Radionuclide Angiocardiographic Evaluation of Left-to-Right Cardiac Shunts: Analysis of Time-Activity Curves

핵의학적 심혈관 촬영술에 의한 좌우 심단락의 진단 : 시간-방사능 곡선의 분석

  • Kim, Ok-Hwa (Department of Radiology, Catholic University Medical College) ;
  • Bahk, Yong-Whee (Department of Radiology, Catholic University Medical College) ;
  • Kim, Chi-Kyung (Department of Chest Surgery, Catholic University Medical College)
  • 김옥화 (가톨릭대학대학 의학부 방사선과학교실) ;
  • 박용휘 (가톨릭대학대학 의학부 방사선과학교실) ;
  • 김치경 (가톨릭대학대학 의학부 흉부외과학교실)
  • Published : 1987.11.13

Abstract

The noninvasive nature of the radionuclide angiocardiography provided a useful approach for the evaluation of left-to-right cardiac shunts (LRCS). While the qualitative information can be obtained by inspection of serial radionuclide angiocardiograms, the quantitative information of radionuclide angiocardiography can be obtained by the analysis-of time-activity curves using advanced computer system. The count ratios method and pulmonary-to-systemic flow ratio (QP/QS) by gamma variate fit method were used to evaluate the accuracy of detection and localization of LRCS. One hundred and ten time-activity curves were analyzed. There were 46 LRCS (atrial septal defects 11, ventricular septal defects 22, patent ductus arteriosus 13) and 64 normal subjects. By computer analysis of time-activity curves of the right atrium, ventricle and the lungs separately, the count ratios modified by adding the mean cardiac transit time were calculated in each anatomic site. In normal subjects the mean count ratios in the right atrium, ventricle and lungs were 0.24 on average. In atrial septal defects, the count ratios were high in the right atrium, ventricle and lungs, whereas in ventricular septal defects the count ratios were higher only in the right ventricle and lungs. Patent ductus arteriosus showed normal count ratios in the heart but high count ratios were obtained in the lungs. Thus, this count ratios method could be separated normal from those with intra cardiac or extracardiac shunts, and moreover, with this method the localization of the shunt level was possible in LRCS. Another method that could differentiate the intracardiac shunts from extracardiac shunts was measuring QP/QS in the left and right lungs. In patent ductus arteriosus, the left lung QP/QS was higher than those of the right lung, whereas in atrial septal defects and ventricular septal defects QP/QS ratios were equal in both lungs. From this study, it was found that by measuring QP/QS separately in the lungs, intracardiac shunt could be differenciated from extracardiac shunts.

Keywords