol treatment. The water use efficiency of Uresol treated column was increased to more than twice as much as that of untreated soil. Aggregate stability and wetting angle were related to water infiltration and evaporation. A positive and highly significant logarismic relationship was found between the infiltration rate and stability index-wetting angle, evaporation rate and instability index-wetting angle. It was considered that the structural stability is more important than wetting angle. This is true because the structural stability is always positively correlated to water saving, however wettability is positively correlated to the infiltration, and negatively correlated to water saving during the evaporation.

  • PDF

Quality Characteristics of Milk Porridge (Tarakjuk) Sterilized with Radiation Technology (방사선 조사 기술을 이용하여 제조한 멸균 우유죽(타락죽)의 품질 특성)

  • Han, In-Jun;Park, Jae-Nam;Park, Jin-Gyu;Song, Beom-Seok;Lee, Ju-Woon;Kim, Jae-Hun;Ryu, Hong-Soo;Park, Jeong-Ro;Chun, Soon-Sil
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.40 no.6
    • /
    • pp.885-891
    • /
    • 2011
  • We conducted this study to determine the optimum dose of gamma irradiation needed for the sterilization of milk porridge for patients. Milk porridge, known as Tarakjuk, was irradiated with gamma ray at doses of 0, 1, 3, 5, 7, or 10 kGy. The microbial contamination, $D_{10}$ values of isolated microbe spores, color, and viscosity were measured during storage at $35^{\circ}C$. The initial count of total aerobic bacteria was 2.60 log CFU/g in the non-irradiated milk porridge, but coliforms, spore-forming bacteria, yeast, and molds were not detected. The total counts of aerobic and spore-forming bacteria in the non-irradiated and 1 kGy irradiated milk porridge increased with storage period. These microbes were not detected in the milk porridge irradiated with 10 kGy. The $D_{10}$ values of isolated spores from milk porridge were 2.71 kGy (in milk porridge) and 2.21 kGy (in saline solution). All CIE color increased with gamma irradiation, but the sensory value of color did not significantly change. The viscosity of the milk porridge decreased with gamma irradiation and storage period, and the decrease in viscosity with storage period became smaller as the radiation doses increased. Sensory evaluation scores of the milk porridge were above normal (4.0) when irradiated with less than 5 kGy. These results indicate that gamma irradiation could be beneficial for preparing food with higher nutrient density and lower viscosity, especially for gastric tube-fed patients.

Research of z-axis geometric dose efficiency in multi-detector computed tomography (MDCT 장치의 z-축 기하학적 선량효율에 관한 연구)

  • Kim, You-Hyun;Kim, Moon-Chan
    • Journal of radiological science and technology
    • /
    • v.29 no.3
    • /
    • pp.167-175
    • /
    • 2006
  • With the recent prevalence of helical CT and multi-slice CT, which deliver higher radiation dose than conventional CT due to overbeaming effect in X-ray exposure and interpolation technique in image reconstruction. Although multi-detector and helical CT scanner provide a variety of opportunities for patient dose reduction, the potential risk for high radiation levels in CT examination can't be overemphasized in spite of acquiring more diagnostic information. So much more concerns is necessary about dose characteristics of CT scanner, especially dose efficient design as well as dose modulation software, because dose efficiency built into the scanner's design is probably the most important aspect of successful low dose clinical performance. This study was conducted to evaluate z-axis geometric dose efficiency in single detector CT and each level multi-detector CT, as well as to compare z-axis dose efficiency with change of technical scan parameters such as focal spot size of tube, beam collimation, detector combination, scan mode, pitch size, slice width and interval. The results obtained were as follows ; 1. SDCT was most highest and 4 MDCT was most lowest in z-axis geometric dose efficiency among SDCT, 4, 8, 16, 64 slice MDCT made by GE manufacture. 2. Small focal spot was 0.67-13.62% higher than large focal spot in z-axis geometric dose efficiency at MDCT. 3. Large beam collimation was 3.13-51.52% higher than small beam collimation in z-axis geometric dose efficiency at MDCT. 4. Z-axis geometric dose efficiency was same at 4 slice MDCT in all condition and 8 slice MDCT of large beam collimation with change of detector combination, but was changed irregularly at 8 slice MDCT of small beam collimation and 16 slice MDCT in all condition with change of detector combination. 5. There was no significant difference for z-axis geometric dose efficiency between conventional scan and helical scan, and with change of pitch factor, as well as change of slice width or interval for image reconstruction. As a conclusion, for reduction of patient radiation dose delivered from CT examination we are particularly concerned with dose efficiency of equipment and have to select proper scanning parameters which increase z-axis geometric dose efficiency within the range of preserving optimum clinical information in MDCT examination.

  • PDF

Microbial Growth in Dried Fishes During Preservation (건어물 저장 중 미생물 증식상태에 관한 연구)

  • 이현자;김종군;이수정;조한옥
    • Journal of Food Hygiene and Safety
    • /
    • v.8 no.3
    • /
    • pp.135-140
    • /
    • 1993
  • Dried fishes such as dried pollack, dried sliced squid, dried white bait, dried anchoy) and dried cod used to cook Korean traditional foods were airpacked in polyethylene tube and irradiated with 7 kGy of gamma-ray source. The effect of gamma irradiation on microbial growth in dried fishes was investigated during storage at ambient temperature for 12 months. The total aerobic bacteria in the control group were contaminated by $3.9{\times}10^{3}\;cells/g$ in dried pollack, $5.6{\times}10^{5}\;cells/g$ in dried sliced squid, $1.2{\times}10^{5}\;cells/g$ in dried white bait, $1.2{\times}10^{4}\;cells/g$ in dried anchovy and $1.2{\times}10^{4}\;cells/g$ in dried cod and 7 kGy irradiation could eliminate the bacteria and also reduce aerobic bacterial load to 1~3 log cycle and no apparent growth of microorganisms occurred during storage. Molds in the control group were contaminated by $4.0{\times}10^{2}\;cells/g$ in dried pollack, $$1.3{\times}10^{2}\;cells/g$ in dried sliced squid, $2.5{\times}10^{2}\;cells/g$ in dried white bait, 90 cells/g in dried anchovy and $2.0{\times}10^{2}\;cells/g$ in dried cod, respectively. 7 kGy irradiation could sterilize the molds and the growth of molds of nonirradiated samples were slightly decreased during storage. Yeasts in the control group were contaminated by $1.4{\times}10^{3}\;cells/g$ in dried poUack, 75 cells/g in dried sliced squid, $1.1{\times}10^{3}\;cells/g$ in dried white bait, 50 cells/g in dried anchovy, $1.6{\times}10^{2}\;cells/g$ in dried cod, respectively and irradiation could sterilize the yeasts and growth of yeasts was slightly decreased in dried pollack and dried white bait but increased in order of dried anchovy, dried cod and dried sliced squid. Coliforms in all sample were sterilized by irradiation and its growth was decreased during storage except dried anchovy.

  • PDF

Actual Condition of Quality Control of X-ray Imaging System in Primary Care Institution: focused on Gwangju Metropolitan City (1차 의료기관의 엑스선 발생장치 정도관리에 관한 현황조사:광주광역시 지역을 중심으로)

  • Dong, Kyung-Rae;Lee, Seun-Joo;Kweon, Dae-Cheol;Goo, Eun-Hoe;Jung, Jae-Eun;Lee, Kyu-Su
    • Journal of Radiation Protection and Research
    • /
    • v.35 no.1
    • /
    • pp.34-42
    • /
    • 2010
  • With the expanded use of radiation in modern medical practices, the most important issue in regards to efforts to reduce individual exposure dose is quality assurance. Therefore in order to study the present condition of quality assurance, the Gwangju Metropolitan City area was divided into five districts each containing ten hospitals. Four experiments were conducted: a reproducibility experiment for kVp, mA, and examination time (sec) intensity of illumination; half-value layer (HVL) measurement; and beam perpendicularity test matching experiment. The tube voltage reproducibility experiment for all fifty hospitals resulted in a 95.33% passing rate and mA and examination time both resulted in a 77.0% passing rate. The passing rate for intensity of illumination was 86.0% and 52.0% for HVL, which was the lowest passing rate of all four factors. For the beam perpendicularity test matching experiment, generally the central flux is matched to within $1.5^{\circ}$. Of all fifty hospitals 30.0% were beyond $3^{\circ}$. The results of the survey showed that 58% responded that they knew about quality assurance cycle. All fifty respondents stated that they have not received any training in regards to quality assurance at their current place of employment. Although quality assurance is making relative progress, the most urgent issue is awareness of the importance of quality assurance. Therefore, the implementation of professional training focusing on safety management and accurate quality assurance of radiation will reduce the exposure to radiation for radiologists and patients and higher quality imaging using less dosage will also be possible.

Variations in Morphological and Geochemical Characteristics in Manganese Nodules from the East Siberian Arctic Shelf with Varying Water Depths (동시베리아해 대륙붕에서 산출되는 망가니즈단괴의 수심에 따른 형태학적·지화학적 특성 변화)

  • Hyo-Jin Koo;Hyen-Goo Cho;Sangmi Lee;Gi-Teak Lim;Hyo-Im Kim
    • Economic and Environmental Geology
    • /
    • v.56 no.1
    • /
    • pp.1-11
    • /
    • 2023
  • In this study, we explore the morphological and geochemical characteristics for 440 manganese nodules collected from two different water depths [ARA12B-St52 (150 m, n = 239) and ARA12B-St58i (73 m, n = 201)] on the continental shelf of the East Siberian Sea from the ARA12B expedition in 2021. We also discussed the variations in the characteristics of manganese nodules with varying water depths in the Arctic Sea. The sizes of the nodules are generally greater than 3 cm at both sites. However, there is an obvious difference in the morphology with water depths. For the nodules collected at 150 m, brown-black colored tabular, tube, and ellipsoidal shapes with a rough surface texture are dominant. On the other hand, yellow-brown tabular shapes with a smooth surface texture are common for the nodules collected at 73 m. Furthermore, the slope of trend line between size and weight is significantly different at both sites: particularly, the slopes of nodules at 150 and 73 m are 1.60 and 0.84, respectively. This indicates the difference in the internal structure, porosity, and constituting elements between both nodules. Micro X-ray Flourescence (µ-XRF) results clearly demonstrate that the internal textures and chemical compositions are different with water depths. The nodules at 150 m are composed of a thick Mn-layer and a thin Fe-layer centered on the nucleus, while the nodules at 73 m are alternately grown with thin Mn- and Fe- layers around the nucleus. The average chemical compositions obtained by µ-XRF are 40.6 wt% Mn, 5.2 wt% Fe, and 7.9 Mn/Fe ratio at 150 m, and 10.3 wt% Mn, 19.0 wt% Fe, and 0.6 Mn/Fe ratio at 73 m. The chemical compositions of the nodules at 150 m are similar to those of nodules from the Peru Basin in the Pacific Ocean, while the compositions of the nodules at 73 m are similar to those of nodules from the Cook Islands or the Baltic Sea. The observed morphological and geochemical characteristics of the nodules show a clear difference at the two sites, which indicates that the aqueous conditions and formation processes of the nodules in the Arctic Sea vary with the water depths.

Characteristics of Blood Mixed Cement in Percutaneous Vertebroplasty (경피적 척추 성형술에서 혈액 혼합 시멘트의 특성)

  • Seo, Jin-Hyeok;Woo, Young-Ha;Jeong, Ju-Seon;Kim, Do-Hun;Kim, Ok-Gul;Lee, Sang-Wook;Park, Chan-Ho
    • Journal of the Korean Orthopaedic Association
    • /
    • v.54 no.5
    • /
    • pp.435-439
    • /
    • 2019
  • Purpose: This study evaluated the efficacy of blood mixed cement for osteoporotic vertebral compression fractures in reducing the complications of percutaneous vertebroplasty using conventional cement. Materials and Methods: This study was performed retrospectively in 80 patients, from January 2016 to January 2017. Porous cement was formed by mixing 2, 4, and 6 ml of blood with 20 g of cement used previously. A tube with a diameter and length of 2.8 mm and 215 mm, respectively, was used and the polymerization temperature, setting time, and optimal passing-time were measured and compared with those using only conventional cement. Radiologically, the results were evaluated and compared. Results: The polymerization temperature was 70.3℃, 55.3℃, 52.7℃, and 45.5℃ in the conventional cement (R), 2 ml (B2), 4 ml (B4), and 6 ml (B6), respectively, and the corresponding setting time decreased from 960 seconds (R) to 558 seconds (B2), 533 seconds (B4), and 500 seconds (B6). The optimal passing-time was 45 seconds (B2), 60 seconds (B4), and 78 seconds (B6) at 73 seconds (R), respectively and as the amount of blood increased, it was similar to the cement passing-time. The radiological results showed that the height restoration rates and the vertebral subsidence rates similar among the groups. Two cases of adjacent vertebral compression fractures in the R group and one in the B2 and B4 groups were encountered, and the leakage rate of the cement was approximately two times higher than that in the conventional cement group. Conclusion: In conventional percutaneous vertebroplasty, the procedure of using autologous blood with cement decreased the polymerization temperature, reduced the setting time, and the incidence of cement leakage was low. These properties may contribute to more favorable mechanical properties that can reduce the complications compared to conventional cements alone.

One-stop Evaluation Protocol of Ischemic Heart Disease: Myocardial Fusion PET Study (허혈성 심장 질환의 One-stop Evaluation Protocol: Myocardial Fusion PET Study)

  • Kim, Kyong-Mok;Lee, Byung-Wook;Lee, Dong-Wook;Kim, Jeong-Su;Jang, Yeong-Do;Bang, Chan-Seok;Baek, Jong-Hun;Lee, In-Su
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.33-37
    • /
    • 2010
  • Purpose: In the early stage of using PET/CT, it was used to damper revision but recently shows that CT with MDCT is commonly used and works well for an anatomical diagnosis. This hospital makes the accuracy and convenience more higher in the diagnosis and evaluate of coronary heart disease through concurrently running myocardial perfusion SPECT examination, myocardial PET examination with FDG, and CT coronary artery CT angiography(coronary CTA) used PET/CT with 64-slice. This report shows protocol and image based on results from about 400 coronary heart disease examinations since having 64 channels PET/CT in July 2007. Materials and Methods: An Equipment for this examination is 64-slice CT and Discovery VCT (DVCT) that is consisted of PET with BGO ($Bi_4Ge_3O_{12}$) scintillation crystal by GE health care. First myocardial perfusion SPECT with pharmacologic stress test to reduce waiting time of a patient and get a quick diagnosis and evaluation, and right after it, myocardial FDG PET examination and coronary CTA run without a break. One-stop evaluation protocol of ischemic heart disease is as follows. 1)Myocardial perfusion SPECT with pharmacologic stress: A patient is injected with $^{99m}Tc$-MIBI 10 mCi and does not have any fatty food for myocardial PET examination and drink natural water with ursodeoxcholic acid 100 mg and we get SPECT image in an hour. 2)Myocardial FDG PET: To reduce blood fatty content and to increase uptake of FDG, we used creative oral glucose load using insulin and Acipimox to according to blood acid content. A patient is injected with $^{18}F$-FDG 5 mCi for reduction of his radiation exposure and we get a gated image an hour later and get delay image when we need. 3) Coronary CTA: The most important point is to control heart rate and to get cooperation of patient's breath. In order to reduce a heart rate of him or her below 65 beats, let him or her take beta blocker 50 mg ~ 200 mg after a consultation with a doctor about it and have breath-practices then have the examination. Right before the examination, we spray isosorbide dinitrate 3 to 5 times to lower tension of bessel wall and to extension a blood wall of a patient. It makes to get better the shape of an anatomy. At filming, a patient is injected CT contrast with high pressure and have enough practices before the examination in order to have no problem. For reduction of his radiation exposure, we have to do ECG-triggered X-ray tube modulation exposure. Results: We evaluate coronary artery stenosis through coronary CTA and study correlation (culprit vessel check) of a decline between stenosis and perfusion from the myocardial perfusion SPECT with pharmacologic stress, coronary CTA, and can check viability of infarction or hibernating myocardium by FDG PET. Conclusion: The examination makes us to set up a direction of remedy (drug treatment, PCI, CABG) because we can estimate of effect from remedy, lesion site and severity. In addition, we have an advantage that it takes just 3 hours and one-stop in that all of process of examinations run in succession and at the same time. Therefore it shows that the method is useful in one stop evaluation of ischemic heart disease.

  • PDF

Facters Affecting Recurrence after Video-assisted Thoracic Surgery for the Treatment of Spontaneous Pneumothotax (자연기흉에 대한 비디오흉강경수술후 재발에 영향을 미치는 요인들)

  • 이송암;김광택;이일현;백만종;최영호;이인성;김형묵;김학제
    • Journal of Chest Surgery
    • /
    • v.32 no.5
    • /
    • pp.448-455
    • /
    • 1999
  • Background: Recent developments in techniques of video-assisted thoracic surgery(VATS) and endoscopic equipment has expanded the application of video-assisted surgical procedures in the field of thoracic surgery. Especially, it will probably become the treatment of choice of spontaneous pneumothorax(SP). There is, however, a high recurrence rate, high cost, and paucity of long-term results. We report the results of postoperative follow-up and analyze perioperative parameters affected to recurrence, retrospectively. Material and Method: From march 1992 to march 1997, 276 patients with spontaneous pneumothorax underwent 292 VATS procedures. Conversion to open thoracotomy was necessitated in eight patients, and this patients excluded from the study. Result: The sex distribution was 249 males and 31 females. The mean age was 28.1 12.2 years(range, 15 to 69 years). Primary SP was 237cases(83.5%) and secondary SP was 47cases(16.5%). The major underlying lung diseases associated with secondary SP were tuberculosis 27cases(57.4%) and emphysema 8cases (38.3%). Operative indications included Ipsilateral recurrence 123(43.9%), persistent air-leak 53(18.9%), x-ray visible bleb 40(14.3%), tension 30(10.7%), contralateral recurrence 21(7.5%), uncomplicated first episode 8(2.9%), bilateral 3(1.1%), complicated episode 2(0.7%). Blebs were visualized in 247cases(87%) and 244cases(85.9%) performed stapled blebectomy. Early postoperative complications occurred in 33 cases(11.6%): 16 prolonged air-leak more than 5 days(four of them were required a second operation and found missed blebs); 5 bleeding; 5 empyema; 2 atelectasis; 1 wound infection. No deaths occured. The mean operative time was 52.8 23.1 minutes(range, 20 to 165 minutes). The mean d ration of chest tube drainage was 5.0 4.5 days(range, 2 to 37 days). The mean duration ofhospital stay was 8.2 5.5 days (range, 3 to 43days). At a mean follow-up 22.3 18.4 months(range, 1 to 65 months), 12 patients(4.2%) were lost to follow-up. There were 24 recurrences and seven patients underwent second operation and 6 patients(85.7%) were found the missed blebs. 12 perioperative parameters(age, sex, site, underlying disease, extent of collapse, operative indication, size of bleb, number of bleb, location of bleb, bleb management, pleural procedure, prolonged postoperative air-leak) were analyzed statistically to identify significant predictors of recurrence. The significant predictors of recurrence was the underlying disease[17.0%(8/47): 6.8%(16/237), p=0.038], prolonged postoperative air-leakage[37.5%(6/16): 6.7%(18/268), p=0.001], and pleural procedure [11.4%(19/167): 4.3%(5/117), p=0.034]. Blebectomy has less recurrence rate then non-blebectomy [8.2%(20/244) : 10.0%(4/40), p>0. 5]. However, this difference was not statistically significant(p=0.758). Conclusion: We conclude that it is important that we shoud careful finding of bleb during VATS due to reducing of recurrnece, and cases of no bleb identified and secondary spontaneous pneumothorax were indicated of pleurodectomy. VATS is a valid alternative to open procedure for the treatment of spontaneous pneumothorax with less pain, shorter hospital stay, more rapid return to work, high patient acceptance, less scar and exellent cosmetics. But, there is high recurrence rate and high cost, and than it is necessary to evaluate of long-term results for recurrence and to observate carefully during VATS.

  • PDF