• Title/Summary/Keyword: Ray Method

Search Result 5,505, Processing Time 0.03 seconds

Evaluation of Effectiveness of New Design Lead Apron during Pregnant X-ray Chest P-A (임산부 흉부 촬영중 사용할 새로 디자인된 납치마의 효율성 평가)

  • Kim, Hyeonggyun;Kwon, Soonmu;Jung, Hongmoon
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.441-445
    • /
    • 2012
  • X-ray Chest P-A is very important and basic diagnosis examination for pregnant women. For a pregnancy period pregnant women should be treated very carefully not to be exposed to any radiation which might cause harmful damage to women and babies as well. Lead apron is one of the effective methods to protect pregnant women from the X-ray radiation. However, it is difficult to obtain the accurate position of pregnant women during X-ray Chest P-A since conventional lead apron method forces pregnant women to hold the apron by themselves only to make pregnant women very uncomfortable and hard to maintain accurate position during radiation. As a consequence, it is common to get low quality images of X-ray Chest P-A due to the overlap of apex of lung and scapular. In order to fix this problem, we made new design lead apron that allowed pregnant women to be more comfortable to maintain accurate position during X-ray Chest P-A position. Finally, with this new design lead apron, it was possible to get the best optimized images of X-ray Chest P-A of pregnant women by minimizing overlapping apex of lung and scapular.

Detection of Hidden Proximal Caries using Q-ray view in Primary Molars (Q-ray view를 이용한 유구치의 숨은 인접면 우식증 탐지)

  • Jeong, Younwook;Lee, Hyoseol;Choi, Hyungjun;Lee, Jaeho;Choi, Byungjai;Kim, Seongoh
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.42 no.3
    • /
    • pp.209-217
    • /
    • 2015
  • The purpose of this study was to evaluate the ability of Q-ray view (All-in-one Bio, Seoul, Korea) in detection of proximal caries in primary molars with sound marginal ridges. Thirty two children aged 3-9 years (average $5.6{\pm}1.3$ years old) were chosen, and two examiners evaluated 100 proximal surfaces of primary molars with sound marginal ridges. The teeth were examined with; (a) visual examination, (b) Q-ray view, (c) DIAGNOdent (KaVo, Biberach, Germany) and (d) digital periapical radiography. Kappa statistic was used to assess the agreement between each examination method and the degree of caries progression. The kappa values for enamel caries were 0.15 (visual examination), 0.10 (Q-ray view), 0.25 (DIAGNOdent) and 0.68 (digital periapical radiography). The kappa values for dentinal caries were 0.34 (visual examination), 0.56 (Q-ray view), 0.44 (DIAGNOdent) and 0.70 (digital periapical radiography). Although Q-ray view showed low diagnostic ability in detection of enamel caries, it was effective in detection of hidden proximal caries extended into dentin. Q-ray view would be a useful and simple device which could aid pediatric dentists in detection of hidden proximal caries in primary molars especially when examining uncooperative children or disabled persons.

Identification of natural colored diamonds using UV fluorescent and X-ray Lang images (UV 형광과 X-선 Lang 표면이미지를 이용한 천연유색다이아몬드의 감별 연구)

  • Kim, Jun-Hwan;Ha, Jun-Seok;Kim, Ki-Hoon;Song, Oh-Sung
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3540-3545
    • /
    • 2009
  • Due to recent development of high temperature high pressure(HTHP) diamond synthetic and treatment technology, we need to identify the natural diamonds fast, reliable, and economically. We proposed using new method of UV fluorescence and X-ray Lang topography imaging for distinguishing one synthetic diamond from four natural colored diamonds. We observe unique local stress field uneven image in synthetic diamond using UV fluorescence and Lang topography characterization, while uniform images in natural diamonds. Especially, X-ray Lang method offered the better identification power with better high resolution on stress field images.

Insight Into the Crystallinity of Chinese Ancient Silk by Synchrotron Radiation-Based and Conventional X-ray Diffraction Methods

  • Gong, Decai;Zhang, Xiaoning;Gong, Yuxuan
    • Journal of Conservation Science
    • /
    • v.36 no.1
    • /
    • pp.1-14
    • /
    • 2020
  • This study investigates the crystallinity distribution of ancient silk. Owing to the inherent multi-hierarchical structure of silk protein and the complicated structural changes that occur due to various burial environments, it is challenging but worthwhile to study ancient silk ageing behavior, which is based on the fact that ageing begins with a single fiber and then spreads to a whole fabric. Crystallinity was one of the most effective indicators found to reveal the ageing status of silk. Therefore, a synchrotron radiation-based X-ray diffraction(SR-XRD) method was employed to study the crystallinity distribution of single fibers of ancient silk unearthed from seven archaeological sites in China from historical periods including the warring states, Han dynasty, Song dynasty, and Ming dynasty. In comparison, the conventional X-ray diffraction method, which uses large amounts of samples, was also performed to determine the integral crystallinity of ancient silk. Thermal stability experiments by thermogravimetry(TG) as well as morphology observations by scanning electron microscopy(SEM) and optical microscopy(OM) all confirmed the deterioration of ancient silk. Moreover, the ageing mechanism of ancient silk was proposed with the assistance of an artificial ageing study. The results confirmed the effectiveness of SR-XRD as an ageing indicator, revealing the crystallinity distribution. This research could provide motivation to determine the deterioration status of ancient silk, and would also aid in explaining the fragility of ancient silk due to ageing.

High Frequency Vibration Analysis of Arrayed Panel Structures Using a Ray Tracing Method (레이 추적 기법을 이용한 연속 평판 구조물의 고주파수 진동해석)

  • 채기상;이정권;전재진
    • The Journal of the Acoustical Society of Korea
    • /
    • v.18 no.2
    • /
    • pp.32-39
    • /
    • 1999
  • In this paper, the characteristics of the ray tracing method (RTM) based on the cylindrical wave are discussed for the high frequency vibration analysis of two-dimensional structures. A ray tube describing the emanating cylindrical wave is used to derive the governing equation for incident reflected, and transmitted ray tubes which satisfies the condition at the coupled boundary. The suggested ray model is applied to panel array structures, and the predicted results for 2-panel, 3-panel, and 4-panel array structures are compared to those by Statistical energy analysis (SEA) and Wave intensity analysis(WIA). More enhanced prediction was obtained compared to the SEA, and similar prediction performance was observed to the WIA. Additionally, the RTM has a novel feature that it can estimate the spatially smoothed distribution of vibration energy and vibration intensity. It is expected that the present RTM can be used as one of the useful tools for the high frequency vibration analysis of two-dimensional coupled structures.

  • PDF

THE UPDATED ORBITAL PERIOD OF LOW MASS X-ray BINARY 4U 1323-62

  • CHUANG, PO-SHENG;CHOU, YI;HU, CHIN-PING;YANG, TING-CHANG;SU, YI-HAO;LIAO, NAI-HUI;HSIEH, HUNG-EN;LIN, CHING-PING
    • Publications of The Korean Astronomical Society
    • /
    • v.30 no.2
    • /
    • pp.585-586
    • /
    • 2015
  • 4U 1323-62, a low mass X-ray binary with an orbital period of 2.94 hr, exhibits periodic X-ray dips, which are due to absorption by the bulge of the outer accretion disk. The purpose of this study is to search for orbital period changes using archived X-ray data over a time span of 20 years. We present our preliminary results from analyzing light curves observed by RXTE, BeppoSAX, XMM-Newton and Suzaku. We used the method proposed by Hu et al. (2008) to estimate dip center time and adopted the Observed - Calculated method to measure changes in period. We obtained an orbital period of 2.941917(36) hr and a period derivative of $\dot{P}_{orb}/P_{orb}=(-9.9{\pm}3.5){\times}10^{-7}yr^{-1}$. The F-test result shows that the quadratic ephemeris is describes the evolution of the dip phases better than the linear ephemeris at a greater than 95% confidence level. More X-ray data collected from the early 80s will be included to further refine the orbital ephemeris.

KCl Crystal Growth and High Energy X Ray Expose of Properties (KCl 단결정의 성장 및 고 에너지 X선 조사 특성)

  • Park, Cheol-Woo
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.20 no.1
    • /
    • pp.31-36
    • /
    • 2008
  • Purpose: X ray irradiates material for dose distribution confirmation through material color variation to evaluate about possibility. Materials and Methods: That is rare earth material to pure KCl and KCl impurity Eu adding 0.5mol% by Czochralski method each single crystal grow and observed color variation of KCl X ray irradiation use of linear accelerator. Results: High energy X ray irradiation KCl:Eu show the blue fluorescence with purple color that pure KCl single crystal can confirm by show was not observed, but was colored violet. Conclusion: Colors variation of KCl founds stable color center from radiation and this color variation will be used usefully to X ray measurement material and phantom.

  • PDF

Application of Artificial Neural Networks to Search for Gravitational-Wave Signals Associated with Short Gamma-Ray Bursts

  • Oh, Sang Hoon;Kim, Kyungmin;Harry, Ian W.;Hodge, Kari A.;Kim, Young-Min;Lee, Chang-Hwan;Lee, Hyun Kyu;Oh, John J.;Son, Edwin J.
    • The Bulletin of The Korean Astronomical Society
    • /
    • v.39 no.2
    • /
    • pp.107.1-107.1
    • /
    • 2014
  • We apply a machine learning algorithm, artificial neural network, to the search for gravitational-wave signals associated with short gamma-ray bursts. The multi-dimensional samples consisting of data corresponding to the statistical and physical quantities from the coherent search pipeline are fed into the artificial neural network to distinguish simulated gravitational-wave signals from background noise artifacts. Our result shows that the data classification efficiency at a fixed false alarm probability is improved by the artificial neural network in comparison to the conventional detection statistic. Therefore, this algorithm increases the distance at which a gravitational-wave signal could be observed in coincidence with a gamma-ray burst. We also evaluate the gravitational-wave data within a few seconds of the selected short gamma-ray bursts' event times using the trained networks and obtain the false alarm probability. We suggest that artificial neural network can be a complementary method to the conventional detection statistic for identifying gravitational-wave signals related to the short gamma-ray bursts.

  • PDF

Evaluation of Optical Performance for an Aspheric Lens Connecting with FE Analysis of Injection Molding (사출성형 유한요소해석과 연계한 비구면렌즈의 광학적 특성평가)

  • Park, K.;Um, H.J.;Kim, J.P.;Joo, W.J.
    • Transactions of Materials Processing
    • /
    • v.16 no.1 s.91
    • /
    • pp.25-30
    • /
    • 2007
  • The present study covers an integrated simulation method to evaluate optical performance of an aspheric plastic lens by connecting a finite element (FE) analysis of injection molding with a ray tracing simulation. Traditional ray tracing methods have based on the assumption that the optical properties of a lens are homogeneous throughout the entire volume. This assumption is to a certain extent unrealistic for injection-molded plastic lenses because material properties vary at every point due to the injection molding effects. To take into account the effects of the inhomogeneous optical properties of the molded lens, a new.ay tracing scheme is proposed in conjunction with a FE analysis of the injection molding. A numerical scheme is developed to calculate ray paths on every element layer with more realistic information of the refractive indices which can be obtained through the FE analysis. This information is then used to calculate the ray paths based on the FE mesh of which nodal points have unique index values. The proposed tracing scheme is implemented on the tracing of an aspheric lens, and its validity is ascertained through experimental verification.

The Comparative analysis of X-ray film on Lumbar Scoliosis and HNP by Barge Method (Barge 방식에 의한 요추부 척추측만증과 추간판 탈출증의 X-ray 비교분석)

  • Kim, Gyu-Sub
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.6 no.1
    • /
    • pp.53-61
    • /
    • 2011
  • Objective: The purpose of this study is to evaluate the disc block subluxation for lumbar scoliosis and herniation of nucleus pulpous (HNP). Methods: We used AP & Lateral view X-ray for patients. And we measured of disc wedge angle, vertebral body rotation to evaluate the typical and atypical disc block subluxation. Results: On the analysis of the lateral view X-ray, 4th lumbar intervertebral disc angle (I.V.D angle) showed $4^{\circ}$, $5^{\circ}$, $3^{\circ}$, $0^{\circ}$ in the cases. On the 4th lumbar analysis of the AP view X-ray, lumbar scoliosis showed right disc wedge angle was $11^{\circ}$ (case 1), $17^{\circ}$ (case 2) and left vertebral body rotation was 13mm, 6mm. Lumbar HNP showed left disc wedge angle was $5^{\circ}$ (case 3), $4^{\circ}$ (case 4) and left vertebral body rotation was 2mm, 4mm. Conclusions: Disc block subluxation has been in lumbar scoliosis, but not been in lumbar HNP.

  • PDF