• Title/Summary/Keyword: Rate Test

Search Result 13,532, Processing Time 0.04 seconds

A Fact-finding Research Exercise into the Handling Abilities of Experimental Apparatus by Elementary School Students (초등학생의 실험 기구 조작 능력에 대한 실태 조사)

  • Park, Jae-Won;Yoon, Sang-Mi;Won, Jeong-Ae;Paik, Seoung-Hey
    • Journal of Korean Elementary Science Education
    • /
    • v.26 no.2
    • /
    • pp.161-170
    • /
    • 2007
  • This study aims at helping us improve the methods used to teach elementary school students how to handle experimental apparatus by examining their manual skills and their understanding of the alcohol lamp, spuit and thermometer. To evaluate their ability to handle each experimental apparatus, a practical skills test and knowledge evaluation sheets were developed. The evaluation was carried out with 270 students from 2 classes each in the 3rd, 4th, 5th and 6th grade of D Elementary School located in Daejeon City. For their handling ability of the alcohol lamp, the results for the practical skills test showed that the students had a very low ability in placing objects in the center of the apparatus for safe use and also in adjusting the height of the trivet to place objects so that they contact the outer flames correctly. For the spuit, the pass rate of the skills test was generally low in regards to how students should grasp a spuit and the timing and method of depressing the rubber part before dipping it into liquid. For the thermometer, on the other hand, the pass rate was relatively high in every respect. The knowledge evaluation results for the use of experimental apparatus showed a very high rate of correct answers for alcohol lamps and thermometers. The test results for spoils also produced a relatively high rate of correct answers, with the exception of the test item regarding the way that students should grasp them.

  • PDF

Optimum Harvest Time for High Quality Seed Production of Sweet and Super Sweet Corn Hybrids

  • Lee Suk Soon;Yun Sang Hee;Seo Jung Moon
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.49 no.5
    • /
    • pp.373-380
    • /
    • 2004
  • The production of sweet (su) and super sweet corns (sh2) has been economically feasible in Korea in recent years. Major factors limiting super sweet corn production are low germination and low seedling vigor. Since seed quality is closely related to seed maturity, the optimum harvest time for the seed production of sweet and super sweet corns was studied and the quality of seeds with varying maturities was investigated in 2001 and 2002 cropping seasons. The parents of the sweet corn seeds were Hybrid Early Sunglow and 'Golden Cross Bantam 70' and those of super sweet corn were Xtrasweet 82 and 'For­tune'. Seeds were harvested at 21, 28, 35, 42, 49, and 56 days after silking (DAS). As the seeds developed, seed weight of sweet corn increased and the seed moisture content decreased faster than that of super sweet corn. Germination rates of sweet corn seeds harvested 21 and 28 DAS at $25^{\circ}C$ and emergence rates in the cold soil test were significantly lower than those of seeds harvested after 42 DAS in both years. Although the germination rates of super sweet corn seeds with varying maturities showed similar patterns as sweet corn seeds at $25^{\circ}C$, the emergence rate of super sweet corn seeds in cold soil test continuously increased with seed maturity. This suggests that seed quality of super sweet corn should be tested in a cold soil test to estimate field emergence. As the seeds developed, leakage of total sugars and electrolytes from the both sweet and super sweet corn seeds decreased up to 42 or 49 DAS. The $\alpha-amylase$ activities of both sweet and super sweet corn seeds increased with seed maturity from 21 to 35 or 49 DAS depending on genotype and year. The optimum harvest time for the seed production of sweet corn was 42 DAS and 49 DAS for super sweet corn considering emergence rate and plumule dry weight in the cold soil test, leakage of sugars and electrolytes from the seeds, and $\alpha-amylase$ activity.

Effects of a Footbath Program on Heart Rate Variability, Blood Pressure, Body Temperature and Fatigue in Stroke Patients (족욕프로그램이 뇌졸중 환자의 심박변이도, 혈압, 체온 및 피로에 미치는 효과)

  • Son, Yu Lim;Yoo, Myung Sook
    • Journal of Korean Biological Nursing Science
    • /
    • v.18 no.1
    • /
    • pp.51-59
    • /
    • 2016
  • Purpose: This study was to examine the effects of a footbath program on heart rate variability, blood pressure, body temperature and fatigue of stroke patients with stroke-induced hemiparesis. Methods: A non-equivalent control group pretest-posttest design was used. Participants were 40 stroke patients, twenty for the footbath program and twenty for the control group, who were hospitalized in a long-term rehabilitation hospital in G city of Korea, from February to April 2014. The twenty participants in the experimental group received the intervention of footbaths and an educational program focused on the prevention of stroke complications; Collected data were analyzed by the IBM SPSS WIN 20.0 program using a t-test, ${\chi}^2$ test, Mann-Whitney U test and repeated measures ANOVA. Results: Significant differences were found in heart rate variability, systolic blood pressure, hand and foot temperatures and fatigue between the two groups. But no significant differences were found in diastolic blood pressure, core temperatures, forehead temperatures, and hand temperatures between the two groups. Conclusion: The footbath program was an effective intervention for skin temperature change and fatigue reduction for stroke patients. Therefore, it is recommended that the footbath program can be utilized as an effective nursing intervention for stroke patients in long-term rehabilitation care hospitals.

A Study on The Development and Evaluation of Mine Detective Gear (지뢰 탐지용 방호복 구성과 방호성능 및 착용감 평가)

  • 손부현;최혜선
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.25 no.4
    • /
    • pp.707-718
    • /
    • 2001
  • The purpose of this study is to evaluate a newly developed protective suit with the fragments of grenade. The protection efficiency should be strengthened upon the degree of wound. The fragment weight of the used grenade was measured and the kinetic energy of the maximum speed of the fragments in the field test was 137.7J and this could be the protective efficiency test by the multitude fragments in less than 0.031g of the M16A1. The panel inserted to the new demining suit has protection rate of 100% within the distance of 1m and sample II has protection rate of 100% only beyond the distance of 5m. The test showed that the protection rate on the protective suit of the existing garment was comparatively high, however, the protection rate of the sleeve part was very low. The new demining suit through the research demand some complementary measures to lower the temperatures in ear, average skin temperatures, and the temperatures-humidity inside the clothing for summer climate condition, It showed that 30 minutes of rest on the clothing was difficult to go back to the original condition. But in winter climate condition, there was no problem in the temperature, humidity, and comfort to go back to the original condition during the rest and was better in warmth.

  • PDF

The Characteristic of Swelling Index Evaluated by CRS Consolidation Test (일정변형속도(CRS) 압밀시험에 의한 팽창지수 산정 특성)

  • 한상재;김수삼;김병일;이응준
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.5
    • /
    • pp.311-317
    • /
    • 2003
  • The swelling index of clayey soil was examined by constant rate of strain(CRS) consolidation test. Four kinds of strain rate were applied during unloading. The strain rates are l/l, l/5, 1/10, l/l 5 of loading. The strain rates during loading are 0.05%/min and 0.03%/min. From the test results using standard consolidometer, the swelling indexes were much similar values in case of 1/5 or 1/10 of the strain rate during loading stage. In the relation between effective stress and excess pore water pressure ratio, it was found that the existence of cross point and the stress level can be separated into two zones according to the swelling index.

Modelling the rheological behaviour of fresh concrete: An elasto-viscoplastic finite element approach

  • Chidiac, S.E.;Habibbeigi, F.
    • Computers and Concrete
    • /
    • v.2 no.2
    • /
    • pp.97-110
    • /
    • 2005
  • Rheological behaviour of fresh concrete is an important factor in controlling concrete quality. It is recognized that the measurement of the slump is not a sufficient test method to adequately characterize the rheology of fresh concrete. To further understand the slump measurement and its relationship to the rheological properties, an elasto-viscoplastic, 2-D axisymmetric finite element (FE) model is developed. The FE model employs the Bingham material model to simulate the flow of a slump test. An experimental program is carried out using the Slump Rate Machine (SLRM_II) to evaluate the finite element simulation results. The simulated slump-versus-time curves are found to be in good agreement with the measured data. A sensitivity study is performed to evaluate the effects of yield stress, plastic viscosity and cone withdrawal rate on the measured flow curve using the FE model. The results demonstrate that the computed yield stress compares well with reported experimental data. The flow behaviour is shown to be influenced by the yield stress, plastic viscosity and the cone withdrawal rate. Further, it is found that the value of the apparent plastic viscosity is different from the true viscosity, with the difference depending on the cone withdrawal rate. It is also confirmed that the value of the final slump is most influenced by the yield stress.

The steam turbine condenser pressure optimization with different heat rate correction curves (각기 다른 열소비율 보정곡선을 갖는 증기터빈의 최적 복수기 운전압력 설정)

  • Cho, Cheon-Hwan;Baek, Nam-Ho;Hur, Jin-Hyek;Lee, Jae-Heon;Moon, Seung-Jae;Yoo, Ho-Sun
    • 한국전산유체공학회:학술대회논문집
    • /
    • 2008.03b
    • /
    • pp.224-227
    • /
    • 2008
  • The present study performs a test of a change in a condenser pressure on two kinds of power plants having different condenser pressure-heat rate correction curve and evaluates the results. According to a result of the test, it is confirmed that a sub-critical drum type steam power plant is optimally operated at the condenser pressure of 38㎜Hga that is designed, even during winters. On the other hand, it can be found that a supercritical once through type steam power plant operated at the condenser pressure that is reduced below a design value, that is, up to 28㎜Hga during winters is advantageous in view of turbine efficiency and is operated without a problem in facility operation such as moisture erosion, turbine vibration, etc. Also, the present study compares and reviews a condenser pressure-heat rate correction curve proposed by a manufacturer and a test value. The present study proposes optimum condenser operation pressure capable of concurrently satisfying the stable operation and efficiency improvement of the power plant facility that is operating, making it possible to support an efficient operation of a power plant.

  • PDF

STRAIN RATE CHANGE FROM 0.04 TO 0.004%/S IN AN ENVIRONMENTAL FATIGUE TEST OF CF8M CAST STAINLESS STEEL

  • Jeong, Ill-Seok;Kim, Wan-Jae;Kim, Tae-Ryong;Jeon, Hyun-Ik
    • Nuclear Engineering and Technology
    • /
    • v.43 no.1
    • /
    • pp.83-88
    • /
    • 2011
  • To define the effect of strain rate variation from 0.04% to 0.004%/s on environmental fatigue of CF8M cast stainless steel, which is used as a primary piping material in nuclear power plants, low-cycle fatigue tests were conducted at operating pressure and temperature condition of a pressurized water reactor, 15 MPa and $315^{\circ}C$, respectively. A high-pressure and high-temperature autoclave and cylindrical solid fatigue specimens were used for the strain-controlled low-cycle environmental fatigue tests. It was observed that the fatigue life of CF8M stainless steel is shortened as the strain rate decreases. Due to the effect of test temperature, the fatigue data of NUREG-6909 appears a slightly shorter than that obtained by KEPRI at the same stress amplitude of $1{\times}10^3$ MPa. The environmental fatigue correction factor $F_{en}$'s calculated with inputs of the test data increases with high strain amplitude, while the $F_{en}$'s of NUREG-6909 remain constant regardless of strain amplitude.

Effect of Education on Infection Control for Multidrug Resistant Organism on Infection Control by NICU Nurses (다제내성균 감염관리 교육이 신생아 중환자실 간호사의 감염관리에 미치는 영향)

  • Lim, Jihee;Bang, Kyung-Sook
    • Child Health Nursing Research
    • /
    • v.22 no.3
    • /
    • pp.172-181
    • /
    • 2016
  • Purpose: This study was conducted to examine the effect of education on infection control for multidrug resistant organism (MDRO). Methods: One group pre-post time series design was used. Infection control education for MDRO infection was provided to nurses working in the Neonatal Intensive Care Unit (NICU). Knowledge and recognition were evaluated before and after education. Hand hygiene compliance, MDRO isolation rate and central line-associated bloodstream infection (CLABSI) rate were used as outcome variables. Data from 45 nurses was used for analysis. Results: General knowledge about MDRO increased (p=.011). Responses to questions about image of MDRO and MDRO management tended to change in a positive direction (p=.046). Hand hygiene compliance was 100% at pre-test, 79.5% during education period and 98.4% at post-education period. MDRO isolation rate was 6.83 per 1,000 patient days at pre-test, 10.24 during education period and 6.68 at post-education period. CLABSI rate was 3.76 per 1,000 central line days at pre-test, 6.84 during education period and 4.71 at post-education period. Conclusion: Findings indicate that the education program is effective in improving knowledge about MDRO in NICU nurses. However, more reliable indicators should be used to determine long-term effects.

High-Strain-Rate Deformation of Fe-6.5wt.%Si Alloys using a Split Hopkinson Pressure Bar Technique (홉킨슨 압력봉법을 이용한 Fe-6.5wt.%Si 합금의 고변형률속도 거동)

  • Yoon, Young-Ki;Yoon, Hi-Seak;Umakoshi, Yukichi;Yasuda, Hiroyuki Y.
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.7
    • /
    • pp.1073-1081
    • /
    • 2001
  • Many researches have published numerous papers about the high-strain-rate obtained from Split Hopkinson Pressure Bar(SHPB) tests. And 6.5wt%Si steel is widely known as an excellent magnetic material because its magnetostriction is nearly zero. Single crystals are prepared by the Floating Zone(FZ) method, which melts the alloy by the use of a high temperature electron beam in a pure argon gas condition. In this paper, the fracture behavior of the poly crystals and single crystals (DO$_3$phase) of Fe-6.5wt%Si alloy by SHPB test is observed. The comparison of high-strain-rate results with static results was done. Obtained main results are as follows: (1) Fe-6.5wt%Si alloy has higher strength at high-strain-rate tensile. SHPB results of polycrystal are twice as high as static results. (2) From the fractography, the cleavage steps are remarkably reduced in the SHPB test compared with the static test.