• Title/Summary/Keyword: Ray Tube

Search Result 666, Processing Time 0.027 seconds

A Study on the Phenomena of Renal Stone in Simple Radiography (X선 단순촬영에 있어서 신장결석의 출현에 관한 검토)

  • Yoo, Jang-Soo;Song, Jae-Kwan;Huh, Joon
    • Journal of radiological science and technology
    • /
    • v.12 no.1
    • /
    • pp.25-29
    • /
    • 1989
  • This paper investigated on influence on the distinguishability of renal stone in the accordance with thickness of object, x-ray tube voltage and base density. In the relationship between object and renal stone shadow, object and tube voltage, the obtained results can be summarized as the following. 1. When thickness of object was thin, the distinguishability increased in base density $2.0{\sim}2.5$, but for adults was best shown in base density 1.5. 2. In the relationship between object and tube voltage, the distinguishability increased at lower tube voltages ($50{\sim}60\;kVp$), using grid. As mentioned above, it was thought that this method was very effective in describing the phenomena of renal stone in film density 1.5, tube voltages 60 kVp.

  • PDF

Evaluations of the Space Dose and Dose Reductions in Patients and Practitioners by Using the C-arm X-ray Tube Shielding Devices Developed in Our Laboratory

  • Kim, Jae Seok;Kim, Sung Ho;Lee, Bu Hyung;Kwon, Soo Il;Jung, Hai Jo;Hoe, Seong Wook;Son, Jin Hyun;Kang, Byeong Sam
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.241-249
    • /
    • 2016
  • The present study used a digital angiography x-ray device to measure the space dose and exposure dose of patients and practitioners using x-ray tube shielding devices developed in our laboratory. The intent of the study was to reduce the space dose within the test room, and to reduce the exposure dose of patients and practitioners. The patient and practitioner exposure doses were measured in five configurations in a human body model. The glass dosimeter was placed on the eye lenses, thyroid glands, left shoulder, right shoulder, and gonads. The beam was collimated at full size and at a 48% reduction for a comparative analysis of the measurements. The space dose was measured with an ion chamber at distances of 50 cm, 100 cm, and 150 cm from the x-ray tube under the following conditions: no shielding device; a shielding device made of 3-mm-thick lead (Pb) [Pb 3 mm shield], and a shielding device made of 3-mm-thick Pb (outside) and 3-mm-thick aluminum (Al) (inside) [Pb 3 mm+Al 3 mm shield]. The absorbed dose was the lowest when the 3-mm-thick Pb+3-mm-thick Al shield was used. For measurements made with collimated beams with a 48% reduction, the dose was the lowest at $154{\mu}Gy$ when the 3-mm-thick Pb+3-mm-thick Al shield was used, and was $9{\mu}Gy$ lower than the measurements made with no shielding device. If the space dose can be reduced by 20% in all situations where the C-arm is employed by using the x-ray tube shielding devices developed in our laboratory, this is expected to play an important role in reducing the annual exposure dose for patients, practitioners, and assistants.

Development of an electron source using carbon nanotube field emittes for a high-brightness X-ray tube (탄소나노튜브를 이용한 고휘도 X-선원용 전자빔원 개발)

  • Kim, Seon-Kyu;Heo, Sung-Hwan;Cho, Sung-Oh
    • Journal of the Korean Vacuum Society
    • /
    • v.14 no.4
    • /
    • pp.252-257
    • /
    • 2005
  • A high-brightness electron beam source for a microfocus X-ray tube has been fabricated using a carbon-nanotube (CNT) field emitter. The electron source consists of cathode that includes a CNT field emitter, a beam-extracting grid, and an anode that accelerates that electron beam. The microfocus X-ray tube requires an electron beam with the diameter of less than 5 $\mu$m and beam current of higher than 30 $\mu$A at the position of the X-ray target. To satisfy the requirements, the geometries of the field emitter tips and the electrodes of the gun was optimized by calculating the electron trajectories and beam spatial profile with EGUN code. The CNT tips were fabricated with successive steps: a tungsten wire with the diameter of 200 $\mu$m was chemically etched and was subsequently coated with CNTs by chemical vapor deposition. The experiments of electron emission at the fabricated CNT tips were performed. The design characteristics and basic experimental results of the electron source are reported.

Optimum Design and Tolerance Analysis of Multilayer Mirror for Obtaining Characteristic X-ray of 17.5 keV (몰리브덴(Mo) 특성방사선 획득을 위한 다층박막 거울의 최적 설계 및 공차 분석)

  • Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.3 no.4
    • /
    • pp.23-28
    • /
    • 2009
  • Monochromatic X-ray can make a medical image of high contrast under a low radiation dose and can be easily generated by combining an X-ray tube and a multilayer mirror. A W/C multilayer mirror was optimally designed for a characteristic X-ray generated from a X-ray tube with Mo target. The d-spacing and the thickness ratio in design parameters were determined under the maximum-reflectivity condition. Tolerances for deposition and alignment of the W/C multilayer mirror were calculated. Within a deposition tolerance of 0.2nm and a alignment tolerance of ${\pm}0.01^{\circ}$, 85% of the theoretical peak reflectivity could be achieved. A multilayer mirror can be widely used for making medical images because of generating high fluence monochromatic X-ray.

  • PDF

Development of a Small Animal CT using a Linear Detector Array and Small-Scale Slip Rings

  • An Ung Hwan;Chun In Kon;Lee Sang Chul;Cho Min Hyoung;Lee Soo Yeol
    • Journal of Biomedical Engineering Research
    • /
    • v.26 no.1
    • /
    • pp.43-47
    • /
    • 2005
  • We have developed a small bore x-ray CT for small animal imaging with a linear x-ray detector array and small-scale slip rings. The linear x-ray detector array consists of 1024 elements of 400□m×400□m with a gadolinium oxysulfide (GOS) scintillator on top of them. To avoid use of expensive large diameter slip rings for projection data transmission from the X­ray detector to the image reconstruction system, we used the wireless LAN technology. The projection data are temporally stored in the data acquisition system residing on the rotating gantry during the scan and they are transmitted to the image reconstruction system after the scan. With the wireless LAN technology, we only needed to use small-scale slip rings to deliver the AC electric power to the X-ray generator and the power supply on the rotating gantry. The performances of the small animal CT system, such as SNR, contrast, and spatial resolution, have been evaluated through experiments using various phantoms. It has been experimentally found that the SNR is almost linearly proportional to the tube current and tube voltage, and the minimum resolvable contrast is less than 30 CT numbers at 40kVp/3.0㎃. The spatial resolution of the small animal CT system has been found to be about 0.9Ip/㎜. Postmortem images of a piglet is also presented.

A ray-based approach to scattering from inhomogeneous dielectric objects (전파경로 투적에 의한 비균질 유전체의 전자파 산란)

  • Kim, Hyeongdong
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.2
    • /
    • pp.31-37
    • /
    • 1995
  • A ray-based approach is developed to calculate the scattering from inhomogeneous dielectric objects. This approach is a natural extension of the "shooting and bouncing ray(SBR)" technique developed earlier for calculating the radar cross section of cavity structures and complex targets. In this formulation, a dense grid of rays representing the incident field is shot toward the scatterer. The curved trajectory, amplitude, phase and polarization of the ray fields inside the inhomogeneous object are computed numerically based on the laws of geometrical optics. The contributions of the exting rays to the exterior scattered field are then calculated by using the equivalence principle in conjunction with " a ray-tube integration" scheme. The ray-based approach is applied for the effect of an arcjet plasma plume on satellite reflector performance and backscattering from inhomogeneous objects.

  • PDF

THE CHARACTERISTICS OF OUTPUT FOR INVERTER TYPE X-RAY GENERATOR

  • Lim, Hong-Woo;Han, Euam-Yong;Baek, Hyung-Lae;Lee, Seong-Kil
    • Proceedings of the KIPE Conference
    • /
    • 1998.10a
    • /
    • pp.431-435
    • /
    • 1998
  • This paper deals with the output characteristics of resonant PWM inverter type X-ray generators connected to different DC power units i.e. a single phase full bridge rectifier, a three phase full bridge rectifier and a power storage unit(PSU). The quality of X-ray beam depend on the pulsation waveforms of DC voltage supplied to the X-ray tulbe. In a X-ray generator, the waveforme of DC output voltage can be affected from hramonic distortion of DC input power. When a tube voltage waveform is distorded, the property of X-ray beam such as reproducibility, direcibility and doesage can be reduced. Therefore, we compared DC output waveforms and doesages with three thpe of DC power units and show the experimental results in this paper

  • PDF

Development and Usefulness Evaluation of Simulator for Educational Radiation Generator (방사선발생장치 교육을 위한 시뮬레이터의 개발과 유용성 평가)

  • Seo, Jeong-Min
    • Journal of radiological science and technology
    • /
    • v.44 no.6
    • /
    • pp.591-597
    • /
    • 2021
  • In the present study, we developed virtual reality education contents for radiation generator on radiation education field. The radiation generator was divided by module and even the X-ray exposure part was manufactured in detail for designing 3D models. The mechanical details of the X-ray exposure part, the function of adjusting field size of the X-ray, the function of moving the exposure part, and the demonstrating the principle of the X-ray tube were applied. For developing VR contents, the Unreal Engine was used. To evaluate the usefulness of virtual reality content, we used t-test by SPSS. The group used the simulator showed significantly higher levels of understanding of X-ray generation, X-ray irradiation unit composition, irradiation field size adjustment, irradiation unit position adjustment, and overall composition and function. We believe that this VR contents will be used well with radiation safe environment.

Study on 3D Printer Producing of Assistive Devices for Vertical Incidence of Law Method (Law법 수직입사를 위한 보조기구의 3D 프린터 제작 연구)

  • Kim, Sang-Hyun
    • Journal of radiological science and technology
    • /
    • v.43 no.6
    • /
    • pp.489-494
    • /
    • 2020
  • The Law method is observing the temporal bone. There are two types of methods: the double angle method, which manipulates the center ray angle of the tube twice, and the single angle method, which manipulates once. The purpose is to increase the reproducibility of the image by making vertical incidence by making an assistive device using a 3D printer. Two assistive devices with a wedge-shaped 8.5 × 10 × 2.3 cm, an inclined surface of 7.5 cm, and an inclination angle of 15° were fabricated. Assistive devices can be combined with each other in the form of grooves, and PLA (Poly Lactic Acid) is used as a material. In the first experiment, 10 examiners operated the tube 15° in the caudad direction and 15° in the anterior direction, and measured it with a protractor to conduct a reproducibility experiment. Second, two examiners acquired vertically incidence images using the existing law method and assistive devices, and measured the distance between each measurement point to evaluate the reproducibility. The tube center ray angle reproducibility experiment was not statistically significant, but the angle difference was up to 9° between examiners. The reproducibility experiment of radiographic images was not statistically significant with the conventional method, and the method using an assistive device was statistically significant. Therefore, regardless of skill level, an image capable of securing reproducibility, which is the advantage of vertical incidence, could be obtained.

Optical analysis of low concentration evacuated tube solar collector

  • Teles, Mavd R.;Carvalho, Raquel;Ismail, Kamal A.R.
    • Advances in Energy Research
    • /
    • v.5 no.3
    • /
    • pp.227-237
    • /
    • 2017
  • The continuous increase of emission rates of green house gases and the effects on global warming added a new dimension to the problem of substituting the petroleum and its derivatives by environment friendly and sustainable energy sources for the world. Solar and wind energy appear at the top of the list of renewable of high potential, widely available, of dominated technology and well accepted. Brazil is one of the few countries in the world that receives number hours of sunshine exceeding 3,000 hours per year with a daily average of 4.5 to 6 kWh. However, this potential is largely unexplored and poorly tapped. The number of renewable systems implanted in Brazil has grown in recent years, but still insignificant when compared, for example, with Germany and Spain among others. This paper presents the results of an optical study on small concentration solar collector with evacuated tube enveloping the absorber and internal reflective surface fixed on the bottom part of the evacuated tube. The designed collector has a 2D geometrical concentration ratio between 2.455 and 4.91. The orientation of the solar collector, the ratio of the radius of the receiver to the radius of the absorber, the incidence angle for each period of the year, the collector inclination angle, the aperture angle of the reflective surface, concentration and optical efficiency were determined. The ray traces and flux distribution on the absorber of the evacuated tube solar collector were determined by using the program Ray Optics Simulation. The optical efficiency varies during the year according to the solar declination. For the periods were the solar declination is close to zero the efficiencies are maximum, and the variation during the day is around 25.88% and 99.9%. For the periods were the solar declination is maximum the efficiencies are minimum, and the variation during the day is around 23.78% and 91.79%.