• 제목/요약/키워드: Rated load

검색결과 314건 처리시간 0.023초

유도가열용 전원장치 개발 (Development of Power Supply for Induction Heating System)

  • ;오성철;김요희;계문호;하성운
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.531-536
    • /
    • 1991
  • This paper describes a POWER MOSFET inverter suitable for medium frequency induction heating applications. A series scheme is employed, which is operated at zero phase of the resonant load by PLL control. This ensures maximum power transfer, good efficiency, low EMI noise and reliable operation. Circuit configuration and performance are discussed and design criteria are given. Implementation of a prototype rated at 5KW, $100{\sim}300KHz$ is discribed and experimental results are given.

  • PDF

30kVA 주상 변압기의 정격부하에 의한 열분포에 관한 연구 (A Study on the Thermal distribution of the 30kVA Pole Transformer Due to the Rated load)

  • 김민규;김정태;구자윤;송기동;조연옥;하복남
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1991년도 하계학술대회 논문집
    • /
    • pp.292-295
    • /
    • 1991
  • The life of the transformers is significantly dependent upon the rate of thermal deterioration in the employed insulating materials. Therefore, the study should be based on hot-spot temperature considerations for the life expectancy and possible overload of transformer. We have measured directly temperature of the winding using thermocouples and these test results are compared with those obtained from computer simulation. In this work, our fundamental investigations are well described for the analysis in the thermal distribution of the oil-immersed transformer with the rating of 30kVA.

  • PDF

접촉상태에 있는 의 초정밀 역전방지클러치의 3D SPRAG TYPE 내구성 평가에 관한 연구 (A Study on Endurance Estimation of 3D Sprag Type Ultra Precision Reverse-Locking Clutches under Contact Condition)

  • 이상범;서정세;이석순;이태선;최중환
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2004년도 추계학술대회 논문집
    • /
    • pp.1429-1433
    • /
    • 2004
  • Recently, a dangerous event occurred at the field industry and mechanical system. At developed by SUNGGOK corp. a R-L clutches of a small and high capacity serves safety device from a variety environment of mechanical system, it permits transmission of driving torque form input to output shaft in both directions of rotation, but restrains any feedback torque of the driven load from rotating the output shaft in either direction. This study was carried out to demonstrate through finite element methode and durability estimation for safety of the R-L clutches without sliding during the engagement process. As results, we organized about endurance test methode when applied rated torque.

  • PDF

유도전동기 효율개선을 위한 교류전압제어기의 디지탈제어 (The Digital Control of AC Voltage Controller for Efficiency Improvement of Induction Motor)

  • 권동빈;이승철;정승기
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1994년도 하계학술대회 논문집 A
    • /
    • pp.392-396
    • /
    • 1994
  • A method which improves the efficiency of induction motor by controlling the input voltage by the three phase AC voltage controller is studied at the sides of theory and practice. At first, the principle of decreasing the input power and improving the efficiency by adjusting the amplitude of the input voltage according to the load rate is shown. Secondarily, the mathematical model of the three phase AC voltage controller-induction motor system is drived to translate the dynamic characteristics. The validity of the dynamic model is verified by simulation. The new driving method is also proposed, which regulates the rated speed's driving by the speed estimation from the firing angle and the magnitude reverse induced-voltage information. As a result, the digital control system is constructed. Expermintal results show desirable characteristics of proposed system.

  • PDF

30AF 차단기 순시 Trip 동작 특성분석을 통한 저압차단기의 안전성 개선방안 (A Safety Improvement of Low Voltage Circuit-breakers through Analysis of Instantaneous Trip Characteristics of 30AF Circuit-Breakers)

  • 김주철;임정균;이상중
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.78-83
    • /
    • 2010
  • The domestic 30AFs that are currently being produced show many problems due to different instantaneous trip characteristics in case of short-circuit. The troubles may cause explosion by excessive short-circuit capacities and arc emission, which results in a wide range of blackout. The function and safety of the low voltage circuit breakers installed before the end load are very important. This paper presents an idea on the safety improvement of the low voltage circuit-breakers through the analysis of instantaneous trip characteristics of domestic 30AF circuit-breakers.

3MW 해상풍력용 영구자석 동기발전기 개발현황 (Status of 3 MW PM Synchronous Generator Development Project for Off-shore WECS)

  • 김동언;한홍식;이홍기;정영규;서형석;정진화
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.423-426
    • /
    • 2007
  • Pohang Wind Energy Research Center (PoWER-C) is developing a 3 MW Radial Flux Permanent Magnet (RFPM) Synchronous Generator for offshore Wind Energy Converter (WEC). The rotor rpm is 15.7 and the gear ratio is set to be 92.93. The nominal generator rpm at the rated load is about 1459. To reduce the switching loss in the power electronics, the maximum frequency is limited to 100 Hz. This requirement limits the number of pole to six or eight. Permanent magnet excitation is assumed for higher energy yield and higher efficiency. In this report, the requirements and the first efforts for the physics design are described.

  • PDF

운전조건을 고려한 고속 영구자석형 동기전동기의 회전자 손실 해석 (Analysis on the Rotor Losses in High-Speed Permanent Magnet Synchronous Motor Considering the Operating Condition)

  • 장석명;최장영;조한욱
    • 전기학회논문지
    • /
    • 제56권1호
    • /
    • pp.48-56
    • /
    • 2007
  • In this paper, the rotor losses in high-speed permanent synchronous motor (PMSM) considering the operating condition are discussed. In order to maintain the mechanical integrity of a high-speed permanent magnet machine rotor intended for high-speed operation, the rotor assembly is often retained within a stainless steel or Carbon-Fiber/Epoxy sleeve. The sleeve is exposed to fields produced by the stator from either the slotting or the mmf harmonics that are not synchronous with rotor losses. On the basis of analytical field analysis, the rotor losses are analyzed. In particular, the no-load, rated with air-cooled, and forced water cooled conditions are considered. The results are validated extensively by comparison with non-linear finite element method (FEM).

전도손실 저감 및 효율 상승을 위한 PWM DC-DC 컨버터의 특성 (Character of PWM DC-DC Converter for Conduction Loss Reduction and Efficiency Rise)

  • 김영문;김해재;김칠용;류재엽;김수욱
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 학술대회 논문집 전문대학교육위원
    • /
    • pp.125-127
    • /
    • 2007
  • Presented increase and so on of switch stress and switching dissipation and EMI that is happened in general PWM converter and in this study to solve problem the resonance energy return to life rate and new active snubber PWM converter because do maximization. Active snubber PWM converter that try adds auxiliary switch and resonance capacitor, diode to existing converter under all switching conditions turn on/off Minimised switching dissipation that occur. Reduced harmonic components absorbing station recovery electric current that happen to snubber diode inserting diode and resistance. And decreased peak current that is happened in auxiliary switch arranging resonance capacitor and inductor properly, Certified effect that efficiency rises about 2.5[%] more than existent PWM converter in rated load through an experiment.

  • PDF

IH-Jar용 Class-D 인버터의 새로운 PWM 출력 제어 기법 (A New PWM Power Control Scheme of Class-D Inverter for Induction Heating Jar Application.)

  • 최원석;박남주;이동윤;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2004년도 전력전자학술대회 논문집(2)
    • /
    • pp.519-523
    • /
    • 2004
  • In this paper, a simple power control scheme of Class-D inverter, which is varied duty cycle of fixed frequency to desired output power. It is more suitable and acceptable for high-frequency induction heating (IH) jar applications. The proposed control scheme has the advantages of not only wide power regulation range but also ease to control output power. Also it can achieve the stable and efficient Zero-Voltage-Switching (ZVS) in whole load range. The control principles of proposed method are described in detail and its validity is verified trough simulations results on 38.5kHz IGBT for induction heating rated on 1.6kW with constant frequency variable power.

  • PDF

On-line 시스템 모델과 파라메터 최적화 기법을 이용한 AVR의 최적 파라메터 튜닝 (AVR Parameter tuning with On-line System model using Parameter optimization technique)

  • 김중문;문승일
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 C
    • /
    • pp.1242-1244
    • /
    • 1999
  • AVR parameter tuning for voltage control of power system generators has generally been done with the open-circuit model of the synchronous generator. When the generator is connected on-line and operating at rated load conditions, the AVR operates in an entirely different environment from the open-circuit conditions. This paper describes a new method for AVR parameter tuning using optimization technique with on-line linearized system model. As this method considers not only the on-line models but also the off-line open-circuit models, AVR parameters tuned by this method can give the sufficiently stable performance at the open-circuit commissioning phase and give the desired performance at the operating conditions. Also this method estimates the optimum parameters for desired performance indices that are chosen for satisfying requirements in some practical applications, the performance of the AVR can satisfy the various requirements.

  • PDF