• Title/Summary/Keyword: Rapid Calibration

Search Result 264, Processing Time 0.037 seconds

Determination of Chemical Composition of Toasted Burley Tobacco by Near Infrared Spectroscopy (근적외선분광법을 이용한 버어리 토스트엽의 화학성분 분석)

  • 김용옥;정한주;백순옥;김기환
    • Journal of the Korean Society of Tobacco Science
    • /
    • v.17 no.2
    • /
    • pp.177-183
    • /
    • 1995
  • This study was conducted to develop the most precise NIR(near infrared spectrometric) calibration for rapid determination of chemical composition in ground samples of toasted burley tobacco using stepwise, stepup, principal component regression(PCR), partial least square(PLS) and modified partial least square(MPLS) calibration method. The number of wavelength(W) selected by stepup multiple linear regression using: second derivative spectra was as follows: total sugar(TS)-4 W, nicotine-9 W, total nitrogen(TN)-2 W, ash-8 W, total volatile base(TVB)-5 W, chlorine4 W, L of color-6 W, a of color-6 W and b of color-7 W. Comparing the calibration equations followed by each chemical components, the most precise calibration equation was MPLS for 75, a and b of color, PLS for nicotine, ash, TVB, chlorine and L of color and stepup for TN. The standard error of calibration(SEC) and standard error of performance(SEP) between result of near infrared analysis and standard laboratory analysis were 0.18, 0.40% for 75, 0.06, 0.08% for nicotine, 0.18, 0.16% for TN, 0.33, 0.46% for ash, 0.04, 0.03% for TVB, 0.08, 0.06% for chlorine, 0.54, 0.58 for L of color, 0.22, 0.22 for a of color and 0.27, 0.27 for b of color, respectively. The SEC and SEP of ash and TVB were within allowable error of standard laboratory analysis, nicotine, TN and chlorine were 1.2-2.0 times and 75 were 2.1-4.0 times larger than allowable error of standard laboratory analysis. The ratio of SEC and SEP to mean were 1.5, 1.6% for L of color, 3.7, 3.8% for a of color and 1.8, 1.8% for b of color, respectively. Key words : burley tobacco chemistry, near infrared spectroscopy.

  • PDF

An Improved Calibration Method for the COCOMO II Post-Architecture Model

  • Yoon, Myoung-Young
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.5 no.2
    • /
    • pp.47-55
    • /
    • 2000
  • To date many software engineering cost models have been developed to predict cost, schedule, and effort of the software under development. The COCOMO Ⅱ is well- suited for the new software development life cycle such as non-sequential and rapid- development processes. The traditional regression approach based on the least square criterion is the most commonly used technique for empirical calibration in the COCOMO Ⅱ model. It has a few assumptions frequently violated by software engineering data sets. The source data is also generally imprecise in reporting size effort, and cost-driver ratings, particularly across different organizations. And that the outlier for the source data is a peculiarity and indicates a data point. To cope with difficulties, in this paper, we propose a new regression method for calibrating COCOMO Ⅱ post-architecture model based on the minimum relative error(MRE) criterion. The characteristic of the proposed method is insensitive to the extreme values of the data in the empirical calibration. As the experimental results, It is evident that our proposed calibration method MRE was shown to be superior to the traditional regression approach for model calibration, as illustrated by the values obtained for standard deviation(^σ), and prediction at level LPRED(L) measures.

  • PDF

Auto Calibration of Water Quality Modeling Using NGIS (NGIS자료와 연계한 수질모의 결과의 자동보정)

  • Han, Kun Yeun;Lee, Chang Hee;Kim, Kang Mo
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2004.05b
    • /
    • pp.1400-1403
    • /
    • 2004
  • The current industrial development and the Increase of population along Nakdong River have produced a rapid Increase of wastewater discharge. This has resulted in problem of water quality control and management. Although many efforts have been carried out, water quality has not significantly improved. The goal of this study is to design a NGIS-based water quality management system for the scientific water quality control and management in the Nakdong River. For general water quality analysis, QULA2E model was applied to the Nakdong River. A sensitivity analysis was made to determine significant parameters and an optimization was made to estimate optimal values. The calibration and verification were performed by using observed water quality data for Nakdong River. A water qualify management system for Nakdong River was made by connecting the QUAL2E model to ArcView. It allows a Windows-based Graphic User Interface(GUI) to implement all operation with regard to water quality analysis. The modeling system in this study will be an efficient NGIS for planning of water quality management.

  • PDF

Assessment of streamflow variation considering long-term land-use change in a watershed

  • Noh, Joonwoo;Kim, Yeonsu;Yu, Wansik;Yu, Jisoo
    • Korean Journal of Agricultural Science
    • /
    • v.48 no.3
    • /
    • pp.629-642
    • /
    • 2021
  • Land-use change has an important role in the hydrologic characteristics of watersheds because it alters various hydrologic components such as interception, infiltration, and evapotranspiration. For example, rapid urbanization in a watershed reduces infiltration rates and increases peak flow which lead to changes in the hydrologic responses. In this study, a physical hydrologic model the soil and water assessment tool (SWAT) was used to assess long-term continuous daily streamflow corresponding to land-use changes that occurred in the Naesungchun river watershed. For a 30-year model simulation, 3 different land-use maps of the 1990s, 2000s, and 2010s were used to identify the impacts of the land-use changes. Using SWAT-CUP (calibration and uncertainty program), an automated parameter calibration tool, 23 parameters were selected, optimized and compared with the daily streamflow data observed at the upstream, midstream and downstream locations of the watershed. The statistical indexes used for the model calibration and validation show that the model performance is improved at the downstream location of the Naesungchun river. The simulated streamflow in the mainstream considering land-use change increases up to -2 - 30 cm compared with the results simulated with the single land-use map. However, the difference was not significant in the tributaries with or without the impact of land-use change.

Precise Baseline Measurement and Computation of Correction Factor For EDM Instrument Calibration (EDM 장비의 검교정을 위한 정밀 기선장 관측 및 보정계수 산정)

  • 조재명;윤홍식;이원춘
    • Proceedings of the Korean Society of Surveying, Geodesy, Photogrammetry, and Cartography Conference
    • /
    • 2004.04a
    • /
    • pp.83-89
    • /
    • 2004
  • The electronic distance measurement instrument, first introduced in the 1950s has, since those early days, undergone continual refinement. Rapid advances in related technologies have provided lighter, smaller and more precise equipment. Understanding for the principle, the standardized observation technique and the precision of EDM instrument is mostly important to improve the quality and the reliability of by-product in the field of engineering and industrial surveying. Simple and accurate calibration is regularly and periodically necessary to maintenance the precision of EDM instrument. This paper describes the calculated example of zero error and scale error as a correction of EDM by applying the least square method to baseline observations. Here we deals also with the testing criteria for precision instrument testing according to different types of EDM instruments.

  • PDF

QL2-XP Model for the Automatic Calibration in Water Quality Modeling (하천 수질 매개변수의 자동보정을 위한 QL2-XP 모형 개발)

  • Han, Kun-Yeun;Park, Kyung-Ok
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2005.05b
    • /
    • pp.474-477
    • /
    • 2005
  • The Industrial development and the Increase in population have brought out a rapid increase of wastewater discharge. To deal with this matter, much estimate has been spend on construction and management of a large scale sewage treatment plant. Although every effort has been carried out, river water quality has no significantly improved. Especially. the aggravation of the water quality in dry season is brought out a serious social problem. The purpose of this study Is the development of an optimal water quality management technique considering the efficient control of the multiple pollutant load associated with the total pollutant load control. A GUI(Graphical User Interface) system named 'QL2-XP' model is developed by object-oriencted language for the user convenience and practical usage. Suggested GUI system consist of hydraulic analysis. water quality analysis, optimized model calibration processes, and postprocessing the simulation results.

  • PDF

A Study on the Vision-Based Inspection System for Ball-Stud (비전을 이용한 볼-스터드 검사 시스템에 관한 연구)

  • 장영훈;권태종;한창수;문영식
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.15 no.12
    • /
    • pp.7-13
    • /
    • 1998
  • In this paper, an automatic ball-stud inspection system has been developed using the computer-aided vision system. Index table has been used to get the rapid measurement and multi-camera has been used to get the high resolution in physical system. Camera calibration was suggested to perform the reliable inspection. Image processing and data analysis algorithms for ball stud inspection system have been investigated and were performed quickly with high accuracy. As a result, inspection system of a ball stud could be used with a high resolution in real time.

  • PDF

A Study of the B/STUD Inspection System Using the Vision System (비전을 이용한 B/STUD 검사 시스템에 관한 연구)

  • 장영훈;한창수
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1995.10a
    • /
    • pp.1120-1123
    • /
    • 1995
  • In this paper, an automatic B/STUD inspection system has been developed using the computer aided vision system. Index Table has been used to get the rapid measurement and multi-camera has been used to get the high resolution in mechanical system. Camera calibration was suggested to perform the reliable Inspection. Image processing and data analysis algorithms for B/STUD inspection system has been investigated and were performed quickly with high accuracy. As a result, Inspection system of a B/STUD can be measured with a high resolution in real time.

  • PDF

Application of the uncertainty for insertion loss measurement of silencers (소음기 감음 성능 불확도 산출 방법 연구)

  • Yu, Seung-Guk;Kim, Dae-Hyeon;Kim, Yeong-Chan;Kim, Du-Hun
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.1675-1680
    • /
    • 2000
  • Recently the uncertainty has been made rapid progress in various fields of industry but the uncertainty measurement method of acoustical test (i.e. Insertion loss, Absorption ratio, Transmission loss etc,) hasn't been established. In this study, the uncertainty of measurement method for ducted silencers is carried out according to ISO 7235. The standard uncertainty factors are composed of sound pressure level, microphone sensitivity and pistonphone calibration in this measurement. Sound pressure level is type A evaluation of uncertainty, microphone sensitivity and pistonphone calibration are type B evaluation of uncertainty. The combined standard uncertainty is calculated by two type evaluation. The expanded uncertainty is expressed by the combined standard uncertainty multiply k value which is yield the effective degree of freedom.

  • PDF

The enhancement of 3-dimensional positioning accuracy by measuring error factors for CNC machine tools (공작기계의 오차요소 측정을 통한 3차원 위치정밀도 향상)

  • 손진욱;서석환;정세용;이응석;위현곤
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 1994.10a
    • /
    • pp.260-265
    • /
    • 1994
  • Efforts have been devoted to developing rapid and accurate methods for measuring the errors of machine tools. The method os measurement and calibration of machine tool errors should be general and efficient. The objective of this study is to show in detail the full sequence from the measurement of errors factors to the verification of the positioning accuracy after compensation for the volumetric error. In this paper, we described the steps in measuring the volumetric error parameters, a general error model composed of error parameters, temperature, and the desired position. The validity of the error calibration methods proposed in this paper was tested using a vertical 3-axis CNC machine with a laser interferometer and a ball bar.

  • PDF