• 제목/요약/키워드: Ranging Error

Search Result 280, Processing Time 0.03 seconds

Inland ASF Measurement by Signal of the 9930M Station (9930M국 로란-C 신호를 이용한 내륙 ASF 측정 연구)

  • Yang, Sung-Hoon;Lee, Chang-Bok;Lee, Jong-Koo;Kim, Young-Jae;Lee, Sang-Jeong
    • Journal of Navigation and Port Research
    • /
    • v.34 no.8
    • /
    • pp.603-607
    • /
    • 2010
  • The LORAN system had been used widely and it was an essential navigation aid for ships in the ocean until the GPS is adopted actively. In particular, it was essential functionality for the ships to sail the oceans. According to the advancement of industry, however, the current accuracy of traditional Loran is insufficient for the utilization of harbour approach, land navigation, and the field of survey and timing. Therefore it is necessary that the study on the improvement of the positioning accuracy of Loran. The one of the improving methods is to measure and compensate the propagation time delay between the transmitter and user's receiver, which is called as additional secondary factor (ASF). In this study, we measured the ASF between the Pohang master transmitting station (9930M) and four points where locate within 33 km apart from the transmitting station, using the measuring technique of the absolute time delay without a time of coincidence (TOC) table. As the result of measurement, the ranging error caused by the propagation delay was about 210 m at 33 km, however it can be reduced up to 40 m with ASF compensation.

Mutation Analysis of Synthetic DNA Barcodes in a Fission Yeast Gene Deletion Library by Sanger Sequencing

  • Lee, Minho;Choi, Shin-Jung;Han, Sangjo;Nam, Miyoung;Kim, Dongsup;Kim, Dong-Uk;Hoe, Kwang-Lae
    • Genomics & Informatics
    • /
    • v.16 no.2
    • /
    • pp.22-29
    • /
    • 2018
  • Incorporation of unique barcodes into fission yeast gene deletion collections has enabled the identification of gene functions by growth fitness analysis. For fine tuning, it is important to examine barcode sequences, because mutations arise during strain construction. Out of 8,708 barcodes (4,354 strains) covering 88.5% of all 4,919 open reading frames, 7,734 barcodes (88.8%) were validated as high-fidelity to be inserted at the correct positions by Sanger sequencing. Sequence examination of the 7,734 high-fidelity barcodes revealed that 1,039 barcodes (13.4%) deviated from the original design. In total, 1,284 mutations (mutation rate of 16.6%) exist within the 1,039 mutated barcodes, which is comparable to budding yeast (18%). When the type of mutation was considered, substitutions accounted for 845 mutations (10.9%), deletions accounted for 319 mutations (4.1%), and insertions accounted for 121 mutations (1.6%). Peculiarly, the frequency of substitutions (67.6%) was unexpectedly higher than in budding yeast (~28%) and well above the predicted error of Sanger sequencing (~2%), which might have arisen during the solid-phase oligonucleotide synthesis and PCR amplification of the barcodes during strain construction. When the mutation rate was analyzed by position within 20-mer barcodes using the 1,284 mutations from the 7,734 sequenced barcodes, there was no significant difference between up-tags and down-tags at a given position. The mutation frequency at a given position was similar at most positions, ranging from 0.4% (32/7,734) to 1.1% (82/7,734), except at position 1, which was highest (3.1%), as in budding yeast. Together, well-defined barcode sequences, combined with the next-generation sequencing platform, promise to make the fission yeast gene deletion library a powerful tool for understanding gene function.

A new method for determining OBS positions for crustal structure studies, using airgun shots and precise bathymetric data (지각구조 연구에서 에어건 발파와 정밀 수심 자료를 이용한 OBS 위치 결정의 새로운 방법)

  • Oshida, Atsushi;Kubota, Ryuji;Nishiyama, Eiichiro;Ando, Jun;Kasahara, Junzo;Nishizawa, Azusa;Kaneda, Kentaro
    • Geophysics and Geophysical Exploration
    • /
    • v.11 no.1
    • /
    • pp.15-25
    • /
    • 2008
  • Ocean-bottom seismometer (OBS) positions are one of the key parameters in an OBS-airgun seismic survey for crustal structure study. To improve the quality of these parameters, we have developed a new method of determining OBS positions, using airgun shot data and bathymetric data in addition to available distance measurements by acoustic transponders. The traveltimes of direct water waves emitted by airgun shots and recorded by OBSs are used as important information for determining OBS locations, in cases where there are few acoustic transponder data (<3 sites). The new method consists of two steps. A global search is performed as the first step, to find nodes of the bathymetric grid that are the closest to explaining the observed direct water-wave traveltimes from airgun shots, and acoustic ranging using a transponder system. The use of precise 2D bathymetric data is most important if the bottom topography near the OBS is extremely rough. The locations of the nodes obtained by the first step are used as initial values for the second step, to avoid falling into local convergence minima. In the second step, a non-linear inverse method is executed. If the OBS internal clock shows large drift, a secondary correction for the OBS internal clock is obtained, as well as the OBS location, as final results by this method. We discuss the error and the influence of each measurement used in the determination of OBS location.

Ring Shear Characteristics of Waste Rock Materials in Terms of Water Leakage (누수유무에 따른 광산폐석의 링전단특성)

  • Jeong, Sueng Won
    • The Journal of Engineering Geology
    • /
    • v.26 no.3
    • /
    • pp.307-314
    • /
    • 2016
  • Shear characteristics of soils can be investigated using various types of shear stress measuring apparatus. Ring shear tests are often applied for examining the residual shear strength under the unlimited deformation. This paper presents drainage-consolidation-shear velocity dependent undrained shear strengths measured in terms of water leakage. A series of ring shear tests were performed under the constant normal stress (50 kPa) and controled shear velocity ranging from 0.01~1 mm/sec under the undrained condition. As a result, undrained shear strengths are dependent on shear velocity. It exhibits that straining hardening behavior is observed for the shear velocity lower than 0.1 mm/sec; however, the strain softening behavior is observed for the shear velocity higher than 0.1 mm/sec. Water leakage can cause the increase in shear stress irrespective of shear velocity. Shear stress increases with increasing amount of water leakage. It is due to the fact that the small grains and water flow out through the rubble edge in the ring shear box. Repetitive saturation and consolidation processes may minimize the error.

Review on The Measurement of Wood Shrinkage (목재수축률 측정에 대한 총설)

  • Lee, So Sun;So, Won-Tek;Jeong, Gi Young
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.746-756
    • /
    • 2015
  • The goal of this study was to review the wood shrinkage published in Journal of The Korean Wood Science and Technology from 1976 to 2015. Previous studies reported that shrinkage from Larix kaempferi in the tangential, radial, longitudinal directions ranged from 4.21%-9.79%, 2.09%-4.67%, 0.17%-0.33%, respectively. When different drying methods including closed cylinder drying, oven drying, and room temperature drying were used, volumetric shrinkage of Dipterocarpus grandiflorus was different, ranging from 31.6% to 21.0%. With an increment of the drying temperature of $115^{\circ}C$, $120^{\circ}C$, $125^{\circ}C$, the shrinkage of Larix kaempferi did not show a consistent trend. When sample size of Pinus densiflora was increased from $20{\times}20{\times}20mm$ to $100{\times}100{\times}100mm$, the tangential, radial and volumetric shrinkage decreased 2.61%, 1.32%, 0.80%, respectively. When a caliper having a sensitivity of 0.01 mm was used to measure $20mm^3$ specimen from Cryptomeria japonica, the measurement error occurred 1.97% in the radial direction and 35.7% in the longitudinal direction. From the previous studies, wood shrinkage could be influenced by sample size, drying method and measurement technique.

Real-time Implementation of the AMR Speech Coder Using $OakDSPCore^{\circledR}$ ($OakDSPCore^{\circledR}$를 이용한 적응형 다중 비트 (AMR) 음성 부호화기의 실시간 구현)

  • 이남일;손창용;이동원;강상원
    • The Journal of the Acoustical Society of Korea
    • /
    • v.20 no.6
    • /
    • pp.34-39
    • /
    • 2001
  • An adaptive multi-rate (AMR) speech coder was adopted as a standard of W-CDMA by 3GPP and ETSI. The AMR coder is based on the CELP algorithm operating at rates ranging from 12.2 kbps down to 4.75 kbps, and it is a source controlled codec according to the channel error conditions and the traffic loading. In this paper, we implement the DSP S/W of the AMR coder using OakDSPCore. The implementation is based on the CSD17C00A chip developed by C&S Technology, and it is tested using test vectors, for the AMR speech codec, provided by ETSI for the bit exact implementation. The DSP B/W requires 20.6 MIPS for the encoder and 2.7 MIPS for the decoder. Memories required by the Am coder were 21.97 kwords, 6.64 kwords and 15.1 kwords for code, data sections and data ROM, respectively. Also, actual sound input/output test using microphone and speaker demonstrates its proper real-time operation without distortions or delays.

  • PDF

dLoran Measurement in Yeongil Bay using the Pohang Loran-C (9930M) (포항 로란-C(9930M) 이용 영일만 dLoran 측정)

  • Lee, Chang Bok;Lee, Jong Koo;Lee, Young Kyu;Hwang, Sang-Wook;Lee, Sang Jeong;Yang, Sung-Hoon
    • Journal of Navigation and Port Research
    • /
    • v.38 no.3
    • /
    • pp.227-232
    • /
    • 2014
  • There are three essential components of eLoran: dLoran, data map of ASF, and the Loran data channel. Particularly, dLoran improves navigation accuracy, which is the core technology of eLoran systems. The requirement of HEA's absolute accuracy, less than 20 meters, can be satisfied via dLoran measurements and their corrections. In this study, dLoran measurements using the Pohang Loran-C (9930M) station signal were conducted at Yeongil Bay. We established a dLoran reference station at Homigot Management Office for navigation aids within the Bay. We estimated the effectiveness of the dLoran between the reference site (Homigot Management Office) and a test site (Heunghwan beach) by measuring TOAs. We verified that the TOA data measured at these two regions were highly correlated. The temporal differences in the data between the dLoran reference station and test site were about 10~30 ns per day, which is equivalent to a ranging error of 3~9 m. This result shows that eLoran can meet the requirement of 8~20 meters position accuracy for maritime HEA by correcting the ASF at the user's receiver.

Re-establishing the Antecedent Moisture Condition of NRCS-CN Method Considering Rainfall-Runoff Characteristics in Watershed Based on Antecedent 5-Day Rainfall (유역의 강우-유출 특성을 고려한 NRCS-CN 방법의 선행토양함수조건의 재설정: 선행5일강우량을 기준으로)

  • Yoo, Ji-Young;Moon, Geon-Woo;Ahn, Jae-Hyun;Kim, Tae-Woong
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.3
    • /
    • pp.849-858
    • /
    • 2014
  • The mount of antecedent 5-day rainfall (P5) is usually used to determine the antecedent soil moisture condition for estimating effective rainfall using the NRCS-CN method. In order to re-establish the threshold of P5 considering basin characteristics, this study investigated the sensitivity of the threshold of P5 to effective rainfall by comparing the corresponding observed direct runoff. The overall results indicate that the direct runoff estimated using the re-establihed threshold of P5 has smaller mean error (RMSE of 27.3 mm) than those using the conventional threshold (RMSE of 35.2 mm). In addition, after evaluating the effectiveness of threshold of P5 using the improvement index, the threshold re-established in this study improved the ability to estimate the direct runoff by 30% on average. This study also suggested to employ regression models using topographic indices to re-establish the threshold for ungauged basins. When using the re-established threshold from the regression model, the RMSE decreased ranging from 0.4 mm to 15.1 mm and the efficiency index of Nash and Sutcliffe increased up to 0.33.

A Practical standard Air Flow Generator System to Calibrate and Compare Performance of Two Different Respiratory Air Flow Measurement Modules (호흡기류 계측모듈의 교정과 성능 비교를 위한 실용적인 표준기류 생성 시스템)

  • Lee, In-Kwang;Park, Mi-Jung;Lee, Sang-Bong;Kim, Kyoung-Ok;Cha, Eun-Jong;Kim, Kyung-Ah
    • Journal of Biomedical Engineering Research
    • /
    • v.36 no.4
    • /
    • pp.115-122
    • /
    • 2015
  • A standard air flow generator system was developed to generate air flows of various levels simultaneously applied to two different air flow transducer modules. Axes of two identical standard syringes for spirometer calibration were connected with each other and driven by a servo-motor. Linear displacement transducer was also connected to the syringe axis to accurately acquire the volume change signal. The user can select either sinusoidal or square waveform of volume change and manually input any volume as well as maximal flow rate levels ranging 0~3 l and 0~15 l/s, respectively. Various volume and flow levels were input to operate the system, then the volume signal was acquired followed by numerical differentiation to obtain the air flow signal. The measured volumes and maximal air flow rates were compared with the user input data. The relative errors between the user-input and the measured stroke volumes were all within 0.5%, demonstrating very accurate driving of the system. In case of the maximal flow rate, relatively large error was observed when the syringe was driven very fast within a very short time duration. However, except for these few data, most measured flow rates revealed relative errors of approximately 2%. When the measure and user-input stroke volume and maximal flow rate data were analyzed by linear regression analysis, respectively, the correlation coefficients were satisfactorily higher than 0.99 (p < 0.0001). These results demonstrate that the servo-motor controls the syringes with enough accuracy to generate standard air flows. Therefore, the present system would be very much practical for calibration process as well as performance evaluation and comparison of two different air flow transducer modules.

Performance Analysis of Noncoherent OOK UWB Transceiver for LR-WPAN (저속 WPAN용 비동기 OOK 방식 UWB 송수신기 성능 분석)

  • Ki Myoungoh;Choi Sungsoo;Oh Hui-Myoung;Kim Kwan-Ho
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.30 no.11A
    • /
    • pp.1027-1034
    • /
    • 2005
  • IEEE802.15.4a, which is started to realize the PHY layer including high precision ranging/positioning and low data rate communication functions, requires a simple and low power consumable transceiver architecture. To satisfy this requirements, the simple noncoherent on-off keying (OOK) UWB transceiver with the parallel energy window banks (PEWB) giving high precision signal processing interface is proposed. The flexibility of the proposed system in multipath fading channel environments is acquired with the pulse and bit repetition method. To analyze the bit error rate (BER) performance of this proposed system, a noise model in receiver is derived with commonly used random variable distribution, chi-square. BER of $10^{-5}$ under the line-of-sight (LOS) residential channel is achieved with the integration time of 32 ns and signal to noise ratio (SNR) of 15.3 dB. For the non-line-of-sight (NLOS) outdoor channel, the integration time of 72 ns and SNR of 16.2 dB are needed. The integrated energy to total received energy (IRR) for the best BER performance is about $86\%$.