• 제목/요약/키워드: Rate Test

검색결과 13,532건 처리시간 0.04초

BGA 및 Flip Chip 패키지의 볼전단 특성에 미치는 시험변수의 영향 (Effect of Test Parameter on Ball Shear Properties for BGA and Flip Chip Packages)

  • 구자명;정승부
    • 대한용접접합학회:학술대회논문집
    • /
    • 대한용접접합학회 2005년도 춘계학술발표대회 개요집
    • /
    • pp.19-21
    • /
    • 2005
  • The ball shea. tests for ball grid array (BGA) and flip chip packages were carried out with different displacement rates to find out the optimum condition of the displacement rate for this test. The BGA packages consisted of two different kinds of solder balls (eutectic Sn-37wt.%Pb and Sn-3.5wt.%Ag) and electroplated Au/Ni/Cu substrate, whereas the flip chip package consisted of electroplated Sn-37Pb solder and Cu UBM. The packages were reflowed up to 10 times, or aged at 443 K up to 21 days. The variation of the displacement rate resulted in the variations of the shear properties such as shear force, displacement rate at break, fracture mode and strain rate sensitivity. The increase in the displacement rate led to the increase of the shear force and brittleness of solder joints.

  • PDF

조사연구-콘칼로리메타를 이용한 화재시험에 대하여

  • 이두형
    • 방재기술
    • /
    • 통권19호
    • /
    • pp.22-28
    • /
    • 1995
  • The rate of heat release is probably the single most important measure of fire hazard. Several tech-niques were developed for the measurement of rate of heat release, but were not suitable for fire test-ing purpose. Recently the application of oxygen consumption principle made it possible to development of well-characterized heat release rate measurement apparatus, the furniture calorimeter for large-scale fire tests and the cone calorimeter for bench-scale fire tests. The cone calorimeter can be used to determine the ignitability as well as heat release rate and smoke development, mass loss rate, combustion gas production etc. from burning materials. Thus, test method using cone calorimeter, an internationally recognized and accepted for the evalua-tion of fire properties, is a very promising tool for combustion study on various kind of materials and products.

  • PDF

흉추 가동성 운동프로그램이 만성 요통 환자의 통증과 심박 변이도 및 우울증에 미치는 영향 (Effects of Thoracic Flexibility Exercise Program on Pain, Heart Rate Variability, and Depression in Patients with Chronic Low Back Pain)

  • 박동환;이은혁;이강성
    • 대한통합의학회지
    • /
    • 제7권4호
    • /
    • pp.161-170
    • /
    • 2019
  • Purpose : This study aimed to investigate the effects of a thoracic flexibility exercise program on pain, heart rate variability (HRV), and depression in patients with chronic low back pain. Methods : Fifty patients with chronic low back pain participated in this study. Each participant performed a pre-test and post-test. The outcome measures evaluated were a visual analog scale, HRV test results (automatic activity, standard deviation normal to normal [SDNN], low frequency [LF], high frequency [HF], and LF/HF ratio), and the Beck Depression Inventory. Patients underwent conventional physiotherapy for 35 minutes per session. In addition, a thoracic flexibility exercise program (trunk rotation exercise, McKenzie exercise, and supine thoracic extension exercise) were performed 3 times per week for 4 weeks. Results : After the training period, the visual analog scale results showed a significant decrease in the post-test compared to the pre-test. Automatic activity, SDNN, LF, HF, and LF/HF ratio significantly increased in the post-test compared to the pre-test. The Beck depression inventory results significantly decreased in the post-test compared to the pre-test. Conclusion : This study demonstrated that a thoracic flexibility exercise program improves a visual analog scale, HRV (automatic activity, SDNN, LF, HF, and LF/HF ratio), and the Beck Depression Inventory in patients with chronic low back pain.

방류수 유량계(전자기유량계, 파샬플룸)의 특성평가 연구 (A Study on Comparison of the Characteristic Test of Discharge Water Flowmeters (Electromagnetic Flowmeter, Parshall Flume))

  • 안양기;김지영;김금희;장희수;정정필;최종우
    • 한국유체기계학회 논문집
    • /
    • 제18권6호
    • /
    • pp.57-62
    • /
    • 2015
  • The test of comparing liquid flow calibration system (approved by KOLAS) for accuracy and structure change test was performed in the test bed in order to evaluate the typical characteristics of the electromagnetic flow meters and parshall flume that are generally used in the water discharging facilities. The results of the accuracy comparing test with liquid flow calibration system showed the error of less than 2%. Pharshall plume got error up to -8.3% (low flow) from the flow rate test, but less than 4% from the accumulated flow test because of offset error at high flow rate and low flow rate. Evaluation of structual change test was tested with only parshall flume using structure and it consisted of installation angle (parshall flume and level sensor) and position change. Installation angle, water level sensor angle and position changing test for parshall flume had errors of 3.1%~-9.2%, 0.4%~-5.6% and 0.2%~1.3% respectively. Especially, the error showed the largest increase when the water level sensor measured the point of decreased flow by the structure change. Therefore, error factors (change of straight pipe length, installation of obstacle or effect of foreign substances on water level sensor) that can often occur in the field should be derived and the research for optimized installation method should be carried out continuously.

사상체질분류검사지에서 검사-재검사법을 통한 설문 문항에 대한 연구 (A Study on Questionnaires through the Test-Retest Method of Questionnaire for the Sasang Constitution Classification II)

  • 신미란;고호연;이재혁
    • 사상체질의학회지
    • /
    • 제35권1호
    • /
    • pp.35-45
    • /
    • 2023
  • Objectives We tried to examine the change in the test-retest response for the questionnaire itself regarding the QSCCII. Methods Tests were conducted twice times with an interval of 6 months between tests for test-retest reliability analysis. We examined the test-retest answer agreement rate (%) in all items of QSCCII . We conducted NcNemar analysis to examine test-retest reliability for 77 items selected from the QSCCII. Results The body shape-multiple-choice items showed a tendency of low test-retest agreement rate and most of the questions about when I was not well and when I felt my body condition improve showed an high test-retest agreement rate tendency in all items of QSCCII. As a result of the research on the selected 77 items, there was a significant change in the answer in item No.25, 58(in the item of Soeumin) item No.45, 103(in the item of Taeumin) and item No.87 (in the item of Soeumin) (Table.3, 4, 5, 6). Conclusion The QSCCII is shown as a questionnaire composed of mostly no significant response changes in test-retest in each item through this study. Some items were appropriately deleted in the process of developing the advanced model, but there are also items that should be considered further. It is thought that some items should be used after being refined in content and form.

PET-CT 검사 환자의 외부 방사선량률 변화 (Changes in External Radiation Dose Rate for PET-CT Test Patients)

  • 김수진;한은옥
    • Journal of Radiation Protection and Research
    • /
    • 제37권2호
    • /
    • pp.103-107
    • /
    • 2012
  • PET-CT 검사 환자의 피폭선량 감소를 위한 기초자료 제공의 일환으로 PET-CT 검사 환자의 방사선량률의 변화를 분석하고자 하였다. PET-CT 검사 환자의 방사선량률을 측정한 결과 이론과 같이 방사성의약품이 투여된 환자로부터 거리가 멀수록, 시간이 지날수록 방사선량률은 감소되는 것을 볼 수 있었다. 특히 신체부위에 따라서는 방사성의약품 정맥 주사 즉시인 약 4.17분에서는 흉부, PET-CT 검사 전 배뇨 후인 약 77.47분 이후부터는 두부가 가장 높게 나타났다. 일반화되어 있는 정보와 같이 PET-CT 검사 환자로부터 받는 방사선 피폭량을 감소시키기 위해서는 보호자나 방사선작업종사자가 환자로부터 거리를 멀리하거나 방사능이 감소된 이후의 시간부터 접촉하는 것이 바람직하다. 불가피한 접촉이 필요하다면 가능한 거리는 200 cm이상을 확보하는 것이 바람직하다. 또한 초기에는 흉부, 방사성의약품 투여 후 약 77분 이후부터는 두부에 방사선량률이 높기 때문에 환자 신체적 특징을 고려한 접촉도 함께 이루어진다면 최적화 달성에 도움이 될 것이라고 보여 진다. 본 연구에서 도출된 PET-CT 검사 환자의 거리, 시간, 신체부위에 따른 방사선량률 변화를 알 수 있다는 점에서 연구에 의의가 있다고 본다. 향후 연구에서는 본 연구에서 도출된 결과를 바탕으로 환자 개인특성에 따른 방사선량률의 변화 차이를 분석하여 환자, 보호자, 종사자의 피폭선량 감소에 활용할 수 있도록 지속적인 연구가 수행되는 것이 필요하다고 본다.

고등학생의 신체활동에 따른 수면의 질 및 심박변이도 (Quality of Sleep and Heart Rate Variability by Physical Activity in High School Students)

  • 박민선;최모나;이향규;이명호
    • Child Health Nursing Research
    • /
    • 제21권3호
    • /
    • pp.195-203
    • /
    • 2015
  • Purpose: This study was done to investigate quality of sleep and heart rate variability by the physical activity in high school students. Methods: A survey that measures physical activity and quality of sleep was distributed to 118 students at Y High School. Heart rate variability was obtained using the LXC3203 heart rate monitor. The data of 105 students were analyzed using descriptive statistics, t-test, x2-test, and ANOVA with $Scheff{\acute{e}}$ test. Results: Boys and students with part-time jobs had significantly higher physical activity. The quality of sleep was significantly high when the students were non-smokers, felt healthy, happy, less stressed, and satisfied with their school lives. Mean heart rate was significantly higher among girls, and standard deviation from normal to normal R-R intervals were high in boys. Physical activity had no significant relationships with quality of sleep and heart rate variability. Conclusions: Physical activity should be encouraged for high school students, especially for girls. An experimental study with different intensity and time of physical activity is recommended to examine the relationships with quality of sleep and heart rate variability in the future.

원전 격납건물 국부누설률시험에서의 압력감소법을 이용한 과다누설 측정 방법 (Excessive Leakage Measurement Using Pressure Decay Method in Containment Building Local Leakage Rate Test at Nuclear Power Plant)

  • 이원규;김창수;김왕배
    • 비파괴검사학회지
    • /
    • 제36권3호
    • /
    • pp.231-235
    • /
    • 2016
  • 원자력발전소에서 격납건물 국부누설률시험(LLRT)에 사용되는 누설률 측정 방법에는 유량보충법과 압력감소법이 있으며, 대부분의 발전소에서는 유량보충법을 우선 적용하고 있다. 유량보충법은 누설되는 양만큼 보충되는 유량을 측정하여 누설률을 계산하는 방식이다. 그러나 과도한 누설이 발생하여 시험압력 유지가 어려울 경우 압력감소법이 보완적으로 사용될 수 있다. 압력감소법은 시험압력보다 낮은 압력을 적용하여 누설률을 측정할 수 있기 때문이다. 본 논문에서는 원자력발전소 격납건물 국부누설률시험에서 압력감소법을 이용한 과다누설 측정 방안을 연구하고자 하였다. 이에 따라 현장에서의 누설시험 조건과 유사하게 실험장치를 구성하여 실증실험을 수행하였다. 실험 결과 압력감소법에서의 누설률 변화 특성을 확인하였으며, 여러조건에서 측정된 누설량을 바탕으로 실제 누설률 계산에 필요한 보상비를 산출하였다.

Effect Mo Addition on Corrosion Property and Sulfide Stress Cracking Susceptibility of High Strength Low Alloy Steels

  • Lee, Woo Yong;Koh, Seong Ung;Kim, Kyoo Young
    • Corrosion Science and Technology
    • /
    • 제4권2호
    • /
    • pp.39-44
    • /
    • 2005
  • The purpose of this work is to understand the effect of Mo addition on SSC susceptibility of high strength low alloy steels in terms of microstructure and corrosion property. Materials used in this study are high strength low alloy (HSLA) steels with carbon content of 0.04wt% and Mo content varying from 0.1 to 0.3wt%. The corrosion property of steels was evaluated by immersion test in NACE-TM01-77 solution A and by analyzing the growth behavior of surface corrosion products. SSC resistance of steels was evaluated using constant load test. Electrochemical test was performed to investigate initial corrosion rate. Addition of Mo increased corrosion rate of steels by enhancing the porosity of surface corrosion products. However, corrosion rate was not directly related to SSC susceptibility of steels.

밀봉형 볼베어링용 그리이스의 노화와 잔류수명 (Deterioration and Residual Life of Grease for Sealed Ball Bearing)

  • 최인혁;김정길;김지현;손성구
    • Tribology and Lubricants
    • /
    • 제18권4호
    • /
    • pp.273-278
    • /
    • 2002
  • Grease deterioration of mineral oil type grease was investigated using sealed deep groove ball bearings (6203) and bearing life test rig. The bearing test was performed under 3,000 rpm and 245 N radial load at 120。C. Grease taken ken tested bearings was checked in using certain evaluation methods, for example, oxidation induction time (OIT), FT-IR peak intensity, leakage .ate, bleeding .ate, total acid number. (TAN) and bearing noise increase. Within these test conditions, OIT, TAN, bleeding rate were changed gradually in accordance with bearing operating time and showed useful indices for deterioration of grease.