• Title/Summary/Keyword: Range of Application

Search Result 4,586, Processing Time 0.032 seconds

The Effects of Hold-relax Techniques after Inducing Delayed Muscle Pain on the Pain and Range of Motion of Joints (지연성 근육통 유발 후 유지-이완 기법이 통증과 관절가동범위에 미치는 영향)

  • Kim, Ji-Seon;Woo, Young-Keun;Ki, Kyong-Il
    • PNF and Movement
    • /
    • v.14 no.1
    • /
    • pp.15-21
    • /
    • 2016
  • Purpose: The purpose of the present study was to compare the effects of both general hold-relax techniques and hold-relax techniques using pumping on pain due to delayed muscle pain and on the range of motion (ROM) of joints. Methods: Thirty-nine young adult males and females were randomly assigned either to a hold-relax technique application group of 20 subjects or to a group of 19 subjects with hold-relax techniques applied using a pumping application. Tenderness thresholds, the ROM of joints, and pain intensities were measured on the biceps of the nondominant arm of the subjects in both groups before exercises were performed to induce delayed muscle pain. Tenderness thresholds were again measured 24hours, 48hours, and 72 hours after inducing delayed muscle pain. The relevant intervention methods were applied to the two groups after conducting the measurement at 48hours. As a statistical analysis method, repeated measure ANOVAs were conducted to examine the tenderness thresholds, ROMs of elbow joints, and pain intensities in the individual groups at the time points. Results: At 48 hours and 72 hours after application of the interventions, the general hold-relax technique application group showed greater changes in the tenderness thresholds, the ROMs of elbow joints, and the pain intensities than did the group applying hold-relax techniques using a pumping application (p>0.05). Conclusion: Based on the results of the present study, the application of hold-relax techniques is thought to have beneficial effects on pain resulting from delayed muscle pain and on limited ROMs of joints.

Empirical Study on Stereotype for Burner-Control Relationship of Four-Stove Gas Range for Koreans

  • Kee, Do-Hyung
    • Journal of the Ergonomics Society of Korea
    • /
    • v.31 no.3
    • /
    • pp.463-467
    • /
    • 2012
  • This study aims to empirically investigate population stereotype of burner-control linkage of four-stove gas range for Koreans. Background: The previous studies' results for gas range stereotypes were different depending upon methods adopted, i.e., whether using questionnaires, computer simulation or physical models. It is known that the physical model experiment should not be methodologically replaced by the computer simulation or paper-and-pencil tests. Stereotype of gas range for Koreans was surveyed based on questionnaires, but has not been dealt with by using physical models. Method: An experiment was conducted to investigate stereotype of four-burner gas range, in which 32 subjects participated and a real gas range available in the market was bought and used. Four types of burner-control linkage were used as independent variable, and reaction time as dependent variable. Results: ANOVA revealed that four types of burner-control linkage and subjects' gender were not significant on reaction time. Duncan's multiple range test showed that reaction times for type III was significantly lower than those for the other three types of burner-control linkage(${\alpha}$=0.05). Conclusion: It is concluded based on the results of this study that stereotype of gas range for Koreans is type III. This is in agreement with results of existing studies using questionnaire survey, while different from those based on physical models. Application: The results of this study would be useful as an ergonomic guideline when designing gas ranges or similar equipments for minimizing operation errors.

Application of Joint Mobilizing Chuna Following Tibial Plateau Fracture Surgery: A Study of Two Cases (경골 고평부 골절 수술 후 관절가동추나의 적용: 증례보고 2례)

  • Cho, Eunbyul;Cho, Nam geun
    • The Journal of Churna Manual Medicine for Spine and Nerves
    • /
    • v.15 no.2
    • /
    • pp.75-81
    • /
    • 2020
  • Objectives The purpose of this study was to report the effect of Korean medicine treatment, including the application of joint mobilizing chuna, by reporting two cases after tibial plateau fracture surgery. Methods Two patients with tibial plateau fractures were treated using joint mobilizing chuna, myofascial chuna, acupuncture, and herbal medication. The effect of the treatments was evaluated using the range of motion, manual muscle test, numeric rating scale, and Korean Knee Injury and Osteoarthritis Outcome Score. Results In both cases, the range of motion, muscle strength, and pain were significantly improved. In particular, the range of motion for knee joint flexion increased by 47° in case 1 and 30° (right) and 42° (left) in case 2. Conclusions Korean medicine treatment, especially joint mobilizing chuna, may be an effective intervention for rehabilitation after tibial plateau fracture surgery.

3 Stage 2 Switch Application for Transcranial Magnetic Stimulation

  • Ha, Dong-Ho;Kim, Whi-Young;Choi, Sun-Seob
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.234-239
    • /
    • 2011
  • Transcranial magnetic stimulation utilizes the method of controlling applied time and changing pulse by output pulse through power density control for diagnosis purposes. Transcranial magnetic stimulation can also be used in cases where diagnosis and treatment are difficult since output pulse shape can be changed. As intensity, pulse range, and pulse shape of the stimulation pulse must be changed according to lesion, the existing sine wave-shaped stimulation treatment pulse poses limitations in achieving various treatments and diagnosis. This study actualized a new method of transcranial magnetic stimulation that applies a 3 Stage 2 Switch( power semiconductor 2EA) for controlling pulse repetition rate by achieving numerous switching control of stimulation coil. Intensity, pulse range, and pulse shape of output can be freely changed to transform various treatment pulses in order to overcome limitations in stimulation treatment presented by the previous sine wave pulse shape. The method of freely changing pulse range by using 3 Stage 2 Switch discharge method is proposed. Pulse shape, composed of various pulse ranges, was created by grafting PFN (Pulsed Forming Network) through AVR AT80S8535 one-chip microprocessor technology, and application in transcranial magnetic stimulation was achieved to study the output characteristics of stimulation treatment pulse according to delaying time of the trigger signal applied in section switch.

Effective Application of Close-Range Photogrammetry with Digital Images in Industrial Precise Measurement (산업정밀측정에서 수치영상을 이용한 근접사진측량의 효율적 응용)

  • 이진덕
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.14 no.1
    • /
    • pp.17-25
    • /
    • 1996
  • The development of still video CCD cameras has simplified dramatically the digital imaging process. Still video cameras have flexibility that allows digital image acquisition and on-board image storage without being connected to a computer. The objective of this paper is to evaluate the performance of digital close-range photogrammetric system using the still video camera for dimensional inspection and structural monitoring being required in various industries. Some sub-pixel measurement techniques, which is indispensable for digital image measurement, were suggested. The author carried out the self-calibration of a high resolution DCS420 still video camera and then test application of a structure. The self-calibrating bundle adjustments resulted in object space accuracies which exceed 1 :46,000. It is ascertained that this digital close-range photogrammetric system has high accuracy potential and task effectiveness for industrial applications.

  • PDF

A Case Study On The Suitability Of Drawings Through Application Of BIM In Construction Management (건설사업관리 분야에서 BIM적용을 통한 도서의 적합성 검토 사례)

  • Park, Young-Jin;Song, Kyung-Chul
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2017.05a
    • /
    • pp.33-34
    • /
    • 2017
  • The purpose of this case study is to reduce the flaw and reconstruction occur at the level of construction by determining the propriety of estimate and error on a drawing and specification at working design level through case studies of BIM application at the level of design review. As a preliminary to apply BIM technology, it is needed to review the drawing, and then it is required to define BIM range by selecting the section in which construction error occurs frequently except for the type of part that is constructed repeatedly. At the execution level, the drawing is reviewed vertically, horizontally and spatially by proceeding structure and finish modeling on the defined BIM range, and also the propriety of estimate and error on the drawing and specification are examined. We aim to raise the completion rate, improve quality of construction, reduce the cost for construction and shorten period of construction by preparing for the error on the drawing and specification in advance through this review procedures.

  • PDF

A Study of Optimum Electromagnetic Field Analysis and Application of the Electret Sensor Using Computer Simulation (컴퓨터 시뮬레이션에 의한 일렉트렛트 센서의 최적 전계 해석과 응용)

  • 정동회;김상걸;김성렬;김용주;김영천;이준웅
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 1998.06a
    • /
    • pp.435-438
    • /
    • 1998
  • In this paper, Electret is formed to range voltage -5[kV] to -8[kV] by corona charging in PTFE film and sensor is manufactured by method of moments in sensing infra sonic. Charges of charged film are calculated also TSC measurement and induced potential of sensing electrode according to the charges is become aware of computer simulation. Electret Infra Sonic Transducer, which is designed and manufactured according to the potential and electric field simulation in using method of moments, is proved as it is effectively. Because sensitivity that measured under 10[Hz] is that average value of sensitivity rising rate is 6.34 [dB/oct] as average value is $\pm$1 [dB/oct] range -5[kV] to -8[kV] in corona charging film. As a result, it is believed that characteristic of acquired transducer can be application of medical treatment, industry, and animal life researches and the study of noise elimination, what's more, is required.

  • PDF

CONE ℭ-CLASS FUNCTIONS USING (CLRΓ𝔏)-PROPERTY ON CONE b-NORMED SPACES WITH APPLICATION

  • K. Maheshwaran;Arslan Hojat Ansari;Stojan N Radenovic;M.S. Khan;Yumnam Mahendra Singh
    • Korean Journal of Mathematics
    • /
    • v.32 no.3
    • /
    • pp.561-591
    • /
    • 2024
  • In this article, we demonstrate the conditions for the existence of common fixed points (CFP) theorems for four self-maps satisfying the common limit range (CLR)-property on cone b-normed spaces (CbNS) via ℭ-class functions. Furthermore, we have a unique common fixed point for two weakly compatible (WC) pairings. Towards the end, the existence and uniqueness of common solutions for systems of functional equations arising in dynamic programming are discussed as an application of our main result.

Application Utility Analysis of Series-cascaded Ring Resonators Based on SOI Slot Optical Waveguides in Integrated Optical Biochemical Sensor (SOI 슬롯 광도파로 기반 캐스케이드 링 공진기 바이오·케미컬 집적광학 센서의 효용성 해석)

  • Jang, Jaesik;Jung, Hongsik
    • Journal of Sensor Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.353-359
    • /
    • 2022
  • This study investigated via computational analysis the application utility of series-cascaded ring resonators based on silicon-on-insulator (SOI) slot optical waveguides in integrated optical biochemical sensors. The radii of the two rings in the series-cascaded ring resonators were 59.4 ㎛ and 77.6 ㎛ respectively, and the coupling distance was 0.5 ㎛. The series-cascaded ring resonators were computationally analyzed using FIMMProp and PICWave numerical software. The free spectral range (FSR), full width at half maximum (FWHM), sensitivity, and quality-factor (Q-factor) of the series-cascaded ring resonators were 12.2 nm, 0.134 nm, 4100 nm/RIU, and 11580, respectively, and the measurement range was calculated to be slightly smaller than 3×10-3 RIU. Although the measurement range was smaller than that of the single ring resonator, upon considering other characteristic parameters, the series-cascaded ring resonators are found to be more effective as integrated sensors than single ring resonators.

The Application of the GWLF model for Agricultural Small Watershed (농촌 소유역에 대한 GWLF 모형의 적용성 검토)

  • Hwang, Sye-Woon;Park, Seung-Woo
    • Proceedings of the Korean Society of Agricultural Engineers Conference
    • /
    • 2005.10a
    • /
    • pp.667-672
    • /
    • 2005
  • The objective of the study is to investigate the application of the mid-range model for agricultural ungaged small watershed. In this study, the need for the selection of an optimal model was presented, and the Feasibility of the GWLF(Generalized Watershed Loading Function) model was examined for agricultural small watershed. The study watershed covers 384ha, and the hydrologic and water quality data were monitored from 1996 to 2004. In the results of the simulation for the calibration period $(1996{\sim}1999)$ and verification $(2002{\sim}2004)$, $R^2$ were $0.70{\sim}0.91$ and RMSE was $2.11{\sim}5.71$. Then, the results of water quality simulation for SS, TN and TP, show that $R^2$ were 0.58, 0.47 and 0.62 respectively. This results were compared with the other research using the detailed models (SWAT, HSPF) for the same watershed and this showed the feasibility of mid-range model for the small watershed.

  • PDF