• Title/Summary/Keyword: Range measurement

Search Result 4,379, Processing Time 0.035 seconds

The relationships between lead exposure indicies and urinary δ-ALA by HPLC and colorimetric method in lead exposure workers (연노출근로자에 있어서 흡광광도법과 HPLC법에 의한 요중 δ-ALA 배설량과 연노출지표들 간의 관련성)

  • Ahn, Kyu-Dong;Lee, Sung-Soo;Hwangbo, Young;Lee, Gab-Soo;Yeon, You-Yong;Kim, Yong-Bae;Lee, Byung-Kook
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.6 no.1
    • /
    • pp.77-87
    • /
    • 1996
  • In order to compare the difference of the measurement of delta aminolevulinic acid(${\delta}$-ALA) in urine between HPLC method(HALA) and colorimetric method(CALA), and also to provide useful information for the new diagnostic criteria of ${\delta}$-ALA in urine in lead poisoning, if at all possible in the future, authors studied 234 male lead workers who were selected from 7 storage battery factories, 3 secondary smelting industries, and 2 litharge making industries. Study subjects were selected on the basis of blood Zinc protoporphyrin(ZPP) level from low to high concentration to cover wide range of lead exposure. Study variables for this study were ${\delta}$-ALA measured by two different methods, blood lead(PbB), and blood ZPP. The results were as follows: 1. There was very high correlation between ${\delta}$-ALA measured by two method(r = 0.989 : HALA = -0.8194 + 0.8110 ${\times}$ CALA), but the value of CALA was measured about 2mg/L greater than HALA. 2. While the correlations of ${\delta}$-ALA by two method with blood lead and blood ZPP were 0.46 and 0.37 respectively, they were increased to 0.63 and 0.57 if ${\delta}$-ALA values were log-transformed. 3. Simple linear regression of ${\delta}$-ALA measured by two method on ZPP were as follows: CALA = 2.0421 + 0.0341 ${\times}$ ZPP ($R^2=0.1385$ p = 0.0001) HALA = 0.8006 + 0.0280 ${\times}$ ZPP ($R^2=0.1389$ p = 0.0001) 4. Simple linear regression of ${\delta}$-ALA measured by two method on PbB were as follows: CALA = - 0.4134 + 0.1545 ${\times}$ PbB ($R^2=0.2085$ p = 0.0001) HALA = -1.2893 + 0.1287 PbB ($R^2=0.2154$ p = 0.0001), 5. Simple linear regression of log-transformed ${\delta}$-ALA by two method on ZPP and PbB were as follows: logHALA = 0.3078 + 0.0060 ZPP ($R^2=0.3329$ p = 0.0001) logCALA = 1.0189 + 0.0044 ZPP ($R^2=0.3290$ p = 0.0001) logHALA = -0.0221 + 0.0246 PbB ($R^2=0.4046$ p = 0.0001) logCALA = 0.7662 + 0.0184 PbB ($R^2=0.4108$ p = 0.0001) 6. The cumulative percent of colorimetric method to detect lead workers whose value of PbS and ZPP were over screening level such as $40{\mu}/dl$ and $100{\mu}/dl$ respectively was higher than HPLC method if cut-off level of ${\delta}$-ALA for screening of lead poisoning was 5 mg/L. But if cut-off level of ${\delta}$-ALA measured by HPLC was reduced to 3 mg/L which is compatible to 5 mg/L of ${\delta}$-ALA measured by colorimetric method, there were good agreement between two methods and showed dose-response relationship with other lead exposure indices such as PbB and ZPP.

  • PDF

Development and Research into Functional Foods from Hydrolyzed Whey Protein Powder with Sialic Acid as Its Index Component - I. Repeated 90-day Oral Administration Toxicity Test using Rats Administered Hydrolyzed Whey Protein Powder containing Normal Concentration of Sialic Acid (7%) with Enzyme Separation Method - (Sialic Acid를 지표성분으로 하는 유청가수분해단백분말의 기능성식품 개발연구 - I. 효소분리로 7% Siailc Acid가 표준적으로 함유된 유청가수분해단백분말(7%)의 랫드를 이용한 90일 반복경구투여 독성시험 평가 연구 -)

  • Noh, Hye-Ji;Cho, Hyang-Hyun;Kim, Hee-Kyong
    • Journal of Dairy Science and Biotechnology
    • /
    • v.34 no.2
    • /
    • pp.99-116
    • /
    • 2016
  • We herein performed animal safety assessment in accordance with Good Laboratory Practice (GLP) regulations with the aim of developing sialic acid from glycomacropeptide (hereafter referred to as "GMP") as an index ingredient and functional component in functional foods. GMP is a type of whey protein derived from milk and a safe food, with multiple functions, such as antiviral activity. A test substance was produced containing 7% (w/w) sialic acid and mostly-hydrolyzed whey protein (hereafter referred to as "7%-GNANA") by enzymatic treatment of substrate GMP. The maximum intake test dose level was selected based on 5,000 mg/kg/day dose set for male NOEL (no-observed-effect-level) and female NOAEL (no-observed-adverse-effect-level) determined by a dose-range finding (DRF) test (GLP Center of Catholic University of Daegu, Report No. 15-NREO-001) that was previously conducted with the same test substance. To evaluate the toxicity of a repeated oral dose of the test substance in connection with the previous DRF study, 1,250, 2,500, and 5,000 mg/kg of the substance were administered by a probe into the stomachs of 6-week-old SPF Sprague-Dawley male and female rats for 90 d. Each test group consisted of 10 male and 10 female rats. To determine the toxicity index, all parameters, such as observation of common signs; measurements of body weight and food consumption; ophthalmic examination; urinalysis, electrolyte, hematological, and serum biochemical examination; measurement of organ weights during autopsy; and visual and histopathological examinations were conducted according to GLP standards. After evaluating the results based on the test toxicity assessment criteria, it was determined that NOAEL of the test substance, 7%-GNANA, was 5,000 mg/kg/day, for both male and female rats. No animal death was noted in any of the test groups, including the control group, during the study period, and there was no significant difference associated with test substance, as compared with the control group, with respect to general symptoms, body weight changes, food consumption, ophthalmic examination, urinalysis, hematological and serum biochemical examination, and electrolyte and blood coagulation tests during the administration period (P<0.05). As assessed by the effects of the test substance on organ weights, food consumption, autopsy, and histopathological safety, change in kidney weight as an indicator of male NOAEL revealed up to 20% kidney weight increase in the high-dose group (5,000 mg/kg/day) compared with the change in the control group. However, it was concluded that this effect of the test substance was minor. In the case of female rats, reduction of food consumption, increase of kidney weight, and decrease of thymus weight were observed in the high-dose group. The kidney weight increased by 10.2% (left) and 8.9% (right) in the high-dose group, with a slight dose-dependency compared with that of the control group. It was observed that the thymus weight decreased by 25.3% in the high-dose group, but it was a minor test substance-associated effect. During the autopsy, botryoid tumor was detected on the ribs of one subject in the high-dose group, but we concluded that the tumor has been caused by a naturally occurring (non-test) substance. Histopathological examination revealed lesions on the kidney, liver, spleen, and other organs in the low-dose test group. Since these lesions were considered a separate phenomenon, or naturally occurring and associated with aging, it was checked whether any target organ showed clear symptoms caused by the test substance. In conclusion, different concentrations of the test substance were fed to rats and, consequently, it was verified that only a minor effect was associated with the test substance in the high-dose (5,000 mg/kg/day) group of both male and female rats, without any other significant effects associated with the test substance. Therefore, it was concluded that NOAEL of 7%-GNANA (product name: Helicobactrol) with male and female rats as test animals was 5,000 mg/kg/day, and it thus was determined that the substance is safe for the ultimate use as an ingredient of health functional foods.

Inhomogeneity correction in on-line dosimetry using transmission dose (투과선량을 이용한 온라인 선량측정에서 불균질조직에 대한 선량 보정)

  • Wu, Hong-Gyun;Huh, Soon-Nyung;Lee, Hyoung-Koo;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.23 no.3
    • /
    • pp.139-147
    • /
    • 1998
  • Purpose: Tissue inhomogeneity such as lung affects tumor dose as well as transmission dose in new concept of on-line dosimetry which estimates tumor dose from transmission dose using the new algorithm. This study was carried out to confirm accuracy of correction by tissue density in tumor dose estimation utilizing transmission dose. Methods: Cork phantom (CP, density $0.202\;gm/cm^3$) having similar density with lung parenchyme and polystyrene phantom (PP, density $1.040\;gm/cm^3$) having similar density with soft tissue were used. Dose measurement was carried out under condition simulating human chest. On simulating AP-PA irradiation, PPs with 3 cm thickness were placed above and below CP, which had thickness of 5, 10, and 20 cm. On simulating lateral irradiation, 6 cm thickness of PP was placed between two 10 cm thickness CPs additional 3 cm thick PP was placed to both lateral sides. 4, 6, and 10 MV x-ray were used. Field size was in the range of $3{\times}3$ cm through $20{\times}20$ cm, and phantom-chamber distance (PCD) was 10 to 50 cm. Above result was compared with another sets of data with equivalent thickness of PP which was corrected by density. Result: When transmission dose of PP was compared with equivalent thickness of CP which was corrected with density, the average error was 0.18 (${\pm}0.27$) % for 4 MV, 0.10 (${\pm}0.43$) % for 6 MV, and 0.33 (${\pm}0.30$) % for 10 MV with CP having thickness of 5 cm. When CP was 10 cm thick, the error was 0.23 (${\pm}0.73$) %, 0.05 (${\pm}0.57$) %, and 0.04 (${\pm}0.40$) %, while for 20 cm, error was 0.55 (${\pm}0.36$) %, 0.34 (${\pm}0.27$) %, and 0.34 (${\pm}0.18$) % for corresponding energy. With lateral irradiation model, difference was 1.15 (${\pm}1.86$) %, 0.90 (${\pm}1.43$) %, and 0.86 (${\pm}1.01$) % for corresponding energy. Relatively large difference was found in case of PCD having value of 10 cm. Omitting PCD with 10 cm, the difference was reduced to 0.47 (${\pm}$1.17) %, 0.42 (${\pm}$0.96) %, and 0.55 (${\pm}$0.77) % for corresponding energy. Conclusion When tissue inhomogeneity such as lung is in tract of x-ray beam, tumor dose could be calculated from transmission dose after correction utilizing tissue density.

  • PDF

Development of Adjustable Head holder Couch in H&N Cancer Radiation Therapy (두경부암 방사선 치료 시 Set-Up 조정 Head Holder 장치의 개발)

  • Shim, JaeGoo;Song, KiWon;Kim, JinMan;Park, MyoungHwan
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.26 no.1
    • /
    • pp.43-50
    • /
    • 2014
  • In case of all patients who receive radiation therapy, a treatment plan is established and all steps of treatment are planned in the same geometrical condition. In case of head and neck cancer patients who undergo simulated treatment through computed tomography (CT), patients are fixed onto a table for planning, but laid on the top of the treatment table in the radiation therapy room. This study excogitated and fabricated an adjustable holder for head and neck cancer patients to fix patient's position and geometrical discrepancies when performing radiation therapy on head and neck cancer patients, and compared the error before and after adjusting the position of patients due to difference in weight to evaluate the correlation between patients' weight and range of error. Computed tomography system(High Advantage, GE, USA) is used for phantom to maintain the supine position to acquire the images of the therapy site for IMRT. IMRT 4MV X-rays was used by applying the LINAC(21EX, Varian, U.S.A). Treatment planning system (Pinnacle, ver. 9.1h, Philips, Madison, USA) was used. The setup accuracy was compared with each measurement was repeated five times for each weight (0, 15, and 30Kg) and CBCT was performed 30 times to find the mean and standard deviation of errors before and after the adjustment of each weight. SPSS ver.19.0(SPSS Inc., Chicago, IL,USA) statistics program was used to perform the Wilcoxon Rank test for significance evaluation and the Spearman analysis was used as the tool to analyze the significance evaluation of the correlation of weight. As a result of measuring the error values from CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.4{\pm}0.8mm$, $0.8{\pm}0.4mm$, 0 for 0Kg before the adjustment. In 15Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.2{\pm}0.8mm$, $1.2{\pm}0.4mm$, $2.0{\pm}0.4mm$. After adjusting position was X,Y,Z axis was $0.2{\pm}0.4mm$, $0.4{\pm}0.5mm$, $0.4{\pm}0.5mm$. In 30Kg CBCT before and after adjusting the position due to the weight difference, X,Y,Z axis was $0.8{\pm}0.4mm$, $2.4{\pm}0.5mm$, $4.4{\pm}0.8mm$. After adjusting position was X,Y,Z axis was $0.6{\pm}0.5mm$, $1.0{\pm}0mm$, $0.6{\pm}0.5mm$. When the holder for the head and neck cancer was used to adjust the ab.0ove error value, the error values from CBCT were $0.2{\pm}0.8mm$ for the X axis, $0.40{\pm}0.54mm$ for Y axis, and 0 for Z axis. As a result of statistically analyzing each value before and after the adjustment the value was significant with p<0.034 at the Z axis with 15Kg of weight and with p<0.038 and p<0.041 at the Y and Z axes respectively with 30Kg of weight. There was a significant difference with p<0.008 when the analysis was performed through Kruscal-Wallis in terms of the difference in the adjusted values of the three weight groups. As it could reduce the errors, patients' reproduction could be improved for more precise and accurate radiation therapy. Development of an adjustable device for head and neck cancer patients is significant because it improves the reproduction of existing equipment by reducing the errors in patients' position.

The Effect of Glucocorticoid on the Change of Nitric Oxide and Cytokine Levels in Induced Sputum from Patients with Bronchial Asthma (기관지 천식 환자에서 부신피질 스테로이드 투여 전후 유도객담내 Nitric Oxide 및 Cytokine의 변화)

  • Kim, Tae-Yon;Yoon, Hyeong-Kyu;Choi, Young-Mee;Lee, Sook-Young;Kwon, Soon-Seog;Kim, Young-Kyoon;Kim, Kwan-Hyoung;Moon, Hwa-Sik;Park, Sung-Hak;Song, Jeong-Sup
    • Tuberculosis and Respiratory Diseases
    • /
    • v.48 no.6
    • /
    • pp.922-931
    • /
    • 2000
  • Background : It has been well known that bronchia1 asthma is a chronic airway inflammatory disorder. Recently, sputum induced with hypertonic saline was introduced as a simple and useful nonivasive medium to investigate airway inflammation and symptom severity in patients with asthma. We examined the eosinophil, eosinophil cationic protein (ECP), interleukin(IL)-3, IL-5, granulocyte-macrophage colony-stimulating facta (GM-CSF), and nitric oxide (NO) derivatives in induced sputum from patients with bronchia1 asthma in order to determine the role of NO and various inflammatory cytokines as a useful markers of airway inflammation or changes in pulmonary function tests and symptoms. Methods : A total 30 patients with bronchia1 asthma received oral prednisolone 30 mg daily for 2 weeks. Forced expiratory volume in one second ($FEV_1$), total blood eosinophil count and induced sputum eosinophil count, ECP, IL-3, IL-5, GM-CSF, and NO derivatives were determined before and after the administration of prednisolone. Results : Of the 30 patients, 13 (43.3%) were male and 17 (56.7%) were female. The mean age of patients was 41.8 years (range 19-64 years). Two patients could not produce sputum at the second study and 3 could not be followed up after their first visit. Two weeks after the prednisolone administration, there was a significant increase in $FEV_1$ (% of predicted value) from 78.1$\pm$20.6 % to 90.3$\pm$ 18.3 % (P<0.001). The eosinophil percentages in induced sputum were significantly decreased after treatment with prednisolone, with values of 56.1$\pm$27.2 % versus 29.6$\pm$21.3 % (P<0.001), and ECP were $134.5\pm68.1\;{\mu}g/L$ versus $41.5\pm42.4\;{\mu}g/L$ (P<0.001) respectively. After the prednisolone treatments, the eotaxin concentration also showed a decreasing tendency from 26.7$\pm$12.8 pg/ml to 21.7$\pm$8.7 pg/ml. There was a decreasing tendency but no significant differences in total blood eosinophil count (425.7$\pm$265.9 vs 287.7$\pm$294.7) and in the concentration of NO derivatives ($70.4\pm44.6{\mu}mol/L$ vs $91.5\pm48.3\;{\mu}mol/L$) after the prednisolone treatments. IL-3, IL-5, GM-CSF were undetectable in the sputum of most subjects either before the prednisolone treatments or after the treatments. Before the prednisolone treatments, a significant inverse correlation was observed between FEV1 and sputum ECP (r=-D.364, P<0.05) and there was a significant correlation between sputum eosinophils and eotaxin (r=0.369, P<0.05) Conclusion : The eotaxin and ECP concentration in induced sputum may be used as markers of airway inflammation after treatments in bronchia1 asthma. In addition, the measurement of sputum eosinophil percent ages is believed to be a simple method displaying the degree of airway inflammation and airway obstruction before and after the prednisolone treatment in bronchia1 asthma. However, unlike exhaled NO, the examination of NO derivatives with Griess reaction in induced sputum is considered an ineffective marker of changing airway inflammation and obstructing symptoms.

  • PDF

Determination of Minimal Pressure Support Level During Weaning from Pressure Support Ventilation (압력보조 환기법으로 기계호흡 이탈시 최소압력보조(Minimal Pressure Support) 수준의 결정)

  • Jung, Bock-Hyun;Koh, Youn-Suck;Lim, Chae-Man;Lee, Sang-Do;Kim, Woo-Sung;Kim, Dong-Soon;Kim, Won-Dong
    • Tuberculosis and Respiratory Diseases
    • /
    • v.45 no.2
    • /
    • pp.380-387
    • /
    • 1998
  • Background: Minimal pressure support(PSmin) is a level of pressure support which offset the imposed work of breathing(WOBimp) developed by endotracheal tube and ventilator circuits in pressure support ventilation While the lower applied level of pressure support compared to PSmin could induce respiratory muscle fatigue, the higher level than PSmin could keep respiratory muscle rest resulting in prolongation of weaning period during weaning from mechanical ventilation PSmin has been usually applied in the level of 5~10 cm$H_2O$, but the accurate level of PSmin is difficult to be determinated in individual cases. PSmin is known to be calculated by using the equation of "PSmin = peak inspiratory flow rate during spontaneus ventilation$\times$total ventilatory system resistance", but correlation of calculated PSmin and measured PSmin has not been known. The objects of this study were firstly to assess whether customarily applied pressure support level of 5~10 cm$H_2O$ would be appropriate to offset the imposed work of breathing among the patients under weaning process, and secondly to estimate the correlation between the measured PSmin and calculated PSmin. Method : 1) Measurement of PSmin : Intratracheal pressure changes were measured through Hi-Lo jet tracheal tube (8mm in diameter, Mallinckroft, USA) by using pulmonary monitor(CP-100 pulmonary monitor, Bicore, USA), and then pressure support level of mechanical ventilator were increased until WOBimp was reached to 0.01 J/L or less. Measured PSmin was defined as the lowest pressure to make WOBimp 0.01 J/L or less. 2) Calculation of PSmin : Peak airway pressure(Ppeak), plateau airway pressure(Pplat) and mean inspiratory flow rate of the subjects were measured on volume control mode of mechanical ventilation after sedation. Spontaneous peak inspiratory flow rates were measured on CPAP mode(O cm$H_2O$). Thereafter PSmin was calculated by using the equation "PSmin = peak inspiratory flow rate$\times$R, R = (Ppeak-Pplat)/mean inspiratory flow rate during volume control mode on mechanical ventilation". Results: Sixteen patients who were considered as the candidate for weaning from mechanical ventilation were included in the study. Mean age was 64(${\pm}14$) years, and the mean of total ventilation times was 9(${\pm}4$) days. All patients except one were males. The measured PSmin of the subjects ranged 4.0~12.5cm$H_2O$ in 14 patients. The mean level of PSmin was 7.6(${\pm}2.5\;cmH_2O$) in measured PSmin, 8.6 (${\pm}3.25\;cmH_2O$) in calculated PSmin Correlation between the measured PSmin and the calculated PSmin is significantly high(n=9, r=0.88, p=0.002). The calculated PSmin show a tendancy to be higher than the corresponding measured PSmin in 8 out of 9 subjects(p=0.09). The ratio of measured PSmin/calculated PSmin was 0.81(${\pm}0.05$). Conclusion: Minimal pressure support levels were different in individual cases in the range from 4 to 12.5 cm$H_2O$. Because the equation-driven calculated PSmin showed a good correlation with measured PSmin, the application of equation-driven PSmin would be then appropriate compared with conventional application of 5~10 cm$H_2O$ in patients under difficult weaning process with pressure support ventilation.

  • PDF

Evaluation of the Usefulness of Exactrac in Image-guided Radiation Therapy for Head and Neck Cancer (두경부암의 영상유도방사선치료에서 ExacTrac의 유용성 평가)

  • Baek, Min Gyu;Kim, Min Woo;Ha, Se Min;Chae, Jong Pyo;Jo, Guang Sub;Lee, Sang Bong
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.32
    • /
    • pp.7-15
    • /
    • 2020
  • Purpose: In modern radiotherapy technology, several methods of image guided radiation therapy (IGRT) are used to deliver accurate doses to tumor target locations and normal organs, including CBCT (Cone Beam Computed Tomography) and other devices, ExacTrac System, other than CBCT equipped with linear accelerators. In previous studies comparing the two systems, positional errors were analysed rearwards using Offline-view or evaluated only with a Yaw rotation with the X, Y, and Z axes. In this study, when using CBCT and ExacTrac to perform 6 Degree of the Freedom(DoF) Online IGRT in a treatment center with two equipment, the difference between the set-up calibration values seen in each system, the time taken for patient set-up, and the radiation usefulness of the imaging device is evaluated. Materials and Methods: In order to evaluate the difference between mobile calibrations and exposure radiation dose, the glass dosimetry and Rando Phantom were used for 11 cancer patients with head circumference from March to October 2017 in order to assess the difference between mobile calibrations and the time taken from Set-up to shortly before IGRT. CBCT and ExacTrac System were used for IGRT of all patients. An average of 10 CBCT and ExacTrac images were obtained per patient during the total treatment period, and the difference in 6D Online Automation values between the two systems was calculated within the ROI setting. In this case, the area of interest designation in the image obtained from CBCT was fixed to the same anatomical structure as the image obtained through ExacTrac. The difference in positional values for the six axes (SI, AP, LR; Rotation group: Pitch, Roll, Rtn) between the two systems, the total time taken from patient set-up to just before IGRT, and exposure dose were measured and compared respectively with the RandoPhantom. Results: the set-up error in the phantom and patient was less than 1mm in the translation group and less than 1.5° in the rotation group, and the RMS values of all axes except the Rtn value were less than 1mm and 1°. The time taken to correct the set-up error in each system was an average of 256±47.6sec for IGRT using CBCT and 84±3.5sec for ExacTrac, respectively. Radiation exposure dose by IGRT per treatment was measured at 37 times higher than ExacTrac in CBCT and ExacTrac at 2.468mGy and 0.066mGy at Oral Mucosa among the 7 measurement locations in the head and neck area. Conclusion: Through 6D online automatic positioning between the CBCT and ExacTrac systems, the set-up error was found to be less than 1mm, 1.02°, including the patient's movement (random error), as well as the systematic error of the two systems. This error range is considered to be reasonable when considering that the PTV Margin is 3mm during the head and neck IMRT treatment in the present study. However, considering the changes in target and risk organs due to changes in patient weight during the treatment period, it is considered to be appropriately used in combination with CBCT.

Comparison of One-day and Two-day Protocol of $^{11}C$-Acetate and $^{18}F$-FDG Scan in Hepatoma (간암환자에 있어서 $^{11}C$-Acetate와 $^{18}F$-FDG PET/CT 검사의 당일 검사법과 양일 검사법의 비교)

  • Kang, Sin-Chang;Park, Hoon-Hee;Kim, Jung-Yul;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.2
    • /
    • pp.3-8
    • /
    • 2010
  • Purpose: $^{11}C$-Acetate PET/CT is useful in detecting lesions that are related to livers in the human body and leads to a sensitivity of 87.3%. On the other hand, $^{18}F$-FDG PET/CT has a sensitivity of 47.3% and it has been reported that if both $^{18}F$-FDG and $^{11}C$-Acetate PET/CT are carried out together, their cumulative sensitivity is around 100%. However, the normal intake of the pancreas and the spleen in $^{11}C$-Acetate PET/CT can influence the $^{18}F$-FDG PET/CT leading to an inaccurate diagnosis. This research was aimed at the verification of the usefulness of how much influence these two radioactive medical supplies can cause on the medical images through comparative analysis between the one-day and two-day protocol. Materials and Methods: This research was carried out based on 46 patients who were diagnosed with liver cancer and have gone through the PET/CT (35 male, 11 female participants, average age: $54{\pm}10.6$ years, age range: 29-69 years). The equipment used for this test was the Biograph TruePoint40 PET/CT (Siemens Medical Systems, USA) and 21 participants who went through the one-day protocol test were first given the $^{11}C$-Acetate PET/CT and the $^{18}F$-FDG PET/CT, the latter exactly after one hour. The other 25 participants who went through the two-day protocol test were given the $^{11}C$-Acetate PET/CT on the first day and the $^{18}F$-FDG PET/CT on the next day. These two groups were then graded comparatively by assigning identical areas of interest of the pancreas and the spleen in the $^{18}F$-FDG images and by measuring the Standard Uptake Value (SUV). SPSS Ver.17 (SPSS Inc., USA) was used for statistical analysis, where statistical significance was found through the unpaired t-test. Results: After analyzing the participants' medical images from each of the two different protocol types, the average${\pm}$standard deviation of the SUV of the pancreas carried out under the two-day protocol were as follows: head $1.62{\pm}0.32$ g/mL, body $1.57{\pm}0.37$ g/mL, tail $1.49{\pm}0.33$ g/mL and the spleen $1.53{\pm}0.28$ g/mL. Whereas, the results for participants carried out under the one-day protocol were as follows: head $1.65{\pm}0.35$ g/mL, body $1.58{\pm}0.27$ g/mL, tail $1.49{\pm}0.28$ g/mL and the spleen $1.66{\pm}0.29$ g/mL. Conclusion: It was found that no statistical significant difference existed between the one-day and two-day protocol SUV in the pancreas and the spleen (p<0.05), and nothing which could be misconceived as false positive were found from the PET/CT medical image analysis. From this research, it was also found that no overestimation of the SUV occurred from the influence of $^{11}C$-Acetate on the $^{18}F$-FDG medical images where those two tests were carried out for one day. This result was supported by the statistical significance of the SUV of measurement. If $^{11}C$-Acetate becomes commercialized in the future, the diagnostic ability of liver diseases can be improved by $^{18}F$-FDG and one-day protocol. It is from this result where tests can be accomplished in one day without the interference phenomenon of the two radioactive medical supplies and furthermore, could reduce the waiting time improving customer satisfaction.

  • PDF

Consumer Responses to Retailer's Location-based Mobile Shopping Service : Focusing on PAD Emotional State Model and Information Relevance (유통업체의 위치기반 모바일 쇼핑서비스 제공에 대한 소비자 반응 : PAD 감정모델과 정보의 상황관련성을 중심으로)

  • Lee, Hyun-Hwa;Moon, Hee-Kang
    • Journal of Distribution Research
    • /
    • v.17 no.2
    • /
    • pp.63-92
    • /
    • 2012
  • This study investigated consumer intention to use a location-based mobile shopping service (LBMSS) that integrates cognitive and affective responses. Information relevancy was integrated into pleasure-arousal-dominance (PAD) emotional state model in the present study as a conceptual framework. The results of an online survey of 335 mobile phone users in the U.S. indicated the positive effects of arousal and information relevancy on pleasure. In addition, there was a significant relationship between pleasure and intention to use a LBMSS. However, the relationship between dominance and pleasure was not statistically significant. The results of the present study provides insight to retailers and marketers as to what factors they need to consider to implement location-based mobile shopping services to improve their business performance. Extended Abstract : Location aware technology has expanded the marketer's reach by reducing space and time between a consumer's receipt of advertising and purchase, offering real-time information and coupons to consumers in purchasing situations (Dickenger and Kleijnen, 2008; Malhotra and Malhotra, 2009). LBMSS increases the relevancy of SMS marketing by linking advertisements to a user's location (Bamba and Barnes, 2007; Malhotra and Malhotra, 2009). This study investigated consumer intention to use a location-based mobile shopping service (LBMSS) that integrates cognitive and affective response. The purpose of the study was to examine the relationship among information relevancy and affective variables and their effects on intention to use LBMSS. Thus, information relevancy was integrated into pleasure-arousal-dominance (PAD) model and generated the following hypotheses. Hypothesis 1. There will be a positive influence of arousal concerning LBMSS on pleasure in regard to LBMSS. Hypothesis 2. There will be a positive influence of dominance in LBMSS on pleasure in regard to LBMSS. Hypothesis 3. There will be a positive influence of information relevancy on pleasure in regard to LBMSS. Hypothesis 4. There will be a positive influence of pleasure about LBMSS on intention to use LBMSS. E-mail invitations were sent out to a randomly selected sample of three thousand consumers who are older than 18 years old and mobile phone owners, acquired from an independent marketing research company. An online survey technique was employed utilizing Dillman's (2000) online survey method and follow-ups. A total of 335 valid responses were used for the data analysis in the present study. Before the respondents answer any of the questions, they were told to read a document describing LBMSS. The document included definitions and examples of LBMSS provided by various service providers. After that, they were exposed to a scenario describing the participant as taking a saturday shopping trip to a mall and then receiving a short message from the mall. The short message included new product information and coupons for same day use at participating stores. They then completed a questionnaire containing various questions. To assess arousal, dominance, and pleasure, we adapted and modified scales used in the previous studies in the context of location-based mobile shopping service, each of the five items from Mehrabian and Russell (1974). A total of 15 items were measured on a seven-point bipolar scale. To measure information relevancy, four items were borrowed from Mason et al. (1995). Intention to use LBMSS was captured using two items developed by Blackwell, and Miniard (1995) and one items developed by the authors. Data analyses were conducted using SPSS 19.0 and LISREL 8.72. A total of usable 335 data were obtained after deleting the incomplete responses, which results in a response rate of 11.20%. A little over half of the respondents were male (53.9%) and approximately 60% of respondents were married (57.4%). The mean age of the sample was 29.44 years with a range from 19 to 60 years. In terms of the ethnicity there were European Americans (54.5%), Hispanic American (5.3%), African-American (3.6%), and Asian American (2.9%), respectively. The respondents were highly educated; close to 62.5% of participants in the study reported holding a college degree or its equivalent and 14.5% of the participants had graduate degree. The sample represents all income categories: less than $24,999 (10.8%), $25,000-$49,999 (28.34%), $50,000-$74,999 (13.8%), and $75,000 or more (10.23%). The respondents of the study indicated that they were employed in many occupations. Responses came from all 42 states in the U.S. To identify the dimensions of research constructs, Exploratory Factor Analysis (EFA) using a varimax rotation was conducted. As indicated in table 1, these dimensions: arousal, dominance, relevancy, pleasure, and intention to use, suggested by the EFA, explained 82.29% of the total variance with factor loadings ranged from .74 to .89. As a next step, CFA was conducted to validate the dimensions that were identified from the exploratory factor analysis and to further refine the scale. Table 1 exhibits the results of measurement model analysis and revealed a chi-square of 202.13 with degree-of-freedom of 89 (p =.002), GFI of .93, AGFI = .89, CFI of .99, NFI of .98, which indicates of the evidence of a good model fit to the data (Bagozzi and Yi, 1998; Hair et al., 1998). As table 1 shows, reliability was estimated with Cronbach's alpha and composite reliability (CR) for all multi-item scales. All the values met evidence of satisfactory reliability in multi-item measure for alpha (>.91) and CR (>.80). In addition, we tested the convergent validity of the measure using average variance extracted (AVE) by following recommendations from Fornell and Larcker (1981). The AVE values for the model constructs ranged from .74 through .85, which are higher than the threshold suggested by Fornell and Larcker (1981). To examine discriminant validity of the measure, we again followed the recommendations from Fornell and Larcker (1981). The shared variances between constructs were smaller than the AVE of the research constructs and confirm discriminant validity of the measure. The causal model testing was conducted using LISREL 8.72 with a maximum-likelihood estimation method. Table 2 shows the results of the hypotheses testing. The results for the conceptual model revealed good overall fit for the proposed model. Chi-square was 342.00 (df = 92, p =.000), NFI was .97, NNFI was .97, GFI was .89, AGFI was .83, and RMSEA was .08. All paths in the proposed model received significant statistical support except H2. The paths from arousal to pleasure (H1: ${\ss}$=.70; t = 11.44), from information relevancy to intention to use (H3 ${\ss}$ =.12; t = 2.36), from information relevancy to pleasure (H4 ${\ss}$ =.15; t = 2.86), and pleasure to intention to use (H5: ${\ss}$=.54; t = 9.05) were significant. However, the path from dominance to pleasure was not supported. This study investigated consumer intention to use a location-based mobile shopping service (LBMSS) that integrates cognitive and affective responses. Information relevancy was integrated into pleasure-arousal-dominance (PAD) emotional state model as a conceptual framework. The results of the present study support previous studies indicating that emotional responses as well as cognitive responses have a strong impact on accepting new technology. The findings of this study suggest potential marketing strategies to mobile service developers and retailers who are considering the implementation of LBMSS. It would be rewarding to develop location-based mobile services that integrate information relevancy and which cause positive emotional responses.

  • PDF