• Title/Summary/Keyword: Rated Power

Search Result 760, Processing Time 0.023 seconds

A Reliability Evaluation Model for the Power Devices Used in Power Converter Systems Considering the Effect of the Different Time Scales of the Wind Speed Profile

  • Ji, Haiting;Li, Hui;Li, Yang;Yang, Li;Lei, Guoping;Xiao, Hongwei;Zhao, Jie;Shi, Lefeng
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.685-694
    • /
    • 2016
  • This paper presents a reliability assessment model for the power semiconductors used in wind turbine power converters. In this study, the thermal loadings at different timescales of wind speed are considered. First, in order to address the influence of long-term thermal cycling caused by variations in wind speed, the power converter operation state is partitioned into different phases in terms of average wind speed and wind turbulence. Therefore, the contributions can be considered separately. Then, in regards to the reliability assessment caused by short-term thermal cycling, the wind profile is converted to a wind speed distribution, and the contribution of different wind speeds to the final failure rate is accumulated. Finally, the reliability of an actual power converter semiconductor for a 2.5 MW wind turbine is assessed, and the failure rates induced by different timescale thermal behavior patterns are compared. The effects of various parameters such as cut-in, rated, cut-out wind speed on the failure rate of power devices are also analyzed based on the proposed model.

Consumed-Power and Load Characteristics of Potato Harvesting Operation in Dry Field (건답에서 감자수확작업의 소요동력 및 부하특성)

  • Lee, Ju-Yeon;Hwang, Seok-Joon;Nam, Ju-Seok;Kim, Jeong-Gil
    • Journal of the Korean Society of Manufacturing Process Engineers
    • /
    • v.19 no.1
    • /
    • pp.89-99
    • /
    • 2020
  • This study analyzed the load and the consumed power characteristics of a potato harvesting operation in a dry field. The potato harvesting operation was performed using an underground crop harvester mounted on an agricultural tractor with a rated engine power of 23.7 kW. The rotational speeds and the torque of the engine output shaft, rear axle, and power take-off (PTO) shaft were measured under various working conditions. The load spectrum and the consumed power were analyzed using the measured data. The results show that the consumed power of the rear axle increased as the working speed increased, while that of the PTO shaft decreased. The consumed power of the engine output shaft showed a similar trend with that of the PTO shaft, but the torque deviation was larger in the load spectrum. The results of previous studies were used to compare herein the consumed power and the load characteristics of the harvesting, rotary, and plow operations in a dry field. PTO and tractive power were highly consumed in the plow and rotary operations, respectively. The consumed power of the PTO shaft and the rear axle in the harvesting operation were 29-41% and 18-23% of the engine power, respectively. Compared to those in the rotary and plow operations, the engine power was relatively evenly distributed to the PTO shaft and rear axle in the harvesting operation.

Application of Conservation Voltage Reduction using Automatic Voltage Regulator of Linear Voltage Control in Campus Microgrid with Power Consumption Reduction (에너지 절감을 고려한 캠퍼스 마이크로그리드에서 선형 전압제어 방식의 AVR을 이용한 CVR의 적용)

  • Lim, Il-Hyung;Lee, Myung-Hwan;Shin, Yong-Hark
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.66 no.7
    • /
    • pp.1039-1046
    • /
    • 2017
  • Campus microgrid is designed and built by considering not only power generation but also power consumption management as connected microgrid type because the main goal of the campus microgrid is to save power consumption costs. There are many functions to achieve the goal and they are mainly to use generation-based functions such as islanding operation for peak management and for emergency events. In power distribution operation, Conservation Voltage Reduction (CVR) is applied in order to reduce power consumption. The CVR is defined as a function for load consumption reduction by voltage reduction in order to reduce peak demands and energy consumption. However, application of CVR to microgrid is difficult because the microgrid cannot control a tap of transformer in a substation and the microgrid normally is not designed with phase modifying equipment like a step-voltage-regulator which can control voltage in power distribution system operation. In addition, an impact of the CVR is depended on load characteristics such as a normal load, a rated power, and synchronous motors. Therefore, this paper proposes an application of CVR using linear voltage control based AVR in campus microgrid with power consumption reduction considering characteristics of load and component in the microgrid. The proposed system can be applied to each buildings by a configuration of power distribution cables; and the application results and CVR factor are presented in this paper.

Design of Power Supply for Green PC using Low Voltage High Current LLC Resonant Converter (저전압 대전류 LLC 공진형 컨버터를 이용한 그린 PC용 전원공급장치 설계)

  • Yoo, Young-Do;Kim, In-Dong;Nho, Eui-Cheol;Ryu, Myung-Hyo;Baek, Ju-Won
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.19 no.3
    • /
    • pp.211-219
    • /
    • 2014
  • This paper proposes a low voltage high current LLC resonant converter for Green PC. Green PC is composed of a lot of blade PCs, and it is a centralized system to manage them in computer center. Green PC should require that its power supplies have several characteristics such as low output voltage, high output current, and high power conversion efficiency. Conventional PSFB (Phase Shift Full Bridge) converter is usually used as DC/DC converter for computer power supply because it has high power conversion efficiency thanks to ZVS (Zero Voltage Switching) operation under middle and high load conditions. However, this converter has some problems such as large switching noise and limitation of ZVS operation under light load condition. In order to improve the performance of power supply for Green PC, a new power supply using popular high efficiency LLC resonant converter for low voltage and high current application is proposed in this paper. The proposed power supply has ZVS capability over the entire load range, thus resulting in good efficiency and high switching frequency. Experimental results verify the performance of the proposed power supply for Green PC using 2[kW] (19[V], 105[A]) rated prototype converter.

Power Smoothening Control of Wind Farms Based on Inertial Effect of Wind Turbine Systems

  • Nguyen, Thanh Hai;Lee, Dong-Choon;Kang, Jong-Ho
    • Journal of Electrical Engineering and Technology
    • /
    • v.9 no.3
    • /
    • pp.1096-1103
    • /
    • 2014
  • This paper proposes a novel strategy for attenuating the output power fluctuation of the wind farm (WF) in a range of tens of seconds delivered to the grid, where the kinetic energy caused by the large inertia of the wind turbine systems is utilized. A control scheme of the two-level structure is applied to control the wind farm, which consists of a supervisory control of the wind farm and individual wind turbine controls. The supervisory control generates the output power reference of the wind farm, which is filtered out from the available power extracted from the wind by a low-pass filter (LPF). A lead-lag compensator is used for compensating for the phase delay of the output power reference compared with the available power. By this control strategy, when the reference power is lower than the maximum available power, some of individual wind turbines are operated in the storing mode of the kinetic energy by increasing the turbine speeds. Then, these individual wind turbines release the kinetic power by reducing the turbine speed, when the power command is higher than the available power. In addition, the pitch angle control systems of the wind turbines are also employed to limit the turbine speed not higher than the limitation value during the storing mode of kinetic energy. For coordinating the de-rated operation of the WT and the storing or releasing modes of the kinetic energy, the output power fluctuations are reduced by about 20%. The PSCAD/EMTDC simulations have been carried out for a 10-MW wind farm equipped with the permanent-magnet synchronous generator (PMSG) to verify the validity of the proposed method.

Effect the I-T curve and electrical characteristic of fuse elements by plated tin thickness (주석 도금 두께에 따른 퓨즈 가용체의 I-T 커브 및 전기적 특성의 영향)

  • Jin, Sang-Jun;Kim, Eun-Min;Youn, Jae-Seo;Lee, Ye-Ji;Noh, Seong-Yeo
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.19 no.6
    • /
    • pp.80-87
    • /
    • 2018
  • In recent years, due to the spread of various renewable energy power sources and the pursuit of high efficiency and low-power consumption, not only trends in the electric power industry but also the consumption, control methods, and characteristics are diversified. However, in this diversified electric power industry, the fuse (which is the core part responsible for safety) has not developed significantly in classical operation mode, and thus, fires continue to occur. In this paper, the effects of low melting-point metal plating and high melting-point metal plating on operating characteristics and IT curve movement of the fuse are investigated in a cartridge fuse, which is a classic fuse manufacturing method. The effects of plating on the thickness of the fuse are investigated, and various operating characteristics of the fuse are implemented. In addition, it is suggested that the plating of the low melting-point metal moves the rated current line of the fuse to a low rating, and moves operating characteristics to characteristics of delay operation. It is possible to design various operating characteristics using this characteristic.

Turbine Cycle Thermal Performance Analysis of Advanced Power Reactor 1400 (신형경수로(APR1400)의 터빈 싸이클 열성능 분석)

  • Jeong, Dae-Yul;Lim, Hyuk-Soon;Jeong, Dae-Wok;Heo, Gyun-Young
    • Proceedings of the KSME Conference
    • /
    • 2001.06d
    • /
    • pp.343-347
    • /
    • 2001
  • Advanced Pressurized Reactor 1400(APR-1400), which is a standard evolutionary advanced light water reactor(ALWR), has been developed from 1992 as one of long-term Government Project(G-7). The APR-1400 is designed to operate at the rated output of 4000MWt to produce an electric power output of around 1450MWe. The balance of plant (BOP) for the secondary system consists of main steam, feedwater, condensate, turbine generator and auxiliary system. In this paper, we describe the major design features of secondary component, balance of plant configuration, and then the turbine cycle thermal performance evaluation using PEPSE code.

  • PDF

A Novel Flux Calculator for the Field Oriented Control of an Induction Motor without Speed Sensors (속도센서 없는 유도전동기 자속기준제어를 위한 새로운 자속 연산기)

  • 김경서
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.3 no.2
    • /
    • pp.125-130
    • /
    • 1998
  • This paper describes a novel flux calculator for the estimation of real rotor flux angle which is indispensable to the field oriented control of induction motors. A pure integrator is used to estimate the real rotor flux precisely from voltage and current information. The proposed flux calculator adopts the new drift compensation method to overcome the drift problem of pure integrator. The motor speed is calculated using estimated flux angle and estimated slip frequency. The performance of this approach is verified through the experiment. The experimental results shows stable operation of proposed system even below 1/100 of rated speed.

A Novel ZVZCS PWM Boost Converter (새로운 ZVZCS PWM Boost 컨버터)

  • Kim T.W.;Chin K.H.;Kang A.J.;Kim H.S.
    • Proceedings of the KIPE Conference
    • /
    • 2003.07a
    • /
    • pp.327-331
    • /
    • 2003
  • This paper proposes a novel ZVZCS-PWM Boost Converter. It enables the main switch to be turned on and off with both zero voltage and zero current and the auxiliary switch to be turned on and off with ZCS, the rectify diode to be turned on and off with ZVS. Moreover, this converter is suitable for not on]y minority carrier device but also majority carrier device. The auxiliary resonant circuit of the proposed boost converter is placed out the main power path, therefore, there are no voltage/current stresses on the main switch and diode. The operation of the proposed boost converter is explained and analyzed theoretical and experimentally, from a prototype operating at 100kHz, with an input voltage rated at 50V.

  • PDF

On the Analysis of Vertical-axis Wind Rotor (수직축 풍력발전기의 해석에 관하여)

  • ;;Lee, Chung-Oh
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.3 no.2
    • /
    • pp.60-67
    • /
    • 1979
  • Aerodynamic forces acting on a curved blade are computed theoretically taking into account the variation of wind speed over the blade to investigate the performance of a vertical axis wind rotor. It is shown that the rotor does not self start at the rated wind speed without a supplementary starting device and that most of the power output is contributed by the central portion of the rotor, and the use of spoilers for limiting the maximum rotational speed is needed for safety. It is also shown that provision of skew angle to the blade does not improve the starting characterstics and only reduces the maximum power output. The effects of geometric variables such as skew angle, blade solidity and ratio of the rotor height to diameter are also discussed.