• Title/Summary/Keyword: Radionuclide transit study

Search Result 4, Processing Time 0.016 seconds

Radionuclide Esophageal Transit Study in the Esophageal Motility Disorders (식도 운동 질환에 있어서 동위원소 식도 통과 검사의 의의)

  • Choe, Jae-Gol;Lee, Min-Jae;Song, Chi-Wook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.233-238
    • /
    • 1993
  • Esophageal motility was evaluated from the analysis of 10 consecutive swallows using liquid bolus containing 0.5 mCi of $^{99m}Tc$ tin colloid. We have reviewed our experience of esophageal transit study in the 20 normal volunteers and 55 patients with dysphagia that was not related to mechanical obstruction. The purpose of this study is to measure the esophageal transit in normal subjects and in patients with various esophageal motility disorders. The overall sensitivity and specificity of radionuclide esophageal transit study in detecting esophageal motor abnormality were compared with manometric results as a gold standard, which were 80% and 100% respectively. Radionuclide transit study is a safe, rapid, noninvasive test and suitable as a screening test for esophageal motor disorders.

  • PDF

Clinical Evaluation of Radionuclide Esophageal Transit Studies using Liquid and Solid Foods (유동식 및 고형식을 이용한 동위원소 식도통과검사의 임상적 의의에 대한 연구)

  • Choe, Jae-Gol;Lee, Min-Jae;Song, Chi-Wook;Hyun, Jin-Hai;Suh, Won-Hyuck
    • The Korean Journal of Nuclear Medicine
    • /
    • v.29 no.1
    • /
    • pp.61-72
    • /
    • 1995
  • The author performed radionuclide esophageal transit studies(RETS) with liquid and solid boluses using the same day protocol in 90 normal controls and 164 patients with various primary esophageal motility disorders who were diagnosed by manometric criteria and clinical courses. The authors calculated mean esophageal transit time(MTT) and mean residual retention(MRR) in each of the liquid and solid studies, and classified time-activity curve(TAC) patterns. The normal criteria of RETS with liquid bolus were MTT<24 sec, MRR<9%, and the TAC pattern that showed rapid declining slope and flat low residual(Type 1). The normal criteria of RETS with solid bolus were MTT<35 sec, MRR<9% and TAC of type 1. With these normal criteria, the sensitivity and the specificity of the liquid study were 62.2 % and 97.8%, respectively. The sensitivity increased to 75.4% with the solid study. The author also found that the RETS was highly reproducible. The achalasia typically showed no effective emptying of both liquid and solid boluses during the whole study period, and was well differentiated by its extremely long transit time and high retention from the other motility disorders. The diffuse esophageal spasm (DES) and nonspecific esophageal motility disorder(NEMD) showed intermediate delay in transit time and increased retention. In the groups of hypertensive lower esophageal sphincter(LES), hypotensive LES and nutcracker, there noted no significant difference with the normal control group in terms of MTT and MRR. The DES and NEMD could be more easily identified by solid studies that showed more marked delay in MTT and increased MRR as compared with the liquid study. In conclusion, esophageal scintigraphy is a safe, noninvasive and physiologic method for the evaluation of esophageal emptying.

  • PDF

Quantitative Assessment of Esophageal Movement Using Radionuclide in Patients with Systemic Sclerosis (전신성 공피증 환자에서 방사성 동위원소를 이용한 식도 운동의 정량적 측정)

  • Bom, Hee-Seung;Lee, Myung-Hae;Chung, June-Key;Lee, Myung-Chul;Choi, Sung-Jae;Song, In-Sung;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.1
    • /
    • pp.5-8
    • /
    • 1987
  • Nineteen patients with progressive systemic sclerosis were underwent radioisotope esophageal transit study (RIETS) which revealed abnormal transit time and/or pattern in 16 (84.2%). Among them 12 showed to and fro movement of RI and 4 showed retention of it. Abnormal esophageal transit was not related with Raynaud phenomenon. After intravenous administration of metoclopramide (10 mg), percent retention of RI in distal 2/3 of esophagus was significantly reduced (p<0.05).

  • PDF

Radionuclide Angiocardiographic Evaluation of Left-to-Right Cardiac Shunts: Analysis of Time-Activity Curves (핵의학적 심혈관 촬영술에 의한 좌우 심단락의 진단 : 시간-방사능 곡선의 분석)

  • Kim, Ok-Hwa;Bahk, Yong-Whee;Kim, Chi-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.155-165
    • /
    • 1987
  • The noninvasive nature of the radionuclide angiocardiography provided a useful approach for the evaluation of left-to-right cardiac shunts (LRCS). While the qualitative information can be obtained by inspection of serial radionuclide angiocardiograms, the quantitative information of radionuclide angiocardiography can be obtained by the analysis-of time-activity curves using advanced computer system. The count ratios method and pulmonary-to-systemic flow ratio (QP/QS) by gamma variate fit method were used to evaluate the accuracy of detection and localization of LRCS. One hundred and ten time-activity curves were analyzed. There were 46 LRCS (atrial septal defects 11, ventricular septal defects 22, patent ductus arteriosus 13) and 64 normal subjects. By computer analysis of time-activity curves of the right atrium, ventricle and the lungs separately, the count ratios modified by adding the mean cardiac transit time were calculated in each anatomic site. In normal subjects the mean count ratios in the right atrium, ventricle and lungs were 0.24 on average. In atrial septal defects, the count ratios were high in the right atrium, ventricle and lungs, whereas in ventricular septal defects the count ratios were higher only in the right ventricle and lungs. Patent ductus arteriosus showed normal count ratios in the heart but high count ratios were obtained in the lungs. Thus, this count ratios method could be separated normal from those with intra cardiac or extracardiac shunts, and moreover, with this method the localization of the shunt level was possible in LRCS. Another method that could differentiate the intracardiac shunts from extracardiac shunts was measuring QP/QS in the left and right lungs. In patent ductus arteriosus, the left lung QP/QS was higher than those of the right lung, whereas in atrial septal defects and ventricular septal defects QP/QS ratios were equal in both lungs. From this study, it was found that by measuring QP/QS separately in the lungs, intracardiac shunt could be differenciated from extracardiac shunts.

  • PDF