• Title/Summary/Keyword: Rapid methods

Search Result 3,252, Processing Time 0.033 seconds

Glomus Tumor in Soft Tissue (연부 조직에 발생한 사구종)

  • Kim, Do-Yeon;Lee, Soo-Hyun;Kim, Min-Ju;Shin, Kyoo-Ho
    • The Journal of the Korean bone and joint tumor society
    • /
    • v.15 no.1
    • /
    • pp.34-43
    • /
    • 2009
  • Purpose: Glomus tumors are rare benign vascular tumors, usually located in the skin or soft tissue of extremities. Approximately 30-50% of glomus tumors occur in subungal area, but glomus tumors have been described in every location even where glomus bodies are not or rarely present. The purpose of this study was to identify clinical, histologic and MRI characteristics of soft tissue glomus tumor. Materials and Methods: Between 1993 and 2008, eight patients underwent surgery of soft tissue Glomus tumor at our institution. Exclusion criteria were patients with Glomus tumors in digits, stomach, trachea and glomus tympanicum. We analyzed medical records, interviews, physical examinations, MR findings and histolocial types retrospectively. Results: There were four men and four women. The mean age was fourty-seven years. The mean prevalence time was eight-point-nine years. In the classic triad of symptoms, all eight patients had pain and tenderness. Two patients complained of cold sensitivity. Two showed skin color changes. After surgery, two showed symptom improvement (VAS $9^{\circ}{\rightarrow}8$, $8^{\circ}{\rightarrow}5$) and?six showed complete disappearance of symptoms. Slightly symptom improvemented (VAS $9^{\circ}{\rightarrow}8$) one had additional surgery two times after first surgery due to relapse/remaining Glomus tumor. The mean size was 13.9 mm. In histology, six were 'solid glomus tumor', one was a mixture of 'solid glomus tumor' and 'lomangioma' and one was 'malignant glomus tumor'. MR findings showed isointense signal on T1 image, high signal on T2 image and strong enhancement on the Gadolinium enhanced image. Conclusion: Glomus tumor has low recurrence rate and malignant change, rapid diagnosis and surgical excision is critical in treatment to prevent unnecessary pain of patient.

  • PDF

An Empirical Study on the Long-Run Performance of Cross-Listings by Multinational Corporations (다국적기업 해외상장의 장기적인 성과에 관한 연구)

  • Kim, Dong-Soon;Park, Sang-An
    • The Korean Journal of Financial Management
    • /
    • v.21 no.2
    • /
    • pp.27-63
    • /
    • 2004
  • Since the 1980s, many multinational corporations have been issuing stocks on foreign stock exchanges, not only to enhance their investor base and liquidity, but also to diversify risks. The phenomenon has also been intensified by the rapid financial globalization and securitization trends. The main purpose of this study is to look into the long-run performance of MNCs' cross-listings of stocks on foreign stock exchanges. We use the event study and cross-sectional regression methods. We obtained some interesting empirical results about the long-run effect of cross-listings. First before the listing data the effect of cross-listing is to increase the underlying stock Vice in the local market. It may be caused by expectation of lower risk and cost of capital. However, after the listing data the stock price has been declining, even if it is not significant. Second, we examine the difference in the long-run cross-listing effect, which may be caused by the listing direction. When listing is made from a less developed market to a more developed market, the effect is better than that in the reverse direction. Furthermore, the effect is worse, when the listing company's home country is the U.S. Third, there is a negative relation between CARs and underlying stock liquidity in the local market, So it implies that a firm, whose underlying stocks are very liquid in the local market should carefully value cross-listing based upon the cost and benefit analysis. Last, but not the least we find that the long-un cross-listing effect is better, when a listing firm's ROE is higher.

  • PDF

Smartphone Security Using Fingerprint Password (다중 지문 시퀀스를 이용한 스마트폰 보안)

  • Bae, Kyoung-Yul
    • Journal of Intelligence and Information Systems
    • /
    • v.19 no.3
    • /
    • pp.45-55
    • /
    • 2013
  • Thereby using smartphone and mobile device be more popular the more people utilize mobile device in many area such as education, news, financial. In January, 2007 Apple release i-phone it touch off rapid increasing in user of smartphone and it create new market and these broaden its utilization area. Smartphone use WiFi or 3G mobile radio communication network and it has a feature that can access to internet whenever and anywhere. Also using smartphone application people can search arrival time of public transportation in real time and application is used in mobile banking and stock trading. Computer's function is replaced by smartphone so it involves important user's information such as financial and personal pictures, videos. Present smartphone security systems are not only too simple but the unlocking methods are spreading out covertly. I-phone is secured by using combination of number and character but USA's IT magazine Engadget reveal that it is easily unlocked by using combination with some part of number pad and buttons Android operation system is using pattern system and it is known as using 9 point dot so user can utilize various variable but according to Jonathan smith professor of University of Pennsylvania Android security system is easily unlocked by tracing fingerprint which remains on the smartphone screen. So both of Android and I-phone OS are vulnerable at security threat. Compared with problem of password and pattern finger recognition has advantage in security and possibility of loss. The reason why current using finger recognition smart phone, and device are not so popular is that there are many problem: not providing reasonable price, breaching human rights. In addition, finger recognition sensor is not providing reasonable price to customers but through continuous development of the smartphone and device, it will be more miniaturized and its price will fall. So once utilization of finger recognition is actively used in smartphone and if its utilization area broaden to financial transaction. Utilization of biometrics in smart device will be debated briskly. So in this thesis we will propose fingerprint numbering system which is combined fingerprint and password to fortify existing fingerprint recognition. Consisted by 4 number of password has this kind of problem so we will replace existing 4number password and pattern system and consolidate with fingerprint recognition and password reinforce security. In original fingerprint recognition system there is only 10 numbers of cases but if numbering to fingerprint we can consist of a password as a new method. Using proposed method user enter fingerprint as invested number to the finger. So attacker will have difficulty to collect all kind of fingerprint to forge and infer user's password. After fingerprint numbering, system can use the method of recognization of entering several fingerprint at the same time or enter fingerprint in regular sequence. In this thesis we adapt entering fingerprint in regular sequence and if in this system allow duplication when entering fingerprint. In case of allowing duplication a number of possible combinations is $\sum_{I=1}^{10}\;{_{10}P_i}$ and its total cases of number is 9,864,100. So by this method user retain security the other hand attacker will have a number of difficulties to conjecture and it is needed to obtain user's fingerprint thus this system will enhance user's security. This system is method not accept only one fingerprint but accept multiple finger in regular sequence. In this thesis we introduce the method in the environment of smartphone by using multiple numbered fingerprint enter to authorize user. Present smartphone authorization using pattern and password and fingerprint are exposed to high risk so if proposed system overcome delay time when user enter their finger to recognition device and relate to other biometric method it will have more concrete security. The problem should be solved after this research is reducing fingerprint's numbering time and hardware development should be preceded. If in the future using fingerprint public certification becomes popular. The fingerprint recognition in the smartphone will become important security issue so this thesis will utilize to fortify fingerprint recognition research.

EVALUATION OF THE VIABILITY OF PERIODONTAL LIGAMENT CELL IN RAT TEETH USING SLOW CRYOPRESERVATION METHOD WITH MAGNETIC FIELD (자기장 저속 냉동보관법을 이용한 쥐 치아 치주인대세포의 활성도 검사)

  • Ahn, Hyun-Jung;Kim, Eui-Seong;Kim, Jin;Kim, Duck-Won;Kim, Ki-Yeol;Lee, Chan-Young;Lee, Seung-Jong
    • Restorative Dentistry and Endodontics
    • /
    • v.33 no.4
    • /
    • pp.332-340
    • /
    • 2008
  • The purpose of this study was to evaluate the viability of periodontal ligament cell in rat teeth using slow cryopreservation method with magnetic field through MTT assay and TUNEL test. For each group, 12 teeth of 4 weeks old white female Sprague-Dawley rat were used for MTT assay, and 6 teeth in TUNEL test. The Maxillary left and right, first and second molars were extracted as atraumatically as possible under tiletamine anesthesia. The experimental groups were group1 (immediately extraction), group 2 (cold preservation at 4$^{\circ}C$ for 1 week), group 3 (rapid cryopreservation in liquid nitrogen), group 4 (slow cryopreservation with magnetic field of 1 G), and group 5 (slow cryopreservation). F medium was used as preservation medium and 10% DMSO as cryoprotectant. After preservation and thawing, the MTT assay and TUNEL test were processed. One way ANOVA and Scheffe method were performed at the 95% level of confidence. The value of optical density obtained after MTT analysis was divided by the value of eosin staining for tissue volume standardization. In both MTT assay and TUNEL test, it had showed no significant difference among group 3, 4, and 5. And group 3 had showed higher viability of periodontal ligament cell than group 2. From this study, slow cryopreservation method with magnetic field can be used as one of cryopreservation methods.

Establishment of Analytical Method for Methylmercury in Fish by Using HPLC-ICP/MS (고성능액체크로마토그래피-유도결합플라즈마 질량분석기를 이용한 어류 중 메틸수은 분석법 확립)

  • Yoo, Kyung-Yoal;Bahn, Kyeong-Nyeo;Kim, Eun-Jung;Kim, Yang-Sun;Myung, Jyong-Eun;Yoon, Hae-Seong;Kim, Mee-Hye
    • Korean Journal of Environmental Agriculture
    • /
    • v.30 no.3
    • /
    • pp.288-294
    • /
    • 2011
  • BACKGROUND: Methylmercury is analyzed by HPLC-ICP/MS because of the simplicity for sample preparation and interference. However, most of the pre-treatment methods for methylmercury need a further pH adjustment of the extracted solution and removal of organic matter for HPLC. The purpose of this study was to establish a rapid and accurate analytical method for determination of methylmercury in fish by using HPLC-ICP/MS. METHOD AND RESULTS: We conducted an experiment for pre-treatment and instrument conditions and analytical method verification. Pre-treatment condition was established with aqueous 1% L-cysteine HCl and heated at $60^{\circ}C$ in microwave for 20 min. Methylmercury in $50{\mu}L$ of filtered extract was separated by a C18 column and aqueous 0.1% L-cysteine HCl + 0.1% L-cysteine mobile phase at $25^{\circ}C$. The presence of cysteine in mobile phase and sample solution was essential to eliminate adsorption, peak tailing and memory effect problems. Correlation coefficient($r^2$) for the linearity was 0.9998. The limits of detection and quantitation for this method were 0.15 and $0.45{\mu}g/kg$ respectively. CONCLUSION: Result for analytical method verification, accuracy and repeatability of the analytes were in good agreement with the certified reference materials values of methylmercury at a 95% confidence level. The advantage of the established method is that the extracted solution can be directly injected into the HPLC column without additional processes and the memory effect of mercury in the ICP-MS can be eliminated.

A COG Variable Analysis of Air-rolling-breakfall in Judo (유도 공중회전낙법의 COG변인 분석)

  • Kim, Eui-Hwan;Chung, Chae-Wook;Kim, Sung-Sup
    • Korean Journal of Applied Biomechanics
    • /
    • v.15 no.3
    • /
    • pp.117-132
    • /
    • 2005
  • It was to study a following research of "A Kinematic Analysis of Air-rolling-breakfall in Judo". The purpose of this study was to analyze the Center of Gravity(COG) variables when performing Air-rolling-breakfall motion, while passing forward over(PFO) to the vertical-hurdles(2m height, take off board 1m height) in judo. Subjects were four males of Y. University squad, who were trainees of the demonstration exhibition team, representatives of national level judoists and were filmed by four 5-VHS 16mm video cameras(60field/sec.) through the three dimensional film analysis methods.COG variable were anterior-posterior directional COG and linear velocity of COG, vertical directional COG and linear velocity of COG. The data collections of this study were digitized by KWON3D program computed The data were standardized using cubic spline interpolation based by calculating the mean values and the standard deviation calculated for each variables. When performing the Air-rolling-breakfall, from the data analysis and discussions, the conclusions were as follows : 1. Anterior-posterior directional COG(APD-COG) when performing Air-rolling-breakfall motion, while PFO over to the vertical-hurdles(2m height) in judo. The range of APD-COG by forward was $0.31{\sim}0.41m$ in take-off position(event 1), $1.20{\sim}1.33m$ in the air-top position(event 2), $2.12{\sim}2.30m$ in the touch-down position(event 3), gradually and $2.14{\sim}2.32m$ in safety breakfall position(event 4), respectively. 2 The linear velocity of APD-COG was $1.03{\sim}2.14m/sec$. in take-off position(event 1), $1.97{\sim}2.22m/sec$. gradually in the air-top position(event 2), $1.05{\sim}1.32m/sec$. in the touch-down position (event 3), gradual decrease and $0.91{\sim}1.23m/sec$. in the safety breakfall position(event 4), respectively. 3. The vertical directional COG(VD-COG) when performing Air-rolling-breakfall motion, while PFO to the vertical-hurdles(2m height) in judo. The range of VD-COG toward upward from mat was $1.35{\sim}1.46m$ in take-off position(event 1), the highest $2.07{\sim}2.23m$ in the air-top position(event 2), and after rapid decrease $0.3{\sim}0.58m$ in the touch-down position(event 3), gradual decrease $0.22{\sim}0.50m$ in safety breakfall position(event 4), respectively. 4. The linear velocity of VlJ.COG was $1.60{\sim}1.87m/sec$. in take-off position(event 1), $0.03{\sim}0.08m/sec$. gradually in the air-top position(event 2), $-4.37{\sim}\;-4.76m/sec$. gradual decrease in the touch-down position(event 3), gradual decrease and -4.40${\sim}\;-4.77m/sec$. in safety breakfall position(event 4), respectively. When performing Air-rolling-breakfall showed parabolic movement from take-off position to air-top position, and after showed vertical fall movement from air-top position to safety breakfall. In conclusion, Ukemi(breakfall) is safety fall method Therefore, actions need for performing safety fall movement, that decrease and minimize shock and impact during Air-rolling-breakfall from take-off board action to air-top position must be maximize of angular momentum, and after must be minimize in touch-down position and safety breakfall position.

Method Development for Determination of Multi-Mycotoxins in Chicken Liver and Kidney Tissues by LC-MS/MS (LC-MS/MS를 이용한 닭 간과 신장 중 곰팡이 독소 6종 동시분석법 개발)

  • Kim, Soohee;Kim, Kwang-Nam;Kim, Hyobi;Song, Jae-Young;Park, Sung-Won
    • Korean Journal of Poultry Science
    • /
    • v.43 no.2
    • /
    • pp.111-118
    • /
    • 2016
  • Mycotoxins are secondary metabolites produced by molds, such as Aspergillus, Fusarium and Penicillium, that have adverse effects on animals and humans. Aflatoxin, ochratoxin, zearalenone, fumonisin and deoxynivalenol are the mycotoxins of greatest agro-economic importance and cause acute disease called mycotoxicoses. Mycotoxicosis in poultry birds results in decreased meat/egg production, immunosuppressant, and hepatotoxicosis. Some of toxins or their metabolites may be retained in animal or human tissues and induce health problems. This study was designed to develop a sensitive liquid chromatography tandem mass spectrometry (LC-MS/MS) method for the simultaneous detection and quantification of mycotoxins, such as aflatoxin $B_1$, aflatoxin $M_1$, ochratoxin A, zearalenone, fumonisin B and deoxynivalenol, in chicken liver and kidney tissues. The mycotoxins were extracted and purified using modified QUECHERS methods, separated by LC and detected by an electrospray ionisation interface (ESI) and tandem MS. Good precision and linearity were observed for most of six mycotoxins. The recovery test for each mycotoxin in liver and kidney tissues mostly indicated good average recovery rates between 80.94% and 98.10% and the coefficient of variation mostly under 13.78%, except for aflatoxin $M_1$ and fumonisin $B_1$. The limit of detection (LOD) for six mycotoxins was $7.6{\sim}145.79{\mu}g/kg$ in liver tissues and $6.07{\sim}197.20{\mu}g/kg$ in kidney tissues. The quantification limits (LOQ) for 6 mycotoxins were in the range $23.04{\sim}441.78{\mu}g/kg$ in liver tissues and $18.40{\sim}597.59{\mu}g/kg$ in kidney tissues, respectively. The developed multi-mycotoxin method in this study permits simultaneous, simple, and rapid determination of several co-existing mycotoxins in chicken liver and kidney tissues.

Modern Paper Quality Control

  • Olavi Komppa
    • Proceedings of the Korea Technical Association of the Pulp and Paper Industry Conference
    • /
    • 2000.06a
    • /
    • pp.16-23
    • /
    • 2000
  • The increasing functional needs of top-quality printing papers and packaging paperboards, and especially the rapid developments in electronic printing processes and various computer printers during past few years, set new targets and requirements for modern paper quality. Most of these paper grades of today have relatively high filler content, are moderately or heavily calendered , and have many coating layers for the best appearance and performance. In practice, this means that many of the traditional quality assurance methods, mostly designed to measure papers made of pure. native pulp only, can not reliably (or at all) be used to analyze or rank the quality of modern papers. Hence, introduction of new measurement techniques is necessary to assure and further develop the paper quality today and in the future. Paper formation , i.e. small scale (millimeter scale) variation of basis weight, is the most important quality parameter of paper-making due to its influence on practically all the other quality properties of paper. The ideal paper would be completely uniform so that the basis weight of each small point (area) measured would be the same. In practice, of course, this is not possible because there always exists relatively large local variations in paper. However, these small scale basis weight variations are the major reason for many other quality problems, including calender blacking uneven coating result, uneven printing result, etc. The traditionally used visual inspection or optical measurement of the paper does not give us a reliable understanding of the material variations in the paper because in modern paper making process the optical behavior of paper is strongly affected by using e.g. fillers, dye or coating colors. Futhermore, the opacity (optical density) of the paper is changed at different process stages like wet pressing and calendering. The greatest advantage of using beta transmission method to measure paper formation is that it can be very reliably calibrated to measure true basis weight variation of all kinds of paper and board, independently on sample basis weight or paper grade. This gives us the possibility to measure, compare and judge papers made of different raw materials, different color, or even to measure heavily calendered, coated or printed papers. Scientific research of paper physics has shown that the orientation of the top layer (paper surface) fibers of the sheet paly the key role in paper curling and cockling , causing the typical practical problems (paper jam) with modern fax and copy machines, electronic printing , etc. On the other hand, the fiber orientation at the surface and middle layer of the sheet controls the bending stiffness of paperboard . Therefore, a reliable measurement of paper surface fiber orientation gives us a magnificent tool to investigate and predict paper curling and coclking tendency, and provides the necessary information to finetune, the manufacturing process for optimum quality. many papers, especially heavily calendered and coated grades, do resist liquid and gas penetration very much, bing beyond the measurement range of the traditional instruments or resulting invonveniently long measuring time per sample . The increased surface hardness and use of filler minerals and mechanical pulp make a reliable, nonleaking sample contact to the measurement head a challenge of its own. Paper surface coating causes, as expected, a layer which has completely different permeability characteristics compared to the other layer of the sheet. The latest developments in sensor technologies have made it possible to reliably measure gas flow in well controlled conditions, allowing us to investigate the gas penetration of open structures, such as cigarette paper, tissue or sack paper, and in the low permeability range analyze even fully greaseproof papers, silicon papers, heavily coated papers and boards or even detect defects in barrier coatings ! Even nitrogen or helium may be used as the gas, giving us completely new possibilities to rank the products or to find correlation to critical process or converting parameters. All the modern paper machines include many on-line measuring instruments which are used to give the necessary information for automatic process control systems. hence, the reliability of this information obtained from different sensors is vital for good optimizing and process stability. If any of these on-line sensors do not operate perfectly ass planned (having even small measurement error or malfunction ), the process control will set the machine to operate away from the optimum , resulting loss of profit or eventual problems in quality or runnability. To assure optimum operation of the paper machines, a novel quality assurance policy for the on-line measurements has been developed, including control procedures utilizing traceable, accredited standards for the best reliability and performance.

An Outbreak of Epidemic Keratoconjunctivitis by Adenovirus Type 8 in a Neonatal Intensive Care Unit (신생아 중환자실에서의 아데노바이러스 8형에 의한 유행성 각결막염의 발생)

  • Park, Na-Ri-Mi;Na, Ji-Youn;Joung, Kyoung-Eun;Lee, Ji-Na;Kim, Ee-Kyung;Kim, Han-Suk;Kim, Seong-Joon;Song, Jung-Suk;Oh, Hyang-Soon;Lee, Hoan-Jong;Choi, Jung-Hwan
    • Neonatal Medicine
    • /
    • v.15 no.1
    • /
    • pp.44-53
    • /
    • 2008
  • Purpose : Epidemic keratoconjunctivitis (EKC) caused by adenovirus is a highly contagious disease, which has been reported as outbreaks involving adults in the community. However, there has been no report on EKC outbreak by adenovirus in a neonatal intensive care unit (NICU) in Korea. Aims of this study were to investigate the EKC outbreak by adenovirus type 8 in NICU and to confirm an effectiveness of polymerase chain reaction (PCR) for diagnosis. Methods : Conjunctival swab or nasopharyngeal aspirate specimens were taken from all patients and tested by viral culture and PCR. Adenovirus serotype was determined by sequencing of PCR product of selected region of hexon gene using the virus isolates or specimens. Results : An outbreak of EKC occurred which was involving 12 preterm infants in the NICU of the Seoul National University Children's Hospital between July 12th and August 1st, 2005. Three hospital staffs and one family member of the neonate were also affected. Adenovirus was detected in 12/12 (100%), 6/11 (54.5%) by PCR and virus culture, respectively. Eleven PCR-positive neonates were identified as serotype 8 by sequencing. The first affected 4 babies have had routine ROP (retinopathy of prematurity) examinations one week ago. While previous outbreaks were sustained for a few months, the event in our unit was controlled without complications in 3 weeks. Conclusion : We analyzed the EKC outbreak by adenovirus type 8 in NICU. Adenovirus serotype was identified by PCR and sequencing with high sensitivity for the first time in Korea, so we suggest this method can be very useful for rapid diagnosis and infection control.

Severe Pneumonia Caused by 2009 Pandemic Influenza A (H1N1) Virus in Children and Corticosteroid Treatment (소아에서 2009 신종 인플루엔자 A (H1N1) 중증 폐렴과 스테로이드 치료)

  • Sohn, Yu Rak;Kim, Jong Hee;Ma, Sang Hyuk;Lee, Kyung Yil;Kang, Jin Han
    • Pediatric Infection and Vaccine
    • /
    • v.18 no.2
    • /
    • pp.193-200
    • /
    • 2011
  • Purpose : The effect of corticosteroid on severe pneumonia caused by 2009 pandemic influenza (H1N1) A virus is controversial. This study was aimed to present the effects of early, short-term corticosteroid treatment for severe pneumonia with this virus infection. Methods : A retrospective analysis was performed on severe pneumonia patients (37 patients) who had severe respiratory distress at presentation requiring oxygen therapy and received intravenous methylprednisolone (MP, 8-10 mg/kg, divided in 4 doses/day for 2-3 days) with oseltamivir. The clinical and laboratory characteristics of the patients were evaluated through the medical records and chest radiographic findings. Results : The mean age and male-to-female ratio of the patients were 6.5${\pm}$2.9 years of age, and 3.4:1 (male 29 patients), respectively. The 5-9 aged group was predominant among the age groups (25 patients, 67.6%). Duration of fever prior to admission was 1.4${\pm}$0.6 days and dyspnea developed within 24 h after beginning of respiratory symptoms in all patients. All patients were previously healthy and received oseltamivir within 48 h. Thirteen patients (35.1%) developed dyspnea during oseltamivir treatment. Following MP infusion, all 37 patients including 13 progressive pneumonia patients during oseltamivir treatment showed an immediate halt in the progression of pneumonic infiltration with rapid clinical improvement. There were no side-effects following steroid use. Conclusion : For severe pneumonia patients, early corticosteroid treatment halted clinical exacerbation, and possibly prevented progression to acute respiratory distress syndrome. Further controlled clinical studies are needed for the role of corticosteroids and antivirals on severely affected patients with influenza virus infections.