• 제목/요약/키워드: Rated load

검색결과 315건 처리시간 0.031초

고효율 복합형 진공펌프의 로터다이나믹 해석 (A Rotordynamics Analysis of High Efficiency and Hybrid Type Vacuum Pump)

  • 김병옥;이안성;노명근
    • 한국소음진동공학회논문집
    • /
    • 제17권10호
    • /
    • pp.967-975
    • /
    • 2007
  • A rotordynamic analysis was performed with a dry vacuum pump, which is a major equipment in modern semiconductor and LCD manufacturing processes. The system is composed of screw rotors, lobes picking air, helical gears, driving motor, and support rolling element bearings of rotors and motor. The driving motor-screw rotor system has a rated speed of 6,300 rpm, and was modeled utilizing a rotordynamic FE method for analysis, which was verified through 3-D FE analysis and experimental modal analysis. As loadings on the bearings due to the gear action were significant in the system considered, each resultant bearing load was calculated by considering the generalized forces of the gear action as well as the rotor itself. Each resultant bearing loading was used in calculating each stiffness of rolling element bearings. Design goals are to achieve wide separation margins of lateral and torsional critical speeds, and favorable unbalance responses of the rotor in the operating range. Then, a complex rotordynamic analysis of the system was carried out to evaluate its forward synchronous critical speeds, whirl natural frequencies and mode shapes, unbalance responses under various unbalance locations, and torsional interference diagram. Results show that the entire system is well designed in the operating range. In addition, the procedure of rotordynamic analysis for dry vacuum pump rotor-bearing system was proposed and established.

Internet Protocol TV 환경에서 효율적인 웹 탐색기법의 사용성에 대한 비교 연구 (Comparative Study on the Usability of Semantic Zooming Methods for Efficient Web Browsing on Internet Protocol TV)

  • 홍지영;채행석;조운정;정대현;김종완;김성은;이혜정;한광희
    • 대한인간공학회지
    • /
    • 제27권4호
    • /
    • pp.15-26
    • /
    • 2008
  • Recently, Internet Protocol TV technology has a latent power for searching information by using internet-connected interactive TV media. It is hard to browse and search web site conveniently since the visual and input devices are not sufficient for navigating through the websites. Zoomable user interface is a possible solution that may reduce users' task load and improve their performance. In this paper, we made three types of web browsers as scroll, physical zooming and semantic zooming type. Fifteen participants asked to do searching tasks and their task time, accuracy and subjective responses are recorded. In the result, though scroll type is evaluated more efficient than other types in task time and accuracy since participants are familiar with scroll type interface, semantic zooming type is highly rated in subjective responses such as perceived searching efficiency, satisfaction and joyfulness. This result implied semantic zooming is a possible solution which is improving user experience of searching websites using Internet Protocol TV.

직류배전용 가변속 디젤발전기 개발에 관한 연구 (A Study on the Development of a Variable Speed Diesel Generator for DC Distribution)

  • 박기도;김종수
    • 해양환경안전학회지
    • /
    • 제25권1호
    • /
    • pp.117-121
    • /
    • 2019
  • 본 연구에서는 국내외적으로 환경문제 및 에너지절감의 일환으로 직류배전시스템을 선박에 적용하려는 연구 및 실증이 활발히 수행되고 있으며, 발전기를 직류배전시스템에 적용하기 위해서는 가변속 엔진을 적용하여 저부하 영역에서 발전기의 엔진 회전수를 줄여 연료소모량을 절감할 수 있는 방안이 제시되고 있다. 본 논문에서는 기존의 디젤발전기를 이용하여 발전기 컨트롤러, 가버너, AVR을 이용하여 직류배전용 가변속발전기를 구성하였으며, 발전기의 시스템 구성 방법, 가변속 발전에 따른 전력품질 시험(전압 및 주파수 변동특성, 부하변동 특성)을 통해 가변속 발전기의 전력특성을 분석 하였다. 가변속 발전기의 전압(250 ~ 440 VAC) 및 주파수(34 ~ 60 Hz)는 정격의 60 ~ 100 %로 구성하였으며, 엔진은 1100 ~ 1800 rpm 범위에서 운전되도록 설정 하였다. 부하변동에 따라 발전기의 엔진속도를 변경시켜서 발전기 출력의 전압, 전류, 주파수가 전력량에 따라 안정적으로 변동되는 것을 확인하였다.

절연형 전류원 PFC 컨버터를 사용한 넓은 출력범위를 가지는 고효율 OBC에 대한 연구 (A Study on High Efficiency OBC with Wide Range Output Using Isolated Current-Fed PFC Converter)

  • 김형식;김희준;안준선
    • 한국정보전자통신기술학회논문지
    • /
    • 제12권1호
    • /
    • pp.99-105
    • /
    • 2019
  • 전기 자동차의 배터리 충전용 OBC는 주로 PFC회로와 절연형 DC-DC 컨버터 회로를 포함한 2단으로 구성된다. 일반적으로 PFC 회로로는 구조가 간단한 비절연형 부스트 컨버터가 사용되고, 절연형 DC-DC 컨버터로는 ZVS(Zero Voltage Switching)가 가능한 공진형 컨버터가 이용되고 있다. 전기자동차의 주행거리 증가에 따른 넓은 배터리 출력에 대응하기 위해서는 OBC의 넓은 출력범위가 필요하지만, 이러한 시스템 회로 구성에서는 ZVS를 위한 회로설계의 한계와 제어기 구성이 복잡해지기 때문에 배터리 충전에 요구되는 넓은 범위의 출력에 효과적으로 대응하기에는 어려움이 있다. 본 논문에서는 절연형 전류원 방식의 PFC 회로와 벅 DC-DC 컨버터로 구성된 OBC를 제안하였다. 제안된 OBC는 회로 및 제어기 구성이 용이하고, 넓은 출력범위에 대한 대응이 가능하다. 제안된 회로의 유효성을 검증하기 위해 3.3㎾급 시작품을 제작 하였으며, 동작결과 출력전압 150V~400V에서 동작안정성 및 정격 부하 조건에서 최대 효율 94.4%, 최대 역률 99.2%를 확인하였다.

난방용 보일러에서 NG-H2 혼소율에 따른 열 및 공해 성능의 검토 (A Study on the Thermal and Pollution Performances of the Heating Boilers with NG-H2 Mixture Ratio)

  • 서준선;김영직;박준규;이창언
    • 한국수소및신에너지학회논문집
    • /
    • 제32권6호
    • /
    • pp.573-584
    • /
    • 2021
  • Hydrogen is evaluated as one of the new energy sources that can overcome the limitations and pollution problems of conventional fossil fuels. Although hydrogen is CO2-free, attention is required in NOx emission and flame stability in order to use hydrogen in existing gas fuel system. However, use of electric grids is an unrealistic strategy for decarbonization for residential and commercial heating. Instead, use of H2 that utilizes city gas grid is suggested as a reasonable alternative in terms of compatibility with existing systems, economic feasibility, and accessibility. In this study, the thermal efficiency and NOx performance of the boiler according to the H2 mixture ratio and vapor humidified ratio are reviewed for a humidified NG-H2 boiler that vapor humidity to combustion air. Mixed fuel with H2 (20%) is almost similar to NG in terms of efficiency, flame temperature, and pollution performance. Thus, it is expected to be directly compatible with the existing NG system. If the exhaust temperature of the H2 boiler is lowered to around 60℃ at a humidified ratio of 15-20%, the NOx emission concentration can be suppressed to about 5-10 ppm. The level of efficiency reaches 87% of the rated load efficiency, which is equivalent to the highest grade achievable.

Performance control analysis of concrete-filled steel tube sepa-rated spherical joint wind power tower

  • Yang Wen;Guangmao Xu;Xiazhi Wu;Zhaojian Li
    • Structural Engineering and Mechanics
    • /
    • 제87권2호
    • /
    • pp.137-149
    • /
    • 2023
  • In this study, to explore the working performance of the CFST split spherical node wind power tower, two groups of CFST split spherical joint plane towers with different web wall thicknesses and a set of space systems were analyzed. The tower was subjected to a low-cycle repeated load test, and the hysteresis and skeleton curves were analyzed. ABAQUS finite element simulation was used for verification and comparison, and on this basis parameter expansion analysis was carried out. The results show that the failure mode of the wind power tower was divided into weld tear damage between belly bar, high strength bolt thread damage and belly rod flexion damage. In addition, increasing the wall thickness of the web member could render the hysteresis curve fuller. Finally, the bearing capacity of the separated spherical node wind power tower was high, but its plastic deformation ability was poor. The ultimate bearing capacity and ductility coefficient of the simulated specimens are positively correlated with web diameter ratio and web column stiffness ratio. When the diameter ratio of the web member was greater than 0.13, or the stiffness ratio γ of the web member to the column was greater than 0.022, the increase of the ultimate bearing capacity and ductility coefficient decreased significantly. In order to maximize the overall mechanical performance of the tower and improve its economy, it was suggested that the diameter ratio of the ventral rod be 0.11-0.13, while the stiffness ratio γ should be 0.02-0.022.

온실가스감축효과를 고려한 태양광 연계형 에너지저장장치(ESS) 보급전략에 대한 연구 (A Research on PV-connected ESS dissemination strategy considering the effects of GHG reduction)

  • 이원구;김강원;김발호
    • 에너지공학
    • /
    • 제25권2호
    • /
    • pp.94-100
    • /
    • 2016
  • 에너지저장장치(ESS)는 전력수급 불균형 해소, 신재생에너지의 출력안정, 주파수 조정용 등 전력공급 안정성 향상 및 효율적 전기에너지사용 등에 기여하는 중요자원으로, 전세계적으로 '23년까지 '14년 설치용량의 약 30배가 증가한 55.9GWh의 보급이 전망되고 있다. 이와 같이 급증하는 세계시장에서 국내 ESS 업계의 경쟁력 확보를 위해서는 자국내 설치실적(Track Record) 확보가 필요한데, 우리나라는 주파수 조정용(FR용(用))과 그간 지속되어 왔던 전력수급 불균형 상황에 대비하기 위한 부하이동용 중심으로 ESS를 보급하여 왔다. 하지만, 주파수 조정용의 경우 통상적으로 화력발전소 정격용량의 약 5% 범위에서 설치효용이 발생하는 것으로 평가되고 있어, 화력발전이 비약적으로 증가하지 않는 한 국내 시장의 확장성이 부족하다고 할 수 있으며, 여유로운 예비력 확보정책에 따라 부하이동용에 대해서도 보급필요성이 저하되고 있는 바, 새로운 방식의 보급확대 대상이 필요하다고 할 수 있다. 유망한 신규보급대상은 간헐적 출력의 약점은 있으나, 신기후체제 대응과 산업육성을 위해 지속적으로 추진예정인 신재생에너지와의 연계설치를 통해 신재생에너지의 출력을 안정화 하고, 신재생에너지 발전량의 계통투입시기 조절을 통한 이산화탄소 저감효과를 기대할 수 있는 분야라고 할 수 있다. 본 연구에서는 향후 에너지정책의 최대 화두인 신기후체제 대응을 위한 온실가스 감축수단을 활용할 수 있도록, 태양광 연계형 ESS 충방전모드를 온실가스 저감효과를 고려토록 설계한 후, 투자유도를 위한 REC 가중치 산정방법에 대한 정책대안을 제시하였다.

저열량 가스 적용에 따른 천연가스엔진의 대응 방안 연구 (Countermeasures to the Introduction of Low Caloric Gas Fuel for Natural Gas Engine)

  • 박철웅;김창기;오세철;이장희
    • 한국가스학회지
    • /
    • 제25권2호
    • /
    • pp.34-41
    • /
    • 2021
  • 국내에서 사용되는 천연가스가 저열량화 되면서 발생할 수 있는 문제점에 대응하기 위해서는 국내 산업용 가스기기에 미칠 수 있는 문제점을 사전에 파악하고, 이를 기반으로 에너지의 효율적인 사용을 위한 대응방안이 선행되어야 한다. 본 연구에서는 EURO-6 규제를 대응하는 희박연소방식의 천연가스 엔진을 이용할 경우, 저열량 가스의 도입으로 인한 엔진 출력성능과 효율의 저하 문제를 해결하기 위해, 실험을 토대로 한 구체적인 제어방안과 결과를 제시하고자 하였다. 전부하 운전조건인 1,400 rpm의 엔진 회전수에서 스로틀이 전부 개방된 전부하 조건과 정격운전조건의 엔진회전수인 2,100 rpm, 450 Nm의 토크 조건에서 점화시기로 대표되는 제어변수에 의한 개선효과 확인을 위해, 각 가스연료에 대해서 점화시기를 변경하여 열효율 및 배출가스특성을 파악하고 최적화하였다. 전부하조건에서 토크를 기준으로 가장 낮은 값을 보이는 순수메탄의 경우 기준 조건에서 약 2 CAD 정도 점화시기를 진각하면 NOx 배출의 큰 증가 없이 토크를 보상할 수 있다.

냉각수(冷却水) 용량(容量)이 소형(小型) 디젤기관(機關)의 성능(性能)에 미치는 영향(影響) (Effect of Cooling Water Capacity on the Engine Performance for Small Diesel Engine)

  • 명병수;김성래
    • 농업과학연구
    • /
    • 제13권2호
    • /
    • pp.265-278
    • /
    • 1986
  • 동력경운기(動力耕耘機) 탑재용(塔載用) 6kW 수냉식(水冷式) 디젤기관(機關)의 성능향상(性能向上)을 도모(圖謀)하기 위(爲)하여 현존(現存)의 냉각장치(冷却裝置)는 그대로 이용(利用)하고 냉각수(冷却水) 용량(容量)만을 2700cc에서 2800cc, 2900cc, 3000cc, 3100cc 로 4수준(水準)으로 변화(變化)시키면서 기관(機關)의 출력(出力), 연료소비율(燃料消費率), Torque, 냉각수(冷却水) 및 윤활유(潤滑油)의 온도(溫度)와 기관(機關)의 마찰손실(摩擦損失)을 D.C. dynamometer를 이용(利用)하여 측정(測定)한 결과(結果)는 다음과 같은 결론(結論)을 얻었다. 1. 공시기관(供試機關)의 출력성능(出力性能)은 한국공업표준규격범위(韓國工業標準規格範圍)에는 들었으나 정격표시마력(定格表示馬力)이 실험결과(實驗結果)보다 약(約) 10% 정도(程度) 낮게 표기(表記)되어 있으며 연료소비율(燃料消費率)은 297.78g/kW-h 로 약간(若干) 높은 수준(水準)이었으며 냉각수(冷却水) 온도(溫度)는 $101^{\circ}C$로 SAE기준(基準)인 $88^{\circ}C$보다는 $13^{\circ}C$ 정도(程度)가 높았다. 2. 공시기(供試機)의 마찰손실(摩擦損失)은 정격상용회전(定格常用回轉)인 2200rpm에서 3.65kW 이었으며 기보고(旣報告)된 측정치(測定値)보다 약간(若干) 높은 범위(範圍)이었다. 3. 냉각수(冷却水) 용량(容量)을 2700cc에서 3100cc로 14.8% 증가(增加)시켰을 때 출력(出力)은 6.7kW에서 7.13kW로 0.43kW의 6.3%가 증가(增加)하였다. Torque도 냉각수(冷却水) 용량(容量) 2700cc일 때 28.85N.m에서 3100cc일 때 30.706N.m로 6.39%가 증가(增加)하는 경향(傾向)을 보였다. 4. 냉각수(冷却水) 용량(容量) 2700cc에서 3100cc로 증가(增加)시켰을 때 연료소비율(燃料消費率)은 310.85g/kW-h에서 304.14g/kW-h로 6.69g/kW-h가 감소(減少)하였으며 30분간(分間) 전하중운전시(全荷重運轉時) 냉각수(冷却水)의 온도(溫度)는 냉각수(冷却水) 용량(容量)이 2700cc에서 $101^{\circ}C$였고 냉각수(冷却水) 용량(容量)이 3100cc에서 $88^{\circ}C$$13^{\circ}C$가 감소하여 3100cc일 때는 SAE 표준(標準)과 같았고 윤활유(潤滑油) 온도(溫度)는 냉각수(冷却水) 용량(容量)이 2700cc일 때, $76.7^{\circ}C$였으며 냉각수(冷却水) 용량(容量)이 3100cc에서는 $70.4^{\circ}C$$6.4^{\circ}C$가 감소하였다. 5. 기계효율(機械效率)은 냉각수(冷却水) 용량(容量)이 2700cc에서 70.08%였고 냉각수(冷却水) 용량(容量)이 3100cc일 때는 71.08%로 0.95%가 증가(增加)하였다.

  • PDF

빙축열냉방시스템의 운전효율에 관한 조사연구 (Study and Survey of Operating Efficiency with Cool Storage System)

  • 손학식;심창호;김강현;김재철
    • 에너지공학
    • /
    • 제11권1호
    • /
    • pp.1-9
    • /
    • 2002
  • 우리나라에 보급된 축냉시스템 이용효율 향상과 전력사용 합리화 방안을 제시함으로써 빙축열 시스템의 보급활성화를 통한 하절기 피크부하 경감에 기여코자 빙축열 설비의 성능시험을 실시한 결과 COP주간 3.8, 축열 3.0대비 30% 이상 성능이 감퇴한 주간 2.6∼3.4, 축열 2.1∼3.0정도로 냉동기가 가동되고 있으며, 축열율은 15개 건물 중 3개 건물(21.4%)만이 축열능력 대비 40% 이상의 축열을 실시하고 있는 것으로 분석되었다. 이처럼 운전성능 감퇴를 개선하기 위하여는 축냉(빙축열)설비 운전시 빈번히 발생하는 3-Way 밸브오동작, 냉각능력 감소, 팽창밸브 동작 부적절, 운전모드별 제어설정 오류 등에 의한 축냉능력 감퇴현상을 시정하고, 냉동기의 브라인배관 By-pass, Ice Slurry system운전모드별 배관분리, 냉온수펌프의 회전수제어 등의 배관계통 개선검토가 필요하며, 축냉(비축열) 시스템특징 별로는 Ice on Coil system은 냉방부하 확장성에 제약, Ice Ball system은 축열조의 수밀유지, Ice lens system의 제빙운전시 COP 저하, Ice Slurry system은 주간 운전시 저온운전에 따른 낮은 COP, Ice Harvest system은 Hot Gas 탈빙으로 동력손실증가 등에 대한 개선이 향후 축냉(빙축열)시스템의 운전성능 향상을 위해 필요한 것으로 도출되었다.