• Title/Summary/Keyword: Range Difference

Search Result 5,032, Processing Time 0.037 seconds

Thermal-mechanical Fatigue Life Prediction of 12Cr Forged Steel Using Strain Range Partitioning method (변형률분할법에 의한 12Cr 단조강의 열피로 수명예측)

  • 하정수;옹장우;고승기
    • Transactions of the Korean Society of Mechanical Engineers
    • /
    • v.18 no.5
    • /
    • pp.1192-1202
    • /
    • 1994
  • Fatigue behavior and life prediction were presented for thermal-mechanical and isothermal low cycle fatigue of 12Cr forged steel used for high temperature applications. In-phase and out-of-phase thermal-mechanical fatigue test at 350 to 600.deg. C and isothermal low cycle fatigue test at 600.deg. C were conducted using smooth cylindrical hollow specimen under strain-control with total strain ranges from 0.006 to 0.015. Cyclic softening behavior was observed regardless of thermal-mechanical and isothermal fatigue tests. The phase difference between temperature and strain in thermal-mechanical fatigue resulted in significantly shorter fatigue life for out-of-phase than for in-phase. The difference in fatigue lives was dependent upon the magnitudes of inelastic strain ranges and mean stresses. Increase in inelastic strain range showed a tendency of intergranular cracking and decrease in fatigue life, especially for out-of-phase thermal-mechanical fatigue. Thermal-mechanical fatigue life prediction was made by partitioning the strain ranges of the hysteresis loops and the results of isothermal low cycle fatigue tests which were performed under the combination of slow and fast strain rates. Predicted fatigue lives for out-of-phase using the strain range partitioning method showed an excellent agreement with the actual out-of-phase thermal-mechanical fatigue lives within a factor of 1.5. Conventional strain range partitioning method exhibited a poor accuracy in the prediction of in-phase thermal-mechanical fatigue lives, which was quite improved conservatively by a proposed strain range partitioning method.

Comparison of between Upper Thoracic Manipulation and Cervical Stability Training on Range of Motion and Neck Disability in Patients with Chronic Mechanical Neck Pain (상부등뼈도수교정과 목뼈부위안정화운동이 만성 목뼈부위 기계학적 통증 환자의 관절가동범위와 장애지수에 미치는 효과 비교)

  • Lee, Byoung-Kwon;Yang, Jin-Mo;Kang, Keung-Hwan
    • Journal of the Korean Society of Physical Medicine
    • /
    • v.10 no.2
    • /
    • pp.35-45
    • /
    • 2015
  • PURPOSE: The aim of this study is to investigate how upper thoracic manipulation and cervical stability training affects cervical range of motion and neck disability index of patients with chronic mechanical neck pain. METHODS: 30 patients with chronic mechanical neck pain, and randomly divided into the upper thoracic manipulation and the cervical stability training group. Upper thoracic manipulation group was conducted to the upper thoracic manipulation, and cervical stability training was conducted to the cervical stability training. Intervention period was 6 weeks, and 3 sessions, each of which was run for 5~10 minutes. The subjects were measured neck range of motion before and after intervention by electro-goniometer. Neck disability index was used to measure neck disability index Korean version. RESULTS: Comparison within groups, there were significant difference in neck range of motion before and after intervention, and Neck disability index significantly reduced in the cervical stability training group. The comparison between groups, there were no significant difference in neck range of motion and neck disability index. CONCLUSION: Upper thoracic manipulation and cervical stability training to the patients with chronic neck pain was helpful to improve neck range of motion and cervical stability training was helpful to improve neck disability index.

Women's Comfort Temperature Range and Dynamic Temperature Change for Maintaining Thermal Comfort in Low Temperature Environment (저온환경에서 여성 온열쾌적성 유지를 위한 쾌적온도범위 및 동적 온도변화 연구)

  • Kim, Soyoung;Lee, Okkyung;Lee, Heeran
    • Fashion & Textile Research Journal
    • /
    • v.22 no.6
    • /
    • pp.853-861
    • /
    • 2020
  • Various types of clothing are being developed to boost thermal comfort during cold winters along with research on change of body temperature when heating is applied. There is a noticeable behavioral difference by gender when using heating panels in a cold environment; however, research on women has been insufficient. This study find a temperature range that provides sustainable thermal comfort in a low temperature environment by observing temperature and change of temperature when subjects are classified according to physical activities or cold sensitivities. For the study results, 8 women in their 20s were subjected to experiment in a low temperature environment for 75 minutes (sitting position: 30 min., running: 15 min., and sitting position: 30 min.). Subjects were asked to turn on/off the heating panel freely to analyze the range of comfortable temperature and clothing microclimate; in addition, skin temperature and heating panel temperature were measured and analyzed at 9 points. As a result, temperature at which subjects turn on and off the heating panel indicated a statistically meaningful difference between the cold sensitivity group depending on exercise or non-exercise. The range of comfortable abdomen temperature was wider than the lower back and was significantly reduced when the subject was running. The range of comfortable temperature was also largest for the heating panel temperature, microclimate, and skin temperature in suggesting that adequate adjustment will be required depending on the surrounding environment or movement of the wearer.

Shoulder and Hip Joint Range of Motion in Normal Adults (정상 성인의 견, 고관절 가동범위에 대한 조사)

  • Ham, Yong-Woon
    • The Journal of Korean Physical Therapy
    • /
    • v.3 no.1
    • /
    • pp.97-108
    • /
    • 1991
  • The purpose of this article is to know the standard figures of joint range of motion, in conjuction with age and sen, for normal adults. The results of assessment and analysis io shoulder and hip joint range of motion are as follows : 1) The average shoulder joint range of motion in normal adults are $160.5^{\circ}$ in flexion, $53.5^{\circ}$ in extension, $159.3^{\circ}$ in adduction, $62.3^{\circ}$ in internal rotation, $83.9^{\circ}$ in external rotation, The average hip joint range of motions are $116.8^{\circ}$ in flexion, $16.1^{\circ}$ in extension, $41.1^{\circ}$ in abduction, $33.8^{\circ}$ in abduction, $40.0^{\circ}$ in interne rotation, $41.2^{\circ}$ in external rotation. 2) There is no significant difference in shoulder and hip joint range of motion between male and female (p>0.05). 3) As to the inter-relation in age and range of motion, the left flexion and extension, internal rotation and right extension in shoulder joint is decreased gradually with increasing age, and left flexion (knee flexion, knee extension) and right flexion (knee extension) in hip joint is decreased with increasing age (p<0.01). 4) Relating to age and sex, the twenties male shows highest range of motion in shoulder and hip joint, with .the fifties female shows, lowest range of motion.

  • PDF

Change of Seawater Intrusion Range by the Difference of Longitudinal Dispersivity in Hydrodynamic Modeling (수리동역학적 모델링에서 분산지수에 따른 해수침투 범위의 변화)

  • 심병완;정상용;김희준;성익환
    • Journal of Soil and Groundwater Environment
    • /
    • v.7 no.4
    • /
    • pp.59-67
    • /
    • 2002
  • As a parameter for hydrodynamic modeling to define the range of seawater intrusion, dispersivities are frequently determined from pre-experiments or theoretical studies because field experiments need a lot of time and expenses. If the dispersivities are inadequate for an aquifer, the numerical results may have some errors. We examined the validity of longitudinal dispersivities by comparing the ranges of seawater intrusion with numerical modeling, field data and apparent resistivity sections. In the numerical modeling the TDS distributions simulated by the Xu's longitudinal dispersivity are more similar to the values of TDS measured at monitoring wet]s and boreholes than those by the Neuman's longitudinal dispersivity. The ranges of seawater intrusion by numerical simulations using Xu's longitudinal dispersivity show that the contour line of 1000 ㎎/L. as TDS is located at 480 m from the coast in May, while at 390 m in July. The difference is originated from the shift of the interface between seawater and fresh water. It moved toward the coast in July because of the seasonal increase of hydraulic gradient according to rainfall. A contour line of 15 ohm-m was used to define the range of seawater intrusion in apparent resistivity sections. From this criterion on the interface between seawater and fresh water, the range of seawater intrusion is located at 450 m from the coast. This result is similar to the range of seawater intrusion simulated by the numerical modeling using Xu's dispersivity. Therefore the range of seawater intrusion shows the difference due to the dispersivities used for the hydrodynamic modeling and the dispersivity generated by the Xu's equation is considered more effective to decide the range of seawater intrusion in this study area.

Study on the Measuring Landscape Sensitivity of Buildings in Natural Landscape (자연경관에 도입되는 건축물의 경관민감도 측정에 관한 연구)

  • Shin, Ji-Hoon;Choi, Won-Bin;Shin, Min-Ji
    • Journal of Korean Society of Rural Planning
    • /
    • v.24 no.2
    • /
    • pp.59-67
    • /
    • 2018
  • As high-rise buildings came in, the landscape of rural areas and natural landscapes often got damaged. Therefore, this study aims to prevent this, grasp the extent of the influence of the surrounding landscape, to grasp the range of height that can be permitted and present the direction of landscape management of agriculture and natural landscape. This study tried to grasp the range of height by using price sensitivity analysis method for two apartment and apartment complex which entered DangJin city and SeoSan city. First, in the case of a two apartment, the range of the height allowable section was from the 6th floor to the 11th floor in close range view, and it was a section from the 7th floor to the 12th floor in medium range view. In the case of the apartment complex, the range of the height allowable range was from the 10th floor to the 17th floor in close range view, the 9th floor to the 16th floor in medium range view. The stress index was found to be positive in a two apartment in close range view, and in the apartment complex case. therefore it was better to set it to a lower in the Range of Acceptable Height(RAH). Second, it showed no difference in the sensitivity of landscape to gender. Thirdly, the results of the landscape sensitivity analysis of major and non-major showed the difference in the medium range view picture of the apartment complex. Majors are lower than the point of minimum height(PMinH) than non-Majors. In the case of major, the stress index was 1.4. it turned out that it was better to make a decision closer to point of minimum height (PMinH). In the case of non-major, the stress index was -1.3. it was also able to accept decision close to the point of maximum height (PMaxH). Since the results of the above research gave changes only in the variable of the height of the landscape, we can not grasp the point of interaction with other variables, and future research is considered necessary.

Measurement of electron density of atmospheric pressure Ar plasma jet by using Michelson interferometer

  • Lim, Jun-Sup;Hong, Young June;Choi, Eun Ha
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2016.02a
    • /
    • pp.195.1-195.1
    • /
    • 2016
  • Currently, as Plasma application is expanded to the industrial and medical industrial, low temperature plasma applications became important. Especially in medical and biology, many researchers have studied about generated radical species in atmospheric pressure low temperature plasma directly adapted to human body. Therefore, so measurement their plasma parameter is very important work and is widely studied all around world. One of the plasma parameters is electron density and it is closely relative to radical production through the plasma source. some kinds of method to measuring the electron density are Thomson scattering spectroscopy and Millimeter-wave transmission measurement. But most methods have very expensive cost and complex configuration to composed of experiment system. We selected Michelson interferometer system which is very cheap and simple to setting up, so we tried to measuring electron density by laser interferometer with laser beam chopping module for measurement of temporal phase difference in plasma jet. To measuring electron density at atmospheric pressure Ar plasma jet, we obtained the temporal phase shift signal of interferometer. Phase difference of interferometer can occur because of change by refractive index of electron density in plasma jet. The electron density was able to estimate with this phase difference values by using physical formula about refractive index change of external electromagnetic wave in plasma. Our guiding laser used Helium-Neon laser of the centered wavelength of 632 nm. We installed chopper module which can make a 4kHz pulse laser signal at the laser front side. In this experiment, we obtained more exact synchronized phase difference between with and without plasma jet than reported data at last year. Especially, we found the phase difference between time range of discharge current. Electron density is changed from Townsend discharge's electron bombardment, so we observed the phase difference phenomenon and calculated the temporal electron density by using phase shift. In our result, we suggest that the electron density have approximately range between 1014~ 1015 cm-3 in atmospheric pressure Ar plasma jet.

  • PDF

Effects of UV Absorber and HALS(Hindered Amine Light Stabilizer) Addition in Water-soluble Acrylic Resin on Discoloration of Larix leptolepis (S. et Z.) Gordon (수용성(水溶性) 아크릴 수지(樹脂)의 자외선(紫外線) 흡수제(吸收劑)와 HALS 첨가(添加)가 일본잎갈나무의 변색(變色)에 미치는 영향(影響))

  • Kang, Kyoung-Taek;Lee, Phil-Woo
    • Journal of the Korean Wood Science and Technology
    • /
    • v.24 no.4
    • /
    • pp.47-55
    • /
    • 1996
  • UV transmission spectra of water-soluble acrylic resin films containing hydroxybenzophenolic, hydroxyphenylbenzotriazolic UV absorber and HALS(hindered amine light stabilizer) were investigated by exposure time(before exposure weathered for 160 and 320hours) in QUV Weather-Ometer. Also the YID(yellowness index difference), LID(lightness index difference) and CD(color difference) of dried water-soluble acrylic resin films and the coated woods of Larix leptolepis were analyzed by addition level of UV absorber(0, 1, 2 and 3%) and HALS(0, 0.5, 1 and 1.5%) and by exposure time in QUV Weather-Ometer. They showed no significant effects on UV transmission spectra of dried water-soluble acrylic resin films in the range of 300 to 400nm irrespective of exposure time. However, UV transmission decreased as increase of exposure time. UV transmission spectra were lower in dried water-soluble acrylic resin films containing hydroxybenzophenolic UV absorber and HALS than in these containing hydroxyphenylbenzotriazolic UV absorber and HALS in the range of 350 to 400nm. The least YID, LID and CD in the coated woods of Larix leptolepis appeared at the addition level of 3%, based on non-volatile content, in hydroxybenzophenolic and hydroxyphenylbenzotriazolic UV absorber, and of 1.5% in HALS to water-soluble acrylic resin.

  • PDF

The View Character of Mountainscape of a City according to Visual Point Level - In a Case of Mt. Uam - (시가지내 산악경관의 시점 높이별 조망 특성 - 청주시 우암산을 대상으로 -)

  • Jeong, Jeong Seop;Gwon, Sang Jun;Jo, Tae Dong
    • Journal of Environmental Science International
    • /
    • v.13 no.6
    • /
    • pp.497-503
    • /
    • 2004
  • In this research, we have performed a T-test to see how the relationship between dependent variable or visual point level and independent variable or visual quantity is in order to clear up the correlation between pattern of visual point and visual quantity by the constituents of a view from a different visual point level and the results are as follows: 1) In case of the character of Mt. Uam landscape of the city, Uamsan is set as a fixed point and about a direction of view(D), the north is a datum point from which the range of direction is distributed within 1800 westwardly and the visual range(R) is also within 2000m. An elevation is an average of 7.40 and the average story of the buildings is 3.85. Here the height of a story is about 4m so the average of the visual point difference is estimated at 15.4m. 2) The type of visual point is divided into the intersection group and the front of the highly used public buildings group. Double intersection types account for about 78.80%(52 spots) which forms a majority part of LCP. 3) The analysis of the difference of visual point level divided by eye level and that of the top of the buildings has been proved that there's a sharp difference resulted from t-test at 1 % significant level. The significant difference of elevation from height difference(l5.93m), however, has not been shown. 4) From the result of T-test about visual quantity by the elements of a view from a different visual point level, the visual quantity of mountain(VQM), sky(VQS), ground(VQG) is significant at about 1% each and that of building(VQB) is at about 5%. The difference in visual quantity of a mountain by the visual point level is at about 4% which can meet a marginal level of LCP necessary for evaluation of mountainscape.

Study on Field Observations of the Thermal Environment in the Downtown Location and the Outskirt Site (하절기 도심과 외곽지의 열특성 비교 관측)

  • Jung, Im-Soo;Choi, Dong-Ho;Lee, Bu-Yong
    • 한국태양에너지학회:학술대회논문집
    • /
    • 2009.11a
    • /
    • pp.21-25
    • /
    • 2009
  • This study is about heat island as one of the urban climate variation factors in urbanized modern society, which compared and observed the thermal characteristics both the downtown location and the outskirt site in summer. The diurnal air temperature range at each point is $12.6^{\circ}C$ in the downtown location and $14.3^{\circ}C$ in the outskirt site, so, it was found that the diurnal air temperature range in the outskirt site was $1.7^{\circ}C$ higher than in the downtown location. There was 20 minutes difference to reach the highest temperature between globe temperature and air temperature in the downtown location, however, the time spent to reach the highest temperature between globe temperature and air temperature in the outskirt site was the same. When we compared the globe temperature between the downtown location and outskirt site, we found that the temperature in the outskirt site was lower than in the downtown location after sunset due to the sudden temperature drops, although the exposed time to insolation in the outskirt site is longer. The average of globe temperature difference on the sample days was $1.1^{\circ}C$, the average of surface temperature difference on the sample days was $1.0^{\circ}C$, and the average of air temperature difference on the sample days was $2.0^{\circ}C$ Thus, it was found that the average of air temperature difference was higher than the average of globe temperature and the average of surface temperature. The result of this study is that the urban environment factors have more effect on the air temperature difference than globe temperature and surface temperature.

  • PDF