• Title/Summary/Keyword: Rainwater retention

Search Result 26, Processing Time 0.022 seconds

Estimation of Proportion to Decentralized Rainwater Management Needed in Apartment Complex Development (공동주택단지 개발에서의 분산식 빗물관리 목표량 설정 - 택지개발사업지구 내 단지를 대상으로 -)

  • Lee, Tae-Goo;Han, Young-Hae
    • KIEAE Journal
    • /
    • v.6 no.3
    • /
    • pp.27-34
    • /
    • 2006
  • The recent emphasis on ecological urban development has led to the need to maintain a hydrologic cycle in urban areas. As such, this study proposes decentralized rainwater management, a concept of onsite rainwater management that involves the utilization, infiltration, detention, and retention of rainwater. The main objective of this research is to estimate the proportion of decentralized rainwater management that is needed. From the research that was conducted in this study, it was found that the total runoff quantity increases by 10-20% after district lands are developed, when the probable rate of precipitation every 10 years is within this range. Thus, the runoff rate can be reduced by 10~20% of the total runoff quantity through decentralization. On the other hand, in the scale of housing complex development, the total runoff quantity increases by as much as 10~40% due to the changes in the rate of the impervious surface area. If 10-40% of the total runoff quantity was processed through decentralized rainwater management, the rate of infiltration, detention, retention, and runoff in precipitation prior to development could be recovered.

Development of Inundation Flooding Simulation Program for Selecting Optimum Installation Site for Rainwater Infiltration Detention Block (빗물침투저류블록의 설치 최적지 선정을 위한 침수범람 시뮬레이션 프로그램의 개발)

  • Kim, Seongpyo;Lee, Taegyo;Ryu, Jungrim;Park seonmee;Choi, Heeyong;Choi, Hyeonggil
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2023.11a
    • /
    • pp.129-130
    • /
    • 2023
  • This study proposes rainwater infiltration retention blocks as a solution to the flooding problems caused by recent climate change and developed a flood prediction simulation program to select the optimal site for installing rainwater infiltration retention blocks that can minimize damage from floods. By applying the existing 2D flood analysis model G2D and adding a reservoir function, the volume of water before and after installation can be determined through simulation results.

  • PDF

Particle Removal in a Rainwater Storage Tank, and Suggestions for Operation & Design (빗물저장조에서 입자의 제거특성 및 운전과 설계시 고려사항)

  • Mun, Jungsoo;Yoo, Hyoungkeun;Han, Mooyoung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.1
    • /
    • pp.131-138
    • /
    • 2007
  • A rainwater utilization facility consists of its catchment area, treatment facility, storage tank, supply facility and pipes in general. The rainwater storage tank which occupies the largest area of the facility has been usually considered quantitatively for determining the storage capacity. Hence, there is little information on water quality improvement by sedimentation in a rainwater storage tank in operation. In this study, we measured the rainwater quality in a rainwater storage tank in operation during late spring and summer, and showed water quality improvement of turbidity removal of 25~46% by sedimentation in a rainwater storage tank under a fixed water level without inflow and outflow after runoff ceased. It is necessary to have a considerable distance between the inlet and outlet of the tank and, if possible, it is recommended that the design should allow for an effective water depth of over 3 m and supply rainwater near the water surface. The operation method which increases the retention time by stopping rainwater supply for insuring low turbidity is recommended when the turbidity of rainwater runoff is high. And also more efficient operation and maintenance of the rainwater utilization facility is expected through the tailored design and operation of the facility considering particle removal and behavior.

A Study on Decentralized Rainwater Management by Analysing the Spacial Properties in Urban Housing Complexes (공동주택단지의 공간적 특성 분석을 통한 분산식 빗물관리 방향 설정)

  • Han, Young-Hae;Yang, Byoung-E;Lee, Tae-Goo
    • KIEAE Journal
    • /
    • v.5 no.3
    • /
    • pp.17-24
    • /
    • 2005
  • Until today, rainwater management was processed without disposing the peak discharge, which was due to rainfall, to provide stability against flood damage. In this process, the natural hydrologic cycle changed quickly, and because of this, some problems that could harm human beings and the environment arose. These problems need to be addressed accordingly. One of the proposals was to carry out decentralized rainwater management through a natural hydrologic cycle on site, including utilization, infiltration, detention, and retention of rainwater. This study aims to set the direction of applicable decentralized rainwater management to housing complex in Korea. Therefore, spacial properties in urban housing complexes were analysed such as the impervious area-to-land ratio, the green area-to-land ratio, artificial land-to-land ratio etc. As the result of this study, when a housing complex was small and developed by reconstruction, the impervious area, artificial land, the green area in the artificial land-to-land ratio were high. So, direction of decentralized rainwater management of these housing complexes is available to utilize and detain rainwater. On the other hand, those of big housing complexes in land development district were low relatively. So, direction of decentralized rainwater management of these housing complexes is available to infiltrate and evaporate rainwater.

A Determination Method of a Rainwater Retention-Pumping System Combination for Runoff Control from Building Roof Area (지붕면 유출제어를 위한 빗물의 저장-펌프 시스템 조합 결정방안)

  • Kim, Young-Jin;Han, Moo-Young
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2008.05a
    • /
    • pp.495-499
    • /
    • 2008
  • This study developed a determination method for a rainwater retention-pumping combination system for roof runoff control. The outflow and stored water volume in the rainwater system was simulated using a water balance equation. Its result is presented in the TPP (Tank capcity-Peak outflow-Pumping rate) curves for rainfall return periods. In a case study on reduction of the peak flow rate of 100-year return period to 5-year in Seoul, The range of pumping rate for $100m^2$ roof area is determined as $0{\sim}25{\ell}$/min. Additionally, retention volume of $8.5{\sim}10m^3$ can be combined with the pumping rate range. That is to say an effective combination of a retention-pumping system capacity can be determined from a system of $8.5m^3$ tank with $25{\ell}$/min to $10m^3$ tank without pump. Using the TPP curves, engineers can determine the effective combination range of retention & pumping system capacity. Furthermore, that can be helpful to decide a detail system capacity for field condition.

  • PDF

Evaluation of Rainwater Utilization for Miscellaneous Water Demands in Different Types of Buildings Using Geographic Information System

  • Kim, Jinyoung;An, Kyoungjin;Furumai, Hiroaki
    • Environmental Engineering Research
    • /
    • v.18 no.2
    • /
    • pp.85-90
    • /
    • 2013
  • This study is an attempt to quantify rainwater utilization and miscellaneous water demand in Tokyo's 23 special wards, the core of the urban area in Tokyo, Japan, in order to elucidate the potential of further rainwater utilization. The rainwater utilization for miscellaneous appropriate water demands, including toilet flushing, air conditioning, and garden irrigation, were calculated for six different types of building: residential house, office, department store, supermarket, restaurant, and accommodation. Miscellaneous water demands in these different types of building were expressed in terms of equivalent rainfall of 767, 1,133, 3,318, 1,887, 16,574, and 2,227 (mm/yr), respectively, compared with 1,528 mm of Tokyo's average annual precipitation. Building types, numbers and its height were considered in this study area using geographic information system data to quantify miscellaneous water demands and the amount of rainwater utilization in each ward. Area precipitation-demand ratio was used to measure rainwater utilization potential for miscellaneous water demands. Office and commercial areas, such as Chiyoda ward, showed rainwater utilization potentials of <0.3, which was relatively low compared to those wards where many residential houses are located. This is attributed to the relatively high miscellaneous water demand. In light of rainwater utilization based on building level, the introduction of rainwater storage mechanisms with a storage depth of 50 mm for six different types of buildings was considered, and calculated as rainfall of 573, 679, 819, 766, 930, and 787 (mm), respectively. Total rainwater utilization using such storage facilities in each building from 23 wards resulted in the retention of 102,760,000 $m^3$ of water for use in miscellaneous applications annually, and this volume corresponded to 26.3% of annual miscellaneous water demand.

Application of Percentile Rainfall Event for Analysis of Infiltration Facilities used by Prior Consultation for LID (Low Impact Development)

  • Kwon, Kyung-Ho;Song, Hye-Jin
    • KIEAE Journal
    • /
    • v.15 no.5
    • /
    • pp.5-12
    • /
    • 2015
  • Purpose: Retention and infiltration of small and frequently-occurring rainfall by LID facilities account for a large proportion of the annual precipitation volume. Based on 4 standard facilities such as Porous Pavement, Infiltration Trench, Cylindrical Infiltration Well, Rectangular Infiltration Well by Seoul Metropolitan Handbook of the Prior Consultation for LID. The total retention volume of each facility was calculated according to the type and size. The Purpose of this study is to find out the quantitative relationship between Percentile Rainfall Event and Design Volume of Infiltration Facilities. Methode: For the estimation of Percentile Rainfall Event, Daily Precipitation of Seoul from 2005 to 2014 was sorted ascending and the distribution of percentile was estimated by PERCENTILE spreadsheet function. The managed Rainfall Depth and Percentile of each facility was calculated at the several sizes. In response to the rainwater charge volume of 5.5mm/hr by the Category "Private large site", the 3 types of facilities were planned for example. The calculated Rainfall Depth and Percentile were 54.4mm and 90% by the use of developed Calculation-Module based on the Spreadsheet program. Result: With this Module the existing Designed Infiltration volume which was introduced from Japan was simply converted to the Percentile-Rainfall-Event used in USA.

Stability analyses of dual porosity soil slope

  • Satyanaga, Alfrendo;Moon, Sung-Woo;Kim, Jong R.
    • Geomechanics and Engineering
    • /
    • v.28 no.1
    • /
    • pp.77-87
    • /
    • 2022
  • Many geotechnical analyses require the investigation of water flow within partially saturated soil zone to incorporate the effect of climatic conditions. It is widely understood that the hydraulic properties of the partially saturated soil should be included in the transient seepage analyses. However, the characteristics of dual porosity soils with dual-mode water retention curve are normally modelled using single-mode mathematical equation for simplification of the analysis. In reality, the rainwater flow can be affected significantly by the dual-mode hydraulic properties of the soil. This paper presents the variations of safety factor for dual porosity soil slope with dual-mode water retention curve and dual-mode unsaturated permeability. This paper includes the development of the new dual-mode unsaturated permeability to represent the characteristics of soil with the dual-mode water retention curve. The finite element analyses were conducted to examine the role of dual-mode water retention curve and dual-mode unsaturated permeability on the variations of safety factor under rainfall loading. The results indicate that the safety factor variations of dual porosity soil slope modelled using the dual-mode water retention curve and the unsaturated permeability equation are lower than those of dual porosity slope modelled using single-mode water retention curve and unsaturated permeability equations.

The Characteristics of Water Usage in Jeju Golf Courses (제주지역 골프장의 용수 이용특성)

  • Park, Won-Bea;Kim, Bong-Seok;Yang, Sung-Kee;Moon, Duk-Chul
    • Journal of Environmental Science International
    • /
    • v.20 no.10
    • /
    • pp.1297-1308
    • /
    • 2011
  • This study is to analyze the characteristics of golf course water usage using groundwater and rainwater data obtained from 17 golf courses in Jeju Island during 2007~2009. The groundwater usages were 246,275 $m^3/year$, 213,062 $m^3/year$, 155,235 $m^3/year$, and 126,666 $m^3/year$ in the west, south, east, and north regions, respectively. Monthly rate of the amount of groundwater usage to the amount of permission was 29.5%. The rainfall usages were 386,591 $m^3/year$, 326,464 $m^3/year$, 251,248 $m^3/year$, and 232,061 $m^3/year$ in the south, west, east, and north regions, respectively. Monthly rate of rainwater usage to the amount of water retention of golf courses was 19.6%. The average annual water usage in the 17 golf courses was 499,377 $m^3/year$. From the average usage, it was found that the rainwater usage (305,126 $m^3/year$ ) was 1.6 times higher than that of groundwater (194,251 $m^3/year$ ). That means the annual average rainwater usage to the entire water usage was 61.1%, which was above the criteria of 40%.

An Experimental Runoff Formula in Building Roof Area for On-site Rainwater Management (On-site 방식 빗물관리를 위한 건축물 지붕면의 유출특성 경험식 수립)

  • Kim, Young-Jin;Han, Moo-Young;Kim, Yong-Ha;Mun, Jung-Soo
    • Journal of Korea Water Resources Association
    • /
    • v.42 no.2
    • /
    • pp.171-176
    • /
    • 2009
  • This study proposes an experimental formula for cumulative runoff analysis in building roof for on-site rainwater management. We can not find an appropriate method for roof runoff analysis because of its small area scale. A new runoff equation formula for rainfall depth(D) and cumulative runoff volume(V) is developed on roof runoff conditions. Reliability of the formula is verified with field experimental runoff monitoring for two years in two buildings of rainwater management system. This experimental runoff formula can root the cumulative runoff volume from roof area and rainfall depth, then develop reasonable inflow condition for rainwater retention tank design.