• 제목/요약/키워드: Rate Effect

검색결과 23,009건 처리시간 0.044초

인가전압이 디젤 피에조 인젝터의 분무 특성에 미치는 영향 (Effect of Induced Voltage on Spray Characteristics of Piezo Actuated Diesel Injector)

  • 이진우;배충식
    • 한국자동차공학회논문집
    • /
    • 제18권4호
    • /
    • pp.99-106
    • /
    • 2010
  • A piezo-driven injector was applied with a purpose to evaluate the effect of induced voltage on spray characteristics. For this, injection rate, macroscopic imaging, ambient gas entrainment and particle sizing were carried out. It was shown that initial slope of injection rate was steeper as induced voltage increased, while slope of injection rate became mostly constant with fully opened needle. From macroscopoic imaging, longer spray tip penetration was produced with higher induced voltage. Moreover, wider spray angle was detected in the early stage of spray development, when higher induced voltage was applied. Ambient air entrainment rate was increased and particle size was reduced with higher induced voltage.

SNCM강의 피로균열의 발생 및 전파속도에 미치는 질화처리의 영향 (Effect of Nitriding on Fatigue Crack Initiation and Growth Rate in SNCM)

  • 김민건;이상호
    • 산업기술연구
    • /
    • 제23권A호
    • /
    • pp.3-7
    • /
    • 2003
  • Effect of nitriding on fatigue crack initiation and growth rate has been studied on SNCM. Specimens were nitrided for 15 hr at $860^{\circ}C$. The fatigue limit of nitrided specimens was superior to that of annealed($860^{\circ}C$, 15 hr) specimens. Based on detailed observations of slip band and micro crack initiation, it is concluded that the excellent fatigue limit of nitrided specimens is attributed to improved slip initiation resistance by nitriding. The characteristic of fatigue crack growth rate of nitrided specimens was investigated and compared with those of annealed specimens. It was found that by nitriding the crack growth rate was markedly decreased and the threshold stress intensity factor range was improved. It is concluded that the excellent fatigue limit of nitrided specimens is also attributed to improved fatigue crack growth rate and threshold stress intensity factor range by nitriding.

  • PDF

산화막 CMP에서 발생하는 온도가 연마특성에 미치는 영향 (Effect of Temperature on Polishing Properties in Oxide CMP)

  • 김영진;박범영;김형재;정해도
    • 한국전기전자재료학회논문지
    • /
    • 제21권2호
    • /
    • pp.93-98
    • /
    • 2008
  • We investigated the effect of process temperature on removal rate and non-uniformity based on single head kinematics in oxide CMP. Generally, it has been known that the temperature profile directly transfers to the non~uniformity of removal rate on the wafer, which has similar tendency with the sliding distance of wafer. Experimental results show that platen velocity is a dominant factor in removal rate as well as average temperature. However, the non-uniformity does not coincide between process temperature and removal rate, due to slurry accumulation and low deviation of temperature. Resultantly, the removal rate is strongly dependent on the rotational speed of platen, and its non -uniformity is controlled by the rotational speed of polishing head. It means lower WIWNU (With-in-wafer-non-uniformity) can be achieved in the region of higher head speed.

샘플링율이 맥박변이도 시간 및 주파수 영역 분석에 미치는 영향 (An Effect of Sampling Rate to the Time and Frequency Domain Analysis of Pulse Rate Variability)

  • 양윤라;신항식
    • 전기학회논문지
    • /
    • 제65권7호
    • /
    • pp.1247-1251
    • /
    • 2016
  • This study aims to investigate the effect of sampling frequency to the time domain and frequency domain analysis of pulse rate variability (PRV). Typical time domain variables - AVNN, SDNN, SDSD, RMSSD, NN50 count and pNN50 - and frequency domain variables - VLF, LF, HF, LF/HF, Total Power, nLF and nHF - were derived from 7 down-sampled (250 Hz, 100 Hz, 50 Hz, 25 Hz, 20 Hz, 15 Hz, 10 Hz) PRVs and compared with the result of heart rate variability of 10 kHz-sampled electrocardiogram. Result showed that every variable of time domain analysis of PRV was significant at 25 Hz or higher sampling frequency. Also, in frequency domain analysis, every variable of PRV was significant at 15 Hz or higher sampling frequency.

무전해 Ni-Zn-P 도금의 속도 및 안정성에 미치는 첨가제의 영향 (Effect of Additives on Deposition Rate and Stability of Electroless Black Ni-Zn-P Plating)

  • 오영주;황경진;정원용;이만승
    • 한국표면공학회지
    • /
    • 제36권4호
    • /
    • pp.317-323
    • /
    • 2003
  • The effect of additives such as complexing agents, stabilzers and boric acid on the bath stability and the deposition rate of electroless black Ni-Zn plating has been examined. The deposits obtained became black and showed an amorphous structure. The significant increasing in the deposition rate was not found when only glycine and citric acid were used as complexing agents. The deposition rate increased up to 3 and 4 times by adding malic acid and glycolic acid as an additional complexing agent, respectively. The stabilizers and the boric acid, however, had little influence on the deposition rate.

수직 액막형 흡수기의 흡수성능 변화에 미치는 냉각수 유량의 영향 (Effect of the Flow Rate of Coolant on the Absorption Peformance of a Vertical Absorber)

  • 김정국;조금남
    • 설비공학논문집
    • /
    • 제18권5호
    • /
    • pp.410-417
    • /
    • 2006
  • The present study predicted the effect of the flow rate of coolant on the absorption performance of a vertical falling film type absorber Heat and mass transfer peformances were numerically investigated. The exit temperatures of solution and coolant were decreased as the flow rate of the coolant was increased at the film Reynolds number of 100. The absorption mass flux was increased and then decreased as the distance from the inlet of the absorber was increased. The distance showing the maximum absorption mass flux was ranged from 0.3 to 0.5m. The heat flux and the absorption mass flux were increased and then slowly decreased as the flow rate of the coolant was increased. The maximum values were obtained at the flow rate of coolant of 2.0L/min.

플라즈마 정보인자 기반 가상계측을 통한 Si 식각률의 첫 장 효과 분석 (Analysis of First Wafer Effect for Si Etch Rate with Plasma Information Based Virtual Metrology)

  • 유상원;권지원
    • 반도체디스플레이기술학회지
    • /
    • 제20권4호
    • /
    • pp.146-150
    • /
    • 2021
  • Plasma information based virtual metrology (PI-VM) that predicts wafer-to-wafer etch rate variation after wet cleaning of plasma facing parts was developed. As input parameters, plasma information (PI) variables such as electron temperature, fluorine density and hydrogen density were extracted from optical emission spectroscopy (OES) data for etch plasma. The PI-VM model was trained by stepwise variable selection method and multi-linear regression method. The expected etch rate by PI-VM showed high correlation coefficient with measured etch rate from SEM image analysis. The PI-VM model revealed that the root cause of etch rate variation after the wet cleaning was desorption of hydrogen from the cleaned parts as hydrogen combined with fluorine and decreased etchant density and etch rate.

의료기관 종사자의 라이프케어 감정노동과 진료비 삭감 인식도가 삭감률에 미치는 영향 (The Impacts of Emotional Labor and The Recognition Level of Medical Service Fee Reduction of Medical Institution Workers Influencing Reduction Rate)

  • 양유정;이혜승
    • 한국엔터테인먼트산업학회논문지
    • /
    • 제14권8호
    • /
    • pp.345-352
    • /
    • 2020
  • 본 연구는 요양의료기관 종사자의 감정노동과 진료비 삭감 인식도가 삭감율에 미치는 영향을 알아보기 위해 대한민국의 의료기관 종사자 414명을 대상으로 설문조사를 실시하여 다음과 같은 결과를 도출하였다. 첫째, 인구사회학적 특성에 따른 삭감률 차이를 살펴본 결과 입원 삭감률과 외래 삭감률은 근무형태, 현 병원 근무경력과 허가 병상 수에서 유의한 차이를 보였다. 둘째, 감정노동, 진료비 삭감 인식도와 삭감률의 상관관계를 분석한 결과 감정노동과 외래 삭감률은 정적 상관, 진료비 삭감 인식도과 입원 삭감률은 부적 상관, 진료비 삭감인식도과 외래 삭감률은 부적 상관에 유의한 것으로 나타났다. 셋째, 감정노동은 입원 삭감률에 유의한 정적 영향 미치며, 진료비삭감인식도는 입원 삭감률에 유의한 부적 영향 미치는 것으로 나타났다. 감정노동은 외래 삭감률에 유의한 정적 영향을 미치며, 진료비 삭감인식도는 외래삭감률에 유의한 부적 영향을 미치는 것으로 나타났다.

측정표준의 국민경제 기여효과 분석 (Economic Effect of National Measurement Standards)

  • 안병덕;남경희;안웅환;김동진;조연상
    • 기술혁신학회지
    • /
    • 제5권2호
    • /
    • pp.245-256
    • /
    • 2002
  • Measurement standards, as being widely recognized, is necessary for national economic development and advanced industrialization. Also measurement standards give reliability and fair trade to the producers and consumers. Macro-effect of measurement standards using estimation of cost function has four effects: 1) value-added causing effect, 2) effect of employment, 3) reduction effect transaction cost, 4) reduction effect defect rates. In this study, to investigate the impacts between specific and the other industries, we used I-O Table of Korea Bank. The relation between the value-added produced by original production factors and final use is determined through production level, and the relation can be investigated with production causing coefficient matrix. In this study, it was showed that the measurement standards investments including measurement only man power of industries were increased from 1995 rapidly. The establishment and maintenance of measurement standards contributes to reduce the defect rate of products in production process and improve the confidence of the product quality. The results from this study show that measurement technology contributes to improve quality, decrease defect rate, improve production process, develope new products, reduce prime cost and increase the consumer's confidence on the firms. Since these results indicate that measurement standards are very important in the point of their vast contribution, we hope our findings can contribute to encourage measurement activities in industries.

  • PDF

태양열 해수담수화를 위한 증발식 다중효용 담수기 성능평가 (Performance Evaluation of Multi Effect Distillation for Solar Thermal Desalination)

  • 주홍진;곽희열
    • 한국태양에너지학회:학술대회논문집
    • /
    • 한국태양에너지학회 2011년도 춘계학술발표대회 논문집
    • /
    • pp.74-79
    • /
    • 2011
  • This study was accomplished to evaluate the performance of Multi Effect Distillation(MED) for solar thermal desalination system. It was designed Multi effect distillation with $3m^3/day$ capacity and Shell&Tube type heat exchanger. Also, The effective heat transfer of Shell&Tube heat exchanger was used Cu(90%)-Ni(10%) corrugated tube. The parameters relating to the performance of Multi Effect Distillation are known as hot water flow rate. The experimental conditions for each parameters were $18^{\circ}C$ for sea water inlet temperature, $6m^3/hour$ sea water inlet volume flow rate, $75^{\circ}C$ for hot water inlet temperature, 2.4, 3.6, and $4.8m^3/hour$ for hot water inlet volume flow rate, respectively. The results are as follows, Development for Multi effect distillation was required about 40kW heat and 35kW cooling source to produce $3m^3/day$ of fresh water. And, Performance ratio of Development Multi effect distillation was about 2.0191.

  • PDF