• Title/Summary/Keyword: Radiotechnologist

Search Result 18, Processing Time 0.022 seconds

A Study Concerning of Servant Leadership of Radiotechnologist (방사선사의 서번트 리더십에 관한 고찰)

  • An, Hyun;Ko, Seong-Jin;Kang, Se-Sik;Kim, Dong-Hyun;Kim, Chang-Soo;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.35 no.3
    • /
    • pp.201-210
    • /
    • 2012
  • This study aimed to look at servant leadership that general radiotechnologist perceive from the servant leadership perspective and based on this to suggest ways to improve not only organizational effects of radiotechnologist who work clinically but also their working conditions. A population of 290 radiotechnologist who work at hospital in Pusan was the subject of this study and a survey was conducted to them. The analysis for the collected data used SPSS/PC+Win13 version and one-way, ANOVA was carried out to verify differences between groups. Servant leadership according to background factors showed relatively higher values among unmarried than married, twenties or more in terms of age, and nuclear medicine department in terms of the work department than other groups. Regular positions in terms of work types and university hospitals in terms of hospital types showed high scores, and as the motive for being a radiotechnologist, many considered job prospects. Hospitals should improve the organization's ability and performance by managing human resources efficiently. According to this study, servant leadership that radiotechnologist serve the community based on true prestige with basic honesty and trust as a member of fair community is a new model of true leadership that the future society requires.

A Study on the Perception of Apprentice toward the Medical Service of Department of Radiology (임상실습을 마친 학생들의 해당병원 방사선과의 서비스 환경에 대한 인식정도)

  • Na Soo-Kyung
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.30 no.1
    • /
    • pp.36-40
    • /
    • 2004
  • The purpose of this study was conducted by analysis of questionnaire about Radiotechnologist's medical services. The respondents were a student apprentice in university medical center, general hospital and minor general hospital. The study was conducted d

  • PDF

Analysis of question-inquire test on the Clinical Specialist system in Radiologic Technologist (전문 방사선사 제도에 관한 설문조사 분석)

  • Yoon Chul Ho;Park Soung Ock
    • Journal of The Korean Radiological Technologist Association
    • /
    • v.27 no.2
    • /
    • pp.269-279
    • /
    • 2001
  • A men who has obtain a license of radiotechnologist from the government engaging in the Dept. of radiology as a technologist at various hospitals. They can engage in various part such as Diagnosis radiology, Radiation therapy, Sonography and Nuclear medic

  • PDF

Satifaction and Improvement of Clinical Experiment of Student Radiotechnologists (대학 방사선학과 학생들의 임상실습에 대한 만족도 현황과 발전방향)

  • Lyu, Kwang-Yeul;Kim, Hyun-Soo
    • Journal of radiological science and technology
    • /
    • v.29 no.4
    • /
    • pp.303-310
    • /
    • 2006
  • Clinical experiment is a set of experience to help student acquire technic, attitude and knowledge by participating in the clinical work. The radiotechnologists who are employed in departments of radiology serve as clinical instructors. Their responsibilities include teaching students them to become competent radiotechnologist. Clinical instructors often have no formal preparation in teaching student. The purpose of this study is to review some principals that will help clinical instructors support and foster the professional development of student radiotechnologists. The clinical instructor should be able to identify the qualities of instructor, the characteristics of feedback and use facillitation skills when is evaluated student performance. And the survey was performed to evaluate the satisfaction of student participated in clinical experiment, the purpose of this research is to fine the problems and improvements in clinical experiment of student radiotechnologist in Korea.

  • PDF

A Study on the Perception of Clinical Training Students Toward the Medical Service of Radiotechnologists (방사선사의 의료서비스에 대한 임상실습 학생들의 인식도)

  • Na, Soo-Kyung
    • Journal of radiological science and technology
    • /
    • v.21 no.2
    • /
    • pp.64-68
    • /
    • 1998
  • The purpose of this study was to assess the perception of students who have been clinical training course toward the medcal service of radiotechnologist. To perform this purpose, a total 313 students at 6 different colleges were interviewed with questionnaires from March to June in 1998. The results of the study are as follow : 1. The most of all students were answered that the working area and equipments were very clean. There were no differences between the types of the hospital. 2. 46.3% of students were answered that the radiotechnologists had a good releationship with the doctors. 3. 81.1% of students were answered that the radiotechnologists explained very kindly to the patients about the treatment processes. 4. There were a little differences between the female and male students about the degree of professional knowledge and their kindness. The data were analysed and processed by several advanced statistical techniques of SPSS/PC+ program version 7.5.

  • PDF

A Study for Management System of Integrity PACS Data Using DICOM Object (DICOM 객체를 활용한 무결성 PACS Data 관리시스템 구현)

  • Park, Bum-Jin;Jeong, Jae-Ho;Son, Gi-Gyeong;Jung, Young-Tae;Kang, Hee-Doo
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.15 no.1
    • /
    • pp.9-20
    • /
    • 2013
  • PACS is one of the most used medical information system and share information from other hospitals through the PACS. Data integrity means zero defects data and this is a prerequisite of information system performance. but I wonder if I can trust these informations that Incorrect information from radiotechnologist's mistakes, anonymous in emergency department, Newborn baby department, modified informations at later. And Modified informations causes defect in integrity of the data. When we import, we use DICOM header not DB data. so error occurs that DB data is deferent with DICOM Header information. This paper discusses to resolve as above problem using DICOM object such as DICOM PR, SR. And propose quality management system that can guarantee the patient information and can manage exam history.

  • PDF

Femoral Cystic Lesion in Bone Mineral Densitometry

  • Han-Kyung Seo;Do-Cheol Choi;Cheol-Min Shim;Jin-Hyeong Jo
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.27 no.1
    • /
    • pp.9-10
    • /
    • 2023
  • A 78-year-old female patient referred by the department of obstetrics and gynecology was recommended for orthopedic surgery because a cystic lesion was found in the left femoral proximal area in the bone mineral densitometry. CT scan and general X-ray performed in the orthopedic department found benign tumors later. Intra-medullary nail was operated. Curettage and bone graft were performed. Radiotechnologist is also important for the morphological observation of femur in the femoral BMD. It provides a lot of benefits to the patient.

  • PDF

Operation Efficiency Estimation of PET/CT Center by Work Form and Exposure Dose (근무형태 및 피폭선량에 따른 PET/CT실의 운영 효율성 평가)

  • Kweon, Oh-Jin;Jung, Su-Hee;Baek, Seung-Chan;Kim, Kyeong-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.13 no.1
    • /
    • pp.93-97
    • /
    • 2009
  • Purpose: Recognize circulation work system and fixing work system's merits and demerits that is enforced in operation of PET/CT center in sudden increase recently. Wish to estimate connectivity degree of individual exposure dose and PET/CT working that is managed periodically through this and look for operation efficiency of PET/CT center. Materials and Methods: (1) Find interrelationship of length of service to be individual exposure dose and PET/CT through TLD interpretation. Specially, evaluate on the basis of data of 2.5 years until 2 quarters 2006~2008 year that show patient increase rapidly the latest. (2) Recognize what countermeasure is evaluating problems happened at circulation work system and fixing work system. Results: Patient examination's number was 14,674 items until 2 quarters 2006~2008 year, and the $^{18}F$-FDG average injection amount was 461.5 MBq. 2 people of 10 radiotechnologist did fixing work PET area and GAMMA area each, and 8 people did circulation work of 3 times for 2.5 years. Average exposure dose that PET area and Gamma area's circulation men in service receive was 1.32 mSv, and PET area men in services came out average 0.825 mSv high than Gamma area men in services. Nurse's exposure dose is 0.28 mSv, and next 2 reason is conjectured. One is contact with patient that medicate $^{18}F$-FDG injection, and another is consultation about patient's next time schedule after examination end. Although exposure dose's amount is not much, is expected to consider continuation work possibility by exposure dose in case is a nurse with pregnancy possibility. Also, $^{131}I$-isotope therapy area's radiotechnologist that use capsule appeared by 0.12 mSv and a nuclear medicine doctor appeared by exposure dose that is less of 0.11 mSv. Conclusions: In case do PET/CT center circulation work after a long time, connoted danger that most men in service is consecutiveness deficiency of business and individual exposure dose increase at early 1 month. Specially, way for individual exposure dose's decrease should be considered. Also, need to evaluate abhorrent work form for efficient work system introduction, and enforce circulation and fixing work suggestion suitable shift working. Finally, must make normalized business guide and so on to prevent circulation work people's business efficiency decline.

  • PDF

A Study of Image Characteristics due to Focus-Grid and Head Phantom Decentering from the Armorphos Silicon Thin Film Transistor Detector the Fixed Focus-Grid is Applied (고정식 초점형 격자가 적용된 비정절 실리콘 평판형 검출기에서 초점-격자와 두부 팬텀의 중심 변위에 의한 화질 특성에 관한 연구)

  • Choi, Jun-Gu;Kim, Byeong-Gi;Cha, Seon-Hwa;Kim, Gyeong-Su
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.9 no.1
    • /
    • pp.7-15
    • /
    • 2007
  • This study aim to investigate image characteristics due to focus-grid and head phantom decentering from the armorphos silicon thin film transistor detector the fixed focus-grid is applied, wish to propose right use method of digital medical equipment. Acquired image according to focus-grid and head phantom position decentering using head phantom on armorphos silicon thin film transistor detector the fixed focus-grid is applied. acquired image evaluate pixel value, histogram, plot profile, surface plot using NIB (Image J) image analysis program and compared decentering image with standard image. Mean value and standard deviation value of focus-grid lateral decentering and duplex decentering of focus-grid and head phantom decreased by ratio, consequently increase of horizontality, diagonal decentering. also, deteriorated contrast of image because frequency of high pixel value decreases fairly. according increases decentering, image distortion phenomenon was increase, by next time, pixel mean value of head phantom decentering was no big change but horizontality, diagonal, mean value and standard deviation value of pixel decreased by ratio. Even if increase pixel noise of image because wide latitude and post processing ability of digital detector, radiotechnologist can not recognize. Therefore, radiotechnologist must recognize correctly the photographing factors which increases pixel noise on the grid system installation digital detector and should exam.

  • PDF

Analysis of the Awareness of Medical Radioactive Waste Management Plans (with Focus on Busan and Gyeongsangnam-do) (의료방사성폐기물 관리방안에 대한 인식 분석 - 부산, 경남을 중심으로 -)

  • Kang, Se-Sik;Choi, Seok-Yoon;Kim, Jung-Hoon
    • Journal of radiological science and technology
    • /
    • v.37 no.1
    • /
    • pp.29-36
    • /
    • 2014
  • This study was conducted to propose medical radioactive waste management methods by background factors of radioactive workers, their awareness of safety management and reduce the difficulty of self-disposal. A population of 102 radiotechnologist who work at hospital in Busan was the subject of this study and a survey was conducted to them. the analysis for the collected data used SPSS/PC+Win13 version and one-way, ANOVA was carried out of verify differences between the groups. The result showed that most of workers had correct awareness of radioactive waste management. Also, about the difficulty of self-disposal, legal procedures were mentioned most often, and as efficient improvement of management methods is concerned, changing the awareness of safety management and disposal was proposed. According to this study, the right way of managing medical radioactive waste is to change the awareness of radioactive workers by reinforcing regular training.