• Title/Summary/Keyword: Rate Test

Search Result 13,532, Processing Time 0.042 seconds

A Survey Study on Occurance Rate, Knowledge and Self-care Behavior of diabetes for the Elderly who are Attending a Villa House for the Aged. (서울시 일부지역 노인정 노인의 당뇨병 출현정도와 당뇨병에 대한 지식 및 질병관리 상태에 관한 연구)

  • Ro Kook Hee
    • Journal of Korean Public Health Nursing
    • /
    • v.1 no.1
    • /
    • pp.17-31
    • /
    • 1987
  • This study was carried out for the age 60years over who are attending a villa house for the aged during day time. The purpose of this study was to measure occurance rate of Diabetes by self cognitiveness about their disease of Diabetes; by result of urine test tape test and a questionaire study and self-care behavior about Diabetes. The results of the study are summarized as follow: 1. General Characteristics of the suryeyed. The population studied consisted of 143 males and 256 females comprising $73.9\%$ of the total population registered at the elderly villa house at the time of the study. The mean age group of the study was 70-79 years; educational level $77.2\%$ was below than primary education. 2. The results of Diabetes study. The number of cases who were self-recognized about their Diabetes were 19; 8 males and 11 females. The number of urine sugar positive cases was 35; 19 males and 16 females. The consistency rate of positive urine sugar test was $93.5\%$ An average degree of the results of knowledge test about Diabetes was 1. 4 point. When the correct 1 item was given 1 point for the 6 item of questions. Among 19 cases of self-recognized disease group an average degree of the knowledge test results was 2. 3 point and among the 35 cases of the urine test positive group an average degree of the knowledge test results was 1. 7 point. The average degree of self -care behavior about Diabetes was 1. 6 point when measued 3 point scale on the self-care behavior for the 7 item of questions.

  • PDF

Study on Crashworthiness of Icebreaker Steel: Part I Steel Properties (쇄빙선 강재의 내충격 특성에 관한 실험적 연구: 제1부 강재 특성)

  • Noh, Myung-Hyun;Lee, Jae-Yik;Park, Sung-Ju;Choung, Joonmo
    • Journal of Ocean Engineering and Technology
    • /
    • v.30 no.4
    • /
    • pp.268-276
    • /
    • 2016
  • This paper presents a study on the crashworthiness of the scaled-down stiffened panels used on a Korean icebreaker. In order to validate the crashworthiness of the panels, this paper provides various mechanical properties such as the results of a CVN test, quasi-static tensile test, and high-speed tensile test at arctic temperatures. Two types of steels (EH32 and FH32) were chosen for the material tests. CVN tests revealed that the two steels were equivalent up to −60℃ in terms of their impact energy absorption capacity. However, the toughness of FH32 was significantly superior to that of EH32. EH32 showed slightly higher flow stresses at all temperature levels compared to FH32. The improvement ratios of the yield strengths, tensile strengths, plastic hardening exponents, etc. for FH32, which were obtained from quasi-static tensile tests, showed an apparent ascending tendency with a decrease in temperature. Dynamic tensile test results were obtained for the two temperatures levels of 20℃ and −60℃ with two plastic strain rate levels of 1 s−1 and 100 s−1. A closed form empirical formula proposed by Choung et al. (2011;2013) was shown to be effective at predicting the flow stress increase due to a strain rate increase.

A Study on Current Characteristics Based on Design and Performance Test of Current Generator of KRISO's Deep Ocean Engineering Basin

  • Kim, Jin Ha;Jung, Jae Sang;Hong, Seok Won;Lee, Chun Ju;Lee, Yong Guk;Park, Il Ryong;Song, In Haeng
    • Journal of Ocean Engineering and Technology
    • /
    • v.35 no.6
    • /
    • pp.446-456
    • /
    • 2021
  • To build an environment facility of a large-scale ocean basin, various detailed reviews are required, but it is difficult to find data that introduces the related research or construction processes on the environment facility. The current generator facility for offshore structure safety evaluation tests should be implemented by rotating the water of the basin. However, when the water in the large basin rotates, relatively large flow irregularities may occur and the uniformity may not be adequate. In this paper, design and review were conducted to satisfy the performance goals of the DOEB through computational numerical analysis on the shape of the waterway and the flow straightening devices to form the current in the large tank. Based on this, the head loss, which decreases the flow rate when the large tank water rotates through the water channel, was estimated and used as the pump capacity (impeller) design data. The impeller of the DOEB current generator was designed through computational numerical analysis (CFD) based on the lift surface theory from the axial-type impeller shape for satisfying the head loss of the waterway and maximum current velocity. In order to confirm the performance of the designed impeller system, the flow rate and flow velocity performance were checked through factory test operation. And, after installing DOEB, the current flow rate and velocity performance were reviewed compare with the original design target values. Finally, by measuring the current velocity of the test area in DOEB formed through the current generator, the spatial current distribution characteristics in the test area were analyzed. Through the analysis of the current distribution characteristics of the DOEB test area, it was confirmed that the realization of the maximum current velocity and the average flow velocity distribution, the main performance goals in the waterway design process, were satisfied.

Effects of particle size and loading rate on the tensile failure of asphalt specimens based on a direct tensile test and particle flow code simulation

  • Q. Wang;D.C. Wang;J.W. Fu;Vahab Sarfarazi;Hadi Haeri;C.L. Guo;L.J. Sun;Mohammad Fatehi Marji
    • Structural Engineering and Mechanics
    • /
    • v.86 no.5
    • /
    • pp.607-619
    • /
    • 2023
  • This study, it was tried to evaluate the asphalt behavior under tensile loading conditions through indirect Brazilian and direct tensile tests, experimentally and numerically. This paper is important from two points of view. The first one, a new test method was developed for the determination of the direct tensile strength of asphalt and its difference was obtained from the indirect test method. The second one, the effects of particle size and loading rate have been cleared on the tensile fracture mechanism. The experimental direct tensile strength of the asphalt specimens was measured in the laboratory using the compression-to-tensile load converting (CTLC) device. Some special types of asphalt specimens were prepared in the form of slabs with a central hole. The CTLC device is then equipped with this specimen and placed in the universal testing machine. Then, the direct tensile strength of asphalt specimens with different sizes of ingredients can be measured at different loading rates in the laboratory. The particle flow code (PFC) was used to numerically simulate the direct tensile strength test of asphalt samples. This numerical modeling technique is based on the versatile discrete element method (DEM). Three different particle diameters were chosen and were tested under three different loading rates. The results show that when the loading rate was 0.016 mm/sec, two tensile cracks were initiated from the left and right of the hole and propagated perpendicular to the loading axis till coalescence to the model boundary. When the loading rate was 0.032 mm/sec, two tensile cracks were initiated from the left and right of the hole and propagated perpendicular to the loading axis. The branching occurs in these cracks. This shows that the crack propagation is under quasi-static conditions. When the loading rate was 0.064 mm/sec, mixed tensile and shear cracks were initiated below the loading walls and branching occurred in these cracks. This shows that the crack propagation is under dynamic conditions. The loading rate increases and the tensile strength increases. Because all defects mobilized under a low loading rate and this led to decreasing the tensile strength. The experimental results for the direct tensile strengths of asphalt specimens of different ingredients were in good accordance with their corresponding results approximated by DEM software.

A Study of Valve-train Life Time Estimate in Engine Durability Test (2) (엔진내구시험을 통한 Valve Train 수명예측에 관한 연구 (2))

  • Kim, Jaejin;Lee, Hwanhui;Myung, Wanghee;Min, Byengdu
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.22 no.3
    • /
    • pp.75-80
    • /
    • 2014
  • In previous study, make an attempt to estimate exhaust valve seat and seat-ring wear acceleration factor for engine durability test with measuring and consideration of wear mechanism. But found abnormal initial wear rate in exhaust valve seat-ring. And have to improve exhaust valve seat-ring wear rate for reliability reason, because next GDI/Turbo engine is based on this engine and GDI/Turbo engine have higher combustion pressure and higher thermal load. In this study, Trying to find the cause of abnormal wear factor, improve valve-train durability by change specification & design of parts and verify variant parts for improving durability of valve-train. And then I would like to propose a design guide line of valve-train system in a reliability point of view, besides make a complement of previous study.

Prevalence of toxoplasma antibody in swine by microplate latex agglutination test in Kyeongnam district (Latex 응집반응에 의한 경남중부지역 돼지의 톡소플라즈마병 항체조사)

  • Lee, Byung-hoon;Kim, Cha-yong;Suh, Myung-deuk
    • Korean Journal of Veterinary Research
    • /
    • v.33 no.2
    • /
    • pp.263-268
    • /
    • 1993
  • This study was conducted to detect the serum antibody of toxoplasma in swine from breeding-pig, rearing-pig farm and slaughtered pig in abattior by latex agglutination(LA) test. The perfomance of LA test was carried out with commercial Toxo-MT kit(Eiken Chemical Co.)by Tsubota and Ozawa's method. The cut-off titer of positive and negative reactions by Toxo-MT antigen used in this experiment was determined as the serum titer of 1 : 32. Positive rate of toxoplasma antibody from the total of 823 serum samples by LA test was 17.0%(140 cases). And positive rates of toxoplasma antibody against serum samples of 194 from breeding-pig farm, 273 from rearing-pig farm and 356 from abattior were 91 cases(46. 9%), 23 cases(8.4%) and 26 cases(7.3%), respectively. The distributions of serum antibody titers in 823 test sera by LA test were shown 51 cases(36.3%) in 1:32, 40(28.6%) in 1:64, 17(12.1%) in 1:128, 14(10.0%) in 1:256, 3(2.1%) in 1:512, 5(3.6%) in 1:1024 and 3(2.1%) in 1:2048. The ranges of positive rate from the sera in each group of breeding-pig farms were 20~61.9%.

  • PDF

Respirometry for the Assessment of Organics Biodegradability in Municipal Wastewater: II. Active Biomass and NUR (호흡률법에 의한 하수의 생분해 특성 평가: II. 활성미생물 및 NUR)

  • Kim, Dong Han;Kim, Gyu Dong;Chung, Tai Hak
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.113-120
    • /
    • 2004
  • The biodegradability of organics has become essential for the design and modeling of a biological nutrient removal process. Respirometry for the batch test just with wastewater has been conducted to estimate active biomass and readily biodegradable organics in municipal wastewater simultaneously. Municipal wastewater contains significant active biomass, which is estimated about 17% of COD. Compared to the batch test seeded with sludge, the batch test just with wastewater represents a little higher readily biodegradable organics. This might be due to the different environment of the logarithmic growth of active biomass. The nitrate uptake rate test has been also performed for the estimation of the readily biodegradable organics. The nitrate uptake rate test results in a little higher readily biodegradable organics compared to the batch test seeded with sludge and similar organics compared to the batch test just with wastewater. This might be caused by the different sludge of a sequencing batch reactor process. Taking the result of the previous research into account, the readily biodegradable, slowly biodegradable, active biomass, soluble inert, and particulate inert organics are estimated about 11%, 49%, 17%, 11%, and 12% of COD, respectively.

Performance Test of Vitiated Air Heater with High Temperature and High Pressure (고온 고압 공기가열기 성능시험)

  • Lee, Jungmin;Na, Jaejeoung;Hong, Yunky;Kim, Jeongwoo
    • Journal of the Korean Society of Propulsion Engineers
    • /
    • v.22 no.4
    • /
    • pp.68-75
    • /
    • 2018
  • This study presents the performance test results and the analyses of the vitiated air heater with high temperature and high pressure. In the performance test, four test conditions and three rake measurement conditions were implemented. In the results of the performance test, the vitiated air heater met targets of temperature and flow rate, and the performance with maximum temperature of 2000 K and maximum combustion pressure of 40 bar was confirmed. Flow rate of provided methane increased 36% more than what was calculated, and 19.6% difference was displayed between measured temperature and theoretically calculated temperature.

Successful Motor Evoked Potential Monitoring in Cervical Myelopathy : Related Factors and the Effect of Increased Stimulation Intensity

  • Shim, Hyok Ki;Lee, Jae Meen;Kim, Dong Hwan;Nam, Kyoung Hyup;Choi, Byung Kwan;Han, In Ho
    • Journal of Korean Neurosurgical Society
    • /
    • v.64 no.1
    • /
    • pp.78-87
    • /
    • 2021
  • Objective : Intraoperative neurophysiological monitoring (IONM) has been widely used during spine surgery to reduce or prevent neurologic deficits, however, its application to the surgical management for cervical myelopathy remains controversial. This study aimed to assess the success rate of IONM in patients with cervical myelopathy and to investigate the factors associated with successful baseline monitoring and the effect of increasing the stimulation intensity by focusing on motor evoked potentials (MEPs). Methods : The data of 88 patients who underwent surgery for cervical myelopathy with IONM between January 2016 and June 2018 were retrospectively reviewed. The success rate of baseline MEP monitoring at the initial stimulation of 400 V was investigated. In unmonitorable cases, the stimulation intensity was increased to 999 V, and the success rate final MEP monitoring was reinvestigated. In addition, factors related to the success rate of baseline MEP monitoring were investigated using independent t-test, Wilcoxon rank-sum test, chi-squared test, and Fisher's exact probability test for statistical analysis. The factors included age, sex, body mass index, diabetes mellitus, smoking history, symptom duration, Torg-Pavlov ratio, space available for the cord (SAC), cord compression ratio (CCR), intramedullary increased signal intensity (SI) on magnetic resonance imaging, SI length, SI ratio, the Medical Research Council (MRC) grade, the preoperative modified Nurick grade and Japanese Orthopedic Association (JOA) score. Results : The overall success rate for reliable MEP response was 52.3% after increasing the stimulation intensity. No complications were observed to be associated with increased intensity. The factors related to the success rate of final MEP monitoring were found to be SAC (p<0.001), CCR (p<0.001), MRC grade (p<0.001), preoperative modified Nurick grade (p<0.001), and JOA score (p<0.001). The cut-off score for successful MEP monitoring was 5.67 mm for SAC, 47.33% for the CCR, 3 points for MRC grade, 2 points for the modified Nurick grade, and 12 points for the JOA score. Conclusion : Increasing the stimulation intensity could significantly improve the success rate of baseline MEP monitoring for unmonitorable cases at the initial stimulation in cervical myelopathy. In particular, the SAC, CCR, MRC grade, preoperative Nurick grade and JOA score may be considered as the more important related factors associated with the success rate of MEP monitoring. Therefore, the degree of preoperative neurological functional deficits and the presence of spinal cord compression on imaging could be used as new detailed criteria for the application of IONM in patients with cervical myelopathy.

Effect of Foot Reflexology on Patient's Pain and Mood Following a Mastectomy (발 반사마사지가 유방암 환자의 수술 후 통증 및 기분에 미치는 효과)

  • Chang, Hwa-Kyoung
    • Asian Oncology Nursing
    • /
    • v.1 no.2
    • /
    • pp.204-216
    • /
    • 2001
  • The purpose of this study was to test the effects of foot reflexology on pain and mood in patients who have just had a mastectomy. The research design was a nonequivalent control group, non-synchronized design. The participants for this study were 28 patients with breast cancer on first or second day after mastectomy surgery. The first 12 patients were assigned to the control group and the second 16 to the experimental group. The study was conducted from October 28, 2001 to December 22, 2001 on a surgical unit of Y Medical Center in Seoul, Korea. Pain intensity, blood pressure, pulse rate and mood were measured as dependent variables. The instrument used for pain intensity and mood was a 10 cm visual analogue scale. Cronbach alpha for this study was .70. For the experimental group pre and post tests were done immediately before and 15 minutes after completion of foot reflexology. Foot reflexology was performed once for 20 minutes. After the pretest, patients in the control group were instructed to have a quiet time for a 35 minute period and then the post-test was done. The number of participants was small so the data were analyzed by Mann-Whitney U test, and Wilcoxon signed ranks test. The results of this study are as follow : 1. In the experimental group there were significant decreases between the pre and post tests for pain intensity (z=-3.47, p<.001), diastolic blood pressure (z=-2.67, p<.01) and pulse rate (z=-3.44, p<.001) but there was no difference between the two groups on the post test. 2. The systolic blood pressure, diastolic blood pressure and pulse rate were also not significantly different between the experimental group and the control group on the post test. 3. The mood score was significantly improved after foot reflexology(z=-3.52, p=.000) and the difference between the two groups was also significant (u=49.0, p=.03). In conclusion, there was a statistically significant difference in mood between the two groups, but no difference for pain intensity, blood pressure, or pulse rate. However, there were significant differences between the pretest and post-test for pain intensity, diastolic blood pressure and pulse rate in the experimental group. On the basis of the above findings, this study suggests that foot reflexology can be an effective method of relieving pain and improving mood in clinical practice in women who have had mastectomy surgery.

  • PDF