• Title/Summary/Keyword: Raw measurement

Search Result 394, Processing Time 0.025 seconds

Comparative study on alveolar bone height of pantomography and multi planar reformatted computed tomography (파노라마방사선사진과 다면상재구성 CT상의 치조골 높이 계측에 대한 비교 연구)

  • Ji Jung-Hyun;Lee Sang-Rae;Lee Byung-Do
    • Imaging Science in Dentistry
    • /
    • v.34 no.3
    • /
    • pp.159-164
    • /
    • 2004
  • Purpose: To compare alveolar bony height of pantomograph with bony height of thin slice, multiplanar reformatted (MPR) Computed Tomograph. Materials and Methods : Panoramic radiograms of 12 young adult patients had been taken by one radologic technitian and the measurements were corrected by magnification ratio (1.20). The slice thickness of Multi-detector Computed Tomography (CT) was at least 1mm for the accuracy. The raw CT datas were imported into the V-works 4.0 (CyberMed Corp., Seoul, Korea) and transformed to MPR images. Pantomographic measurements of alveolar bone were compared to CT values by average mean bony height measurements for the accuracy. Inter-, and Intra-observer variability was evaluated. Results : There was no significant differences between height measurement of pantomography and that of CT (P>0.05). There were no significant differences in either inter-or intra-observer measurements (P>0.05). Conclusion : Pantomography showed relatively high accuracy and precision in measuring alveolar bony height.

  • PDF

Anti-inflammatory Effects of Abeliophyllum distichurn Flower Extract

  • Lee, Jin Wook;Kang, Yoon Joong
    • Proceedings of the Plant Resources Society of Korea Conference
    • /
    • 2018.04a
    • /
    • pp.89-89
    • /
    • 2018
  • Abeliophyllum distichum is a medicinal plant used in regional traditional medicine to relieve pain in inflammatory processes. In this study, anti-inflammatory effects of Abeliophyllum distichum stem (ADS) ethyl acetate extract were examined. Furthermore, possible molecular mechanisms of the anti-inflammatory effects were dissected. The anti-inflammatory activity was investigated by inhibition of lipopolysaccharide (LPS) induced pro-inflammatory cytokine production in murine macrophage-like cell line Raw264.7 cells and human microglial cell line BV2 cells. The measurement of the induced pro-inflammatory cytokine levels were carried out by ELISA. The phosphorylation of ERK1/2, JNK, and MAPK, and the nuclear expression of nuclear factor $NF-{\kappa}B$ p65 were investigated by Western blot analysis. The extract of ADS significantly decreased the production of pro-inflammatory cytokines. In addition, the extract suppressed the phosphorylation of ERK1/2, JNK, and p38 MAPK, and the nuclear translocation of $NF-{\kappa}B$ p65 in activated cells. Our findings provide evidence for the popular use of Abeliophylli distichum in inflammation around Goesan region and also suggest that the stem extract has potential therapeutic benefits against several inflammatory diseases.

  • PDF

Web MGIS with SVG of Kosrae Costal Waters, Micronesia (SVG를 이용한 마이크로네시아 코스레 주변해역 Web MGIS 구축)

  • Park, Sang-Woo;Kim, Jung-Hyun;Lee, Moon-Ock;Kim, Hyeon-Ju;Kim, Jongkyu
    • Journal of Fisheries and Marine Sciences Education
    • /
    • v.26 no.3
    • /
    • pp.485-491
    • /
    • 2014
  • The study of Web MGIS(Marine Geographic Information System) based on the SVG(Scalable Vector Graphics) is mainly performed on effective methodologies which transform real world data to computing world data. Web GUI system has its own target on reliable data service by acquisition of geometric information using HYCOM(HYbrid Coordinate Ocean Model), accurate measurement and graphical visualization. This type of raw data visualization can be built without software tools, yet is incredibly useful for interpreting and communicating data. Even simple visualizations can aid in the interpretation of complex hydrodynamic relationships that are frequently encountered in the marine environment. The Web MGIS provides an easy way for hydrodynamic geoscientists to construct complex visualizations that can be viewed with free software. This study proposes a Web GUI MGIS using FVCOM(Finite Volume Coastal Ocean Model). Finally, we design a Marine Web GUI system of Kosrae Coastal Waters integrating above data models. It must adds more ecological information and the various service item for approach more easily in order to user.

A Study on the Stand-Alone GPS Jump Error Smoothing Scheme (Stand-Alone GPS 점프오차 스무딩 기법 연구)

  • Lee, Tae-Gyoo;Kim, Kwangjin;Park, Heung-Won
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.7 no.12
    • /
    • pp.1015-1023
    • /
    • 2001
  • error behaviour can be considered as a linear combination of low amplitude random noise and abrupt jumps. The reason of jump appearance can be explained by the semi-shading effects(buildings, trees), jamming, high dynamic of vehicle and so on. This study describes the stand-alone GPS error jump smoothing algorithm which is developed based on the scalar adaptive filter. The algorithm consists of the coarse jump smoothing and the fine jump smoothing. On the coarse smoothing step, GPS velocities or position differences are used as the measurement for the scalar adaptive filter. The purpose of adaptive filter is to smooth the jump errors. The coarse positions are detennined by the integration of smoothed velocities. On the fine smoothing step, the differences between GPS positions and the coarse positions are smoothed by another scalar adaptive filter. The reason of fine smoothing is based on the facts that smoothing accuracy depends on the variance ofusefuJ signa\. The coarse smoothing which deal with the difference of positions provides the rough error removing. So the coarse smoothed velocities can have much more low amplitude than the raw ones. The fine smoothing procedure provides high quality of filtering process. Simulation results show the efficiency of proposed scheme.

  • PDF

Bio-vector Generation Framework for Smart Healthcare

  • Shin, Yoon-Hwan
    • Journal of the Korea Society of Computer and Information
    • /
    • v.21 no.1
    • /
    • pp.107-113
    • /
    • 2016
  • In this paper, by managing the biometric data is changed with the passage of time, a systematic and scientifically propose a framework to increase the bio-vector generation efficiency of the smart health care. Increasing the development of human life as a medicine and has emerged smart health care according to this. Organic and efficient health management becomes possible to generate a vector when the biological domain to the wireless communication infrastructure based on the measurement of the health status and to take action in accordance with the change of the physical condition. In this paper, we propose a framework to create a bio-vector that contains information about the current state of health of the person. In the proposed framework, Bio vectors may be generated by collecting the biometric data such as blood pressure, pulse, body weight. Biometric data is the raw data from the bio-vector. The scope of the primary data can be set to active. As the collecting biometric data from multiple items of the bio-recognition vectors may increase. The resulting bio-vector is used as a measure to determine the current health of the person. Bio-vector generating the proposed framework, it can aid in the efficiency and systemic health of healthcare for the individual.

Antioxidative and Antibacterial Activity and Tyrosinase Inhibitory Activity of the Extract and Fractions from Taraxacum coreanum Nakai (흰민들레 에탄올 추출물 및 분획물의 항산화 및 항균활성과 Tyrosinase 저해활성)

  • Im, Do-Youn;Lee, Kyoung-In
    • Korean Journal of Medicinal Crop Science
    • /
    • v.19 no.4
    • /
    • pp.238-245
    • /
    • 2011
  • In this study, we investigated antioxidative activity, antibacterial activity against pathogenic strains including methicillin resistant Staphylococcus aureus (MRSA), and tyrosinase inhibitory activity in 75% ethanol extract of Taraxacum coreanum and its fractions. The total polyphenol and flavonoid contents of the extract were 238.59mg/g and 33.18mg/g and the total polyphenol and flavonoid contents of the ethyl acetate fraction were 427.81mg/g and 148.90mg/g as the highest content of fractions. In DPPH radical scavenging ability, $SC_{50}$ values of the ethyl acetate and butanol fraction were 38.40${\mu}g/ml$ and 82.28 ${\mu}g/ml$, respectively. In antibacterial activity by the disc diffusion assay against S. aureus, S. epidermidis and MRSA, the ethyl acetate fraction showed stronger antibacterial activity than other fractions and the extract. Especially, the ethyl acetate fraction was exhibited effective antibacterial activity against MRSA. In the cytotoxicity measurement by MTT assay, the extract and fractions were exhibited Raw 264.7 cell viabilities of 96.32~143.21% as nontoxic result in concentration of 5~100 ${\mu}g/ml$. As a result, the ethyl acetate fraction of the 75% ethanol extract from T. coreanum could be applicable to functional materials for related fields.

Power Quality Monitoring System with a New Distributed Monitoring Structure

  • Won, Dong-Jun;Chung, Il-Yop;Kim, Joong-Moon;Ahn, Seon-Ju;Moon, Seung-Il;Seo, Jang-Cheol;Choe, Jong-Woong
    • KIEE International Transactions on Power Engineering
    • /
    • v.4A no.4
    • /
    • pp.214-220
    • /
    • 2004
  • Power quality monitoring is the cornerstone for power quality analysis, diagnosis and improvement. The measurement of power quality (PQ) evolves from instantaneous metering to continuous monitoring. Furthermore, recent technologies enable us to construct more flexible, reliable, rapid and economical power quality monitoring system (PQMS). Therefore, this paper presents an improved PQMS with a new distributed monitoring structure. The proposed PQMS consists of a PQ meter, PQ analyzer and GUI. The PQ meter only collects raw data and the PQ analyzer performs power quality analysis. It has several advantages compared to conventional structures in economic efficiency, modularity, speed, etc. PQ monitoring algorithms to catch steady-state trends and to detect PQ events are also adapted to the proposed structure. Using the proposed structure and monitoring algorithm, a prototype PQMS is constructed and real-time testing is performed.

Fault Diagnosis of Transformer Based on Self-powered RFID Sensor Tag and Improved HHT

  • Wang, Tao;He, Yigang;Li, Bing;Shi, Tiancheng
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.5
    • /
    • pp.2134-2143
    • /
    • 2018
  • This work introduces a fault diagnosis method for transformer based on self-powered radio frequency identification (RFID) sensor tag and improved Hilbert-Huang transform (HHT). Consisted by RFID tag chip, power management circuit, MCU and accelerometer, the developed RFID sensor tag is used to acquire and wirelessly transmit the vibration signal. A customized power management including solar panel, low dropout (LDO) voltage regulator, supercapacitor and corresponding charging circuit is presented to guarantee constant DC power for the sensor tag. An improved band restricted empirical mode decomposition (BREMD) which is optimized by quantum-behaved particle swarm optimization (QPSO) algorithm is proposed to deal with the raw vibration signal. Compared with traditional methods, this improved BREMD method shows great superiority in reducing mode aliasing. Then, a promising fault diagnosis approach on the basis of Hilbert marginal spectrum variations is brought up. The measured results show that the presented power management circuit can generate 2.5V DC voltage for the rest of the sensor tag. The developed sensor tag can achieve a reliable communication distance of 17.8m in the test environment. Furthermore, the measurement results indicate the promising performance of fault diagnosis for transformer.

Acetone PLIF for Fuel Distribution Measurements in Liquid Phase LPG Injection Engine (LPG 액상분사 엔진에서 아세톤 PLIF를 이용한 연료분포 측정기법 연구)

  • 오승묵;박승재;허환일;강건용;배충식
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.12 no.1
    • /
    • pp.74-82
    • /
    • 2004
  • Planar laser-induced fluorescence(PLIF) has been widely used to obtain two dimensional fuel distribution. Acetone PLIF is chosen because fluorescence signal from acetone as a fluorescent tracer is less sensitive to oxygen quenching than other dopants. Acetone PLIF is applied to measure quantitative air excess ratio distribution in an engine fueled with LPG. Acetone is excited by KrF excimer laser (248nm) and its fluorescence image is acquired by ICCD camera with a cut-off filter to suppress Mie scattering from the laser light. For the purpose of quantifying PLIF signal, an image processing method including the correction of laser sheet beam profile is suggested. Raw images are divided by each intensity of laser energy and profile of laser sheet beam. Inhomogeneous fluorescence images scaled with the reference data, which is taken by a calibration process, are converted to air excess ratio distribution. This investigation shows instantaneous quantitative measurement of planar air excess ratio distribution for gaseous fuel.

Optical and Conduction Properties with the Thickness Variation of the Light-emitting Layer in PVK-Based PLED (PVK계 PLED에서 발광층의 두께 변화에 따른 광학 및 전도 특성)

  • Jang, Kyung-Uk;Ahn, Hee-Cheul;Shin, Eun-Cheul;Lee, Eun-Hye;Yoon, Hee-Myung;Chung, Dong-Hoe;Ahn, Joon-Ho;Lee, Won-Jae;Kim, Tae-Wan
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2007.11a
    • /
    • pp.373-374
    • /
    • 2007
  • We have fabricated polymer light-emitting diodes(PLED) in a structure of Glass/ITO/PVK/Al. Poly(N-vinylcabazole) (PVK) was deposited on the ITO glass with the spin coating method. PVK thickness is respectively 500nm, 300nm, 250nm and 200nm with the spin coter rotation speed of 2000, 3000, 4000 and 5000rpm. V-I, wavelength-transmittance, P-L and SEM of the fabricated devices were measured. From the result of P-L measurement, it was kept the optic properties of PVK raw powder when PVK thickness is 250nm. The knee-voltage of PVK PLED with 250nm thickness was 7V.

  • PDF