• Title/Summary/Keyword: Range estimation

Search Result 1,991, Processing Time 0.033 seconds

Clinical Estimation of Corrected State with Change in Vertex Distance (정점간거리 변화에 따른 교정상태의 임상 평가)

  • Kim, Jung-Hee;Lee, Hak-Jun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.1
    • /
    • pp.25-30
    • /
    • 2010
  • Purpose: This study was conducted to estimate the changes of corrected diopter and corrected visual acuity with the change in vertex distance. Also we aimed to provide basic data for refraction test. Methods: Using the trial lens, we measured the corrected diopter and corrected visual acuity after performing binocular balance test. We measured the changes of corrected diopter and corrected visual acuity in change of vertex distance. We analyzed statistical significance and relations between vertex distance and corrected diopter and corrected visual acuity. Results: There was no difference in corrected diopter with the change of vertex distance within -1.00D, but the corrected diopter increased with it over - 1.25D. In particular, the change of diopter was largest when the vertex distance increased 15 mm. At over 11.00D, there was large changes of diopter with the changes of vertex distance at 5 mm, 10 mm and 15 mm. On correlation analysis between the vertex distance and the corrected diopter, there was strong correlation (r=0.999 at 5 mm increase of vertex distance, r=0.982 at 10 mm increase and r=0.957 at 15 mm increase) and also there was significant (p<0.01). At the change of visual acuity in increased of vertex distance, the range of a decrease in visual acuity was large when the changes of vertex distance was largest. On correlation analysis between the vertex distance and the corrected visual acuity, there was strong correlation (r=0.969 at 5 mm increase of vertex distance, r=0.985 at 10 mm increase and r=0.994 at 15 mm increase) and also there was significant (p<0.01). Conclusions: The vertex distance was very important at the refraction test and at wearing spectacle. On correlation analysis between the vertex distance and the corrected diopter, and the corrected visual acuity, there was strong correlation and statistically significant. Therefore, the vertex distance should be kept at the refraction using trial lens, and the best fitting was made not to slipping forward, and so we suggested regular refitting of spectacle and the managing method of spectacle were educated to the spectacle wearers.

Studies on Feed Intake and Nutrient Utilization of Sheep under Two Housing Systems in a Semi-arid Region of India

  • Bhatta, Raghavendra;Swain, N.;Verma, D.L.;Singh, N.P.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.17 no.6
    • /
    • pp.814-819
    • /
    • 2004
  • An investigation was carried out to study the effect of two housing systems on feed intake and nutrient utilization of sheep in a semi-arid region of India. Two types of housing managements were adopted. The first was a shed- 20'${\times}$10' structure with all the four sides of 6' chain link fencing with central height of 10'. The roof was covered with asbestos sheets, with mud floorings. The second was an open corral- 20'${\times}$10' open space with all the four sides covered with 6' chain link fencing. Thirty-four (32 ewes and 2 rams) sheep were grazed together on a 35 ha plot of native range. All the sheep were grazed as a flock from 08:00 to 17:00 h during the yearlong study. The flock was divided into two groups (16 ewes+1 ram) in the evening and housed according to two housing systems (Shed and Open Corral). Three digestion trials were conducted during three defined seasons of monsoon, winter and summer seasons to determine the effect of housing on nutrient intake and utilization. Blood samples were collected in three seasons for the estimation of hemoglobin and glucose. Dry and wet bulb temperatures were recorded at 06:00 A.M. and 09:00 P.M. using suitable thermometers both inside the shed and in the open corral and temperature humidity index (THI) was calculated. There was significant (p<0.05) difference in the THI between shed and open corral in all the seasons, indicating that the shed was always warmer compared to open corral. The daily dry matter intake (DMI, g/d) was 965, 615 and 982 in sheep housed under shed and 971, 625 and 1,001 in those housed in open corral during monsoon, winter and summer season, respectively. These differences were however non-significant (p>0.05). The digestibility of DM was 45.92, 45.13 and 50.30 in sheep housed under shed and 43.64, 45.02 and 55.02 in sheep housed in open corral during monsoon, winter and summer seasons, respectively. There was no significant (p>0.05) difference in the digestibility of nutrients in sheep maintained under shed and in open corral. Blood Hb concentration was 13.97, 14.13 and 13.15 in sheep housed under shed and 15.27, 13.63 and 14.82 in those kept in open corral, whereas blood glucose concentration was 59.67, 59.70 and 52.33 in sheep under shed and 61.00, 61.00 and 57.83 in open corral, during monsoon, winter and summer, respectively. There was also no significant effect of housing on the body weight changes, wool yield and survivability in ewes. Although housing had no significant effect on nutrient intake, their utilization and blood parameters, there was significant effect on the physiological responses and energy expenditure of sheep maintained under the two housing systems (Bhatta et al., 2004). It can be concluded from this study that the housing systems didn't have any significant effect on the nutrient intake and utilization of native breed like Malpura, which were well adapted to the hot semi-arid conditions of India. However, while deciding provisions for housing of different breeds of sheep (both crossbred and native) parameters like physiological responses, energy expenditure, health conditions and overall economics of the systems should be taken into consideration.

Koreanized Analysis System Development for Groundwater Flow Interpretation (지하수유동해석을 위한 한국형 분석시스템의 개발)

  • Choi, Yun-Yeong
    • Journal of the Korean Society of Hazard Mitigation
    • /
    • v.3 no.3 s.10
    • /
    • pp.151-163
    • /
    • 2003
  • In this study, the algorithm of groundwater flow process was established for koreanized groundwater program development dealing with the geographic and geologic conditions of the aquifer have dynamic behaviour in groundwater flow system. All the input data settings of the 3-DFM model which is developed in this study are organized in Korean, and the model contains help function for each input data. Thus, it is designed to get detailed information about each input parameter when the mouse pointer is placed on the corresponding input parameter. This model also is designed to easily specify the geologic boundary condition for each stratum or initial head data in the work sheet. In addition, this model is designed to display boxes for input parameter writing for each analysis condition so that the setting for each parameter is not so complicated as existing MODFLOW is when steady and unsteady flow analysis are performed as well as the analysis for the characteristics of each stratum. Descriptions for input data are displayed on the right side of the window while the analysis results are displayed on the left side as well as the TXT file for this results is available to see. The model developed in this study is a numerical model using finite differential method, and the applicability of the model was examined by comparing and analyzing observed and simulated groundwater heads computed by the application of real recharge amount and the estimation of parameters. The 3-DFM model is applied in this study to Sehwa-ri, and Songdang-ri area, Jeju, Korea for analysis of groundwater flow system according to pumping, and obtained the results that the observed and computed groundwater head were almost in accordance with each other showing the range of 0.03 - 0.07 error percent. It is analyzed that the groundwater flow distributed evenly from Nopen-orum and Munseogi-orum to Wolang-bong, Yongnuni-orum, and Songja-bong through the computation of equipotentials and velocity vector using the analysis result of simulation which was performed before the pumping started in the study area. These analysis results show the accordance with MODFLOW's.

Effect of Storage Temperature and Water Activity on Antioxidant Activities of Powdered Green Tea Extracts (분말녹차 추출물의 항산화 활성에 미치는 수분활성도 및 저장온도의 효과)

  • Choi, Gwi-Nam;Jeong, Chang-Ho;Kim, Ji-Hye;Kwak, Ji-Hyun;Shin, Young-Hee;Lee, Seung-Cheol;Cho, Sung-Hwan;Choi, Sung-Gil;Heo, Ho-Jin
    • Food Science and Preservation
    • /
    • v.16 no.3
    • /
    • pp.333-341
    • /
    • 2009
  • The antioxidant properties of green tea leaves and powder extracts were determined using several tests including estimation of reducing power, DPPH(1,1-diphenyl-2- picrylhydrazyl) radical-scavenging activity, and FRAP(Ferric reducing/antioxidant power) assay. All tests indicated that extracts of green tea powder had higher antioxidant activities than extracts of green tea leaves, and the activities were concentration-dependent. However, each test yielded somewhat different results with respect to storage conditions. The reducing power of green tea leaves was highest at $1,000{\mu}g/mL$, storage at $4^{\circ}C$, and an Aw(water activity) value of 0.23. However, the reducing power of green tea powder, assayed at $1,000{\mu}g/mL$, was high under all storage conditions(with variations in temperature and Aw), and was about 1.5.2-fold greater than that of green tea leaves. Radical-scavenging activity, as assessed by the DPPH assay, increased in a dose-dependent manner over the range $15{\sim}125{\mu}g/mL$. At higher concentrations, activities were $80{\sim}90%$ of maximal were attained. The FRAP activity of green tea extract also increased with rising concentration. Particularly in the case of green tea leaves, antioxidant activity was most greatest with storage at $-20^{\circ}C$ and Aw values of 0.69 and 0.23 when assayed at a concentration of $1,000{\mu}g/mL$. These results indicate that the most important factor during storage of green tea is not the Aw value but rather temperature, and that use of refrigeration($4^{\circ}C$) is preferable to increase or maintain the antioxidant activities of biological components in green tea.

A Practical Application and Development of Carbon Emission Factors for 4 Major Species of Warm Temperate Forest in Korea (난대지역 주요 4개 수종의 탄소배출계수 개발 및 적용)

  • Son, Yeong Mo;Kim, Rae Hyun;Kang, Jin Taek;Lee, Kwang Su;Kim, So Won
    • Journal of Korean Society of Forest Science
    • /
    • v.103 no.4
    • /
    • pp.593-598
    • /
    • 2014
  • In this study, we developed the carbon emission factors for 4 major species of warm-temperate region in Korea, and tried to provide their carbon emissions and removals estimates using these carbon emission factors. We selected Castanopsis cuspidata, Camellia japonica, Quercus acuta and Quercus glauca as target species and derived their carbon emission factors. The basic wood density that serve as one of the carbon emission factors were 0.583 for Castanopsis cuspidata, 0.657 for Camellia japonica, 0.833 for Quercus acuta and 0.763 for Quercus glauca and their uncertainties ranged from 5.3 to 17.9%. Biomass expansion factors were calculated as well: 1.386 for Castanopsis cuspidata, 2.621 for Camellia japonica, 1.701 for Quercus acuta and 2.123 for Quercus glauca and associated uncertainties varied from 14.7 to 30.5%. Lastly root-shoot ratios for each species were also determined: 0.454 for Castanopsis cuspidata, 0.356 for Camellia japonica, 0.191 for Quercus acuta and 0.299 for Quercus glauca with the uncertainties lying within a range from 19.8 to 35.7%. These three carbon emission factors including basic wood density had the uncertainties of less than 40% recommended by FAO. Therefore the application of country-specific emission factors seemed to provide quite accurate estimates of carbon emissions and removals. The estimation of the carbon stored in the 4 species were also conducted which amounted to $186.10tCO_2/ha$ for Castanopsis cuspidata, $280.63tCO_2/ha$ for Camellia japonica, $344.04tCO_2/ha$ for Quercus acuta and $278.91tCO_2/ha$ for Quercus glauca and their annual carbon removals were $6.65tCO_2/ha/yr$, $6.25tCO_2/ha/yr$, $11.70tCO_2/ha/yr$ and $12.29tCO_2/ha/yr$, respectively. This systematic assessment of forest resources can be a reliable source of information for managing evergreen broadleaved forest in warm temperate regions and thus serve as useful data for effective decision-making to address vegetation zone shifts due to climate change.

A Study on the Construction Cost Risk through Analyzing the Actual Cost of Public Apartment (공공주택 실적공사비 분석을 통한 공사비 리스크에 관한 연구)

  • Yoon, Woo-Sung;Go, Seong-Seok
    • Korean Journal of Construction Engineering and Management
    • /
    • v.12 no.6
    • /
    • pp.65-78
    • /
    • 2011
  • Construction business, which is complex and long-term business, requires accurate estimation and verification in construction costs and payment procedure from project planning to the completion of construction phase. And more importantly, it is necessary to investigate and determine the risk factors related to construction costs during the entire process including design planning, construction drawings, and quantity calculating. But, currently, it is not seem to be adequate to cope with the risk and increased construction costs against the operational budget in terms of actual costs when screening and estimating the bidding cost of public apartment. Therefore, this study selected and analyzed 40 sites' report of construction completion account from 2004 to 2010 focused on the adequacy on the modification of contract and design planning and on the complication of the budget in the beginning of the project. This study deducted various risk causes and results by analyzing actual costs according to year, architectural area, region, construction cost and sale/lease classification. We could find out construction risk according to annual variation of government policy and economy, and also deducted risk items by construction characteristic according to region and architectural area. Study result, we first found out the problems of lowest price award system according to the construction costs. The weight of the cost increase risk was analyzed that subcontract and material costs are very high. Roof and tile work were analyzed highly in subcontract cost risk and reinforcing bar and cement were analyzed highly in material cost risk, among direct construction cost. Finally, this study results could be used in comparing the categories of the construction costs made by specific construction process, belonging to the construction costs, with the operational budget made in the beginning of the project that can enable to grasp unpredictable risks over the construction costs and making quantitative analysis for it through analyzing the range of fluctuation and variations led by the fluctuations in the actual construction costs.

The Heterogeneity of Flow Distribution and Partition Coefficient in [15O-H2O] Myocardium Positron Emission Tomography ([15O-H2O] 심근 양전자 단층 촬영에서 혈류 분포의 비균일성과 분배계수)

  • Ahn, Ji Young;Lee, Dong Soo;Kim, Kyung Min;Jeong, Jae Min;Chung, June-Key;Shin, Seung-Ae;Lee, Myung Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.32 no.1
    • /
    • pp.32-49
    • /
    • 1998
  • For estimation of regional myocardial blood flow with O-15 water PET, a few modifications considering partial volume effect based on single compartment model have been proposed. In this study, we attempted to quantify the degree of heterogeneity and to show the effect of tissue flow heterogeneity on partition coefficient(${\lambda}$) and to find the relation between perfusable tissue index(PTI) and ${\lambda}$ by computer simulation using two modified models. We simulated tissue curves for the regions with homogeneous and heterogeneous blood flow over a various flow range(0.2-4.0ml/g/min). Simulated heterogeneous tissue composed of 4 subregions of the same or different size of block which have different homogeneous flow and different degree of slope of distribution of blood flow. We measured the index representing heterogeneity of distribution of blood flow for each heterogeneous tissue by the constitution heterogeneity(CH). For model I, we assumed that tissue recovery coefficient ($F_{MME}$) was the product of partial volume effect($F_{MMF}$) and PTI. Using model I, PTI, flow, and $F_{MM}$ were estimated. For model II, we assumed that partition coefficient was another variable which could represent tissue characteristics of heterogeneity of flow distribution. Using model II, PTI, flow and ${\lambda}$ were estimated. For the simulated tissue with homogeneous flow, both models gave exactly the same estimates, of three parameters. For the simulated tissue with heterogeneous flow distribution, in model I, flow and $F_{MM}$ were correctly estimated as CH was increased moderately. In model II, flow and ${\lambda}$ were decreased curvi-linearly as CH was increased. The degree of underestimation of ${\lambda}$ obtained using model II, was correlated with CH. The degree of underestimation of flow was dependent on the degree of underestimation of ${\lambda}$. PTI was somewhat overestimated and did not change according to CH. We conclude that estimated ${\lambda}$ reflect the degree of tissue heterogeneity of flow distribution. We could use the degree of underestimation of ${\lambda}$ to find the characteristic heterogeneity of tissue flow and use ${\lambda}$ to recover the underestimated flow.

  • PDF

Single Laboratory Validation and Uncertainty Estimation of a HPLC Analysis Method for Deoxynivalenol in Noodles (면류에서 HPLC를 이용한 데옥시니발레놀 분석법의 검증과 불확도 산정)

  • Ee, Ok-Hyun;Chang, Hyun-Joo;Kang, Young-Woon;Kim, Mee-Hye;Chun, Hyang-Sook
    • Journal of Food Hygiene and Safety
    • /
    • v.26 no.2
    • /
    • pp.142-149
    • /
    • 2011
  • An isocratic high performance liquid chromatography (HPLC) method for routine analysis of deoxynivalenol in noodles was validated and estimated the measurement uncertainty. Noodles (dried noodle and ramyeon) were analyzed by HPLC-ultraviolet detection using immunoaffinity column for clean-up. The limits of detection (LOD) and quantification (LOQ) were 7.5 ${\mu}g$/kg and 18.8 ${\mu}g$/kg, respectively. The calibration curve showed a good linearity, with correlation coefficients $r^2$ of 0.9999 in the concentration range from 20 to 500 ${\mu}g$/kg. Recoveries and Repeatabilities expressed as coefficients of variation (CV) spiked with 200 and 500 ${\mu}g$/kg were $82{\pm}2.7%$ and $87{\pm}1.3%$% in dried noodle, and $97{\pm}1.6%$ and $91{\pm}12.0%$ in ramyeon, respectively. The uncertainty sources in measurement process were identified as sample weight, final volume, and sample concentration in extraction volume as well as components such as standard stock solution, working standard solution, 5 standard solutions, calibration curve, matrix, and instrument. Deoxynivalenol concentration and expanded uncertainty in two matrixes spiked with 200 ${\mu}g$/kg and 500 ${\mu}g$/kg were estimated to be $163.8{\pm}52.1$ and $435.2{\pm}91.6\;{\mu}g$/kg for dried noodle, and $194.3{\pm}33.0$ and $453.2{\pm}91.1\;{\mu}g$/kg for ramyeon using a coverage factor of two which gives a level of statistical confidence with approximately 95%. The most influential component among uncertainty sources was the recovery of matrix, followed by calibration curve.

Estimation of $T_2{^*}$ Relaxation Times for the Glandular Tissue and Fat of Breast at 3T MRI System (3테슬러 자기공명영상기기에서 유방의 유선조직과 지방조직의 $T_2{^*}$이완시간 측정)

  • Ryu, Jung Kyu;Oh, Jang-Hoon;Kim, Hyug-Gi;Rhee, Sun Jung;Seo, Mirinae;Jahng, Geon-Ho
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.1
    • /
    • pp.1-6
    • /
    • 2014
  • Purpose : $T_2{^*}$ relaxation time which includes susceptibility information represents unique feature of tissue. The objective of this study was to investigate $T_2{^*}$ relaxation times of the normal glandular tissue and fat of breast using a 3T MRI system. Materials and Methods: Seven-echo MR Images were acquired from 52 female subjects (age $49{\pm}12 $years; range, 25 to 75) using a three-dimensional (3D) gradient-echo sequence. Echo times were between 2.28 ms to 25.72 ms in 3.91 ms steps. Voxel-based $T_2{^*}$ relaxation times and $R_2{^*}$ relaxation rate maps were calculated by using the linear curve fitting for each subject. The 3D regions-of-interest (ROI) of the normal glandular tissue and fat were drawn on the longest echo-time image to obtain $T_2{^*}$ and $R_2{^*}$ values. Mean values of those parameters were calculated over all subjects. Results: The 3D ROI sizes were $4818{\pm}4679$ voxels and $1455{\pm}785$ voxels for the normal glandular tissue and fat, respectively. The mean $T_2{^*}$ values were $22.40{\pm}5.61ms$ and $36.36{\pm}8.77ms$ for normal glandular tissue and fat, respectively. The mean $R_2{^*}$ values were $0.0524{\pm}0.0134/ms$ and $0.0297{\pm}0.0069/ms$ for the normal glandular tissue and fat, respectively. Conclusion: $T_2{^*}$ and $R_2{^*}$ values were measured from human breast tissues. $T_2{^*}$ of the normal glandular tissue was shorter than that of fat. Measurement of $T_2{^*}$ relaxation time could be important to understand susceptibility effects in the breast cancer and the normal tissue.

A Quantification Method for the Cold Pool Effect on Nocturnal Temperature in a Closed Catchment (폐쇄집수역의 냉기호 모의를 통한 일 최저기온 분포 추정)

  • Kim, Soo-Ock;Yun, Jin-I.
    • Korean Journal of Agricultural and Forest Meteorology
    • /
    • v.13 no.4
    • /
    • pp.176-184
    • /
    • 2011
  • Cold air on sloping surfaces flows down to the valley bottom in mountainous terrain at calm and clear nights. Based on the assumption that the cold air flow may be the same as the water flow, current models estimate temperature drop by regarding the cold air accumulation at a given location as the water-like free drainage. At a closed catchment whose outlet is blocked by man-made obstacles such as banks and roads, however, the water-like free drainage assumption is no longer valid because the cold air accumulates from the bottom first. We developed an empirical model to estimate quantitatively the effect of cold pool on nocturnal temperature in a closed catchment. In our model, a closed catchment is treated like a "vessel", and a digital elevation model (DEM) was used to calculate the maximum capacity of the cold pool formed in a closed catchment. We introduce a topographical variable named "shape factor", which is the ratio of the cold air accumulation potential across the whole catchment area to the maximum capacity of the cold pool to describe the relative size of temperature drop at a wider range of catchment shapes. The shape factor is then used to simulate the density profile of cold pool formed in a given catchment based on a hypsometric equation. The cold lake module was incorporated with the existing model (i.e., Chung et al., 2006), generating a new model and predicting distribution of minimum temperature over closed catchments. We applied this model to Akyang valley (i.e., a typical closed catchment of 53 $km^2$ area) in the southern skirt of Mt. Jiri National Park where 12 automated weather stations (AWS) are operational. The performance of the model was evaluated based on the feasibility of delineating the temperature pattern accurately at cold pool forming at night. Overall, the model's ability of simulating the spatial pattern of lower temperature were improved especially at the valley bottom, showing a similar pattern of the estimated temperature with that of thermal images obtained across the valley at dawn (0520 to 0600 local standard time) of 17 May 2011. Error in temperature estimation, calculated with the root mean square error using the 10 low-lying AWSs, was substantially decreased from $1.30^{\circ}C$ with the existing model to $0.71^{\circ}C$ with the new model. These results suggest the feasibility of the new method in predicting the site-specific freeze and frost warning at a closed catchment.