• 제목/요약/키워드: Rate Test

검색결과 13,585건 처리시간 0.043초

Corrosion Fatigue Cracking of Low Alloy Steel in High Temperature Water

  • Lee, S.G.;Kim, I.S.;Jang, C.H.;Jeong, I.S.
    • Corrosion Science and Technology
    • /
    • 제2권2호
    • /
    • pp.93-97
    • /
    • 2003
  • Fatigue crack growth test or low alloy steel was performed in high temperature water. Test parameters were dissolved oxygen content. loading frequency and R-ratio ($P_{min}/P_{max}$). Since the sulfur content or the steel was low, there were no environmentally assisted cracks (EAC) in low dissolved oxygen(DO) water. At high DO, the crack growth rate at R = 0.5 tests was much increased due to environmental effects and the crack growth rate depended on loading frequency and maximized at a critical frequency. On the other hand, R = 0.7 test results showed an anomalous decrease of the crack growth rate as much different behavior from the R = 0.5. The main reason of the decrease may be related to the crack tip closure effect. All the data could be qualitatively understood by effects of oxide rupture and anion activity at crack tip.

온수분배기용 유량제어밸브의 개발 (Development of Flow Control Valves for Hot Water Distribution Manifolds)

  • 권우철;윤준용;유선학
    • 한국유체기계학회 논문집
    • /
    • 제13권4호
    • /
    • pp.11-17
    • /
    • 2010
  • The developed control valves, installed on the hot water distribution manifolds for the floor heating system, consist of the balancing valves and the shut-off valves. The balancing valve was designed to improve the flow control performance and to reduce the noise emitted from the valve by modification of the general V port. The port of the shut-off valve was designed with two ceramic plates, working by rotating upper plate, to improve the duration and to reduce the noise. For the evaluation of the new valves, the flow rate was measured and noise level test was carried out. The test results showed that the error of the flow rate accuracy test for the flow balance of each manifold circuit was less than ${\pm}3%$ and the noise level was less than 35 dB(A).

Empirical Capacity Degradation Model for a Lithium-Ion Battery Based on Various C-Rate Charging Conditions

  • Dong Hyun Kim;Juhyung Lee;Kyungseop Shin;Kwang-Bum Kim;Kyung Yoon Chung
    • Journal of Electrochemical Science and Technology
    • /
    • 제15권3호
    • /
    • pp.414-420
    • /
    • 2024
  • Lithium-ion batteries are widely used in many applications due to their high energy density, high efficiency, and excellent cycle ability. Once an unknown Li-ion battery is reusable, it is important to measure its lifetime and state of health. The most favorable measurement method is the cycle test, which is accurate but time- and capacity-consuming. In this study, instead of a cycle test, we present an empirical model based on the C-rate test to understand the state of health of the battery in a short time. As a result, we show that the partially accelerated charge/discharge condition of the Li-ion battery is highly effective for the degradation of battery capacity, even when half of the charge/discharge conditions are the same. This observation provides a measurable method for predicting battery reuse and future capacity degradation.

Mixed double-embryo transfer: A promising approach for patients with repeated implantation failure

  • Stamenov, Georgi Stamenov;Parvanov, Dimitar Angelov;Chaushev, Todor Angelov
    • Clinical and Experimental Reproductive Medicine
    • /
    • 제44권2호
    • /
    • pp.105-110
    • /
    • 2017
  • Objective: The purpose of this study was to evaluate the efficacy of frozen mixed double-embryo transfer (MDET; the simultaneous transfer of day 3 and day 5 embryos) in comparison with frozen blastocyst double-embryo transfer (BDET; transfer of two day 5 blastocysts) in patients with repeated implantation failure (RIF). Methods: A total of 104 women with RIF who underwent frozen MDET (n = 48) or BDET (n = 56) with excellent-quality embryos were included in this retrospective analysis. All frozen embryo transfers were performed in natural cycles. The main outcome measures were the implantation rate, clinical pregnancy rate, multiple pregnancy rate, and miscarriage rate. These measures were compared between the patients who underwent MDET or BDET using the chi-square test or the Fisher exact test, as appropriate. Results: The implantation and clinical pregnancy rates were significantly higher in patients who underwent MDET than in those who underwent BDET (60.4% vs. 39.3%, p=0.03 and 52.1% vs. 30.4%, p=0.05, respectively). A significantly lower miscarriage rate was observed in the MDET group (6.9% vs. 10.7%, p=0.05). In addition, the multiple pregnancy rate was slightly, but not significantly, higher in the MDET group (27.1% vs. 25.0%). Conclusion: MDET was found to be significantly superior to double blastocyst transfer. It could be regarded as an appropriate approach to improve in vitro fertilization success rates in RIF patients.

차체용 강판의 온도에 따른 변형률 속도 민감도 연구 (A study on the strain rate sensitivity according to the temperature for steel sheets of an auto-body)

  • 이희종;송정한;조상순;김석봉;허훈;박성호
    • 한국소성가공학회:학술대회논문집
    • /
    • 한국소성가공학회 2005년도 추계학술대회 논문집
    • /
    • pp.148-151
    • /
    • 2005
  • This paper is concerned with the thermo-mechanical behavior and temperature dependent strain rate sensitivity of steel sheet for an auto-body. In order to Identify the temperature dependent strain rate sensitivity of SPRC35R and SPRC45E, uniaxial tension tests are performed with the variation of the strain rates from 0.001/sec to 200/sec, and the variation of environmental temperatures from $-40^{\circ}C\;to\;200^{\circ}C$. The thermo-mechanical response at the quasi-static state is obtained with the static tensile test and at the intermediate strain rate is from the high speed tensile test. The experimental results show that the strain rate sensitivity increases at low temperature and it decreases at high temperature. It means that as the strain rate getting increasing, the variation of flow stress is more sensitive on the temperature. The results also indicates that the material properties of SPRC35R is more depend on the changes of strain rates and temperature than those of SPRC45E.

  • PDF

한국 원/달러환율과 금리의 관계분석 (Analysis about relation of Won/Dollar Foreign Exchange Rate and Interest Rate of Korea)

  • 김종권
    • 산업경영시스템학회지
    • /
    • 제21권48호
    • /
    • pp.133-144
    • /
    • 1998
  • International capital movement has made progress at global liberalization of finance and foreign exchange, international monetary norm changing into floating exchange rate system, easiness of collection of information and trade at improvement of information communication technology from early of 1970's. Results of empirical test for relation between foreign exchange rate or various determination factors of foreign exchange rate and interest rate are followed by next sentences. First, according to relation between foreign exchange rate and interest rate, correlation for each of variables after OECD entrance is increased. But, long-term & short-term interest rate is affected by Hanbo & Kia's bankruptcy, continuous large scale corporates bankruptcy and crisis of foreign exchange. Therefore, financial instability is occured. If portfolio investment fund has been inflow as it is mollified by continuous shortage of foreign exchange and fall of country's credit rating, it is expected to have positive effect for long-term & short-term interest rate from appreciation of won against dollar. Second, results from relation between determination factor of foreign exchange rate and interest rate are followed by next sentences. If surplus of current account and goods account is continued, yield of corporate bond is to be stable. But, margin of surplus is expected to diminish after second quarter 98, and difference between external and domestic interest (after adjusting foreign exchange rate) is to be diminished. And if net inflows of foreign investor's fund (stock and bond) is diminished, it is to have negative effect for yield of corporate bond. According to foreign investor's investment movement of previous years, hedge fund were stayed at least during two years in Mexico. It means that sudden capital outflow is not to be happened at Korea. But if external factors from depreciation of yen and China's renminbi are instable, interest rate is expected to increase from capital's outflows. Third, if it is to decrease instability of foreign exchange rate from increase in surplus of future current account, credit rating's upwardness, stability of yen and renminbi, foreign exchange rate is expected to be stable. It is expected to have continuous stability from short-term interest rate to long-term interest rate in this empirical test.

  • PDF

한국 원/달러환율과 금리의 관계분석 (Analysis about relation of Won/Dollar Foreign Exchange Rate and Interest Rate of Korea)

  • 김종권
    • 대한안전경영과학회:학술대회논문집
    • /
    • 대한안전경영과학회 2002년도 추계학술대회
    • /
    • pp.305-319
    • /
    • 2002
  • International capital movement has made progress at global liberalization of finance and foreign exchange, international monetary norm changing into floating exchange rate system, easiness of collection of information and trade at improvement of information communication technology from early of 1970's. Results of empirical test for relation between foreign exchange rate or various determination factors of foreign exchange rate and interest rate are followed by next sentences. First, according to relation between foreign exchange rate and interest rate, correlation for each of variables after OECD entrance is increased. But, long-term &short-term interest rate is affected by Hanbo & Kia's bankruptcy, continuous large scale coporates bankruptcy and crisis of foreign exchange. Therefore, financial instability is occured. If portfolio investment fund has been inflow as it is mollified by continuous shortage of foreign exchange and fall of country's credit rating, it is expected to have positive effect for long-term & short-term interest rate from appreciation of won against dollar. Second, results from relation between determination factor of foreign exchange rate and interest rate are followed by next sentences. If surplus of current account and goods account is continued, yield of corporate bond is to be stable. But, margin of surplus is expected to diminish after second quarter 98, and difference between external and domestic interest (after adjusting foreign exchange rate) is to be diminished. And if net inflows of foreign investor's fund (stock and bond) is diminished, it is to have negative effect for yield of corporate bond. According to foreign investor's investment movement of previous years, hedge md were stayed at least during two years in Mexico. It means that sudden capital outflow is not to be happened at Korea. But if external factors from depreciation of yen and China's renminbi are instable, interest rate is expected to increase from capital's outflows. Third, if it is to decrease instability of foreign exchange rate from increase in surplus of future current account, credit rating's upwardness, stability of yen and renminbi, foreign exchange rate is expected to be stable. It is expected to have continuous stability from short-term interest rate to long-term interest rate in this empirical test.

  • PDF

재사용(再使用) 투석기(透析器)의 효과(效果) ${\cdot}$ 안정성(安定性) 및 비용절감(費用節減)에 관한 연구(硏究) (A Study of the Effect, Safety and Saving Expense by Reusing Hemodialyzer)

  • 정하정
    • 간호행정학회지
    • /
    • 제3권1호
    • /
    • pp.93-106
    • /
    • 1997
  • By the increase of the rate of existence of the hemodialyzing patients, they were required the long run treatment. Regardless of medical insurance expansion, hemodialyzing cost much expenses so that hospital has been considering the reuse of hemodialyzer and flowing euqipments along with the diverse study and progress of the ways of hemodialyzing and medical instruments. This study was aimed to provide the basic materials regarding the reuse of hemodialyzer which is used for the patients of chronic renal disease. The reusing program in the artificial kidney center of K hospital has been used for this study from 50 patients aften one year result from Sep. 1995 through Aug. 1996. Automatic equipment of DRS-4 made by Seratronic Co., was used as the equipment and it was retreated with the function test simultaneously. Compliaction and confirmation of the infection were by the records of the hemodialysis of the patients. SPSS was used for the analysis of the materials by computerization. The character of the patients and the rate of removal was by mistake and percentage, function test and rate of complication by Ftest(ANOVA) and the rate of complication per items by ${\chi}^2$ and Ftest. As the post test the Duncan's test was used for the statistically significant different variables in the standard of p<.05 after Ftest. The followings are the summary of the result : 1) In the function test of the new hemodialyzer and the reused one, and in all of CA110 and CF15.11, the dialyzer ultrafiltration coeffient(KUf) was appeared to have been higher in the reusing groups than the first use ones. This has been the normal limit showing no troubles with them. 2) In the function test of the new and reused hemodialyzer, in all of CA110 and CF15.11, the total blood volume was appeared to have been the less value in the reuse groups than the new ones. This was the price within 80% of the first price that both showed possible for use. 3) The result of reuse hemodialyzer of CA110 was $29.48{\pm}7.83$ in average in the test of leak test while $17.3{\pm}7.96$ in reuse of CF15.11. The normal limit of <60 was the leak test result. So both of the hemodialyzer was normal for reuse. 4) The rate of removal of Blood Urea Nitrogen(BUN) was 72.25% in CA110 hemodialyzer by reusing 16-20 times as the highest rate showing the better result in the reuse hemodialyzer, while in CF15.11 hemodialyzer showed 71.16% by highest rate in the first use by the highest rate with no difference from the reuse. 5) The rate of removal of serum creatinine of CA110 was 64.08% by highest rate in reuse of 1-5 times by showing better result in reuse hemodialyzer. While in CF15.11 66.47% the highest by reuse of 16-20 times showing no difference from each other. 6) No patients were admitted or precribed by antibiotics in relation with reuse dialyzer and no reports were shown about hepatitis $B{\cdot}C$. AIDS in fection. 7) Of the total 248 episods of complication due to the hemodialyzing, 86 by first use, 73 by 1-5 times, 35 by 6-10 times, 35 by 11-15 times and 19 by 16-20 times have been shown which have had no significant difference between the groups. 8) In the comparison of the expense for the hemodialyzer, there was the effect of saving 11,597.6 Won between the first and reuse hemodialyzer. And by decreasing the extracted materials, they did the great role of disposing the waste matters.

  • PDF

레이저 형광법을 이용한 우식유발 예측모형 (CARIES PREDICTION MODEL USING LASER FLUORESCENCE)

  • 이상호;이창섭;정연화
    • 대한소아치과학회지
    • /
    • 제28권1호
    • /
    • pp.16-24
    • /
    • 2001
  • 레이저 형광법을 이용하여 각 개인의 우식의 활성도를 측정할 수 있는지를 규명하기 위해 $7\sim9$세의 아동 50명을 대상으로 치아의 순면과 협면에 아르곤 레이저를 조사하고 특수 필터를 사용하여 초기 치아우식증이 관찰되는 치아의 수를 측정하고, 이와 같은 초기 치아우식증의 수를 측정하는 우식활성법과 기존의 우식 활성도 측정 방법인 dDfFtT rate, Streptococcus mutans colony count와 상관성을 비교, 평가하고, 레이저 형광법을 이용한 우식활성검사의 특이도, 민감도, 진단력을 평가한 결과, 다음과 같은 결론을 얻었다. 1. 아르곤 레이저 형광법을 이용한 우식활성도 측정법은 기존의 Streptococcus mutans colony count 검사법과 비교적 높은 상관관계를 보였다($\gamma=0.48$, P<0.01). 2. 아르곤 레이저 형광법을 이용한 우식활성도 측정법은 dDfFtT rate 검사와 상관관계가 있었다($\gamma=0.39$, P<0.01). 3. Streptococcus mutans colony count와 dDfFtT rate와는 낮은 상관관계가 있었다($\gamma=0.27$, P<0.05). 4. dDfFtT rate를 기준검사 방법으로 하였을 때, 레이저 형광법을 이용한 우식활성 검사법은 특이도 44.4%, 민감도 85.7%, 진단력이 87.8%였다. 5. dDfFtT rate를 기준검사방법으로 하였을 때, Streptococcus mutans colony count는 특이도 77.8%, 민감도 92.9%, 진단력이 84.8%였다. 6. Streptococcus mutans colony count 검사법을 기준검사 방법으로 하였을 때 레이저 형광법을 이용한 우식활성 검사법은 특이도 40.0%, 민감도 84.8%, 진단력이 95.1%였다. 이를 종합해 볼 때 레이저 형광법을 이용하여 관찰한 우식활성 검사법은 기존의 우식활성검사 및 구강환경 검사와 비교적 높은 상관관계, 우수한 진단학적 지표를 보여 주므로써 향후 임상적으로 신뢰도와 타당성이 높은 우식활성 검사법으로서 그 활용 가능성이 높을 것으로 사료된다.

  • PDF

PC 사용 환경에 기반한 2.5 인치 하드 디스크의 수명주기 예측에 대한 연구 (The Study on Estimating Life Cycle of 2.5 Inch Hard disk base on PC using enviroment)

  • 조의현;박정규;이민우;권순무
    • 디지털콘텐츠학회 논문지
    • /
    • 제15권2호
    • /
    • pp.301-308
    • /
    • 2014
  • 최근에 데이터가 대용량화됨에 따라 정보 저장의 중요성이 부각되고 있다. 본 연구는 대용량 저장장 치에 많이 사용되는 2.5인치 HDD에 대해서 가속 시험결과를 토대로 연간 제품 고장률을 예측하고 사용 환경에 대한 연간 제품 고장률과의 차이를 최소화 시키는 새로운 방안을 제시하고자 한다. 반품된 2.5인치 HDD 309개의 정보를 분석하여 실사용 환경의 시간당 전송량을 구했고, 가속 수명시험으로부터 가속 시험조건의 시간당 전송량을 구한 후, 사용률에 대한 가속 계수를 산출했다. 온도에 대한 가속 계수, 사용률에 대한 가속 계수와 고장률로 연간 제품 고장률을 예측하였다. 가속 시험의 시간당 전송량 81.4GB/hour와 사용자 93.4 %까지 대표하는 실사용 환경의 시간당 전송량은 5.8 GB/hour로 산출한 사용률에 대한 가속 계수는 14.1이다. 실사용 환경의 연간 제품 고장률은 1년 이후 안정화 되었으며, 이때 연간 제품 고장률은 0.3~0.378 % 이내에서 변동 하였다. 본 연구를 통하여 예측된 연간 제품 고장률은 0.4 %로 실사용 환경의 연간 제품 고장률과 75~94%의 일치됨을 보였다. 본 연구는 제조사의 가속수명 결과로 실사용 환경을 연간 제품 고장률을 예측하는 방법에 영향을 줄 것이다.