• 제목/요약/키워드: Radon management

검색결과 43건 처리시간 0.027초

IoT 기반 라돈 측정 제어시스템 설계 및 구현 (The Design and Implementation of IoT-Based Radon Measurement Control System)

  • 안희학;구자영;이상윤
    • 디지털산업정보학회논문지
    • /
    • 제16권1호
    • /
    • pp.1-10
    • /
    • 2020
  • This paper is a IoT-based radon meter control system and a radon meter control method using it. The IoT-based radon meter control system is control system for controlling a radon meter by network-connecting radon meter and a user terminal. The radon measuring device may be provided with a radon sensor to measure a radon value of a preset management target area, it collect and store numerical data. The radon meter control system monitors the condition of the radon meter, it includes control center configured to deliver radon meter management information generated to a user terminal. Also radon measurements to determine the exact amount of radon gas. Therefore, the situation-specific actions based on radon numbers can be promptly implemented to ensure adequate protection for those who are vulnerable to radon and those who live in the area. Condition monitoring allows the radon meter to respond quickly to failure or failure of the radon meter. In addition, it is possible to secure a baseline of radon's influence and to obtain research data to cope with radon by establishing big data with radon measurements.

라돈의 영향과 관리 (Effects of radon and its management)

  • 조승연;김선홍;김민준
    • 실내환경 및 냄새 학회지
    • /
    • 제16권4호
    • /
    • pp.297-307
    • /
    • 2017
  • As radon is a naturally occurring radioactive gas that can cause lung cancer and is classified as a Group 1 carcinogen, it is essential for the public to be aware of what radon is, and how to manage radon. Therefore, general information on radon, as well as its health risks, measurement methods, mitigation methods and suggestions for its management are addressed in this article. Over the last one to two decades, a number of wide-ranging studies on radon measurement and mitigation have been conducted in Korea, and the results of each study are comparable to the research achievements of other developed countries. For this reason, it is time to systematically establish a well-made Korean radon management organization.

군부대 시설 및 지하철 역사 주변 지하상가의 측정농도와 노출시간을 이용한 실내에서의 라돈 위해성 평가 (Indoor Radon Risk Assessment by Applying Measurement Concentrations and Exposure Times for Military Facilities and Underground Shopping Malls near Subway stations)

  • 공진석;김영희
    • 한국환경보건학회지
    • /
    • 제42권5호
    • /
    • pp.345-351
    • /
    • 2016
  • Objectives: The objective of this study was to conduct risk assessment using indoor radon concentration and exposure times. Methods: The target facilities were military facilities before and after the application of radon reduction processes and underground commercial facilities in major subway stations in Seoul. Indoor radon concentrations were measured by passive sampler. Results: Radon concentrations in 13 military facilities were initially higher than the guidelines, but the levels were below guidelines after the application of radon reduction processes. Underground shopping mall radon concentrations near subway stations in Seoul satisfied the guidelines. However, indoor radon effective doses after radon reduction processes in some military facilities and those in underground shopping malls belonged to International Commission on Radiological Protection (ICRP) groups needing control management. Conclusion: Indoor radon management requires risk assessment data that takes into account working time (or residence time) in addition to management according to concentration guidelines.

국내·외 라돈 관련 제도 비교를 통한 산업안전보건법 개선방안 (Improvement of the Occupational Safety and Health Act by the Comparison of the Domestic and Foreign Radon-related Policies)

  • 임대성;김기연;조용민;서성철
    • 한국산업보건학회지
    • /
    • 제31권3호
    • /
    • pp.226-236
    • /
    • 2021
  • Objectives: Concerns have been raised about the possible health effects of radon on both workers and consumers with the spread of social attention to the impact of radon exposure. Thus, an entire raw material handling workshop was investigated, and standards for radon levels in the workplace were newly established at 600 Bq/m3. However, regulations on the management of workers exposed to radon are still insufficiently developed. Therefore, by comparative analysis of overseas and domestic radon-related regulations for workplaces, this study aims to suggest improvement plans of protection regulations under the Occupational Safety and Health Act (OSH Act) for the prevention of health disorders of radon-exposed workers. Methods: For overseas case studies, we consulted radon-related laws and reports officially published on the websites of the European Union (EU), the United States (U.S.) and the United Kingdom (UK) government agencies. Domestic law studies were conducted mainly on the Act on Protective Action Guidelines against Radiation in the Natural Environment and the OSH Act. Results: In Europe, the basic safety standards for protection against risks arising from radon (Council Directive 2013/59/EURATOM of 5 December 2013) was established by the EU. They recommend that the Member States manage radon level in workplaces based on this criterion. In the U.S., the standards for workplaces are controlled by the Occupational Safety and Health Administration (OSHA) and the Mine Safety and Health Administration (MSHA). Action on radon in the UK is specified in "Radon in the workplace" published by the Health and Safety Executive (HSE). Conclusions: The Act on Protective Action Guidelines against Radiation in the Natural Environment mainly refers to the management of workplaces that use or handle raw materials but does not have any provisions in terms of protecting naturally exposed workers. In the OSH Act, it is necessary to define whether radon is included in radiation for that reason that its current regulations have limitations in ensuring the safety workers who may be exposed to naturally occurring radon. The management standards are needed for workplaces that do not directly deal with radon but are likely to be exposed to radon. We propose that this could be specified in the regulations for the prevention of health damage caused by radiation, not in Article 125 of the OSH Act.

5678 서울도시철도 지하역사의 라돈 관리 현황 (Current Status of Radon Management in the 5678 Seoul Metropolitan Rapid Transit Subway)

  • 김준현;윤현식;서강진;우희영;김만화;박종헌
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 춘계학술대회 논문집
    • /
    • pp.1306-1312
    • /
    • 2011
  • Underground Subway station's air pollutants are introduced from the indoor or outdoor. And Radon is a major pollutant in the subway station. Radioactive substances Radon is occuring naturally in granite tunnel wall and underground water. Especially inert gas Radon that causes lung cancer in human is anywhere but 5678 S.M.R.T. tunnels deep and pass through the granite plaque have a lot of Radon. The Radon concentration is determined by the following reasons : radon content of soil and concrete, underground water, ventilation, pressure difference, building structure, temperature, etc. So Radon concentration is hard to predict. And we can't only ventilate owing to era of high oil prices. This study focuses on our efforts for the reduction of Radon concentration. And the purpose is to provide basically datas of specially managed 15 subway station's Radon concentration.

  • PDF

계절적 라돈농도 변화 및 토양기원 실내라돈과 토양내 라돈농도의 상관성 분석 -단독주택 사례연구- (Seasonal Radon Concentration and Correlation Analysis of Indoor Radon Originated from Soil and Soil Radon at Detached House)

  • 조주현;김영희
    • 한국지하수토양환경학회지:지하수토양환경
    • /
    • 제22권5호
    • /
    • pp.105-111
    • /
    • 2017
  • In this study, the variation of indoor and soil radon concentrations were measured at a test bed (detached house), and correlation analysis was performed using linear regression. The results showed that the average concentration of indoor radon was increased by about 20% when the heater was operated in the house, but it was decreased by 15% when the ventilation system was on. In the changes of seasonal radon concentrations, soil and indoor radon concentrations in winter were higher than in summer. Statistical analysis showed a weak correlation between the soil radon and indoor radon, but the correlation (R=0.852, $R^2=0.726$) was relatively high at exhaust condition in the winter. It is difficult to extrapolate the results of the study to the general cases because radon distribution is highly site-specific, but the result of this study could be used as a reference for radon management and reduction of detached house in the future investigations.

지각방사선(라돈) 참조준위별 저감 대책에 따른 비용 편익 분석 (Cost-benefit Analysis on Occupational Reference Levels for Radon)

  • 최은희;정은교;김수근;정명희
    • 한국산업보건학회지
    • /
    • 제29권1호
    • /
    • pp.57-68
    • /
    • 2019
  • Objective: The purpose of this study is to propose the benefits of reduction measures according to the occupational radon reference level in order to present basic data for radon management guidelines considering domestic circumstances. Methods: This study uses radon data measured in the subway stations from 2015 to 2016. Of the total of 4,643 cases, 4,231 cases were analyzed excluding the 412 cases where the values were below $300Bq/m^3$. Results: Cost-Benefit analysis was done on the results of the field survey on subway work sites. At the exposure level of $400Bq/m^3$, the ratio between the cost and the benefit was highest at 1 : 1.81(the cost was KRW 1,398,568,032, while the benefit KRW 2,5248,772,841). At the exposure level of $600Bq/m^3$, the ratio of cost and benefit was 1: 1.80, at $300Bq/m^3$ it was 1.72, at $800Bq/m^3$ it was 1.71, at $200Bq/m^3$ it was 1.54, and at $100Bq/m^3$ it was 1.40. Conclusions: Radon management in the workplace provides economic benefits and appropriate reduction strategies are needed. In addition, it is necessary to establish and distribute radon exposure assessment procedures and guidelines for the safety and health of employees when exceeding the exposure standard, and guidelines for radon management in the workplace should be established.

환기에 의한 지하 역의 라돈농도 변화 (Influence of Ventilation on the Subway Radon Level)

  • 박덕신;정우성;정병철
    • 한국철도학회논문집
    • /
    • 제3권2호
    • /
    • pp.62-67
    • /
    • 2000
  • Modern people stay at indoor places about 90% of a day. Radon-222 is a gas produced by the radioactive decay of the element radium. And, radon is one of the major indoor air pollutants. Radon moves into the underground space through various routes and is considered to cause lung cancer by hurting the lung tissues. In this study, we measured the subway radon level at 9 stations of 3 lines. According to test results, we can figure out the concentration of radon by lines, times, and measuring points. So, it was found that ventilation conditions are the most important factors in the subway air quality. Finally, we suggested effective and economic management methods of air pollution in the subway.

  • PDF

라돈 우선관리 대상 지역 선정에 적합한 공간분석모형의 선정 및 활용에 관한 연구 (Study on the Selection and Application of a Spatial Analysis Model Appropriate for Selecting the Radon Priority Management Target Area)

  • 남궁선주;최길용;홍형진;윤단기;김윤신;박시현;김윤관;이철민
    • 한국환경보건학회지
    • /
    • 제45권1호
    • /
    • pp.82-96
    • /
    • 2019
  • Objective: The aims of this study were to provide the basic data for establishing a precautionary management policy and to develop a methodology for selecting a radon management priority target area suitable for the Korean domestic environment. Methods: A suitable mapping method for the domestic environment was derived by conducting a quantitative comparison of predicted values and measured values that were calculated through implementation of two models such as IDW and RBF methods. And a qualitative comparison including the clarity of information transmission of the written radon map was carried out. Results: The predicted and measured values were obtained through the implementation of the spatial analysis models. The IDW method showed the lowest in the calculated mean square error and had a higher correlation coefficient than the other methods. As results of comparing the uncertainty using the jackknife concept and the concept of error distance for comparison of the differences according to the model interpolation method, the sum of the error distances showed a modest increase compared with the RBF method. As a result of qualitatively comparing the information transfer clarity between the radon maps prepared with the predicted values through the model implementation, it was found that the maps plotted using the predicted values by the implementation of the IDW method had greater clarity in terms of highness and lowness of radon concentration per area compared with the maps plotted by other methods. Conclusions: The radon management priority area suggests selecting a metropolitan city including an area with a high radon concentration.

CONSTRUCTION OF AN ENVIRONMENTAL RADON MONITORING SYSTEM USING CR-39 NUCLEAR TRACK DETECTORS

  • AHN GIL HOON;LEE JAI-KI
    • Nuclear Engineering and Technology
    • /
    • 제37권4호
    • /
    • pp.395-400
    • /
    • 2005
  • An environmental radon monitoring system, comprising a radon-cup, an etching system, and a track counting system, was constructed. The radon cup is a cylindrical chamber with a radius of 2.2 cm and a height of 3.2 cm in combination with a CR-39 detector. Carbon is impregnated in the bodies of the detector chamber to avoid problem of an electrostatic charge. The optimized etching condition for the CR-39 exposed to a radon environment turned out to be a 6 N NaOH solution at 70^{\circ}$ over a 7hour period. The bulk etch rate under the optimized condition was $1.14{\pm}0.03\;{\mu}m\;h^{-1}$. The diameter of the tracks caused by radon and its progeny were found to be in the range of $10\~25\;{\mu}m$ under the optimized condition. The track images were observed with a track counting system, which consisted of an optical microscope, a color charged couple device (CCD) camera, and an image processor. The calibration factor of this system is obtained to be $0.105{\pm}0.006$ tracks $cm^2$ per Bq $m^{-3}$ d.