• Title/Summary/Keyword: Rates of application

Search Result 1,865, Processing Time 0.033 seconds

Studies on the Nitarte Acumulation in Forages (사료작물의 질산태질소 축적에 관한 연구)

  • 허삼남
    • Journal of The Korean Society of Grassland and Forage Science
    • /
    • v.12 no.4
    • /
    • pp.239-245
    • /
    • 1992
  • Aspects of nitrate accumulation of forages growing on grasslands in Chonbuk Province, and the effects of different rates of N fertilizer on the total nitrogen and nitrate contents of sudangrass-hybrid and corn were studied through the 1991 growing season. The results obtained are summarized as follows: I . Thc nitrate content of the forages was increased by N application and decreased as the plants matured. 2. Nitrate concentration was high throughout the growing season in samples collected at Namweon-gun 1, which was considered as potentially unsafe. 3. Total nitrogen and nitrate content of plants generally increased with the increasing rates of N fertilizer, but not statistically significant among treatments except the plot of 25 kg N/lOa. 4. The annual crops had a greater tendency to accumulate nitrate than the perennial forage species. 5. It is suggested that high level of N fertilizer and manure may result in toxic levels of nitrate, and special attention must be given in feeding them.

  • PDF

A Study on the Characteristics of the Electronic EGR Valve for Gasoline Engine (가솔린엔진용 E-EGR 밸브 특성에 관한 연구)

  • Park, Cheol-Woong;Kim, Chang-Gi
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.16 no.1
    • /
    • pp.127-133
    • /
    • 2008
  • Since the 1960's, exhaust gas recirculation(EGR) has been used effectively in spark ignition(SI) engines to control the exhaust emissions of the oxides of nitrogen(NOx). The most important requirements for the application of EGR systems to conventional SI engines are controllable flow rate and good dynamic response. In order to evaluate the characteristics of the electronic EGR valve, a test bench which is consisted of blower, heater, air flow meter and driving unit for electronic EGR valve was set up to simulate engine operating conditions. During the tests, the valve actuation parameters were controlled and the valve lifts and flow rates were measured to infer the characteristics of EGR valve. The results confirmed the capabilities of mathematical analysis and it seems that the correction for the valve lift and potentiometer output is necessary to achieve precise control of EGR rates.

Reliability Evaluation of Power Distribution System Considering Maintenance Effects (유지보수 영향을 고려한 배전계통 신뢰도 평가)

  • Moon, Jong-Fil;Shon, Jin-Geun
    • The Transactions of the Korean Institute of Electrical Engineers P
    • /
    • v.59 no.2
    • /
    • pp.154-157
    • /
    • 2010
  • In this paper, the Time-varying Failure Rates(TFR) of power distribution system components are extracted from the recorded failure data of KEPCO(Korea Electric Power Corporation) and the reliability of power distribution system is evaluated using Mean Failure Rate(MFR) and TFR. The TFR is approximated to bathtub curve using the exponential and Weibull distribution function. In addition, Kaplan-Meier estimation is applied to TFR extraction because of incomplete failure data of KEPCO. Also the reliability of the real power distribution system of Korea is evaluated using the MFR and TFR extracted from real failure data, respectively and the results of each case are compared with each other. As a result, it is proved that the reliability evaluation using the TFR is more realistic than MFR. In addition, it is presented that the application method at power distribution system maintenance and repair using the result of TFR.

Electron Spin Resonance (ESR) and Microwave Absorption Studies of Superparamagnetic Iron Oxide Nanoparticles (SPIONs) for Hyperthermia Applications

  • Choi, Yong-Ho;Yi, Terry;Kim, Do-Kyung
    • Journal of the Korean Ceramic Society
    • /
    • v.48 no.6
    • /
    • pp.577-583
    • /
    • 2011
  • Stabilized biocompatible superparamagnetic iron oxide nanoparticles (SPIONs) were prepared by controlled coprecipitation method for hyperthermia application. ESR measurements determined that all of the interactions in the individual SPIONs (1 nm and 11 nm) were antiferromagnetic in nature because the ions contributed to the magnetization with a range of magnetic moments. In-situ monitoring of the temperature increment was performed, showing that the microwave absorption rate of the SPIONs was dispersed in an appropriate host media (polar or non-polar solvents) during microwave irradiation. Microwave absorption energy rates and heat loss of SPIONs in solvent were calculated by non-linear data fitting with an energy balance equation. The microwave absorption rates of SPIONs dispersed in solvent linearly increases when the concentration of SPIONs increases, implying that the microwave absorption rate can be tunable by changing the concentration of SPIONs.

Application of Equivalent Walking Loads for Efficient Analysis of Floor Vibration Induced by Walking

  • Kim, Gee-Cheol;Kim, Jae-Yeol
    • Journal of Korean Association for Spatial Structures
    • /
    • v.4 no.4 s.14
    • /
    • pp.65-76
    • /
    • 2004
  • Walking loads are usually considered as nodal loads in the finite element vibration analysis of structures subjected to walking loads. Since most of the walking loads act on elements not nodes, the walking loads applied on the elements should be converted to the equivalent nodal walking loads. This paper begins with measuring walking loads by using a force plate equipped with load cells and investigates the characteristics of the walking loads with various walking rates. It is found that the walking loads are more affected by walking rates than other parameters such as pedestrian weight, type of footwear, surface condition of floor etc. The measured walking loads are used as input loads for a finite element model of walking induced vibration. Finally, this paper proposes the equivalent nodal walking loads that are converted from the walking loads acting on elements based on finite element shape functions. And the proposed equivalent walking loads are proved to be applicable for efficient analysis of floor vibration induced by walking loads.

  • PDF

Adsorption Study on the Radioactive Liquids by Korean Vermiculite (한국산(韓國産) Vermiculite에 의(依)한 방사성동위원소(放射性同位元素) 흡착연구(吸着硏究))

  • Moon, Suc-Hyong
    • The Korean Journal of Nuclear Medicine
    • /
    • v.7 no.1
    • /
    • pp.51-54
    • /
    • 1973
  • The use of ion-exchange resins for the treatment of radioactive wastes has many advantages, but thes eare rather expensive as compared with the Korean vermiculite. The Korean vermiculite has slightly different chemical constituents from the ones produced in other countries, and its physical properties might be applicable to the management of radioactive waste, in a small nuclear installation. The decontaminating effect of Korean vermiculite for the low-level radioactive liquid was investigated. $^{106}Ru,\;^{90}Sr,\;and\;^{137}Cs$ were utilized for the experiments. The removal rates by Korean vermiculite were calculated for $^{106}Ru,\;^{90}Sr\;and\;^{137}Cs$ and the removal rates increased as the weight of vermiculite in the exchange column increased. The decontaminating constants, $K_d$ of the Korean vermiculite for $^{106}Ru,\;^{90}Sr\;and\;^{137}Cs$ were 2.7, 69.3 and 263ml/g respectively. Through the results of experiments, the application of Korean vermiculite column to the treatment of low-level radioactive waste is quite feasible.

  • PDF

A cost-reliability model for the optimal release time of a software system

  • Lee, Won-Hyung;Kim, Yong-Whi
    • Proceedings of the Korean Operations and Management Science Society Conference
    • /
    • 1991.10a
    • /
    • pp.405-421
    • /
    • 1991
  • In this paper, faults existing in a software system is classified into three types; simple, degenerative and regenerative faults. The reliability functions and failure rates of both a software module and system which have a mixture of such faults are obtained and the expected number of failures in the system after time T is also derived. Using the formulas obtained, a cost-reliability model and an efficient algorithm for optimal software release time are proposed via nonlinear programming formulation ; minimizing the total test cost with constraints on the failure rates of each module. Application of this model to several cases are presented and it appears to be more realistic.

  • PDF

The Spray and Combustion Characteristics by the Ratio of Cetane Number Enhancing Additives in Diesel (세탄가 향상 혼합 연료에 따른 디젤 연료의 분무 및 연소특성에 관한 연구)

  • Kim, J.H.;Lee, S.W.;Lee, H.S.;Choi, J.H.;Lee, Y.C.;Cho, Y.S.
    • Journal of ILASS-Korea
    • /
    • v.14 no.2
    • /
    • pp.84-89
    • /
    • 2009
  • In this research, combustion and spray characteristics were investigated experimentally in a constant volume chamber by applying different composition rates of octane number in diesel fuel to a common-rail system. For the visualization, the experiment was carried out under different injection pressures and different cetane number. The test was done by three different types of diesel fuels, the different composition rates of cetane number in diesel fuel and HBD. In summary, this research aims to investigate the combustion characteristics in the application of fuels and compare the results with performance of conventional diesel fuel. This experimental data may provide with fundamentals of the development of diesel engines in future.

  • PDF

Heat and mass transfer in laminar-wavy film (층류-파동 액막의 열 및 물질전달)

  • 김병주;김정헌
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.10 no.4
    • /
    • pp.431-439
    • /
    • 1998
  • Falling film absorption process is an important problem in application such as absorption chillers. The presence of waves on the film affects the absorption process significantly. In the present study the characteristics of heat and mass transfer in laminar-wavy falling film were studied numerically. The wavy flow behavior was incorporated in the energy and diffusion equation. The numerical solution indicated that the interfacial wave increased the transfer rates remarkably. Interfacial shear stress and wave frequency seemed to be the dominant factors on the film Nusselt number and Sherwood number in the wavy film. A comparison of the transfer rates of the wavy film to that of the smooth film showed that the mass transfer rate could be increased by more than 50%.

  • PDF

Development and Application Capillary Tube Viscometer Transient Flow Concept (과도유동현상을 이용한 모세관점도계 개발 및 적용)

  • Suh, Sang-Ho;Cho, Min-Tae;Kim, Dong-Joo;Roh, Hyung-Woon
    • 유체기계공업학회:학술대회논문집
    • /
    • 2002.12a
    • /
    • pp.489-492
    • /
    • 2002
  • The objective of the present study were to measure the viscosities of non-Newtonian fluids by the transient flow concept in a capillary tube and to apply to hemodynamic studies and pump performance evaluations. The developed capillary tube viscometer could be used to measure the viscosities of the non-Newtonian fluids for a wide range of the shear rate by a run of experiment in a very short time interval. The measured viscosities of water and blood fur different shear rates were good agreement with those of the well established data. The measured viscosities for muddy water varied with the shear rates.

  • PDF