• Title/Summary/Keyword: Range of Application

Search Result 4,586, Processing Time 0.034 seconds

Enhancing Medium-Range Forecast Accuracy of Temperature and Relative Humidity over South Korea using Minimum Continuous Ranked Probability Score (CRPS) Statistical Correction Technique (연속 순위 확률 점수를 활용한 통합 앙상블 모델에 대한 기온 및 습도 후처리 모델 개발)

  • Hyejeong Bok;Junsu Kim;Yeon-Hee Kim;Eunju Cho;Seungbum Kim
    • Atmosphere
    • /
    • v.34 no.1
    • /
    • pp.23-34
    • /
    • 2024
  • The Korea Meteorological Administration has improved medium-range weather forecasts by implementing post-processing methods to minimize numerical model errors. In this study, we employ a statistical correction technique known as the minimum continuous ranked probability score (CRPS) to refine medium-range forecast guidance. This technique quantifies the similarity between the predicted values and the observed cumulative distribution function of the Unified Model Ensemble Prediction System for Global (UM EPSG). We evaluated the performance of the medium-range forecast guidance for surface air temperature and relative humidity, noting significant enhancements in seasonal bias and root mean squared error compared to observations. Notably, compared to the existing the medium-range forecast guidance, temperature forecasts exhibit 17.5% improvement in summer and 21.5% improvement in winter. Humidity forecasts also show 12% improvement in summer and 23% improvement in winter. The results indicate that utilizing the minimum CRPS for medium-range forecast guidance provide more reliable and improved performance than UM EPSG.

Detection system of Robust High Frequency Range via Noise Collection and Analysis

  • Chung, Myoungbeom
    • Journal of the Korea Society of Computer and Information
    • /
    • v.22 no.1
    • /
    • pp.71-76
    • /
    • 2017
  • Recently, there are various researches using inaudible high frequencies like as wireless communication based smart devices, data transmission algorithm, indoor positioning trace technologies. However, when they use high frequencies of inaudible range, they have a problem that the accuracy of data transmission with high frequencies was low because of interference from ambient noise in our real life. To solve this problem, in this paper, we proposed an application based on smart phone and server system for collection of ambient noise and detection of robust high frequency range. The server system could detect the robust high frequency range from statistical analysis of collected noise and the robust high frequency could avoid interference from ambient noise. We tested the proposed application's ability to gather noise and high frequencies for a certain period of time to evaluate performance. According to the testing results, we confirmed that the proposed application and server system could detect a robust high-frequency range via noise analysis in real life. Therefore, the proposed application and server could be a useful technology for future research on inaudible high frequencies.

Effects of Heat Therapy according to the Application Time among the Elderly with Osteoarthritis (퇴행성관절염 노인을 위한 온요법의 적용시기에 따른 효과)

  • Kim, Su-Hyeun;Kim, Myung-Hee;Kim, Ju-Sung
    • Journal of muscle and joint health
    • /
    • v.10 no.1
    • /
    • pp.7-18
    • /
    • 2003
  • This study was to investigate the effects(pain, discomfort, and range of motion) of heat therapy according to the application time among the elderly with osteoarthritis. Study participants were 27 elderly women, who were diagnosed as osteoarthritis, suffered from it for more than 6 months, and who were staying at a nursing home in Busan. The independent variable was heat therapy, which was applied for 20minutes, one time per week according to 3 timetable(before waking up, while in daily living, before going to bed) over 6 weeks. The dependent variables were pain and discomfort measured by 20 points visual analog scales, and range of extension and flexion measured by goniometery. The data were analyzed by descriptive statistics and repeated measures ANOVA. The results were as follows ; 1) There were significant differences for pain(F=9.77 p=.0001), discomfort(F=8.07 p=.001), range of extension(F=3.05 p=.05), and flexion(F=9.67 p=.0001) among heat therapy application times. 2) There were significant differences for pain(F=58.18 p=.0001), discomfort(F=63.68 p=.0001), range of extension(F=11.59 p=.001), and flexion(F=17.59 p=.0001) between before and after applying heat therapy. 3) There were not statistically significant differences for pain(F=.64 p=.531), discomfort(F=.18 p=.836), range of extension(F=1.33 p=.270), and fiexion(F=.26 p=.773) between before and after applying heat therapy according to the heat therapy application times. In conclusion, heat therapy was effective in reducing pain and discomfort, and in improving ROM for the elderly with osteoarthritis, but the effect of it was not different according to the time of application. We recommended further studies with larger sample size, longer and more repeatedly applied to investigate the effect of heat therapy according to the time of application.

  • PDF

A Reconfigurable Multiband FMCW Radar for Multipurpose Application (다목적활용을 위한 재구성이 가능한 다중대역 FMCW 레이다)

  • Kim, Byungjoon;Koo, Jong-seop;Kim, Duksoo;Nam, Sangwook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.26 no.12
    • /
    • pp.1112-1115
    • /
    • 2015
  • Recently, there have been advancements in radar related material technology, circuit design techniques and architecture design techniques. These have led to developments in radars' performance while decreasing the costs. Many studies have been carried out to apply radars to multipurpose application. In this study, a reconfigurable S-/X- band radar structure for multipurpose application is proposed and implemented. This radar measures a $51.2cm{\times}50.6cm$ target for 10 times from 2 m to 6 m range with 0.25 m distance step. The measured results show that this radar has 26.40 cm maximum range error, 5.63 cm average range error, and 0.24 cm range error variance at S-band while it has 8.53 cm maximum range error, 2.52 cm average range error, and 0.04 cm range error variance at X-band.

Differences in Body Temperatures according to Three Methods of cold Application (냉적용 방법에 따른 심부 및 피부온도변화)

  • 임난영;김진경
    • Journal of Korean Academy of Nursing
    • /
    • v.23 no.2
    • /
    • pp.157-169
    • /
    • 1993
  • The most effective modality for cold application and the length of the application have not been determined despite many studies about the use of cold. A quasi-experimental study was conducted to examine the most effective modality among three methods of cold application, the most effective length of time for the application and the continuing effect after each type of cold application. Thirty adult patients admitted to medical and neurosurgical unit and with high fever (above 38.2 ℃) were assigned randomly to each of three cold ap-plication methods : (a) ice bag: (b) cold compress; and (c) tepid water sponge bath. Each method was applied to the whole anterior surface except the face and neck with the patient in the supine pos-ition. Rectal temperatures and skin temperatures (mid chest, upper arm, thigh and leg) were measured be-fore each application and every 10 minutes during ,each application for a period of 60 minutes. They were also measured every 10 minutes for 30 minutes after each cold application was finished. The experiments were carried out from Dec. 22. 1992 through Feb. 26, 1993. The data were analysed using means, ANCOVA Sheffe test and Pearson's Correlation Coefficient. The results of this study are as follows : 1. There were no significant differences among the three cold application methods in the reduction of body temperature, 2. Among the ice bag, cold compress and tepid water sponge bath groups, the ice bag proved to be the most effective method for lowering skin temperature while the cold compress was least effective. 3. Both rectal and skin temperature continued to decrease during the 60 minutes of cold application, but the hunting phenomena was not observed at any of the cold application sites. 4. There were no significant correlations between mean rectal and skin temperatures. 5. Skin temperatures according to the cold application sites decreased to a range of 3.46℃ to 5.20℃ (mid chest), a range of 4.48℃ 4.96℃ (upper arm), a range of 3.86℃ to 5.05℃ (thigh), and a range of 5.42℃ -7.12℃ (leg ). 6. In continuing effect after the cold applications were finished, rectal temperatures according to ice bag, cold compress and tepid sponge bath decreased to 0.29℃, 0.23℃ and 0.09℃ respectively, while the mean skin temperatures increased to 2.39℃ , 2.04℃ and 2.22℃ respectively. In this experiment the ice bag was the most effective modality for lowering skin temperature. when-ever cold is applied for systemic effect, the continuing effect of cold should be considered. The determination of the most effective length of time for cold application needs further study.

  • PDF

A Modified Weighted Least Squares Range Estimator for ASM (Anti-Ship Missile) Application

  • Whang Ick-Ho;Ra Won-Sang;Ahn Jo-Young
    • International Journal of Control, Automation, and Systems
    • /
    • v.3 no.3
    • /
    • pp.486-492
    • /
    • 2005
  • A practical recursive WLS (weighted least squares) algorithm is proposed to estimate relative range using LOS (line-of-sight) information for ASM (anti-ship missile) application. Apart from the previous approaches based on the EKF (extended Kalman filter), to ensure good convergence properties in long range engagement situations, the proposed scheme utilizes LOS rate measurements instead of conventionally used LOS angle measurements. The estimation error property for the proposed filter is investigated and a simple error compensator is devised to enhance its estimation error performances. Simulation results indicate that the proposed filter produces very accurate range estimates with extremely small computations.

Usefulness of Smart Phone Application to Measure Cervical Range of Motion (목 관절가동범위 측정을 위한 스마트폰 어플리케이션의 유용성)

  • Chun-Yeop, Lee;Hae-Yoon, Song;Jung-Min, Lee;Moon-Young, Chang
    • The Journal of Korean society of community based occupational therapy
    • /
    • v.7 no.1
    • /
    • pp.17-24
    • /
    • 2017
  • Objective : The purpose of this study was to estimate the reliability of cervical range of motion measurement in healthy adults using smart phone application and goniometer that can be easily applicated in clinical setting. Methods : The cervical range of motion was measured as the flexion, extension, right rotation, left rotation, right lateral flexion, and left lateral flexion. To measure the reliability of intra-rater and inter-rater reliability, the same examiner performed two measurements and the other examiner performed once, total measurement were performed three times. The order of tests was randomized and two examiners didn't know the results of measurements. Results : Thirty healthy adults were participated. The result of this study shows that there were are no significant differences in all movements except the right lateral flexion in comparison of average angle of smart phone application and goniometer. The intra-rater reliability of smart phone application and goniometer showed ICC as .841~.958 and the inter-rater reliability showed ICC as .720~.944 for all movements. Conclusion : These results suggest that smart phone application and goniometer have proven to be reliable in measuring the cervical range of motion. Smart phone application can be used as a useful tool in clinical setting due to fast and accurate measurements of cervical range of motion.

A vision system for autonomous material handling by static and dynamic range finding (정적 및 동적 range 검출에 의한 원료 처리 자동화용 vision 시스템)

  • 안현식;최진태;이관희;신기태;하영호
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.10
    • /
    • pp.59-70
    • /
    • 1997
  • Until now, considerable progress has been made in the application of range finding techanique performing direct 3-D measurement from the object. However, ther are few use of the method in the area of the application of material handing. We present a range finding vision system consisting of static and dynamic range finders to automate a reclaimer used for material handling. A static range finder detects range data of the front part of the piles of material, and a height map is obtained from the proposed image processing algorithm. The height map is used to calculate the optimal job path as features for required information for material handling function. A dynamic range finder attached on the side of the arm of the reclaimer detects the change of the local properties of the material with the handling function, which is used for avoiding collision and detecting the ending point for changing direction. the developed vision systm was applied to a 1/20 simulator and the results of test show that it is appropriate to use for automating the material handling.

  • PDF

Design of Snubber Capacitor for Equalization of Voltage Sharing in Series Connected SiC MOSFETs

  • Min, Juhwa;Suh, Yongsug
    • Proceedings of the KIPE Conference
    • /
    • 2017.07a
    • /
    • pp.188-189
    • /
    • 2017
  • There has been a growing demand for power semiconductor switches equipped with high-voltage blocking capability of kV range and fast-switching characteristics of ns range in various plasma application. This paper investigates the application of SiC MOSFETs in the particular plasma application which requires the blocking voltage of 4.5kV and the switching transient time of less than 100ns. In order to meet the required blocking voltage, the series connection of multiple SiC MOSFETs is adopted in this paper. Also, snubber capacitors are employed to equalize the voltage sharing among the series connected SiC MOSFETs. The simulation and experimental result successfully verifies the application of SiC MOSFETs and snubber capacitors in the plasma application requiring high-voltage and fast-switching load dynamics.

  • PDF

The Response of a Wide-Range Oxygen Sensor to the Flow of Misfired Gas and Its Application for the Misfire Detection (실화가스 흐름에 대한 광역 산소센서의 응답특성 및 이를 이용한 실화감지)

  • 정영교;최상민;배충식;명차리
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.8 no.2
    • /
    • pp.41-49
    • /
    • 2000
  • To understand the signal fluctuation of a wide-range oxygen sensor installed at the exhaust confluence point, when a misfiring is triggered in a cylinder, the steady state and the transient response characteristics of the sensor to the flow of the misfired gas were investigated quantitatively. It was recognized that the steady state output voltage of the sensor increased higher when it contacted the misfired gas even though the fueling condition was the same as the normal combustion case and this characteristic enabled the application of the wide-range oxygen sensor for the misfire detection. The transient response was compared at different engine speeds and it was found that the response speed increased with the engine speed. The signal fluctuation was also estimated quantitatively, using these steady state and transient response of the sensor, and the estimated signal showed satisfactory correlation with the measurements.

  • PDF