• 제목/요약/키워드: Rainfall Rate

검색결과 771건 처리시간 0.029초

강우의 개념적 시간분포와 설계홍수량 산정에 관한 연구 (The Estimations of A Conceptual Time Distribution of Rainfall and Design Flood)

  • 이병운;장대원;김형수;서병하
    • 한국수자원학회:학술대회논문집
    • /
    • 한국수자원학회 2005년도 학술발표회 논문집
    • /
    • pp.937-942
    • /
    • 2005
  • It is necessary to estimate the runoff hydrograph and peak flood discharge using law of probability for synthetic flood control policy and design of hydraulic structures. Rainfall analysis is needed in the process of peak flood discharge estimation and the time distribution of a design rainfall is a very important process in the analysis. In this study, we estimate design flood for a small urban basin and a rural basin of medium scale which have different travel times. The Huff method is widely used in Korea for the time distribution of design rainfall to estimate design flood. So, we use Huff method and a conceptual method which is suggested in this study for the comparative purpose. The 100-year frequency rainfall is used to estimate design flood for each basin and the design flood is compared with the existing design flood. As the result, the design flood is overestimated $14.6m^3/sec$ by Huff method and is underestimated $70.9m^3/sec$ by a conceptual method for the rural basin. For the small urban basin, the design flood is excessively overestimated $294.65m^3/sec$ by Huff method and is overestimated $173m^3/sec$ by a conceptual method. The reason of excessive overestimation by Huff method in the small urban basin is that the increased rate of rainfall intensity according to the decrease of duration is large and the duration exceeds the time of concentration when the increased rainfall intensity is concentrated in a quartile. Therefore, we suggested a conceptual method for the time distribution of design rainfall by considering the rainless period and duration. Especially, the conceptual method might be useful for the small urban basin with short concentration time which the design flood is overestimated by Huff method.

  • PDF

강우유발 면상흐름에 의한 세류간 침식에 대한 유효동력 (Effective power for interrill erosion by rainfall-induced sheet flow)

  • 신승숙;박상덕
    • 한국수자원학회논문집
    • /
    • 제51권8호
    • /
    • pp.665-676
    • /
    • 2018
  • 사면에서의 세류간 토양침식은 빗물방울의 지표면 타격에 의한 토양입자의 박리와 면상흐름에 의한 토사이송의 상호작용에 의한 결과이다. 본 연구는 토양입자를 박리하는 강우동력과 유사이송에 기여하는 면상흐름동력을 토양침식을 위한 에너지 소비율 측면에서 새롭게 정의하고, 강우유발 면상흐름에 의한 세류간 토양침식의 유효동력 함수를 제시하였다. 강우, 경사, 유출과 관계된 인자들에 따른 강우 면상흐름의 동력을 평가하고, 기존 연구 자료를 바탕으로 이 함수의 상수들을 분석하였다. 또한 강우와 면상흐름 동력의 상대적인 크기 변화는 세류간 토양침식의 물리적 과정과 수문학적 반응을 반영함을 확인하였다. 지표유출 및 토양침식 실측자료를 세류간침식 평가 모형들에 적용한 결과 강우 면상흐름동력 함수가 가장 높은 정확도를 보여 세류간 토양침식 평가에 적합하다는 것을 확인하였다.

연최대치 계열과 연최대치 독립 호우사상 계열의 비교 (Comparison of Annual Maximum Rainfall Series and Annual Maximum Independent Rainfall Event Series)

  • 유철상;박철순
    • 한국수자원학회논문집
    • /
    • 제45권5호
    • /
    • pp.431-444
    • /
    • 2012
  • 본 연구에서는 강우 지속기간이 짧은 경우와 긴 경우에 대한 연최대치 계열과 연최대치 독립 호우사상 계열의 차이를 살펴보았다. 연최대치 독립호우사상은 1961년부터 2010년까지의 서울지점 시강우 자료에 다양한 IETD와 절단값을 적용하여 추출하였다. 결정된 연최대치 독립호우사상 계열은 기존의 연최대치 계열과 비교하였다. 그 결과를 요약하면 다음과 같다. 첫째, IETD와 절단값의 영향은 예상할 수 있는 수준을 벗어나지 않았다. 예를 들어, IETD의 증가에 따라 짧은 지속기간 및 긴 지속기간을 갖는 독립 호우사상의 발생 빈도는 유사한 감소비율을 갖으나, 절단값의 증가에 따라서는 특히 지속기간이 긴 호우사상의 발생빈도가 급격히 감소하는 것으로 나타났다. 둘째, 추출된 독립 호우사상의 평균 강우강도는 강우 지속기간에 관계없이 거의 일정한 것으로 나타났다. 이는 연 최대치 강우강도가 주로 지속기간이 긴 호우사상에서 결정될 가능성이 크다는 것을 의미한다. 마지막으로, 강우지속기간이 짧은 경우, 연 최대치 계열과 연 최대치 독립 호우사상 계열의 차이가 매우 큰 것으로 확인되었다. 그러나 이러한 차이는 강우 지속기간이 증가함에 따라 현저히 줄어들었다. 이러한 결과는 특히 매우 짧은 집중시간을 고려하는 작은 유역의 경우, 전통적인 자료 분석방법을 통해 결정된 설계강우가 실제 발생 가능성이 없는 비현실적인 경우가 될 가능성이 매우 큼을 의미한다.

생태저류지 LID 시설의 강우유출수 처리비 산정 (Estimation of Stormwater Interception Rate for Bio-retention LID Facility)

  • 최정현;이옥정;김상단
    • 한국물환경학회지
    • /
    • 제33권5호
    • /
    • pp.563-571
    • /
    • 2017
  • Because of the rapid progress of urbanization in recent decades, the proportion of impervious areas in cities has increased. As a result, hydrological properties of urban streams have changed and non-point pollution sources have increased, that have had considerable influence on human life and ecosystems. To manage these situations, application of non-point pollution reduction facilities and LID facilities are expanding recently. In this study, it is investigated if rainfall interception rate used in design of non-point pollution reduction facilities can be applied to design of LID facilities. For this purpose, EPA SWMM is constructed for part of Noksan National Industrial Complex area wherein long-term observed storm water data can be obtained and storm water interception rates for various design capacities of a bio-retention LID facility reservoirs are estimated. While sensitivity of storm water interception rate according to design specifications of bio-retention facility is not large, sensitivity of storm water interception rate according to regional rainfall characteristics is relatively large. As a result of comparing present rainfall interception rate estimation method with the one proposed in this study, the present method is highly likely to overestimate performance of the bio-retention facility. Finally, a new storm water interception rate formula for bio-retention LID facility is proposed.

Retrieval of Rain-Rate Using the Advanced Microwave Sounding Unit(AMSU)

  • Byon, Jae-Young;Ahn, Myoung-Hwan;Sohn, Eun-Ha;Nam, Jae-Cheol
    • 대한원격탐사학회:학술대회논문집
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.361-365
    • /
    • 2002
  • Rain-rate retrieval using the NOAA/AMSU (Advanced Microwave Sounding Unit) (Zaho et al., 2001) has been implemented at METRI/KMA since 2001. Here, we present the results of the AMSU derived rain-rate and validation result, especially for the rainfall associated with the tropical cyclone for 2001. For the validation, we use rain-rate derived from the ground based radar and/or rainfall observation from the rain gauge in Korea. We estimate the bias score, threat score, bias, RMSE and correlation coefficient for total of 16 tropical cyclone cases. Bias score shows around 1.3 and it increases with the increasing threshold value of rain-rate, while the threat score extends from 0.4 to 0.6 with the increasing threshold value of precipitation. The averaged rain-rate for at all 16 cases is 3.96mm/hr and 1.41mm/hr for the retrieved from AMSU and the ground observation, respectively. On the other hand, AMSU rain-rate shows a much better agreement with the ground based observation over inner part of tropical cyclone than over the outer part (Correlation coefficient for convective region is about 0.7, while it is only about 0.3 over the stratiform region). The larger discrepancy of tile correlation coefficient with the different part of the tropical cyclone is partly due to the time difference in between ice water path and surface rainfall. This results indicates that it might be better to develop the algorithm for different rain classes such as convective and stratiform.

  • PDF

Ku대역 무인항공기 데이터 링크 설계를 위한 강우감쇠 분석 (Rain Attenuation Analysis for Designing UAV Data Link on Ku-Band)

  • 이재윤
    • 한국통신학회논문지
    • /
    • 제40권7호
    • /
    • pp.1248-1256
    • /
    • 2015
  • 강우에 취약한 특성을 갖는 Ku대역을 이용한 통신 링크 설계 시에는 반드시 정확한 데이터와 정밀한 예측모델을 이용하여 도출한 강우감쇠 값을 반영하여 링크 마진을 분석하여야 한다. 따라서 본 논문에서는 최근 TTA에서 제시한 국내 강우강도 분포를 분석하여 Rec. ITU-R PN.837-1 및 Crane 모델에서의 지역별 강우강도와 비교하고, 우리나라의 최근 강우강도 분포와 유사한 지역을 선택하여 Ku대역 주파수에 대한 해당 지역의 강우감쇠를 Rec. ITU-R P.618-8와 Crane 강우감쇠 예측 모델을 통해 무인항공기와 지상통신장비의 통신 링크 거리 및 연 시간율 (%)에 따라 분석한다.

Crane 예측 모델을 활용하여 국내 지역별 강우강도 분포에 따른 Ka대역 강우감쇠 분석 (Ka Band Rain Attenuation Analysis of Domestic Regional Rainfall-Rate Distribution by Crane Prediction Model)

  • 조용완
    • 한국위성정보통신학회논문지
    • /
    • 제11권3호
    • /
    • pp.110-113
    • /
    • 2016
  • 정지궤도 위성을 이용한 Ka대역 위성통신은 강우에 가장 취약하다. 이렇게 강우감쇠에 취약한 위성통신 링크 설계 시 좀 더 확실한 지역 강우분포와 정확한 강우감쇠 예측모델을 이용하여 계산된 강우 감쇠값을 반영하여 위성통신망의 링크버짓을 분석하여야 한다. 따라서 본 논문에서는 최근 TTA에서 분석한 국내 지역별 강우강도 분포를 활용하여 Crane 강우감쇠 예측의 지역별 강우강도와 국내 지역별 강우강도 분포를 활용하여 해당 지역의 강우감쇠를 Ka대역 주파수 특성에 맞는 Crane 강우감쇠 예측 모델을 통해 정지궤도 위성과 지상 송수신국간의 위치, 거리 및 연 시간율(%) 요인을 반영하여 분석하였다.

수질오염총량관리를 위한 비점배출계수 산정 - 특정 기준유량 시기의 강우배출비 (Estimation of Nonpoint Discharge Coefficient for the Management of Total Maximum Daily Load - Rainfall Discharge Ratio on the Specific Design Flow)

  • 박준대;박주현;류덕희;정동일
    • 한국물환경학회지
    • /
    • 제24권4호
    • /
    • pp.452-457
    • /
    • 2008
  • Nonpoint source (NPS) pollution is caused by rainfall moving over and through the ground. As the runoff moves, it picks up and carries away various pollutants from NPS. The discharge pattern of NPS pollutant loads is affected by the distribution of the rainfall during the year. This study analysed relationship between the rainfall event and the stream flow rate, and estimated the rainfall discharge ratio on the specific design flow which can be used as nonpoint discharge coefficient for the estimation of NPS pollution load. It is considered that nonpoint discharge coefficient can be effectively used for the calculation of NPS pollution load at the time of water quality modelling for the management of Total maximum daily load (TMDL).

강우량과 강우강도에 따른 지반함몰 상관관계 분석 (Ground Subsidence Risk Analysis on Correlation between Rainfall and Rainfall intensity)

  • 최창호;김진영;강재모;이성열;백원진
    • 한국농공학회논문집
    • /
    • 제64권3호
    • /
    • pp.75-83
    • /
    • 2022
  • Recent settlements and sinkhole openings in urban areas have caused social problems such as damage to roads and structures, fear of the public, and loss of property. Several studies have demonstrated that surface subsidence and sinkhole opening are greatly affected by rainfall and rainfall intensity in urban areas. In this paper, we analyzed the relationship with the characteristics of recorded rainfall data using the ground subsidence database reported in major cities. The correlations were found using sedimentation and precipitation data from 2010 to 2014. The duration and intensity of a given precipitation have evolved to obtain an effect on ground sedimentation rate (SR). The results show that the relationship between SR and precipitation is asymptotic and can be modeled by a hyperbolic equation. Through this study, it is possible to predict the occurrence of ground subsidence due to precipitation in advance.

제초제 처리 과수원 포장에서 강우 사상의 효과. 2. 유거와 토양침식의 변화 (Effects of Rainfall Events on Soil in Orchard Field under Herbicide Treatment. 2. Characteristics of Runoff and Soil Erosion)

  • 정덕영;박미숙;이규승;이진호
    • 한국토양비료학회지
    • /
    • 제43권1호
    • /
    • pp.36-43
    • /
    • 2010
  • 충남 공주 팔봉산 남쪽 측면에 위치한 3년간 배나무가 식재된 구릉성 침식포장에서 유거와 침식의 변화를 (1)Glyphosate 처리 (2) paraquat 처리의 두 가지 서로 다른 제초관리 형태하에서 조사하였다. 조사지의 경사도는 5.5% ~ 10.2%, 고도 125 m이며 조사면적은 896 $m^2$ ($28m{\times}32m$)였다. 2006년에서 2008년 사이 총강우사상은 각각 47, 52, 52회였다. 전체 강우사상 중 일 강우량이 20 mm보다 적은 날은 전체 강우일수의 약 65%를 차지하였다. 평형상태에서 침투율은 지표면의 잡초가 모두 제거된 나지에서 일반적으로 증가하였으며, 제초제처리구와 대조구에서는 감소하였다. 모든 대조구에서 유거는 제초제처리구와 나지구보다 항시 낮았다. 동일 강우강도에서 유거는 대조구, glyposate 처리구, paraquat 처리구 glyposate-처리 나지구 순으로 증가하였다. 높은 강우강도하에서 처리구가간 유거의 차이는 1년차에서 가장 높았다. 조사 기간 3년간 토양손실은 각각 달랐다. 미세입자 손실이 조립질보다 높았으나 토양손실은 유거나 총강우량과 상관성은 없는 것으로 조사되었다. 동일 강우강도하에서 토양침식율은 대조구, glyposate 처리구, paraquat 처리구 glyposate-처리 나지구 순으로 증가하였다. 상대적으로 30 mm 이하의 강우강도하에서는 조사구간 제초제 처리 여부 상관성이 거의 없었다. 이는 토양침식은 강우강도에 의존한다는 것을 의미한다.