• Title/Summary/Keyword: Radius error

Search Result 275, Processing Time 0.023 seconds

Quantitative Conductivity Estimation Error due to Statistical Noise in Complex $B_1{^+}$ Map (정량적 도전율측정의 오차와 $B_1{^+}$ map의 노이즈에 관한 분석)

  • Shin, Jaewook;Lee, Joonsung;Kim, Min-Oh;Choi, Narae;Seo, Jin Keun;Kim, Dong-Hyun
    • Investigative Magnetic Resonance Imaging
    • /
    • v.18 no.4
    • /
    • pp.303-313
    • /
    • 2014
  • Purpose : In-vivo conductivity reconstruction using transmit field ($B_1{^+}$) information of MRI was proposed. We assessed the accuracy of conductivity reconstruction in the presence of statistical noise in complex $B_1{^+}$ map and provided a parametric model of the conductivity-to-noise ratio value. Materials and Methods: The $B_1{^+}$ distribution was simulated for a cylindrical phantom model. By adding complex Gaussian noise to the simulated $B_1{^+}$ map, quantitative conductivity estimation error was evaluated. The quantitative evaluation process was repeated over several different parameters such as Larmor frequency, object radius and SNR of $B_1{^+}$ map. A parametric model for the conductivity-to-noise ratio was developed according to these various parameters. Results: According to the simulation results, conductivity estimation is more sensitive to statistical noise in $B_1{^+}$ phase than to noise in $B_1{^+}$ magnitude. The conductivity estimate of the object of interest does not depend on the external object surrounding it. The conductivity-to-noise ratio is proportional to the signal-to-noise ratio of the $B_1{^+}$ map, Larmor frequency, the conductivity value itself and the number of averaged pixels. To estimate accurate conductivity value of the targeted tissue, SNR of $B_1{^+}$ map and adequate filtering size have to be taken into account for conductivity reconstruction process. In addition, the simulation result was verified at 3T conventional MRI scanner. Conclusion: Through all these relationships, quantitative conductivity estimation error due to statistical noise in $B_1{^+}$ map is modeled. By using this model, further issues regarding filtering and reconstruction algorithms can be investigated for MREPT.

Design Factor Analysis of End-Effector for Oriental Melon Harvesting Robot in Greenhouse Cultivation (시설재배 참외 수확 로봇용 엔드이펙터의 설계 요인 분석)

  • Ha, Yu Shin;Kim, Tae Wook
    • Journal of Bio-Environment Control
    • /
    • v.22 no.3
    • /
    • pp.284-290
    • /
    • 2013
  • This study analyzed the geometric, compressive, cutting and friction properties of oriental melons in order to design a gripper capable of soft handling and a cutter for cutting oriental melon vine among the end effector of oriental melon as a preliminary step for developing the end effector of the robot capable of harvesting oriental melons in protected cultivation. As a result, the average length, diameter at the midpoint, weight, volume and roundness of the oriental melons were 108 mm, 70 mm, 188 g, 333 mL and 3.8 mm. Nonlinear regression analysis was performed on the equation $W=L^a{\times}D_2^b$ with variation of the length (L) and diameter (D2) of the weight (W) of the oriental melons. As a result, it was shown that there was a correlation between a of 2.0279 and b of -0.9998 as a constant value. The average diameter of the oriental melon vine was 3.8 mm, and most vines were distributed within a radius of 5 mm from the center. The average yield value, compressive strength and hardness of the oriental melons were $36.5N/cm^2$, $185.7N/cm^2$ and $636.7N/cm^2$, respectively. The average cutting force and shear strength of the oriental melon vines were $2.87{\times}10^{-2}\;N$ and $5.60N/cm^2$, respectively. The maximum friction coefficient of the oriental melons was rubber of 0.609, followed by aluminium of 0.393, stainless steel of 0.177 and teflon of 0.079. It was considered possible to apply it to the size of the gripper and cutter, turning radius, dynamics of drive motor and selection of materials and their quality in light of the position error and safety factor according to the movement when designing end effector based on the analyzed data.

An Electrical Conductivity Reconstruction for Evaluating Bone Mineral Density : Simulation (골 밀도 평가를 위한 뼈의 전기 전도도 재구성: 시뮬레이션)

  • 최민주;김민찬;강관석;최흥호
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.261-268
    • /
    • 2004
  • Osteoporosis is a clinical condition in which the amount of bone tissue is reduced and the likelihood of fracture is increased. It is known that the electrical property of the bone is related to its density, and, in particular, the electrical resistance of the bone decreases as the bone loss increases. This implies that the electrical property of bone may be an useful parameter to diagnose osteoporosis, provided that it can be readily measured. The study attempted to evaluate the electrical conductivity of bone using a technique of electrical impedance tomography (EIT). It nay not be easy in general to get an EIT for the bone due to the big difference (an order of 2) of electrical properties between the bone and the surrounding soft tissue. In the present study, we took an adaptive mesh regeneration technique originally developed for the detection of two phase boundaries and modified it to be able to reconstruct the electrical conductivity inside the boundary provided that the geometry of the boundary was given. Numerical simulation was carried out for a tibia phantom, circular cylindrical phantom (radius of 40 mm) inside of which there is an ellipsoidal homeogenous tibia bone (short and long radius are 17 mm and 15 mm, respectively) surrounded by the soft tissue. The bone was located in the 15 mm above from the center of the circular cross section of the phantom. The electrical conductivity of the soft tissue was set to be 4 mS/cm and varies from 0.01 to 1 ms/cm for the bone. The simulation considered measurement errors in order to look into its effects. The simulated results showed that, if the measurement error was maintained less than 5 %, the reconstructed electrical conductivity of the bone was within 10 % errors. The accuracy increased with the electrical conductivity of the bone, as expected. This indicates that the present technique provides more accurate information for osteoporotic bones. It should be noted that tile simulation is based on a simple two phase image for the bone and the surrounding soft tissue when its anatomical information is provided. Nevertheless, the study indicates the possibility that the EIT technique may be used as a new means to detect the bone loss leading to osteoporotic fractures.

The Change in Corneal Eccentricity on the Correction of Refractive Error using Reverse Geometry Lens (역기하렌즈(Reverse Geometry Lens)의 굴절교정시 각막 편심률(Eccentricity)의 변화)

  • Lee, Seok-Ju;Park, Seong-Jong;Chun, Young-Yun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.145-150
    • /
    • 2010
  • Purpose: In this study we investigated the correlation between the effect of myopia correction and the change of corneal eccentricity using reverse geometry lens. Methods: The 23 students (46 eyes) continuously wearing reverse geometry lens during 3 months were divided into Group I and Group II by different parameter fitting methods of wearing Reverse Geometry Lens. We measured a corneal eccentricity for Group I and Group II at $10^{\circ}$, $20^{\circ}$, and $30^{\circ}$ positions from corneal apex before wearing reverse geometry lens, 1 week, 1 month, and 3 months after wearing reverse geometry lens. We also measured an uncorrected visual acuity, a spherical equivalent, and a corneal radius and analyzed the correlation between them and the change of corneal eccentricity using statistical significance test. Results: There were the statistical significances of a change of corneal eccentricity (p=0.03, t=-2.29) for Group I and Group II at 10 position from corneal apex in a week after wearing reverse geometry lens, but were not those (p>0.05) in 1 month, and 3 months after wearing reverse geometry lens. There were the statistical significances of correlation between the change of corneal eccentricity and a corrected visual acuity, and a corneal radius, respectively. Particularly, the high correlation between the change of corneal eccentricity and a corrected visual acuity (r=-0.36, p=0.00, t=6.5), and a spherical equivalent (r=-0.72, p=0.00, t=-70.5) for Group II in a week after wearing reverse geometry lens showed. Conclusions: We knew from these results that the high correlation between the effect of myopia correction and the change of corneal eccentricity in a week after wearing reverse geometry lens represented.

Hydraulic Resistance Characteristics of Compacted Weathered Granite Soil by Rotating Cylinder Test and Image Analysis (영상처리기법과 회전식 수리저항성능 실험을 이용한 다짐화강풍화토의 수리저항특성 분석)

  • Kim, Young Sang;Lim, Jae Seong
    • Journal of the Korean Geotechnical Society
    • /
    • v.32 no.7
    • /
    • pp.25-34
    • /
    • 2016
  • Recently, in Korea, problems related with unstability of slope or sinkhole in urban area due to erosion of compacted granite soil which was used as a backfill or embankment material have been treated as important issues. Small hole might develop inside of backfill area due to erosion of not only weathered granite soil but also clay, silt, fine sand size particles when underground water flows. Once erosion starts in a soil mass, erosion rate increases gradually to cause rapid destruction. In this study, a rotating cylinder test (RCT) was performed to evaluate the hydraulic resistance characteristics of compacted weathered granite soil under various relative densities and preconsolidation pressures. Meanwhile, an image analysis method was introduced to analyze radius of irregularly eroded sample. It was found that image analysis is an effective means of minimizing the error in calculating a critical shear stress and threshold shear stress on the irregularly eroded sample. Furthermore, in general, hydraulic resistance capacity increases with the increase of relative density and preconsolidation pressure.

Measurement for the Tuning Circle of the Stern Trawler HAELIM-3 by the Differential GPS (DGPS에 의한 선미트롤선 해림 3호의 선회권측정)

  • Choi, Jae-Eun;Kim, Jin-Kun;Kim, Ki-Yun
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.31 no.1
    • /
    • pp.84-92
    • /
    • 1995
  • The methods by turning circle test and maneuvering indices have been used to study and evaluate the maneuverability of a ship. However recently many studies utilizing the GPS are made on the measurement of the turning circle and in the fishery and hydrographic survey. In this paper, the author carried out the turning circle test using the differential GPS and dumb card together, and compared the data measured by them and analyzed the accuracies of them to obtain the utility basic ones on the measurement of the turning circle by the DGPS. The main results area s follows : 1) To check the accuracies of the GPS, the circling experiments of 50m radius by the DGPS were made on the ground. The accuracies of turning circle measured by the DGPS were found to be very high as the errors of 1.5m. 2) the turning circle by the DGPS could be measured very accurately, by the seed, rudder angle, starboard and port respectively. 3) The turning circle measured by the dumb card was found to be measured accurately as much as the DGPS, when using large rudder angle, the turning circle was large, the turning circle by the dumb car could not be measured accurately on account of large error of bearing of compass. 4) The tactical diameters by the DGPS in case of the rudder angle 35。~5。, were found to be 2.6。15.0 times the Lpp of S.T HAELIM-3 at her slow speed 2.8~16.6 times her Lpp at her half speed, 3.1~17.4 times her Lpp at her full speed. The tactical diameter by the dumb card was found to be 2.4~9.5 times, 2.6~9.6 times, 3.2~12.2 times her Lpp respectively, in the above case and speed.

  • PDF

Underwater Telemetering by Ultrasonic Multi-Beam Transducer (Multi-Beam 초음파진동자의 수중원격제어에 관한 연구)

  • Choe, Han-Gyu;Sin, Hyeong-Il
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.27 no.1
    • /
    • pp.31-40
    • /
    • 1991
  • This paper described on the availability fo the underwater telemetering by the ulterasonic multi-beam system made as a trial to expand detectable range of the fish school. The ultrasonic multi-beam system consisted of four transducers which reconstructed with the existing net recorder. The experiment for the telemetering carried out in the set net fishing ground. The results obtained are summerized as follows: 1. The detectable distance of a target by the linear arrangement of four transducers increased according to the sea depth and the interval between transducers. 2. When the fish school in the entrance of set net was measured by linear arrangement of transducers it was entered in depth of 2.5~3.5m at near position of leader, and in depth of 3.5~4.5m at near position of door net. 3. The deviations of error between the actual position and the position by transducer in case of the target depth 1m, 1.5m, 2m were 5.9~27.1cm, 3.2~28.9cm, 3.5~25.8cm respectively, and 68.3% probability radius of them were 14.6cm, 17.7cm, 17.0cm respectively. 4. When the fish school in the fish court of set net was measured by plane arrangement of transducer it was entered toward the opposite direction of tide current. 5. The available distance of telemetering by the multi-beam transducer was 1.8km and the telemetering was possible to control everywhere in case of sea depth more than three meters.

  • PDF

The Impacts of Proposed Landfill Sites on Housing Values

  • Jung, Su Kwan
    • Environmental and Resource Economics Review
    • /
    • v.21 no.3
    • /
    • pp.743-776
    • /
    • 2012
  • This study utilizes the meta-analysis for the benefits transfer (MA-BT) approach to measure social costs the 7 target sites in the City and County of Honolulu. The estimated MA models (MA-1 and MA-1) were evaluated in terms of validity and reliability criteria. This study utilized a parametric t-test and a non-parametric sign rank test for checking validity. A transfer error measured by an absolute percentage difference was utilized to check reliability their similarity. The GIS was utilized for data collection in order to measure social costs for each target site. The results clearly demonstrated that social costs were substantially higher thant direct costs and varied market conditions and different methods used. In terms of validity and reliability criteria, MA models were preferred to the mean transfer value approach. MA-BT approach is desirable for measuring social costs for a project designed to measure social costs for these 7 proposed landfill sites with inaccessible data, on short time frames, and with little money. If researchers and planners have enough time and money, they can implement primary research. If not, the meta-analysis for the benefits transfer approach can be much better than no framework. The use of a GIS can help to identify secondary data within a specific radius of each target site.

  • PDF

Association between Axial Length and Anthropometric Value in Korean Children (한국 어린이의 안축장과 신체 계측치와의 관련성)

  • Kim, Hyojin;Lyu, Jungmook
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.19 no.3
    • /
    • pp.397-402
    • /
    • 2014
  • Purpose: To investigate the relationship between axial length (AL) and anthropometric parameters in Korean children. Methods: This study included 40 urban school children aged 11-12 years (mean age, $11.95{\pm}0.22$ years; 45.0% girls) residing in Seoul, South Korea. AL (using partial coherence laser interferometry), corneal radius, refractive error, height (m), and weight (kg) were measured. Body mass index (BMI $[kg/m^2]=weight/[height]^2$) and degree of obesity (DO[%]=[actual weight standard weight]/standard weight) were calculated. Furthermore, the number of hours spent reading, watching television, and using a computer every day was determined using a detailed questionnaire. Results: The students had a mean spherical equivalent refraction of $1.06{\pm}0.84$ D. Weight (r=0.427, p=0.006), BMI (r=0.508, p=0.001), and DO (r=0.371, p=0.018) showed a significant positive correlation with AL. Furthermore, longer AL was significantly associated with heavier weight (p=0.041), and higher BMI (p=0.015), and higher DO quartiles (p=0.042). After adjust for age, sex, and near-work activities, multivariate linear regression models showed that weight, BMI, and DO were still significantly associated with AL. Among the near-work activities, daily reading time was significantly associated with AL. Conclusions: AL was positively related to weight as well as daily reading time in Korean urban school children.

Relationship of Refractive and Anatomical Changes on Eyes after Alcohol Ingestion (알코올 섭취에 의한 눈의 굴절변화와 해부학적 변화와의 관계)

  • Kim, Jung-Ouk;Moon, Byeong-Yeon;Cho, Hyun Gug
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.15 no.2
    • /
    • pp.195-199
    • /
    • 2010
  • Purpose: This study was to investigate the relevance between refractive and anatomical changes temporarily on the eyes after alcohol ingestion. Methods: Eight subjects (16 eyes) which were $24.5{\pm}1.5$ aged males drunk the alcohol of 0.42 g per kg of body weight within 30 minutes. Refractive errors, the radius of corneal curvature, corneal thickness, pupillary size, intraocular pressure, and the length of the ocular axis at 1 h, 4 h, and 24 h after alcohol ingestion were compared with them of non-alcoholic state. Results: At 1 h after alcohol ingestion, breath alcohol concentration was the highest (p<0.001), more negative spherical power was needed (p<0.05) for correction, pupillary diameter was decreased (p<0.05), intraocular pressure was decreased (p<0.001), and the length of the ocular axis was increased compared with each one of non-alcoholic state. At 4 h after alcohol ingestion, all anatomical changes were the same tendency as at 1 h after alcohol ingestion. But at 24 h after alcohol ingestion, both refractive changes and anatomical changes were not significant compared with them of non-alcoholic state. Conclusions: Temporary changes of refractive error after alcohol ingestion may be related with decrease of intraocular pressure and increase of the length of ocular axis.