• 제목/요약/키워드: Range of period

검색결과 3,843건 처리시간 0.032초

SP816 박테리오파아지의 생리적 특성 (Physiological characterization of SP816 bacteriophage)

  • 이오형
    • 미생물학회지
    • /
    • 제24권2호
    • /
    • pp.161-167
    • /
    • 1986
  • Some of the physiological properties of Sp816 bacteriophage of Bacillus subtilis SNU816 were characterized. It could form plaques on either B. subtilis SNU816 or B. natto 8102, but not on any other bacillus strains investrgated. Its plaque morphology was circular with a diameter of less than 1.0mm and had a narrow halo surrounding the clear center. Its latent period was 34-36 min and had a burst size of 547. It was most stable at pH 6.0, and rapidly inactivated at $60^{\circ}C$ with a initial deaty rate of -0.216 $min^{-1}$. Host range, thermal inactivation rate at $60^{\circ}C$, pH stability, and UV sensitivity revealed that SP816 was quite different from any other phages investigated together but seemed to be rather related to B. natto phages.

  • PDF

양수장 용수공급 논 지대의 물수지 (Water Balance in a Paddy Field with Pumping Irrigation System)

  • 정운태;이근후;이인영
    • 한국농공학회:학술대회논문집
    • /
    • 한국농공학회 1998년도 학술발표회 발표논문집
    • /
    • pp.1-7
    • /
    • 1998
  • To investigate the water balance in a paddy rice field with the pumping station for irrigation water supply, flow measurements and analysis on various components of water balance were carried out. The investigated area is 103.7 ha, and the irrigation water was supplied for 102 days during the total irrigation period starting from June 1. It was found that the consumption rate was increased as the growing stage was progressed. The variation of evapotranspiration rate was shown same tendency as the consumption rate, while no apparent tendency was found in infiltration rate upon different growing stages. And the ground water input to the area was predominant during the early stage of growing period, while ground water output from the study area was predominant at the end of the growing stage. The range of return flow rate, the ratio of total outflow to total inflow in every decad, was 57.6 to 85.7%. These values are slightly higher than reported values from the other investigation projects.

  • PDF

A Study on the Patterns of the Late 19th Century Funerals

  • Kim, Kyung-Hee
    • 패션비즈니스
    • /
    • 제7권3호
    • /
    • pp.1-13
    • /
    • 2003
  • As a ritual that deals with the issues of human life and death, and that embodies complicated cultural implications, funerals have been an important material to refer to in considering the spiritual life as well as the social aspects of contemporary people. The present study on the 19th-century Western funerals is significant in that current funerals have been formed and changed from the ancient practice in a long historical background. The funeral patterns in 1890 to 1910, the period when reformatory movements started to appear in the custom concerning death, have been changed and fixed to be the current funeral custom. The range of the present study is limited to the characteristics of enbalmment, funeral processions and ceremonies, as well as the costumes for the mourning period. The research method employed in the study is the review of literature concerning death and funeral rituals, previous studies, domestic and international technical literature, and photographs or paintings.

주거 건물의 복사냉방시스템 적용에 관한 연구 (A Study on the Application of the Radiant Floor Cooling System in Residential Building)

  • 임재한;여명석;김광우
    • 한국주거학회논문집
    • /
    • 제15권3호
    • /
    • pp.73-82
    • /
    • 2004
  • The objective of this study is to demonstrate the potential of radiant cooling systems using Ondol as an alternative cooling system in residential buildings. For this purpose, computer simulation and model experiments have been performed for the system performance analysis regarding comfort, floor surface condensation, and supply water temperature. The results of this study is the following: In radiant floor cooling system, room air temperatures were maintained within the set temperature range of $\pm$1$^{\circ}C$ without any discomfort condition. And taking into account only the condensation occurrence, it was possible to achieve radiant floor cooling for a period of about 77% of the total cooling period in weather condition of Seoul. The minimum supply water temperature is about 15$^{\circ}C$, so renewable energy system such as ground heat exchange system can be used as an alternative in cooling source. Also, floor surface condensation can be prevented by integrating with the dehumidification system.

Proposed Treatment Protocol for Frostbite: A Retrospective Analysis of 17 Cases Based on a 3-Year Single-Institution Experience

  • Woo, Eun-Kyung;Lee, Jong Wook;Hur, Gi-Yeun;Koh, Jang-Hyu;Seo, Dong-Kook;Choi, Jai-Ku;Jang, Young-Chul
    • Archives of Plastic Surgery
    • /
    • 제40권5호
    • /
    • pp.510-516
    • /
    • 2013
  • Background This paper discusses the treatment protocol for patients with frostbite. Methods We performed a retrospective analysis of a series of 17 patients with second- and higher-degree frostbite who had been treated at our medical institution between 2010 and 2012. Results Our clinical series of patients (n=17) included 13 men and four women, whose mean age was $42.4{\pm}11.6$ years (range, 22-67 years). The sites of injury include the foot in six patients (35.3%), the hand in six patients (35.3%) and the facial region in five patients (29.4%). Seven patients with second-degree frostbite were completely cured with only conservative treatment during a mean period of $12.7{\pm}3.3$ days (range, 8-16 days). Of the five patients with third-degree frostbite, two underwent skin grafting following debridement, and the remaining three achieved a complete cure with conservative treatment during a mean period of $35{\pm}4.3$ days (range, 29-39 days). Five patients with fourth-degree frostbite were treated with surgical procedures including amputation. Conclusions With the appropriate conservative management in the early stage of onset, surgeons should decide on surgery after waiting for a sufficient period of time until the demarcation of the wound. Continuous management of patients is also needed to achieve functional recovery after a complete cure has been achieved. This should also be accompanied by patient education for the avoidance of re-exposure to cold environments.

FPSO의 횡요 감쇠 장치에 대한 고찰 (A Study on Roll Reduction Devices for FPSOs)

  • 박인규;양진호;신현수
    • 한국해양공학회:학술대회논문집
    • /
    • 한국해양공학회 2004년도 학술대회지
    • /
    • pp.30-35
    • /
    • 2004
  • Several roll motion reduction devices are reviewed and suggested for the application in FPSO. The firstly suggested solution is the shape of the bilge. The next is a bilge keel. The last suggestion is the ART (anti-rolling tank). Typical U-tube type ART is designed for a FPSO and examined extensively by model experiment. The model section was made of transparent acryl. Free decay test, forced oscillation test and wave test were carried out at a two-dimensional wave flume. U-tube type ART is effective only when the natural periods of ART and ship are same. Therefore, the divided U-tube type ART with split plate is suggested for the reduction of the roll motion of a FPSO over the wide range of the roll period.

  • PDF

304L 스테인리스 강의 플라즈마 질화처리 (Plasma Assisted Nitriding of Stainless Steel Type 304L)

  • 박정렬
    • 열처리공학회지
    • /
    • 제8권4호
    • /
    • pp.255-265
    • /
    • 1995
  • Stainless steel type 304L has been nitrided in the low pressure (600Pa) and high nitrogen (80% $N_2$+20% $H_2$) environment for 5 hours by the square-wave-pulsed-d.c. plasma as a function of temperature $400{\sim}550^{\circ}C$ and pulsation. At the lower temperature range of $400{\sim}500^{\circ}C$ and at the relatively high ratio of pulse duration to pulse period. "S-phase" has been developed in the form of thin nitrided surface layer which has many cracks, leading to be nearly impossible for the industrial anti-wear and anti-corrosion applications. At the higher temperature up to $550^{\circ}C$ with the increasing ratio of the pulse duration to pulse period up to $50{\mu}s/100{\mu}s$, the nitrided layer, whose growth rate has increased also, has been composed mainly of CrN and $Fe_4N$ phases and has become thick, uniform and nearly crack-free.

  • PDF

한반도 중부지방에서 관측된 1992-1993년 산성비의 특성과 공기 이동 경로 분석 (Trajectory Analysis on Acid Rain Observed in the Central Part of Korea During 1992 to 1993)

  • 전영신;조하만;권원태
    • 한국대기환경학회지
    • /
    • 제10권3호
    • /
    • pp.175-182
    • /
    • 1994
  • Backward trajectory analysis was carried out for 41 cases at 850 hPa level and 47 cases at 700 hPa level during the period from May 1992 to August 1993 in order to understand the impact of long-range transported pollutants from the neighboring countries on the distribution pattern of acid rain in Korea. The occurrence frequencies of acid rain were also investigated using the rainwater data observed at 5 stations in the central part of Korea, Kangwha, Seoul, Yangpyong, Hongchon, and Inje. The trajectory analysis showed that westerlies were dominant on 700 hPa level and southwesterlies on 850 hPa level in Korea. The pH values were also often lower when the trajectory was stagnant in the upper air over Korea. However, pH values were normally higher in all directions of flows during the Yellow Sand Period due to the increase of Positive ion components such as $Ca^{+2}$. The pH values were also normally higher when air flows from north or northeast.

  • PDF

교통량예측모형의 개발과 평가 (TRAFFIC-FLOW-PREDICTION SYSTEMS BASED ON UPSTREAM TRAFFIC)

  • 김창균
    • 대한교통학회:학술대회논문집
    • /
    • 대한교통학회 1995년도 제27회 학술발표회
    • /
    • pp.84-98
    • /
    • 1995
  • Network-based model were developed to predict short term future traffic volume based on current traffic, historical average, and upstream traffic. It is presumed that upstream traffic volume can be used to predict the downstream traffic in a specific time period. Three models were developed for traffic flow prediction; a combination of historical average and upstream traffic, a combination of current traffic and upstream traffic, and a combination of all three variables. The three models were evaluated using regression analysis. The third model is found to provide the best prediction for the analyzed data. In order to balance the variables appropriately according to the present traffic condition, a heuristic adaptive weighting system is devised based on the relationships between the beginning period of prediction and the previous periods. The developed models were applied to 15-minute freeway data obtained by regular induction loop detectors. The prediction models were shown to be capable of producing reliable and accurate forecasts under congested traffic condition. The prediction systems perform better in the 15-minute range than in the ranges of 30-to 45-minute. It is also found that the combined models usually produce more consistent forecasts than the historical average.

  • PDF

고속 프랙탈 영상압축을 위한 최적의 파이프라인 주기를 갖는 VLSI 어레이 구조 설계 (Design of VLSI Array Architecture with Optimal Pipeline Period for Fast Fractal Image Compression)

  • 성길영;우종호
    • 한국통신학회논문지
    • /
    • 제25권5A호
    • /
    • pp.702-708
    • /
    • 2000
  • 본 논문에서는 프랙탈 영상압축의 고속수행을 위한 최적의 파이프라인 주기를 갖는 일차원 VLSI 어레이를 설계했다. 고정분할 알고리즘을 변형하여 VLSI 어레이 설계에 적합하며 화질의 손상을 최소화하면서 압축율이 높은 알고리즘을 유도했다. 파이프라인의 각 세그먼트를 구성하는 PE의 연산시간을 가능한 균등하게 분포시켜 최적의 파이프라인의 주기를 얻었다. 이러한 결과로써 약 4배의 속도 향상을 얻을 수 있다. 정의역과 치역블럭의 입출력과 연산장치를 공유하여 입출력 핀의 수를 줄였다.

  • PDF