• Title/Summary/Keyword: Radionuclide analysis

Search Result 135, Processing Time 0.026 seconds

A Method to Calculate Off-site Radionuclide Concentration for Multi-unit Nuclear Power Plant Accident (다수기 원자력발전소 사고 시 소외 방사성물질 농도 계산 방법)

  • Lee, Hye Rin;Lee, Gee Man;Jung, Woo Sik
    • Journal of the Korean Society of Safety
    • /
    • v.33 no.6
    • /
    • pp.144-156
    • /
    • 2018
  • Level 3 Probabilistic Safety Assessment (PSA) is performed for the risk assessment that calculates radioactive material dispersion to the environment. This risk assessment is performed with a tool of MELCOR Accident Consequence Code System (MACCS2 or WinMACCS). For the off-site consequence analysis of multi-unit nuclear power plant (NPP) accident, the single location (Center Of Mass, COM) method has been usually adopted with the assumption that all the NPPs in the nuclear site are located at the same COM point. It was well known that this COM calculation can lead to underestimated or overestimated radionuclide concentration. In order to overcome this underestimation or overestimation of radionuclide concentrations in the COM method, Multiple Location (ML) method was developed in this study. The radionuclide concentrations for the individual NPPs are separately calculated, and they are summed at every location in the nuclear site by the post-processing of radionuclide concentrations that is based on two-dimensional Gaussian Plume equations. In order to demonstrate the efficiency of the ML method, radionuclide concentrations were calculated for the six-unit NPP site, radionuclide concentrations of the ML method were compared with those by COM method. This comparison was performed for conditions of constant weather, yearly weather in Korea, and four seasons, and the results were discussed. This new ML method (1) improves accuracy of radionuclide concentrations when multi-unit NPP accident occurs, (2) calculates realistic atmospheric dispersion of radionuclides under various weather conditions, and finally (3) supports off-site emergency plan optimization. It is recommended that this new method be applied to the risk assessment of multi-unit NPP accident. This new method drastically improves the accuracy of radionuclide concentrations at the locations adjacent to or very close to NPPs. This ML method has a great strength over the COM method when people live near nuclear site, since it provides accurate radionuclide concentrations or radiation doses.

Development of an Anomaly Detection Algorithm for Verification of Radionuclide Analysis Based on Artificial Intelligence in Radioactive Wastes (방사성폐기물 핵종분석 검증용 이상 탐지를 위한 인공지능 기반 알고리즘 개발)

  • Seungsoo Jang;Jang Hee Lee;Young-su Kim;Jiseok Kim;Jeen-hyeng Kwon;Song Hyun Kim
    • Journal of Radiation Industry
    • /
    • v.17 no.1
    • /
    • pp.19-32
    • /
    • 2023
  • The amount of radioactive waste is expected to dramatically increase with decommissioning of nuclear power plants such as Kori-1, the first nuclear power plant in South Korea. Accurate nuclide analysis is necessary to manage the radioactive wastes safely, but research on verification of radionuclide analysis has yet to be well established. This study aimed to develop the technology that can verify the results of radionuclide analysis based on artificial intelligence. In this study, we propose an anomaly detection algorithm for inspecting the analysis error of radionuclide. We used the data from 'Updated Scaling Factors in Low-Level Radwaste' (NP-5077) published by EPRI (Electric Power Research Institute), and resampling was performed using SMOTE (Synthetic Minority Oversampling Technique) algorithm to augment data. 149,676 augmented data with SMOTE algorithm was used to train the artificial neural networks (classification and anomaly detection networks). 324 NP-5077 report data verified the performance of networks. The anomaly detection algorithm of radionuclide analysis was divided into two modules that detect a case where radioactive waste was incorrectly classified or discriminate an abnormal data such as loss of data or incorrectly written data. The classification network was constructed using the fully connected layer, and the anomaly detection network was composed of the encoder and decoder. The latter was operated by loading the latent vector from the end layer of the classification network. This study conducted exploratory data analysis (i.e., statistics, histogram, correlation, covariance, PCA, k-mean clustering, DBSCAN). As a result of analyzing the data, it is complicated to distinguish the type of radioactive waste because data distribution overlapped each other. In spite of these complexities, our algorithm based on deep learning can distinguish abnormal data from normal data. Radionuclide analysis was verified using our anomaly detection algorithm, and meaningful results were obtained.

Radionuclide Angiocardiography in Cogenital Heart Disease (선천성심질환(先天性心疾患)에서 방사성(放射性) 동위원소심혈관조영술(同位元素心血管造影術) -좌우단락(左右短絡)의 발견(發見)과 정량(定量)에 대하여-)

  • Kim, Byung-Chan;Noh, Byung-Suk;Sohn, Myung-Hee;Song, Ho-Yung;Kim, Chong-Soo;Kim, Jong-Keon;Choi, Ki-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.20 no.1
    • /
    • pp.85-91
    • /
    • 1986
  • In detecting, localizing and quantitating cardiac shunts, radionulide angiocardiography has been known to be a simple and safe method compared with oxymetry method. To ascertain the availability of the results obtained by radionuclide angiocardiography for the evaluation of patients with cardiac shunt, author compared the Qp/Qs ratios(pulmonary to systemic flow ratios) obtained by radionuclide angiocardiography with the results of oximetry method in 40 patients with left to right shunt, and also compared the results of radionuclide angiocardiography examined before and after shunt operation in 8 patients. The results were as follows: 1) Of the 161 patients examined radionuclide angiocardiography, 98 were thought to have cardiac shunts: right to left shunt id 27, left to right shunt in 71. Of the 71 patients who had left to right shunt, 40 who were examined with both radionuclide angiocardiography and oxymetry had following congenital heart disease: VSD in 21, ASD in 9 and PDA in 10. 2) Comparison of Qp/Qs ratios obtained during radionuclide angiocardiography and oxymetry revealed good correlation (linear regression analysis yielded correlation coefficient of 0.80) in 32 patients whose Qp/Qs ratio obtained during oxymetry were below 3.0, but very poor correlation in 8 patients whose Qp/Qs ratios were above 3.0 3) Radionuclide angiocardiography is a relatively safe and simple method in postoperative evaluation of patients with cardiac shunt.

  • PDF

Radionuclide Esophageal Transit Study in the Esophageal Motility Disorders (식도 운동 질환에 있어서 동위원소 식도 통과 검사의 의의)

  • Choe, Jae-Gol;Lee, Min-Jae;Song, Chi-Wook
    • The Korean Journal of Nuclear Medicine
    • /
    • v.27 no.2
    • /
    • pp.233-238
    • /
    • 1993
  • Esophageal motility was evaluated from the analysis of 10 consecutive swallows using liquid bolus containing 0.5 mCi of $^{99m}Tc$ tin colloid. We have reviewed our experience of esophageal transit study in the 20 normal volunteers and 55 patients with dysphagia that was not related to mechanical obstruction. The purpose of this study is to measure the esophageal transit in normal subjects and in patients with various esophageal motility disorders. The overall sensitivity and specificity of radionuclide esophageal transit study in detecting esophageal motor abnormality were compared with manometric results as a gold standard, which were 80% and 100% respectively. Radionuclide transit study is a safe, rapid, noninvasive test and suitable as a screening test for esophageal motor disorders.

  • PDF

Quantitative Analysis of Esophageal Transit of Radionuclide in Patients with Dermatomyositis-Polymyositis (피부근염-다발성근염 환자에서 방사성 동위원소를 이용한 식도 스캔의 정량적 분석)

  • Lee, Myung-Hae;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.183-188
    • /
    • 1989
  • Esophageal transit of radionuclide was quantitatively analyzed in 29 patients with dermatomyositis-polymyositis. Fourteen patients (48.3%) showed retention of tracer in oropharynx. The mean value of percent retention of oropharynx was $15.5{\pm}16.6%$. Esophageal dysfunction was found in 19 patients (65.5%). Among them 4 showed mild, 12 showed moderate and 3 showed severe esophageal dysfunction. Dysphagia was found in 11 patients (37.9%), which was closely related to percent retention of oropharynx.Quantitative analysis of esophageal transit of radionuclide seemed to be a useful technique for evaluation of dysphagia in patients with dermatomyositis-polymyositis.

  • PDF

Investigation of transport of radionuclide in a thermal stratification test facility using radiotracer technique

  • Pant, Harish Jagat;Goswami, Sunil;Chafle, Sunil B.;Sharma, Vijay Kumar;Kotak, Vimal;Shukla, Vikram;Mishra, Amitanshu;Gohel, Nilesh C.;Bhattacharya, Sujay
    • Nuclear Engineering and Technology
    • /
    • v.54 no.4
    • /
    • pp.1449-1455
    • /
    • 2022
  • A radiotracer investigation was carried out in a Thermal Stratification Test Facility (TSTF) with objectives of investigating the dispersion and diffusion of radionuclide and effectiveness of the thermocline to minimize the radionuclide content in the hot water layer. Technetium-99m (99mTc) as sodium pertechnetate was used as a radiotracer in the investigation. Qualitative analysis showed that a thermocline is formed within the TSTF and is effective in preventing the transport of radionuclide from bottom section to the top section of the facility. It was found that the radiotracer injected at the bottom of the pool took about 17.4 h to disperse from bottom to the top of the facility. The results of the investigation helped in understanding the effectiveness of hot water layer and thus to minimize the pool top radiation levels.

Radionuclide Angiocardiographic Evaluation of Left-to-Right Cardiac Shunts: Analysis of Time-Activity Curves (핵의학적 심혈관 촬영술에 의한 좌우 심단락의 진단 : 시간-방사능 곡선의 분석)

  • Kim, Ok-Hwa;Bahk, Yong-Whee;Kim, Chi-Kyung
    • The Korean Journal of Nuclear Medicine
    • /
    • v.21 no.2
    • /
    • pp.155-165
    • /
    • 1987
  • The noninvasive nature of the radionuclide angiocardiography provided a useful approach for the evaluation of left-to-right cardiac shunts (LRCS). While the qualitative information can be obtained by inspection of serial radionuclide angiocardiograms, the quantitative information of radionuclide angiocardiography can be obtained by the analysis-of time-activity curves using advanced computer system. The count ratios method and pulmonary-to-systemic flow ratio (QP/QS) by gamma variate fit method were used to evaluate the accuracy of detection and localization of LRCS. One hundred and ten time-activity curves were analyzed. There were 46 LRCS (atrial septal defects 11, ventricular septal defects 22, patent ductus arteriosus 13) and 64 normal subjects. By computer analysis of time-activity curves of the right atrium, ventricle and the lungs separately, the count ratios modified by adding the mean cardiac transit time were calculated in each anatomic site. In normal subjects the mean count ratios in the right atrium, ventricle and lungs were 0.24 on average. In atrial septal defects, the count ratios were high in the right atrium, ventricle and lungs, whereas in ventricular septal defects the count ratios were higher only in the right ventricle and lungs. Patent ductus arteriosus showed normal count ratios in the heart but high count ratios were obtained in the lungs. Thus, this count ratios method could be separated normal from those with intra cardiac or extracardiac shunts, and moreover, with this method the localization of the shunt level was possible in LRCS. Another method that could differentiate the intracardiac shunts from extracardiac shunts was measuring QP/QS in the left and right lungs. In patent ductus arteriosus, the left lung QP/QS was higher than those of the right lung, whereas in atrial septal defects and ventricular septal defects QP/QS ratios were equal in both lungs. From this study, it was found that by measuring QP/QS separately in the lungs, intracardiac shunt could be differenciated from extracardiac shunts.

  • PDF

Measurement of Shunt Amount Using Radionuclide Angiocardiography: Accuracy According to Level of Shunt and Associated Lesion (방사성 동위원소 심혈관 조영술을 이용한 단락량 측정법: 정확성에 영향을 미치는 인자)

  • Kim, Yang-Min
    • Nuclear Medicine and Molecular Imaging
    • /
    • v.40 no.4
    • /
    • pp.200-204
    • /
    • 2006
  • Purpose: Determination of pulmonary to systemic blood flow ratio (QP/QS) is important for the management of patients with left-to-right shunt. This study was performed to assess the agreement of Qp/Qs ratio using the radionuclide method and oxymetry, to investigate the factors influencing the agreement, and to know how interchangeable the results of each technique. Materials and Methods: We compared the Qp/Qs measured by single-pass radionuclide angiocardiography and oxymetry during catheterization in 207 patients who underwent both studies. In radionuclide method, Qp/Qs was calculated from the pulmonary time-activity curves using a gamma variate fit. The correlation and Bland-Altman analysis were performed according to the levels of shunt and associated lesions. Results: The mean Qp/Qs was $1.83{\pm}0.50$ by radionuclide, and $1.74{\pm}0.51$ by oxymetry. The overall correlation coefficient was 0.86(p<0.001), and Bland-Altman range of agreement encompassing 4SD was 1.05. For atrial septal defect, ventricular septal defect, patent ductus arteriosus, tricuspid and mitral insufficiency, the correlation coefficient was 0.78, 0.90, 0.84, 0.63 and 0.44, and Bland-Altman range was 1.51, 0.74, 0.96, 1.57, and 1.50, respectively. Conclusion: There is good agreement but wide variance between the Qp/Qs ratios by radionuclide method and oxymetry. Associated atrioventricular valvar insufficiency decreases the correlation coefficient and widens the variance. Wide overall variance suggests that Qp/Qs measurements by two techniques should not be used interchangeably.

Radionuclide-Specific Exposure Pathway Analysis of Kori Unit 1 Containment Building Surface

  • Byon, Jihyang;Park, Sangjune;Ahn, Seokyoung
    • Journal of Nuclear Fuel Cycle and Waste Technology(JNFCWT)
    • /
    • v.18 no.3
    • /
    • pp.347-354
    • /
    • 2020
  • Site characterization for decommissioning Kori Unit 1 is ongoing in South Korea after 40 years of successful operation. Kori Unit 1's containment building is assumed to be mostly radioactively contaminated, and therefore radiation exposure management and detailed contamination investigation are required for decommissioning and dismantling it safely. In this study, site-specific Derived Concentration Guideline Levels (DCGLs) were derived using the residual radioactivity risk evaluation tool, RESRAD-BUILD code. A conceptual model of containment building for Kori Unit 1 was set up and limited occupational worker building inspection scenario was applied. Depending on the source location, the maximum contribution source and exposure pathway of each radionuclide were analyzed. The contribution of radionuclides to dose and exposure pathways, by source location, is expected to serve as basic data in the assessment criteria of survey areas and classification of impact areas during further decommissioning and decontamination of sites.

Analysis of Absorbed Dose on the Nucleus Size Change of Single Cells using Therapeutic Radioisotopes (치료용 방사성동위원소 사용 시 단일 세포의 핵 크기 변화에 따른 흡수선량 분석)

  • Uoo-Soo, Kim;Yong-In, Cho
    • Journal of the Korean Society of Radiology
    • /
    • v.16 no.7
    • /
    • pp.1007-1014
    • /
    • 2022
  • Targeted radionuclide therapy (TRT) is a method of treating tumor cells using radiopharmaceuticals. Cells and nuclei constituting tissues of the human body are composed of spherical and oval shapes, but cancer cells are composed of various cell types. Therefore, this study analyzed the absorbed dose for each organelle according to the change in the size of the cell nucleus for beta-emitting nuclides during targeted radionuclide therapy through the Monte Carlo method. Cells were set in two sphere shapes, 5 ㎛ and 10 ㎛, and the internal structure was divided into cell nucleus, cytoplasm, and cell surface. Next, the absorbed dose according to the increase in the size of the cell nucleus was evaluated. As a result, 177Lu among the target radionuclides showed the highest dose in all cell compartments. As the ratio of the nucleus in the cell increased, the absorbed dose on the cell surface increased, but the absorbed dose in the cytoplasm and nucleus tended to decrease. Accordingly, it is judged that it is important to select a radionuclide considering the size of cancer cells and determine an appropriate amount of radioactivity during targeted radionuclide treatment.