• Title/Summary/Keyword: Ray Method

Search Result 5,500, Processing Time 0.046 seconds

A RAPID DETERMINATION OF $U^{235}$ CONTENTS OF URANIUM SAMPLES UTILIZING HIGH RESOLUTION Ge(Li) DETECTOR (고분해능 Ge(Li) 검출기를 이용한 Uranium 시료내의 $U^{235}$ /$U^{238}$ 함유량의 신속측정)

  • 정문규;조성원;서두환
    • Nuclear Engineering and Technology
    • /
    • v.1 no.1
    • /
    • pp.33-38
    • /
    • 1969
  • Determinations of the isotopic contents of U$^{235}$ and U$^{238}$ in ten uranium samples containing 0.72-89.70 at % U$^{235}$ were carried out in two ways utilizing high resolution Ge (Li) gamma-ray spectrometer. One method is based upon the fact that the intensity of 185.5 kev gamma-ray vary linearly with U$^{235}$ content for a given geometry. Another method applied for the direct determination of the U$^{235}$ / U$^{238}$ isotopic ratios is the precision gamma-ray spectrometric analysis of reactor irradiated uranium samples after allowing a fixed cooling time for one hour. The results obtained by both methods well agree with the values calculated from the isotopic contents of highly enriched original uranium samples measured by mass spectrometer. The precision obtained was well below 5% for most of the isotopic ratios investigated.

  • PDF

A Study on the Fabrication and Detection of Cd$_{80}$ Zn$_{20}$Te Gamma-ray detector with MIM Structure (Cd$_{80}$ Zn$_{20}$Te를 사용한 MIM 구조의 감마선 탐지 소자 제작 및 탐지 특성에 관한 연구)

  • 최명진;왕진석
    • Journal of the Korean Institute of Telematics and Electronics D
    • /
    • v.34D no.4
    • /
    • pp.47-53
    • /
    • 1997
  • We fabricated gamma radiation detector using high resistive p-Cd$_{80}$Zn$_{20}$Te grown by high pressure bridgman method and forming au thin film electrode by chemically electroless deposition method. The device of Au/Cd$_{80}$Zn$_{20}$Te/Au is a typical MIM structure. The characteristic of current-voltage showed good linearity to 3kV/cm but it depend on the square of electric field over 3kV/cm. As the results of rutherford backscattering spectroscope(RBS) and auger spectroscope on the Au/Cd$_{80}$Zn$_{20}$Te, Au penetrated to the surface of Cd$_{80}$Zn$_{20}$Te detector absorbed slightly high energy radiation like a few hundred keV and showed good performance to detect low energy gamma ray.mma ray.

  • PDF

An Optimal Method to Improve the Visual Quality of Medical Images

  • Shin, Choong-ho;Jung, Chai-yeoung
    • Journal of Integrative Natural Science
    • /
    • v.8 no.2
    • /
    • pp.141-144
    • /
    • 2015
  • As the visual quality of X-ray images is a critical reference for the accuracy of the clinical diagnosis, the methods to improve the quality of X-ray images have been investigated. Among many existing methods, using frequency domain filter is a very powerful method to improve the visual quality of images. In this paper, the inherent noises of the input images are suppressed by adding the Laplacian image to the subjected image. The medical X-ray images using the optimal high pass filter has shown improved edges. Further, the optimal high frequency emphasis filter has shown the improved contrast of flat areas by using the result image from the optimal high pass filter. Also the resulting images of the global contrast have improved by the histogram equalization. As a result, the proposed methods have shown enhanced contrast and edges of the images with noise canceling effect.

CONCEPTUAL DESIGN BY APPLIED COMPUTATIONAL ENGINEERING FOR THE MOON EXPLORER PAYLOAD DEVELOPMENT (달탐사용 탑재체 개발을 위한 전산응용 개념 설계)

  • Kim, Jung-Hoon;Jun, Hyoung-Yoll;Ju, Gwang-Hyeok;Kim, Byoung-Soo
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.173-178
    • /
    • 2011
  • Nowadays, SELENE-2 is under development for the moon explorer rover in Japan. AXS(Active X-ray Spectrometer) sensor development among the candidated payloads will be on going by the world-wide co-operation. The thermal design, analysis and test will be specially performed by Korean institutes. CFD techniques are used for the conceptual design and analysis. Thin-shell plate meshes being applied by Monte-Carlo Ray Tracing Method are generated for the thermal radiation analysis. Lumped capacity model is employed for the thermal conduction simulation of the AXS payload itself. Various shapes of the payload configuration with thermal boundary conditions are proposed and selected on the purpose of the analysis of the initial design. The results of the analysis are supposed to be used as the baseline for the further detailed design of the AXS payload in the future.

  • PDF

Automatic Inspection of Assembly Tolerances of Cathod Ray Electron Guns by Vision Probe (비젼프로브를 이용한 CRT 전자총의 자동치수 검사)

  • Park, H.G.;Park, M.C.;Kim, S.W.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.14 no.10
    • /
    • pp.28-34
    • /
    • 1997
  • This paper describes an automatic measurement method for the in-line inspection of assembly tolerances of cathod ray electron guns. The method uses an optical microscope with a CCD camera as a probe. An automatic gap recognition algorthm with digital image processing and a new software autofocus algorithm based on using an optimal edge detector have been developed to improve the measuring accuracy. An inspection system has been proposed and practically implemented for in-line inspection to a real factory automation line. The inspection system consists of a gap inspection part and an eyelet. Total time consumed for inspecting all measuring items is about 10 seconds and the repeatability is below .+-. 5 .mu. m

  • PDF

Fraction Analysis of ε and γ'-iron Nitride in Compound Layer Using X-ray Diffraction (X-선 회절법에 의한 철-질소 화합물층의 ε과 γ'상 분율 해석)

  • Kim, Yoon-Kee
    • Korean Journal of Materials Research
    • /
    • v.16 no.2
    • /
    • pp.85-91
    • /
    • 2006
  • The fraction of $\varepsilon\;and\;\gamma$'-iron nitride in compound layer is predicted by x-ray diffraction using direct comparison method. The validity of formulation models was checked by comparing calculated results with metallographic analysis of iron nitride compound layer grown on steel S45C by gas nitriding. The fraction of $\varepsilon$ calculated by the three phase model, porous-$Fe_3N$/ dense-$Fe_3N$/ mixed layer with $Fe_3N\;and\;Fe_4N$, is 80 percent of that analyzed by etching technique. The $\varepsilon$ fraction predicted by mixed layer model is 122 percent of that measured by microscope.

On the Graphitic Properties of Korean Anthracite (II) X-ray Diffraction Method as an Estimation of the Graphitic Properties of Anthracite (石炭의 黑鉛性에 關한 硏究 (第2報))

  • Sin Sup Oh;Suk Won Lee;Changmoo Lee
    • Journal of the Korean Chemical Society
    • /
    • v.7 no.2
    • /
    • pp.182-185
    • /
    • 1963
  • In the previous paper of the series of researches on the graphitic properties of anthracites, authors have already reported the results on the electrical specific resistance measurements for Korean anthracites in order to develope a simple methods which differentiate graphite from anthracite. In this paper, the X-ray diffraction method and oxidation have been applied and compared with the results which were obtained by the specific resistance measurements in the previous paper. It has been confirmed that there is a parallel relation between the value of specific resistance measurement and height of hexagonal peak by X-ray diffraction, but the color reaction due to graphitic acid by oxidation does not show any definite critical points between graphite and anthracite.

  • PDF

X-Ray Diffraction Measurements of Ion-Irradiated Graphite

  • Kim, Dae-Jong;Jang, Chang-Heui;Kim, In-Sup;Kim, Eung-Seon;Chi, Se-Hwan
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 2005.05a
    • /
    • pp.411-412
    • /
    • 2005
  • There are some differences as a result of comparison between internal and external standard method. Thin-film XRD was used to measure the thin damaged layer by proton irradiation. Experiment was performed by external standard method to measure bulk sample accurately. A little changes of crystallite size and lattice parameter by small dose were observed. X-ray penetrates too deeply above damaged layer of graphite despite of small X-ray incident angle.

  • PDF

A 3-D Propagation Model Considering Building Transmission Loss for Indoor Wireless Communications

  • Choi, Myung-Sun;Park, Han-Kyu;Heo, Youn-Hyoung;Oh, Sang-Hoon;Myung, Noh-Hoon
    • ETRI Journal
    • /
    • v.28 no.2
    • /
    • pp.247-249
    • /
    • 2006
  • In the development of a new wireless communications system, a versatile and accurate radio channel for indoor communications is needed. In particular, the investigation of radio transmission into buildings is very important. In this letter, we present an improved three-dimensional electromagnetic wave propagation prediction model for indoor wireless communications that takes into consideration building penetration loss. A ray tracing technique based on an image method is also employed in this study. Three-dimensional models can predict any complex indoor environment composed of arbitrarily shaped walls. A speed-up algorithm, which is a modified deterministic ray tube method, is also introduced for efficient prediction and computation.

  • PDF

Stress Determination in Epitaxial Lead Titanate Films by Asymmetric X-ray Diffraction Method

  • Uchida, Hiroshi;Kiguchi, Takanori;Wakiya, Naoki;Shinozaki, Kazuo;Mizutani, Nobuyasu
    • The Korean Journal of Ceramics
    • /
    • v.6 no.4
    • /
    • pp.385-389
    • /
    • 2000
  • Residual stresses in epitaxial films were measured by X-ray diffraction method. Lattice strains of the (hkl) planes measured along particular Ψ-angles were converted to the in-plane stress according to the equation of stress-strain tensor conversion. Residual tensile stresses were observed in epitaxial PbTiO$_3$ films deposited on (100) SrTiO$_3$ substrate. Tensile stresses approximately 0.9 GPa were measured in Pb-rich films, while it increased to approximately 2.0 GPa with the decreasing of Pb content in the case of Pb-poor films, which ascribed to the formation of lead and oxygen vacancies (expressed as x in Pb$_1-x$TiO$_3-x$).

  • PDF