• Title/Summary/Keyword: Rated Power

Search Result 760, Processing Time 0.028 seconds

A Study on the Configuration Design and the Performance Analysis of the 20kW HAWT based on BEMT (BEMT를 적용한 20kW 수평축 풍력터빈 형상설계 및 성능해석)

  • Kang, Ho-Keun;Nam, Cheong-Do;Lee, Young-Ho;Kim, Beom-Seok
    • Journal of Advanced Marine Engineering and Technology
    • /
    • v.30 no.6
    • /
    • pp.669-676
    • /
    • 2006
  • The optimum design and the performance analysis software called POSEIDON for the HAWT (Horizontal Axis Wind Turbine) is developed by use of BEMT, which is the standard computational technique for prediction of power curves of wind turbines. The Prandtl's tip loss theory is adopted to consider the blade tip loss. The lift and the drag coefficient of S-809 airfoil are predicted via X-FOIL and the post stall characteristics of S-809 also are estimated by the Viterna's equations.$^{[13]}$ All the predicted aerodynamic characteristics are fairly well agreed with the wind tunnel test results. performed by Sommers in Delft university of technology. The rated power of the testing rotor is 20kW(FIL-20) at design conditions. The experimental aerodynamic parameters and the X-FOIL data are used for the power Prediction of the FIL-20 respectively The comparison results shows good agreement in power prediction.

Design and Implementation of PRA for a Power Supply of Electrical Vehicle (전기자동차의 전력공급을 위한 PRA 설계 및 구현)

  • Chai, Yong-Yoong
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.11 no.7
    • /
    • pp.653-658
    • /
    • 2016
  • As this paper is related to the relay and its driving control method, it explains about the relay which connects or interrupts the DC high voltage battery's power to drive the electric car's inverter. The paper suggests a sub-relay which prevents strong sparks from relay's contact point when the relay connects to the DC high voltage battery and also compensates for the increasing internal resistance value that is caused by deterioration at contact point. The relay's rated power is approximately 10KW and the relay's electric property has been verified through electrical instantaneous power short test, etc.

A Study on Variable Speed Generation System with Energy Saving Function

  • Dugarjav, Bayasgalan;Lee, Sang-Ho;Han, Dong-Hwa;Lee, Young-Jin;Choe, Gyu-Ha
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.1
    • /
    • pp.137-143
    • /
    • 2013
  • This paper presents development of variable speed generation (VSG) system with energy saving function. The rubber tyred gantry crane (RTGC) requires the power from diesel-engine. Significant fuel savings by reducing the engine speed can be achieved, because all of operation modes except hoisting are required lower power than rated value of engine. When low speed operation output voltage of generator is decrease until acceptable range of motor driver inverters and auxiliary load supplier. According to power demand engine speed is varying from 20 to 60Hz, and voltage is varying between 210Vac and 480Vac. When idle mode or low power operation dc/dc converter operates by constant output voltage control and inverters dc site voltage is compensated by it. This paper proposed 3-phase interleaved boost converter which has the same structure as the commercially available 3-phase inverter and current sharing capability. 400kW interleaved converter is designed and a performance of converter is evaluated through several experiments with a RTGC system. Energy saving VSG system can cut down fuel consumption by 36% and 21.3% at idle and unidirectional load operations.

Field Adaptability Test for the Full Load Rejection of Nuclear Turbine Speed Controllers using Dynamic Simulator

  • Choi, In-Kyu;Kim, Jong-An;Woo, Joo-Hee
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.23 no.7
    • /
    • pp.67-74
    • /
    • 2009
  • This paper describes the speed control functions of the typical steam turbine speed controllers and the test results of generator load rejection simulations. The goal of the test is to verify the speed controller's ability to limit the steam turbine's peak speed within a predetermined level in the event of generator load loss. During normal operations, the balance between the driving force of the steam turbine and the braking force of the generator load is maintained and the speed of the turbine-generator is constant. Upon the generator's load loss, in other word, the load rejection, the turbine speed would rapidly increase up to the peak speed at a fast acceleration rate. It is required that the speed controller has the ability to limit the peak speed below the overspeed trip point, which is typically 110[%] of rated speed. If an actual load rejection occurs, a substantial amount of stresses will be applied to the turbine as well as other equipments, In order to avoid this unwanted situation, not an actual test but the other method is necessary. We are currently developing the turbine control system for another nuclear power plant and have plan to do the simulation suggested in this paper.

A High-Efficiency High Step-Up Interleaved Converter with a Voltage Multiplier for Electric Vehicle Power Management Applications

  • Tseng, Kuo-Ching;Chen, Chun-Tse;Cheng, Chun-An
    • Journal of Power Electronics
    • /
    • v.16 no.2
    • /
    • pp.414-424
    • /
    • 2016
  • This paper proposes a novel high-efficiency high-step-up interleaved converter with a voltage multiplier, which is suitable for electric vehicle power management applications. The proposed interleaved converter is capable of achieving high step-up conversion by employing a voltage-multiplier circuit. The proposed converter lowers the input-current ripple, which can extend the input source's lifetime, and reduces the voltage stress on the main switches. Hence, large voltage spikes across the main switches are alleviated and the efficiency is improved. Finally, a prototype circuit with an input voltage of 24 V, an output voltage of 380 V, and an output rated power of 1 kW is implemented and tested to demonstrate the functionality of the proposed converter. Moreover, satisfying experimental results are obtained and discussed in this paper. The measured full-load efficiency is 95.2%, and the highest measured efficiency of the proposed converter is 96.3%.

A CMOS Stacked-FET Power Amplifier Using PMOS Linearizer with Improved AM-PM

  • Kim, Unha;Woo, Jung-Lin;Park, Sunghwan;Kwon, Youngwoo
    • Journal of electromagnetic engineering and science
    • /
    • v.14 no.2
    • /
    • pp.68-73
    • /
    • 2014
  • A linear stacked field-effect transistor (FET) power amplifier (PA) is implemented using a $0.18-{\mu}m$ silicon-on-insulator CMOS process for W-CDMA handset applications. Phase distortion by the nonlinear gate-source capacitance ($C_{gs}$) of the common-source transistor, which is one of the major nonlinear sources for intermodulation distortion, is compensated by employing a PMOS linearizer with improved AM-PM. The linearizer is used at the gate of the driver-stage instead of main-stage transistor, thereby avoiding excessive capacitance loading while compensating the AM-PM distortions of both stages. The fabricated 836.5 MHz linear PA module shows an adjacent channel leakage ratio better than -40 dBc up to the rated linear output power of 27.1 dBm, and power-added efficiency of 45.6% at 27.1 dBm without digital pre-distortion.

The Damage of Microcontroller Devices due to Coupling Effects under High Power Electromagnetic Wave by Magnetron (고출력 전자기파의 커플링 효과에 의한 마이크로 컨트롤러의 손상)

  • Hong, Joo-Il;Hwang, Sun-Mook;Huh, Chang-Su
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.12
    • /
    • pp.2263-2268
    • /
    • 2008
  • We investigated the malfunction and destruction characteristics of microcontroller devices under high power electromagnetic(HPEM) wave by magnetron. HPEM was rated at a microwave output of 0 to 1,000 W, at a frequency of 2,450${\pm}$50 MHz and was radiated from the open-ended standard rectangular waveguide(WR-340) to free space. The influence of different reset-, clock-, data-, and power supply-line lengths has been tested. The variation of the line length was done with flat cables. The susceptibility of the tested microcontroller devices was in general much influenced by clock-, reset-, and power supply-line length, little influenced by data-line length. Further the line length was increased, the malfunction threshold was decreased as expected, because more energy couples to the devices. The surfaces of the destroyed microcontroller devices were removed and the chip conditions were investigated with microscope. The microscopic analysis of the damaged devices showed component and bondwire destructions such as breakthroughs and melting due to thermal effects. The obtained results are expected to provide fundamental data for interpreting the combined mechanism of microcontroller devices in an intentional microwave environment.

Centrifugal Clutch Design for Unmanned Helicopter - Simulation of Optimal Factors - (농용 무인헬리콥터의 원심클러치 설계 - 최적 설계치의 시뮬레이션 -)

  • Lee, J.H.;Koo, Y.M.
    • Journal of Biosystems Engineering
    • /
    • v.34 no.2
    • /
    • pp.89-94
    • /
    • 2009
  • Aerial application using an agricultural unmanned helicopter was suggested for an alternative against current pesticide application methods. Centrifugal clutches play important roles in the performance and safety of the helicopter operation. A previous study analyzed and verified the power transfer theory of the guide type centrifugal clutch. Based on the clutch theory, optimal designs of the clutch became possible and feasible using a simulation method. Design criteria of the clutch were the power transfer capacity of 24.66 kW(33.5 PS) at the rated engine speed and the engaging range speed of 3,000${\sim}$3,500 rpm. Various designs were accomplished using the simulation. An optimal clutch was simulated by determining the values of spring constant and mass of friction sector, which were 94,700 N/m and 123.7 g, respectively. The design performed the power capacity of 24.86 kW(33.8 PS) and engagement speed of 3,069 rpm, meeting the design criteria. Using the designed clutch, an efficient transfer of the power would be possible for the unmanned agricultural helicopter.

Islanding Detection Method for Inverter-based Distributed Generation Systems using a Signal Cross-correlation Scheme

  • Bae, Byung-Yeol;Jeong, Jong-Kyou;Lee, Ji-Heon;Han, Byung-Moon
    • Journal of Power Electronics
    • /
    • v.10 no.6
    • /
    • pp.762-768
    • /
    • 2010
  • This paper describes the development of a new islanding detection method for inverter-based distributed generation systems, which uses a signal cross-correlation scheme between the injected reactive current and the power frequency deviation. The proposed method injects 1% of the reactive current to the rated current which brings about a negligible degradation of the power quality. It discriminates the islanding state, when the calculated cross-correlation index is larger than 0.5. The operational feasibility was verified through computer simulations with PSCAD/EMTDC software and experimental research with a hardware prototype. The proposed method can detect the islanding state without degrading the power quality at the point of common connection. Further study is required to overcome the cancellation of the injected reactive current from multiple distributed generation units interconnected with the utility grid.

An Adaptive Maximum Power Point Tracking Scheme Based on a Variable Scaling Factor for Photovoltaic Systems (태양광 시스템을 위한 가변 조정계수 기반의 적응형 MPPT 제어 기법)

  • Lee, Kui-Jun;Kim, Rae-Young;Hyun, Dong-Seok;Lim, Chun-Ho;Kim, Woo-Chull
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.17 no.5
    • /
    • pp.423-430
    • /
    • 2012
  • An adaptive maximum power point tracking (MPPT) scheme employing a variable scaling factor is presented. A MPPT control loop was constructed analytically and the magnitude variation in the MPPT loop gain according to the operating point of the PV array was identified due to the nonlinear characteristics of the PV array output. To make the crossover frequency of the MPPT loop gain consistent, the variable scaling factor was determined using an approximate curve-fitted polynomial equation about linear expression of the error. Therefore, a desirable dynamic response and the stability of the MPPT scheme were maintained across the entire MPPT voltage range. The simulation and experimental results obtained from a 3 KW rated prototype demonstrated the effectiveness of the proposed MPPT scheme.