• 제목/요약/키워드: Range Safety System

Search Result 801, Processing Time 0.026 seconds

A study on retractile train-gapfiller (도시철도차량의 안전발판에 관한 연구)

  • Choi, Si-Haeng;Yang, Hoe-Sung;Choo, Don-Ho;Cha, Gwan-Bong
    • Proceedings of the KSR Conference
    • /
    • 2009.05a
    • /
    • pp.667-672
    • /
    • 2009
  • In case of high-levelled platform in the urban railway system, a certain width of gap is inevitably formed between the train and the platform, and the gap gets wider when it is concerned with curved portion of the tracks at platform. This gap greatly contributes to decrease of passengers' safety while boarding and alighting a train. In particular, it endangers children's safety. Gap filler system is often fitted out to minimize gap and to overcome this safety problem at platform. However, as existing gap fillers are in most case structurally complex and organized to be powered from separate supply unit, there are a range of non-favorable points from the viewpoint of cost, installation and maintenance. In addition, existing gap fillers are due to cause disruptions in operation of train, with failures such as malfunctioning of control system. In this study, the authors will review on the gap filler applicable to the platforms of various height types, which neither requires any modifications of the train nor causes any operational disruptions. The proposed gap filler system here is a by-stage retractile type and based on the idea of interlocking it with train doors open-close mechanism, without any additional power supply unit or control system.

  • PDF

Experimental approach to evaluate software reliability in hardware-software integrated environment

  • Seo, Jeongil;Kang, Hyun Gook;Lee, Eun-Chan;Lee, Seung Jun
    • Nuclear Engineering and Technology
    • /
    • v.52 no.7
    • /
    • pp.1462-1470
    • /
    • 2020
  • Reliability in safety-critical systems and equipment is of vital importance, so the probabilistic safety assessment (PSA) has been widely used for many years in the nuclear industry to address reliability in a quantitative manner. As many nuclear power plants (NPPs) become digitalized, evaluating the reliability of safety-critical software has become an emerging issue. Due to a lack of available methods, in many conventional PSA models only hardware reliability is addressed with the assumption that software reliability is perfect or very high compared to hardware reliability. This study focused on developing a new method of safety-critical software reliability quantification, derived from hardware-software integrated environment testing. Since the complexity of hardware and software interaction makes the possible number of test cases for exhaustive testing well beyond a practically achievable range, an importance-oriented testing method that assures the most efficient test coverage was developed. Application to the test of an actual NPP reactor protection system demonstrated the applicability of the developed method and provided insight into complex software-based system reliability.

Age-related Deficits in Response Characteristics on Safety Warning of Intelligent Vehicle (지능형 자동차의 안전 경고음에 대한 고령운전자의 반응 특성)

  • Kim, Man-Ho;Lee, Yong-Tae;Son, Joon-Woo;Jang, Chee-Hwan
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.26 no.12
    • /
    • pp.131-137
    • /
    • 2009
  • Recent technological advances made a vehicle more intelligent to increase safety and comfort. An intelligent vehicle provides drivers with safety warning information through audible sounds, visual displays, and tactile devices. However, elderly drivers have been known to decrease the physical and cognitive abilities such as muscular strength, hearing, eyesight, short term memory, and spatial perception. Therefore, possible age-related deficits should be considered to design an effective warning system. This paper aims to evaluate the impact of advancing age on response performance on audible safety warnings which are widely used for alerting driving hazards. In order to understand the effect of age-related hearing loss and movement slowing, three sound characteristics (frequency, intensity, and period) and three age groups (younger, middle, and older) are considered. Data was drawn from 38 drivers who drove a simulated rural road in a driving simulator. Experimental results show that age influences driver's response performance. In conclusion, the appropriate range of a warning sound is suggested.

A Empirical Study on Applying Ubiquitous Technology for Gas Safety Management (U-기반 가스안전관리의 기술을 적용을 위한 실증적 연구)

  • Oh, Jeong-Seok;Choi, Kyung-Suhk;Kwon, Jeong-Rock
    • Journal of the Korean Institute of Gas
    • /
    • v.12 no.2
    • /
    • pp.63-68
    • /
    • 2008
  • The ubiquitous technology is capable of innovating various area to constructing intelligent and network to all objects. This technology can construct network infrastructure to facilities for applying legacy industry and need to develop intelligent service that analyze context-aware through network. This paper derive and propose the introduction range of ubiquitous technology, which should be testified and analyzed network, and studied the detection and analysis of information for managing gas facilities. We investigate the current status of gas facilities and automatic reading system, testing and analyzing wireless personal area network and mobile communication by scalability, self-configuration, connection in underground. Furthermore, we propose modelization method for intelligent service and derive the introduction range for applying ubiquitous technologies for managing gas facilities.

  • PDF

Evaluation of Damage Range Variation Based on Operation System of Chlorine Facility in Water Purification Plant using KORA (KORA를 활용한 정수장 염소 취급시설의 운영조건에 따른 피해범위 변화 평가)

  • Kwak, Sollim;Lim, Hyeongjun;Ryu, Taekwon;Choi, Woosoo;Jung, Jinhee;Lee, Jieun;Kim, Jungkon;Lee, Yeonhee;Ryu, Jisung;Yoon, Junheon;Yoon, Yi;Lee, Jinseon
    • Journal of the Korean Institute of Gas
    • /
    • v.22 no.3
    • /
    • pp.84-90
    • /
    • 2018
  • We researched the way to minimize the damage when the chlorine-leak accident take place in a purification plant. Since the level of risk based on the Off-site Risk Assessment(ORA) is a combination of proportional to the number of residents in the damaged area and frequency of accidents, we suggested the adequate conditions to reduce the number of residents in the damaged area by means of the operating temperature of a handling facility, installation of a emergency shut-off valve, and the analysis of the variation of the damaging range in accordance with the type of enclosure. The coverage of damage was calculated by the 'KORA(Korea Off-site Risk Assessment Supporting Tool) program. The research shows that the lower operating temperature gets, the more emergency shut-off valve being installed and the higher enclosure level of facility becomes, the extent of damage gets decreased. The decreasing rate of worst case was 17.6%, 71%, 34.5% respectively, the decreasing rate of alternative case was 31.6%, 69.0%, 34.8% respectively.

Discussion for Improvement of Decision System of Total Risk in Off-site Risk Assessment (화학사고 장외영향평가 제도의 종합위험도 결정 체계 개선을 위한 고찰)

  • Choi, Woosoo;Ryu, Taekwon;Kwak, Sollim;Lim, Hyeongjun;Jung, Jinhee;Lee, Jieun;Kim, Jungkon;Baek, Jongbae;Yoon, Junheon;Ryu, Jisung
    • Journal of Environmental Health Sciences
    • /
    • v.44 no.3
    • /
    • pp.217-226
    • /
    • 2018
  • Objectives: Despite the positive effects of Off-site risk assessment (ORA) system such as prevention of chemical accidents, some problems have been constantly raised. The purpose of this study is to analyze the problems that have occurred through the implementation of the ORA system for the past three years and to suggest reasonable directions for improvement in the future. Methods: In order to identify the problems with the methodology and procedure of ORA system, we analyzed statutes, administrative rules and documents related to the ORA system. A survey of ORA reviewers in National Institute of Chemical Safety was conducted to investigate the weight of determinants considered when judging the level of total risk in ORA. Results: In this study, we found out the uncertainty of the estimation of the number of people in the impact range in the procedure of the risk assessment of individual handling facilities, the lack of quantitative risk analysis methods for environmental receptors, and the ambiguity of the criteria for the total risk. In addition to suggesting solutions to the problems mentioned above, we also, suggested a decision tree for total risk in ORA. Conclusion: We anticipate that the solutions including the systematic decision tree for total risk suggested will contribute to the smooth operation of the ORA system.

Empirical Study to Strengthen the Disaster Management of Wooden Cultural Heritage - Focused on Concept and Range of Cultural Heritage Disaster Management and Investigation of On-site Manager (목조문화재의 안전관리 강화를 위한 실증적 연구 - 문화재 안전관리의 개념과 범주 및 현장 관리자 의식조사를 중심으로 -)

  • Lim, Suhng-bin;Ryu, Ho-cheol
    • Korean Journal of Heritage: History & Science
    • /
    • v.46 no.2
    • /
    • pp.96-113
    • /
    • 2013
  • The concept of disaster management of cultural heritage is not clearly established and the range and type of it is not organized yet. Also, there is an ever-present danger in the field control because there is no system that can provide safety of cultural heritage from various dangerous factors. Concretely, institutionally, the regulation of disaster management of cultural heritage remains limited and there are not enough reasonableness in installation and management of fire-fighting equipment and safety equipment. Also, we need to take an action to secure the safety of cultural heritage from its surroundings. In this research, we setup the concept, type and criteria for disaster management of cultural heritage to overcome limitations and problems of management of cultural heritage. In addition, in order to raise the level of disaster management of cultural heritage, this research proposes direction to reinforce the disaster management of cultural heritage by investigating and analyzing consciousness of security guards and fire-fighting officers.

A Study on Safety Improvement for Packaged Hydrogen Refueling Station by Risk Assessment (위험성 평가를 통한 패키지형 수소충전소 안전성 향상에 관한 연구)

  • KANG, SEUNGKYU;HUH, YUNSIL;MOON, JONGSAM
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.28 no.6
    • /
    • pp.635-641
    • /
    • 2017
  • In this study, the components of packaged hydrogen filling station were analyzed and risk factors were examined. Risk scenarios were constructed and quantitative risk assessments were conducted through a general risk assessment program (phast/safeti 7.2). Through the risk assessment, the range of damage according to accident scenarios and the ranking that affects the damage according to the risk factors are listed, and scope of damage and countermeasures for risk reduction are provided. The quantitative risk assessment result of the packaged hydrogen filling station through this task will be used as the basic data for improving the safety of the packaged filling system and preparing safety standards.

A REVIEW OF INHERENT SAFETY CHARACTERISTICS OF METAL ALLOY SODIUM-COOLED FAST REACTOR FUEL AGAINST POSTULATED ACCIDENTS

  • SOFU, TANJU
    • Nuclear Engineering and Technology
    • /
    • v.47 no.3
    • /
    • pp.227-239
    • /
    • 2015
  • The thermal, mechanical, and neutronic performance of the metal alloy fast reactor fuel design complements the safety advantages of the liquid metal cooling and the pool-type primary system. Together, these features provide large safety margins in both normal operating modes and for a wide range of postulated accidents. In particular, they maximize the measures of safety associated with inherent reactor response to unprotected, doublefault accidents, and to minimize risk to the public and plant investment. High thermal conductivity and high gap conductance play the most significant role in safety advantages of the metallic fuel, resulting in a flatter radial temperature profile within the pin and much lower normal operation and transient temperatures in comparison to oxide fuel. Despite the big difference in melting point, both oxide and metal fuels have a relatively similar margin to melting during postulated accidents. When the metal fuel cladding fails, it typically occurs below the coolant boiling point and the damaged fuel pins remain coolable. Metal fuel is compatible with sodium coolant, eliminating the potential of energetic fuel-coolant reactions and flow blockages. All these, and the low retained heat leading to a longer grace period for operator action, are significant contributing factors to the inherently benign response of metallic fuel to postulated accidents. This paper summarizes the past analytical and experimental results obtained in past sodium-cooled fast reactor safety programs in the United States, and presents an overview of fuel safety performance as observed in laboratory and in-pile tests.

Direction of research on Railroad Signal Safety Facilities from the viewpoint of Train Control (열차제어 측면의 철도신호안전설비 개발방향 연구)

  • Kim, You-Ho;Lee, Hoon-Koo;Lee, Soo-Hwan;Pyeon, Seon-Ho;Lee, Young-Ho
    • Proceedings of the KSR Conference
    • /
    • 2008.11b
    • /
    • pp.1270-1278
    • /
    • 2008
  • A great deal of development has been made in the field of railroad control in Korea. Like the recent High speed railroad (KTX) and the intercity light rail train (LRT) are being vigorously promoted. Therefore, in concert with the new railroad development projects, improved train control technics are being applied. Along with the focus on these newly developed advanced technologies the need for a reliable safety system for the safety of the passengers and railroad control personnel alike is being intensified. New safety facilities are continuously being developed in order to safely introduce and develop these new technologies. There is an urgent need for research and development of safety facilities for the implementation of the presently developed facilities as well as for the presently being used. Therefore, this research will study the safe operation of Korean railroad and the implementation situation of the class, functionality, ensured safety range etc. of the safety facilities for users and operators. In studying the material of the kinds of implemented safety facilities and technologies being used abroad we have researched into the most suitable direction of development of safety facilities for the Korean railroad environment.

  • PDF